Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

Sanjeevini

hospital
narsipatnam
13.06 kWp
(17.66120, 82.62176)

Doctor

Click to View 3D Model

vamsi@effisolenergy.com
The Solar Labs 09492100669
Generated with The Solar Labs effisolenergy.com
About Us We “Effisol Energy Solutions Private Limited” are acknowledged
organization, are engaged as manufacturer of Solar Panel, Solar Power Plant,
Solar Water Heater, Solar Power System and many more. It was established
in the year 2016 at Visakhapatnam, Andhra Pradesh. The products which are
manufacture are mostly appreciated by our clients for their astonishing finish,
luminous quality and cost efficient nature.

The Solar Labs


Generated with The Solar Labs
System
Metrics ANNUAL PERFORMANCE SPECIFIC
PRODUCTION RATIO GENERATION

18.93 74.22% 1448.9


x 1000 kWh (Units) kWh/kWp/year

Module DC Nameplate AC Nameplate

13.06 kWp 13.00 kW

Load Ratio Weather Dataset

1.00 Meteonorm

The Solar Labs


Generated with The Solar Labs
Components Modules

Your installation uses latest technology Waaree Energies Ltd Aditya Series WS-300-350 WS-335 39 No.
in solar

Inverters

Waaree W3-5K 2 No.

Polycab PSIS -3K 1 No.

Structure

Premium Structure

The Solar Labs


Generated with The Solar Labs
Components BOS

Your installation uses latest technology DC Distribution Box


in solar
AC Distribution Box

Earthing

Lightning Arrestor

The Solar Labs


Generated with The Solar Labs
Monthly
Production
During first year of operation, your
system will produce 18.93 x 1000
units over the year

Expected average generation of


the system
1577.47 kWh/month
Yearly degradation rate
1.5%/year
Monthly Table
Months GlobDirect GlobDiffuse GlobEff EArray (kWh) EGrid (kWh) Spec Gen PR
(kWh/m2) (kWh/m2) (kWh/m2)

January 149.5 55.8 173.9 1843.1 1665.54 127.48 73.31


February 153.7 56.1 170.59 1812.49 1637.87 125.36 73.49
March 185.6 69.9 196.62 2098.93 1896.72 145.18 73.84
April 192.2 80.1 191.17 2046.2 1849.07 141.53 74.03
May 188.2 92.7 179.93 1930.0 1744.06 133.49 74.19
June 147.0 88.1 139.0 1509.41 1363.99 104.4 75.11
July 141.7 93.5 134.96 1481.77 1339.02 102.49 75.94
August 140.3 87.0 136.72 1501.06 1356.45 103.82 75.94
September 142.9 76.5 145.4 1581.76 1429.37 109.4 75.24
October 152.0 76.8 162.98 1757.58 1588.25 121.57 74.59
November 139.1 53.0 160.5 1682.15 1520.09 116.35 72.49
December 138.3 54.1 162.57 1703.3 1539.2 117.81 72.47
Annual 1870.5 883.6 1954.34 20947.75 18929.63 1448.88 74.22

The Solar Labs


Generated with The Solar Labs
Field Segments
Orientation Tilt Azimuth Row Spacing Frame Size Modules Power

Portrait 15 197.82 2 ft 6.08 in 1x1 4 1.34 KW


Portrait 15 197.82 2 ft 6.08 in 1x1 5 1.68 KW
Portrait 15 197.82 5 ft 0.59 in 2x1 18 6.03 KW
Landscape 15 197.68 3 ft 10.34 in 3x1 9 3.02 KW
Landscape 15 197.68 1 ft 3.2 in 1x1 2 0.67 KW
Portrait 15 197.82 2 ft 6.08 in 1x1 1 0.34 KW

The Solar Labs


Generated with The Solar Labs
Shadow Analysis
June 21  9:00 AM June 21  05:00 PM

The Solar Labs


Generated with The Solar Labs
Shadow Analysis
December 22  9:00 AM December 22  05:00 PM

Conclusion: Panels are shadow free for 98.03% of solar time throughout the year.

The Solar Labs


Generated with The Solar Labs
Heat Map Solar Access

The Solar Labs


Generated with The Solar Labs
Losses
Loss in generation predicted due
to environmental and electrical
factors
Impact
on CARBON DIOXIDE EQUIVALENT COAL BURN

Environment OFFSET ACRES OF FOREST AVOIDED

You are contributing to solve

280.7 329.6 139


Earth's biggest problem - Global
Warming.

metric tons acres/year metric tons

Equivalent Number of Trees Planted Petrol Consumption Avoided

4646 trees 119742.0 litres

Equivalent Kilometers Driven

1103920.7 kms

The Solar Labs


Generated with The Solar Labs
Thank you
Effisol Energy Solutions
vamsi@effisolenergy.com
09492100669
effisolenergy.com

The Solar Labs


Generated with The Solar Labs

You might also like