Professional Documents
Culture Documents
RYfnnd 7 LQ 1180612121529
RYfnnd 7 LQ 1180612121529
RYfnnd 7 LQ 1180612121529
Location :- Kathmandu
Rate, Nrs.
S.No Description Unit Quantity
In Figures
A Provisional Sum
As Built drawing for: Site observation & measurement taken &
1 preparing drawing for civil works MD 60 2030
As Built drawing for: Site observation & measurement taken &
2 preparing drawing for sanitary works. MD 50 2030
As Built drawing for: Site observation & measurement taken &
3 preparing drawing for Electrification works. MD 50 2030
As Built drawing for: Site observation & measurement taken &
4 preparing drawing for HVAC works. MD 50 2030
Plastering with specified mortar mix ratio in any level (from base
to top of Dharahara), size and shape of wall (including cylindrical
walls), including chamfered edges of beams and vertical slab,
ceiling, band, blocks, different type of moulding and cornices
including plastering for coupings of parapet wall etc. as required
including racking, watering, cleaning and cost of necessary
scafoldings works of total height of building as per drawing,
specification & instructions of engineer all complete.: b) 12.5 mm
54 thick c/s (1:3) plaster for internal ceiling SQ.M 35251.08
Plastering with specified mortar mix ratio in any level (from base
to top of Dharahara), size and shape of wall (including cylindrical
walls), including chamfered edges of beams and vertical slab,
ceiling, band, blocks, different type of moulding and cornices
including plastering for coupings of parapet wall etc. as required
including racking, watering, cleaning and cost of necessary
scafoldings works of total height of building as per drawing,
specification & instructions of engineer all complete.: c) 20mm
55 thick c/s (1:4) plaster for internal walls SQ.M 31975.96
CLAY TILE : Clay tile cladding on sloped roof with approved shade
and sizes in cement sand mortar (1:4) including joint filling as per
73 specification and as directed by Engineer. SQM 1072.51175
CLAY TILE RIDGE WORKS: Clay ridge cladding on sloped roof with
approved shade and sizes in cement sand mortar (1:4) including
74 joint filling as per specification and as directed by Engineer. RM 235.593544
Metal Works: Providing and fixing boundary wall grill works with
25mmX25mmX3.2mm MS hollow square pipes and
50mmX50mmX4.5mm square pipes @ 3m c/c interval anchoring
in 1:2:4 plain cement concrete in boundary walls including
cutting, placing,welding and red oxide painting all complete as
113 per drawing and instructions. KG. 57692.9324
7.2) Supply & laying of hot dipped GI/pure copper earthing strip
to connect to the DBS,Poles and equipments in outdoor yard and
135 also in indoor portion of substation. 7.2.1) 25*3 mm GI strip Mtr 200
136 7.2.2) 25*6 mm GI strip Mtr 800
137 7.2.3) 35*6mm GI strip Mtr 180
138 7.2.4) 50*6 mm GI strip Mtr 450
139 7.2.5) 25*3 mm CU strip Mtr 400
140 7.2.6) 25*6 mm CU strip Mtr 5
141 7.2.7) 35*6 mm CU strip Mtr 5
142 7.2.8) 50*6 mm CU strip Mtr 150
143 7.2.9) 10 G GI wire Mtr 800
144 7.2.10) 10G CU Solid wire Mtr 20
146 b) 2 Meter GI mast with base plate & baseplate foundation bolts. Nos. 1
147 c) Guying Kit sets. Set 1
148 d) Radius of Protection 60Mtr Set 1
7.3.2) Supply of 70 Sq.mmPVC insulated stranded flexible copper
cable through 2"dia 4 mm wall thickness FRP tube with saddles
149 and fxing. RM 170
11) Point Wiring :Supply and Wiring as per below: Supply and
Wiring for the following light points with 2.5 sq.mm PVC
insulated copper conductor 1100 volts grade stranded flexible FR
wires of approved make in 20 mm dia Heavy PVC FRLS conduit
including providing and fixing of 6 amps single pole rocker
operated flush mounted switch of approved quality colour make
& design in GI box and earthing of fixtures and the outlet box
with 1.5 sq.mm PVC insulated copper conductor stranded FR
flexible wire.
