Product Bulletin

GX Control Valve and Actuator 51.1:GX


D103171X012 August 2017

Figure 18. Fisher GX Long Face-to-Face Dimensions (also see table 22)

AR
E

A/2
GE03755_4_3 A

Table 22. Fisher GX Long Face-to-Face Dimensions and Weights


A C D TOTAL WEIGHT
Actuator
Actuator F (AR) With
Extension Height E With
PORT DIA ACTUATOR Long Long Std Height Removal Extension
VALVE SIZE or Bellows (Extension Casing Dia Standard
SIZE CL150 CL300 Bonnet (Standard Height(1) or Bellows
Bonnet or Bellows Bonnet
Bonnet) Bonnet
Bonnet)
mm mm mm mm mm mm mm mm mm kg kg
4.8 225 216 216 58 296 313 313 270 115 22 26
DN 25/ 9.5 225 216 216 58 296 313 313 270 115 22 26
NPS 1 14 225 216 216 58 296 313 313 270 115 22 26
22 225 216 216 58 296 313 313 270 115 22 26
14 225 241.3 241.3 62 300 313 313 270 115 25 29
DN 40/
22 225 241.3 241.3 62 300 313 313 270 115 25 29
NPS 1‐1/2
36 750 241.3 241.3 62 300 342 342 430 115 52 56
22 225 292.1 292.1 68 306 313 313 270 115 30 34
DN 50/
36 750 292.1 292.1 68 306 342 342 430 115 57 61
NPS 2
46 750 292.1 292.1 68 306 342 342 430 115 57 61
1. Clearance required for removing actuator from installed valve body.