9.1 Supply and install Supply air Ceiling Diffuser SCD with
internally insulated plenum boxes as per drawings. from GGC or
equal
9.1.1 600 x 600 mm (24 x 24) Inch No. 650 -
9.1.2 450 x 450 mm (18 x 18) Inch No. 500 -
9.1.3 300 x 300 mm (12 x 12) Inch No. 350 -
9.1.4 225 x 225 mm (9 x 9) Inch No. 300 -
9.1.5 150 x 150 mm (6 x 6) Inch No. 250 -
9.2 Supply and install Return air Ceiling Diffuser RCD, with
internally insulated plenum boxes unless it is not connected to
return duct, as per drawings. from GGC or equal
To Bill Summary
9.3 Supply and install Exhaust air Ceiling Diffusers ECD with
plenum boxes internally insulated, as per drawings. from GGC or
equal
9.3.1 225 x 225 mm (9 x 9) Inch No. 275 -
9.3.2 150 x 150 mm (6 x 6) Inch No. 210 -
9.4 Supply and install Supply Linear Slot Diffusers LSD including
plenum boxes with internally insulation, as per drawings. from
GGC or equal
9.4.1 2 slot x 1 m No. -
9.4.2 3 slot x 1 m No. -
9.5 Supply and install Linear Bar air Supply Grill LBSG including
plenum boxes with internally insulation as per drawings. from
GGC or equal
9.5.1 1000 x 150 mm No. -
9.5.2 1500 x 200 mm No. -
9.6 Supply and install Return Linear Slot Diffusers RLSD including
plenum boxes with internally insulation unless it is not connected
to a return duct, as per drawings. from GGC or equal
9.7 Supply and install Linear Bar air Return Grill LBRG including
plenum boxes with internally insulation unless it is not connected
to a return duct, as per drawings. from GGC or equal
9.8 Supply and install Intake air Sand Trap Louver STL as per
drawings. from GGC or equal
9.8.1 2000 x 600 mm No. -
9.8 Supply and install Exhaust air Sand Trap Louver ESTL as per
drawings. from GGC or equal
9.8.1 2000 x 600 mm No. -
To Bill Summary
To Bill Summary
11.2 Supply, install, set to work and commission chemical dosing pot Item -
assembly (00 litres) including 1" dia. ball valves for filling, inlet
line, outlet line, and drain. Filling funnel with cap, automatic air
vent with cock, and all other accessories needed to finalise the
work as per drawings. From METITO or equal
11.3 Air Separator including gate valves for inlet, outlet and by-pass,
automatic air vent with cock, drain valve, and othe accessories
needed to finalise the work as per drawings. From TACO or equal
11.5 32 mm dia. water supply isolation valve for make-up water No. -
To Bill Summary
14.0 Supply, installation, test and setting to work condensate drain item -
piping of AC machines connected to nearest drain point with
fittings and accessories completely
AA Mechanical Identification:
Supply and install approved services identification tags, markings item -
and flow direction arrows.
BB Civil Works
Provide for associated civil works required for the Mechanical job -
Services Installation as described and listed in this B of Q and as
shown on the drawings. The works shall include the formation of
all holes for the services to pass through etc., and the sealing of
the holes once the services have been installed. Provide structural
supports / framing for the WU, EU & ACU, EF at height such as
to allow for the installation of P- trap for condensate drain lines.