(Average Length shall be 5 to 8 Mtrs.) a) Primary point controlled
153 by one 6 amps switch. Nos. 258
11.1) Supply and Wiring for the twin control light points with
2.5 sq.mm PVC insulated copper conductor 1100 volts grade
stranded flexible FRLS wires in 20mm dia Heavy PVC conduit
including providing and fixing 2 Nos. 6 amps 2 way rocker
operated flush mounted switches of approved quality colour
make and design in GI box and earthing of fixture and the outlet
box with 1.5 Sq.mm PVC insulated copper conductor
stranded flexible FRLS wire.
(Average Length shall be 5 to 8 Mtrs.)a) One Point Controlled by
155 2 Nos. two way switches Pts 10
156 b) Two Point Controlled by 2 Nos. two way switches Pts. 5
11.2) Circuit Wiring: Providing and fixing of following PVC
insulated copper conductor 1100 volt grade stranded flexible
FRLS wire in inculuding conduits 20/25 mm making connections
where ever required to complete the installation.a) 3 Nos. 2.5
sq.m PVC insulated copper conductor 1100 volts grade
157 stranded flexible FRLS wires. RM 4128
b) 3 Nos. 4 sq.mm PVC insulated copper conductor 1100 volts
158 grade stranded FRLS wires. RM 800
11.3) Supply and Wiring for 250 volts single phase and
neutral 13 amps switched universal socket outlet with 2.5
sq.mm PVC insulated copper conductor 1100 volts grade
stranded flexible FRLS wires in 25mm dia. Heavy FRLS PVC
conduit including providing and fixing of 2 nos. 13 amps switched
universal sockets of approved make and design in GI boxes with
grid plates and earthing the third pin of socket outlet with
1.5 Sq. mm PVC insulated copper conductor stranded flexible
159 FRLS wire. Set 45
11.4) Supply and Wiring for 250 volts single phase and neutral 16
amps polycarbonate splash proof (IP-55) 3 pin industrial socket
outlet with 16 amps double pole MCB/ interlocked rotary switch
in polycarbonate enclosure of approved size and design with 4
sq.mm PVC insulated copper conductor 1100 volts grade
stranded flexible FRLS wires in 25mm dia. Heavy PVC conduit
including providing and fixing of 3 pin industrial socket and
earthing of third pin of the socket outlet with 2.5 Sq. mm PVC
insulated copper conductor stranded flexible FRLS wire.
160 Set 35
172 13.5) 1x18 Watts LED under water light fitting IP65 RGB Version Nos 8
173 13.6) 1x18 Watts LED Bollard light fitting 800mm Height Nos 105
174 13.7) 1x18 Watts LED Wall down light fitting Nos 10
175 13.8) 1x18 Watts Recessed wall mound light fitting Nos 10
13.9) Street light 86W LED Light fitting with inbuilt control gear
176 box with 6.5 mtr pole including RCC Pedestal provision Nos 20
177 13.9a) 1x10 Watts Recessed LED Spot light fitting Nos 66
13.9b) Façade Light Strip (Dimension and Color as per consultant
178 approval) Mtr 800
179 13.10) SPECIAL LIGHT: Pole light (Special Type) Nos 5
180 13.11) Pole top post light (Special Type) Nos 35
15.2) Earth excavation for the required size and depth for cable
laying and refilling for laying of LT UG Armoured Cables and
188 earth strips/GI wire. (Soft Soil only) without sand and brick CM 282
15.3) Supply & Installation of 4 core x 4 Sqmm Copper armoured
189 Cable including 32 mm PVC Conduit . RM 2500
15.4) Supply & Installation of 3 core x 1.5Sqmm Copper
190 armoured cable. RM 500
57 Each 5000
PA SYSTEM a) SITC of main control panel with 6 zones;
58 expandable to 10 zones No 1
59 b) SITC Voice Alarm Call station No 1
60 c) SITC Call station Keypad No 1
61 d) SITC booster amplifier 480 W No 2
62 e) SITC booster amplifier 240 W No 4
63 f) SITC 6 watt ceiling speaker polycarbonate No 200
64 g) Wallmount15 Watt polycarbonate speaker No 50
65 h) SITC of Volume Control No 6
