Current Transducer LAX SERIES
Current Transducer LAX SERIES
For the electronic measurement of currents: DC, AC, pulsed .... , with a galvanic isolation
between the primary circuit (high power) and the secondary circuit (electronic circuit).
Maxi. 16.5 mm
Features Applications
• Closed loop (compensated) current transducer using the • AC variable speed drives and servo motor drives
hall effect • Static converters for DC motor drives
• Printed circuit board mounting • Battery supplied applications
• Isolated plastic case recognized according to UL 94-V0 • Uninterruptible Power Supplies (UPS)
• Multirange with a single device: 16, 25, 33, 50 and 100 A rms • Switched Mode Power Supplies (SMPS)
• 3 independent primary jumpers. • Power supplies for welding applications.
Advantages Standards
• Excellent accuracy • EN 50178
• Very good linearity • UL508 - UR marking
• Low temperature drift • IEC 61010-1-safety.
• Optimized response time
• Wide frequency bandwidth
• No insertion losses
• High immunity to external interference
• Current overload capability
• Height less than 16.5 mm for a simplified integration with Application Domain
power modules • Industrial.
• Low primary inductance.
Page 1/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
Electrical data
At TA = 25°C, VC = ± 15 V and RM = 50 Ω, NP = 1 turn, high speed PCB design (see page 11), unless otherwise noted.
Parameters with a * in the conditions column apply over the - 40°C.. 85°C ambient temperature range.
Parameter Symbol Unit Mini Typ Maxi Conditions
Primary nominal current rms IPN At 100 Apply derating according to fig. 2
Current consumption IC mA 10 + IS 12 + IS
31 65 after a cycle to 50 A
Primary turns NP 1 3
Page 2/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
100 A up to T A = 70°C.
Prim a ry AC current rm s (3 prim a ry jumpers
IPN A Linear derating to 70 A at 85°C.
in parallel)
See figure 2
100 A up to T A = 50°C.
Prim a ry continuous direct current (3 primary jumpers
IPN DC A Linear derating to 50 A at 85°C.
in parallel)
See figure 2
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended
periods may degrade reliability.
Page 3/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
Isolation characteristics
Symbol Unit Value
The transducer can be used according to EN 50178 and IEC 61010-1 standards under following conditions
(for example):
• Rated isolation voltage: 600 V
• Reinforced isolation
• Over voltage category OV III
• Pollution degree PD2
• Non-uniform field
The creepage distance and clearance of the transducer mounted on a PCB are greater than 8 mm only if the primary
circuit tracks stay out of the shaded area shown below:
Figure 1: zone not permitted for primary tracks (to guarantee rated creepage and clearance)
Page 4/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
120 600
100 400
Mini
200
current (At)
80
60 AC 0
250
Maximum measuring resistance
60 Vc = ±15 V ±5%
(DC current only) (Ohm)
Vc = ±12 V ±5%
50 TA = -40 .. 85 °C 200
40
150
(Ohm)
30
100
20
50
10 TA = -40 .. 85 °C
0 0
11.5 12.5 13.5 14.5 15.5 0 50 100 150 200
Maximum power supply Vc (V) Measuring range (At)
0.8 11
Typical consumption current
9
(mA)
0.4
0.2 8
TA = 25 °C, IP = 0
TA = 25 °C
0.0 7
0 50 100 150 11 12 13 14 15 16
Measuring range (A) Supply voltage (± V)
Page 5/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
0.1
0.1
0.05
0.05
0 0
-100 -50 0 50 100 -100 -50 -0.05 0 50 100
-0.05
-0.1
-0.1 -0.15
Primary current (A)
Primary current (A)
Figure 8: Typical linearity error for Figure 9: Typical linearity error for
high speed 1 turn PCB design low speed 1 turn PCB design
1 0 6 20
0 -5 4 0
Gain (dB)
Gain (dB)
Phase (°)
Gain
Phase (°)
-1 -10 2 -20
Gain
Phase
-2 Phase -15 0 -40
IP = 25 A
-3 -20 -2 IP = 1.6 A -60
-4 -25 -4 -80
100 1000 10000 100000 1000000 10000 100000 1000000
Frequency (Hz) Frequency (Hz)
Figure 10: Typical frequency response Figure 11: Typical frequency response
(high speed 1 turn PCB design) (high speed 1 turn PCB design)
