NH3 Base Case NH3 with PZ NH3 with PZ RSS NH3 with PZ RVC

CO2 at Flue gas 103.3442 kg/h 103.3442 kg/h 103.3442 kg/h 103.3442 kg/h
CO2 at Treated Gas (a 11.96898 kg/h 2.762855 kg/h 1.512513 kg/h 4.231249 kg/h
CO2 Capture efficienc 88.41833 % 97.32655 % 98.53643 % 95.90567 %
Heat Ex duty 9.28E+05 kJ/h 1.58E+06 kJ/h 9.28E+05 kJ/h 9.28E+05 kJ/h
Cooler duty 1.26E+06 kJ/h 1.40E+07 kJ/h 4.04E+06 kJ/h 4.50E+05 kJ/h
Reboiler duty 1.17E+06 kJ/h 2.22E+07 kJ/h 1.07E+06 kJ/h 1.03E+06 kJ/h
Condenser duty 3.59E+03 kJ/h 4.07E+07 kJ/h 2.31E+03 kJ/h 2.69E+03 kJ/h
Pump duty 8.11E+02 kJ/h 6.87E+03 kJ/h 7.99E+02 kJ/h 7.89E+02 kJ/h
Compressor duty 0.00E+00 kJ/h 0.00E+00 kJ/h 0.00E+00 kJ/h 2.98E+04 kJ/h

Overall duty 3.36E+06 kJ/h 7.85E+07 kJ/h 6.04E+06 kJ/h 2.44E+06 kJ/h

Overall duty requirement CO2 Captu


9.00E+07 100
7.85E+07 98
8.00E+07

CO2 Capture Efficiency (%)


7.00E+07 96
Overall Duty (kJ/h)

6.00E+07 NH3 Base 94


NH3 with PZ 92
5.00E+07
NH3 with pz RSS
4.00E+07 90
NH3 with RVC
3.00E+07 NH3 with LVC 88
2.30E+07
2.00E+07 86

1.00E+07 6.04E+06 84
3.36E+06 2.44E+06
0.00E+00 82

Simulation Cases Simulation Cas


NH3 with PZ LVC

103.3442 kg/h
3.312391 kg/h
96.7948 %
9.09E+05 kJ/h
5.01E+06 kJ/h
1.18E+07 kJ/h
5.23E+06 kJ/h
7.99E+02 kJ/h
5.18E+04 kJ/h

2.30E+07 kJ/h

CO2 Capture Efficiency


0
8
6
4 NH3 Base
NH3 with PZ
2
NH3-PZ with RSS
0 NH3-PZ with RVC
8 NH3-PZ with LVC
6
4
2
Simulation Cases