66 i) SITC of all in one music source No 1
67 j) SITC of equipment Rack No 1
68 k) SITC of UTP CAT 6 cable M 2500
69 l) SITC of 1 core 30/25 (1.5 sqmm) FRLS wire including connectors M 3500
Sub Head -G- Fire Exit Signages a) Providing & Fixing (Fire Exit)
Single Sided -(Wall Mounted sign: As pr your Design, 3mm ACP
102 Sheets, (Night Glow Sign) reflective vinyl pasting ACP Sheets )) No 100
b) Providing & Fixing (Fire Exit) Single Sided -(Wall Mounted sign:
As pr your Design, 3mm ACP Sheets , (Night Glow Sign) reflective
103 vinyl pasting ACP Sheets) No 30
c) Providing & Fixing (Fire Exit) Single Sided- (Wall Mounted sign:
As pr your Design, 3mm ACP Sheets , (Night Glow Sign) reflective
104 vinyl pasting ACP Sheets) No 6
h) Providing & Fixing (GR LVL) Single Sided - (Wall Mounted sign:
109 As pr your Design, 3mm ACP Sheets vinyl pasting ACP Sheets ) No 6
r) Providing & Fixing (IN CASE FIRE) Single Sided - (Wall Mounted
sign: As pr your Design, 3mm ACP Sheets, (Night Glow Sign)
119 reflective vinyl pasting ACP Sheets ) No 50
aa) Providing & Fixing (B-3 STAIR) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
128 Sheets) No 2
ab) Providing & Fixing (B-2 STAIR) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
129 Sheets) No 2
ac) Providing & Fixing (L-1 STAIR) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
130 Sheets) No 2
ad) Providing & Fixing (L-2 STAIR) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
131 Sheets) No 2
ae) Providing & Fixing (L-3 STAIR) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
132 Sheets) No 30
af) Providing & Fixing (L-4 STAIR) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
133 Sheets) No 4
ag) Providing & Fixing (L-5 STAIR) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
134 Sheets) No 4
ah) Providing & Fixing (L-6 STAIR) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
135 Sheets) No 4
ai) Providing & Fixing (L-7 STAIR) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
136 Sheets) No 4
ak) Providing & Fixing (………..) Single Sided -(Wall Mounted sign:
138 As pr your Design, 3mm ACP Sheets vinyl pasting ACP Sheets) No 8
al) Providing & Fixing (………..) Single Sided -(Wall Mounted sign:
139 As pr your Design, 3mm ACP Sheets vinyl pasting ACP Sheets) No 8
am) Providing & Fixing (LV SHAFT) Single Sided -(Wall Mounted
sign: As pr your Design, 3mm ACP Sheets vinyl pasting ACP
140 Sheets) No 50
ap) Providing & Fixing (FIRE HOSE REEL) Single Sided -(Wall
Mounted sign: As pr your Design, 3mm ACP Sheets vinyl pasting
143 ACP Sheets) No 50
ar) Providing & Fixing (FIRE ALARM PANEL) Single Sided -(Wall
Mounted sign: As pr your Design, 3mm ACP Sheets vinyl pasting
145 ACP Sheets) No 4
n) Supply of 24U Network Rack with front door, rear steel door,
800 x 800mm castor wheels, AC power supply Horizontal with 6
sockets- 2 nos, 2 fans, earthing kit including all accessories
192 related to installation. Nos 4
193 o) POE network switches 8 Port Nos 10
194 p) POE network switches 24 Port Nos 1
195 q) Wifi Access Points Nos 50
r) Supply and fixing of 2mm thick heavy duty FRLS PVC conduits
of following sizes including cost of junction boxes, bends, elbows,
sockets, tees etc. laying in slab, cutting chasis and making good
196 including all fixing hardware. (i) 20 mm dia 2mm thick PVC RM 2000
197 s) 25 mm dia 2mm thick PVC RM 2000
198 t) Server Nos 1
EQUIPMENT:- 1) Supply ,unloading at site,handling, installation,
testing & Commissioning of a)IP EPBAX system suitable as per
specification and as described below . (IP Communications
system with Duplex mode, Change in Architecture: Unlike
previous EPABX versions, IP EPABX has to an Open Software
Architecture.