(IP = 25 A) (IP = 1.6 A)
1 0 6 20
0 -5 4 0
Gain (dB)
Phase (°)
Gain (dB)
2 Gain -20
Phase (°)
-1 -10
Gain Phase
-2 -15 0 -40
Phase
-3 -20 -2 -60
IP = 1.6 A
IP = 25 A
-4 -25 -4 -80
100 1000 10000 100000 1000000 10000 100000 1000000
Frequency (Hz) Frequency (Hz)
Figure 12: Typical frequency response Figure 13: Typical frequency response
(low speed 1 turn PCB design) (low speed 1 turn PCB design)
(IP = 25 A) (IP = 1.6 A)
Page 6/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
200 ns/div
Figure 15: Typical di/dt follow-up Figure 16: Typical di/dt follow-up
(low speed 1 turn PCB design) (low speed 1 turn PCB design)
Page 7/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
+VC At zero input current, the model for the offset is reduced to:
C1
+
M IS RM IS = IOE + IOT(TA) + IOM(ΘPmaxi)
IP 0V
In which IOM(ΘPmaxi) is the magnetic offset current due to the
C2 maximum input ampere-turns that have been applied to the
transducer.
-
-VC
Sensitivity and linearity
Figure 17 : standard characterization schematics
To measure sensitivity and linearity, the primary current (DC) is
cycled from 0 to IP, then to -IP and back to 0 (equally spaced IP/
Ampere-turns and amperes 10 steps).
The sensitivity G is defined as the slope of the linear regression
The LAX transducer is sensitive to the primary current linkage line for a cycle between ± IPN.
ΘP (also called ampere-turns). The linearity error εL is the maximum positive or negative
difference between the measured points and the linear regression
ΘP = NPIP (At) line, expressed in % of the maximum measured value.
Page 8/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
Ip Is
The temperature variation I OT of the electrical offset current
IOE is the variation of the electrical offset from 25°C to the tr
considered temperature:
1 0 %
I (T ) = I OE (T ) − I OE (25°C )
OT
tra t
Note: the transducer has to be demagnetized prior to the
application of the current cycle (for example with a
demagnetization tunnel). Figure 19: response time tr and reaction time tra
Overall accuracy
The overall accuracy at 25°C XG is the error in the - IPN .. + IPN
range, relative to the rated value IPN.
It includes:
• the electrical offset IOE
• the sensitivity error εG
• the linearity error εL (to IPN)
The magnetic offset is part of the overall accuracy. It is
taken into account in the linearity error figure provided the
transducer has not been magnetized by a current higher
than IPN.
Page 9/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
Application data
The LAX 100-NP has been designed to be used at nominal currents from 16 to 100 A. The 3 primary jumpers allow the
adaptation of the number of primary turns NP to the application so as to achieve the best compromise between nominal
current, measuring range and secondary current:
Primary Primary
Primary Secondary Primary
Number of current, coil
nominal nominal insertion Connections (see PCB
primary turns measuring resistance
current rms current rms inductance layout )
NP range @ 20°C
IPN (A) ISN (mA) LP (nH)
IPM (A) RP (µΩ)
IN
100 1 50 160 90 15
OUT
IN
50 1 25 160 90 15 OUT
IN
33.3 2 33.3 80 400 60 OUT
IN
33.3 3 50 53 800 136 OUT
IN
25 2 25 75 400 60 OUT
IN
16.7 3 25 50 800 136 OUT
See also the paragraph "performance parameters definition: transducer simplified model" for more details about ampere-
turns and output current.
IP IP
Page 10/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
LAX series 16-100 A
Page 11/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions LAX 100-NP (in mm. General linear tolerance ± 0.15 mm)
Remarks
• IS is positive (sourcing) when IP flows in the direction of the arrow
Caution, risk of electrical shock
• Mass: 20 g
When operating the transducer, certain parts of the module can carry
hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be
inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 12/12
070213/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com