1. Hardware : The IP EPABX should now run on
• Proprietary compact PCI (cPCI) hardware
• COTS (Commercially off-the-shelf / Industry Standard) Server
new 2. Software:
IP EPABX Should offers a highly reliable software architecture
running on high availability
Linux operating system (SUSE Linux Enterprise Server 11 SP1, 64
bit).
EPABX Software control functions include
• Call Control
• CSTA Application Control
• Admin and Service
• High Availability Control,IP - Ready with IP gateway inbuilt to
connect 120 IP Phones , Unified Messaging platform Inbuilt
(Faxmail, E-mail & Voice mail intregartion ): A single multi-media
mailbox, IP - Phone ( Licences): Licences in the system, Analog
extension Ports , Digital Ports, PRI lines (10 channel each),
199 Analog Trunks, BRI ISDN Lines,(i) EPBAX as described above set 1
11) Providing and fixing of C.I. wafer type check valve suitable
for working pressure of 15 kg/sqcm with flanges, Nut, bolts &
289 washers, painting etc. complete as required. a) 65 mm dia NOS 25
290 b) 80 mm dia NOS 15
291 c) 100 mm dia NOS 15
292 d) 150 mm dia NOS 15
293 e) 200 mm dia NOS 5
294 f) 250 mm dia NOS 5
17) Providing & fixing 80mm dia gun metal single headed fire
hydrant landing valve with flanged inlet, brass spindle
controlled 63 mm dia female instantaneous outlet type. G.M.
coupling, blank cap, chain, twist release type lug & all accessories
Conforming to IS:5290. Including fixing and flanged tapping
from wet riser and providing pressure gauge with gun metal ball
311 valve complete as required. NOS 21
18) Providing and fixing 8mm thick Orifice plate complete in S.S.
to reduce pressure upto 3.5 Kg/sqcm complete in all respects
312 with flanges, nut, bolts, etc. a) 80 mm dia NOS 10
313 b) 100 mm dia NOS 10
19) Providing & fixing swinging type First Aid hose reel rolled on
red colour drum with 36 mts long and 20 mm dia heavy duty
Thermoplastic hose (type II / rubber water hose, 20 mm dia stop
cock, terminating with G.M. coupling & nozzle of 6mm outlet
with shut off valve confirming to IS 8090 - 1976 complete with
MS socket for tap-off, drum and brackets for fixing on wall with
anchor fastner, bolts & nuts conforming to IS:884-1969
314 complete as required. NOS 18
20) Providing & fixing non-perlocating, rubber reinforced lined
fire hose pipe for internal fire hydrant (as per IS : 636) of 63 mm
dia and length as described below. The hose shall be rated for
brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI
marked brass male & female coupling (IS:903) bound & rivetted
to hose pipe with copper rivets & 1.5 mm copper wire (Location :
315 Internal fire hydrant) a) 15 m length NOS 36
21) Providing & fixing controlled perlocation fire hose pipe for
external fire hydrant (as per IS:8423) of 63 mm dia and 15 meter
length rated for brust pressure of 35.7 Kg/sqcm. The hose shall
be tested for flame resistance test in accordance to IS:8423. Hose
shall be complete with ISI marked brass male & female coupling
(IS:903) bound & riveted to hose pipe with copper rivets & 1.5
316 mm copper wire (Location : External fire hydrant) NOS 14
27) Providing and fixing 6 mm thick glass door of size 2.1m x 0.9m
along with anodised aluminium frame with centre opening for
FHC. Suitably marked on the outside with the letters "FIRE HOSE"
including 'looking arrangement. (Vendor shall submit the shop
drawing / sample for approval of Interior Designer / Architect /
322 Owner before dispatching the material). Nos 14
28) Providing & fixing external fire hose cabinet complete in SS,
fabricated from 16g SS 304 sheet with full front glass door and
locking arrangement duly painted and suitably mounted on a
raised masonry platform / supported from the wall as required
323 (Approx size 750mm x 750mm x 450mm) NOS 7
34) 'Providing and fixing of ABC , Clean Agent Gas type Fire
Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with
pressure indicating gauge, internal tube, squeeze lever type valve
fully charged complete in all respects including wall suspension
329 bracket and confoming to IS:1349-1993 a) Capacity 5 Kg NOS 7
330 b) Capacity 10 Kg NOS 5
Kitchen ducting 16G thick mild steel with all accessories as per
specifications. (with clean outs as per NFPA at base of vertical
riser and change in direction and maximum at every 6.1 M in
392 horizontal) Sqm. 100
408 ii) 19 mm thick for Supply air duct not surrounded by return air Sqm 850
409 iii) 9 mm thick for Return air duct Sqm 300
428 d) PLC Panel for Controlling 6 Nos of jet Fans is Basement 2 Nos 1
429 e) Co Sensor for Controlling 6 Jet Fan Basemnt 1 Nos 6
430 f) Co Sensor for Controlling 6 Jet Fan Basemnt 2 Nos 6
431 g) CFD Analaysis Basement 01 Nos 1
432 h) CFD Analaysis Basement 02 Nos 1
3) Providing & laying cement concrete 1:4:8 for RCC NP2 class
pipes for storm water system including bedding and haunches
upto the center of pipe as per approved working drawings
including shuttering & timbering complete as required b) 200
25 mm dia (with 150 mm thick bedding) RM 25
26 c) 300 mm dia (with 150 mm thick bedding) RM 50
27 d) 450 mm dia (with 150 mm thick bedding) RM 50
5) 'Providing & fixing gun metal horizontal flap type non return
valve conforming to IS 778 and suitable for working pressure of
10 Kg / Sqcm. Including rubber gasket, flanges, union, nuts,
60 bolts & washers complete as required. a) 32 mm dia NOS 1
61 b) 40 mm dia NOS 1
62 c) 50 mm dia NOS 2
63 d) 65 mm dia NOS 2
64 e) 80 mm dia NOS 3
65 f) 100 mm dia NOS 2
66 g) 150 mm dia NOS 1
10) Providing & fixing on line digital type flow meter with
preamplifier & microprocessor based electronic flow meter
mounted in plumbing plant room electrical control panel with
the following features. Monitoring the total flow, Flow rate, high
low arm batching and blending etc. Including electrical wiring
from preamplifier to microprocessor based flow meter.
Complete with all type of Plumbing & Electricla connections,
accessories, wiring, conduits & supports complete with all
respect. The signal read out shall be 4-20 m.amps to be received
as BAS.(PTSE). Flow meter should be compatible to BMS
79 system.a) 65 mm dia NOS 2
80 b) 80 mm dia NOS 2
81 c) 100 mm dia NOS 1
12) Providing & fixing Auto Air vent with ball valve for cold / hot
water supply risers, suitable for working pressure of 10 Kg/Sq.cm.
83 'a) 15 mm dia NOS 5
13) Supply, installing and testing of nitrile rubber insulation for
exposed & concealed hot water supply pipes and fittings, strainer
84 and valves etc. a) 15 mm dia pipe --- SP insulation 9 mm thick RM 60
85 b) 20 mm dia pipe --- SP insulation 9 mm thick RM 60
86 c) 25 mm dia pipe --- SP insulation 9 mm thick RM 20
87 d) 32 mm dia pipe --- SP insulation 13 mm thick RM 20
88 e) 40 mm dia pipe --- SP insulation 13 mm thick RM 5
89 f) 50 mm dia pipe --- SP insulation 19 mm thick RM 20
90 g) 65 mm dia pipe --- SP insulation 25 mm thick RM 10
91 h)80 mm dia pipe --- SP insulation 25 mm thick RM 15
92 i)100 mm dia pipe --- SP insulation 25 mm thick RM 50
93 j)150 mm dia pipe --- SP insulation 25 mm thick RM 50
14) 'Providing & fixing butterfly valve with hand lever operation
& above with gear box operation). suitable for working pressure
of 10 Kg / Sqcm.Including rubber gasket, flanges, nuts, bolts,
washers & painting complete as required for hot water system
94 and insulation as per item no. 24. a) 80 mm dia NOS 8
95 b) 100 mm dia NOS 6
96 c) 150 mm dia NOS 5
15) Providing & fixing gun metal globe valve with CI hand wheel
union flanges,washer nuts & bolts rated to a temperature of 85
Deg C & suitable for pressure 15 kg/sqcm with LRB machine
stiched matteresses insulation 50 mm thick of density 150kg /
cum backed with hexagonical wire netting on one side. And tying
97 with GI wire to hold the matteresses. a) 15 mm dia NOS 5
98 b) 20 mm dia NOS 5
99 c) 25 mm dia NOS 5
100 d) 32 mm dia NOS 2
101 e) 40 mm dia NOS 2
102 f) 50 mm dia NOS 4
103 g) 65 mm dia NOS 2
104 h) 80 mm dia NOS 5
105 i) 100 mm dia NOS 5
106 j) 150 mm dia NOS 2
16) Providing and fixing 22 SWG Al. sheet cladding over nitrile
rubber insulation on hot water pipe work including valves and
fittings for the following size pipes.a) 15 mm dia to 40 mm dia
107 pipe RM 50
108 b) 50 mm dia to 80 mm dia pipe RM 75
109 c) 100 mm dia to 150 mm dia pipe RM 50
17) Providing, fixing, jointing and testing in position the following
U-PVC pressure pipes as per ASTM D 1785 with threaded /
solvent cement joint fitting, including all necessary fittings and
specials such as bends, tees, union, reducers, flanges and plugs
etc. The pipes and fittings shall be suitable of working pressure
of 10 Kg/Sq.cm and making good the same complete as required
(All pipes sizes shall be considered as internal dia of pipe and pipe
110 shall be used for external water supply services)b) 50 mm dia RM 200
111 c) 65 mm dia RM 25
112 d) 80 mm dia RM 30
113 e) 100 mm dia RM 50
114 f) 150 mm dia RM 50
18) Providing trenching upto required depth but not less than 1
mt. deep for embedded GI/CU/CILA/PVC pipes and fittings.
Providing 100 mm thick fine sand filling all round the pipe.
inlcuding excavation in all kind of soil (hard rock), dewatering
refilling, watering, ramming and removing the surplus excavated
material and making good the same as per Architect
115 requirement.a) Pipe Upto 150 mm dia RM 250
21) Providing and fixing hinges type DI manhole cover with frame
(EN:124 standard) of the following sizes: a) Size 450mm x
120 450mm(MD) NOS 15
121 b) Size 600mm x 600mm(HD wt. 90 kg) NOS 15
22) Making connection from Existing Municipal Water Supply line
including necessary excavation in all kind of soil & making good
the same including boring and tapping the Existing Municipal line
by providing and installing ferrule and other necessary fittings as
required. The rate for this item also includes complete services
from the contractor for liasoning works such as filing necessary
applications submission of forms for approval to the municipal
authorities, depositing the fees and other amounts as
required for getting the inspection / approval / installations
including all the expenses incurred in authorities, following up
this regards shall be borne by the Contractor except for the
payments to be made for any security deposit etc. which will
122 be reimbursed on production of original voucher. L.S. 1
9) Supply, Fixing C.P. brass towel rail with C.P. brass wall brackets
& C.P brass screws complete as required.9.1) Supply, fixing Size
131 600 x 20 mm size Nos. 13
132 10) Supply, Fixing C.P. brass Towel ring Nos. 13
11) Supply, Fixing recessed type S.S. soap dish with grab bar with
133 PVC rawl plug & C.P. brass screw complete as required. Nos. 13
12) Supply, Fixing push type liquid soap dispenser with PVC rawl
134 plug & C.P. brass screw complete as required. Nos. 8
11) Providing and fixing S.S. R.O. water storage tank, with inlet,
outlet, overflow, manhole with cover and vent connections etc.
One at terrace level and one in Plumbing plant room a) Capacity
159 1500 litres NOS 2
3) Providing and fixing heavy duty solenoid valve with flow range
171 of 5-120 gpm with pressure range of 20-150 PSI - 50mm dia. No. 50
12) Providing & Fixing of Disc Filter with capacity matching pump
design flow having an suitable inlet connections , to create a
helical effect in the incoming water ,spinning particulate in
suspension away from the filtering element and so minimizing
cleanings frequency ,3/4" outlet for flushing at bottom of filter &
180 maximum working presure of 12 Bars. No. 1
13) Providing & Fixing of Monobloc or openwell submercible
pumpset of having discharge and head of design flow with
181 control pannel No 1
121800
101500
101500
101500
121800
70000
1955458
107550
3000
3000
11736
8400
11736
11736
20256
20256
10800
43200
43200
54000
54000
21600
24000
19429974
Sub total
VAT @ 13%
Total Rs. With VAT