Features
Draining Pump
Built-in draining pump to make sure condensed water drain out reliably.
1.6 Terminals for alarm lamp and long-distance on-off controller connection are
standard
Reserve terminals for the connection of alarm lamp and long-distance on-off controller, more human
control.
Alarm lamp
Long-distance on-off controller
19
Dimensions
2. Dimensions
92 92
D
75 Fresh air intake
80
D
A 80
136
4-install hanger 126
D 680 Body
D 91
Gas side
Liquid side
90
135
Wiring connection port
E-parts box
92 92 92 92
92 92 92 92
A
A
780
780
840
B
A
A
Service hole for
Test mouth & Test cover
draining pump 32 Drain hole
132
D
B 680 D
840 196
C
A A
D
B
D
92 92 92 92
Panel
950
950 55
Unit: mm
Model A B C D
18/24 160 75 205 50
30~48 160 95 245 60
20
Service Space
3. Service Space
>1000mm
>1000m m
>1000m m
>1000mm
21
Wiring Diagrams
4. Wiring Diagrams
AW-CFM024-N11;AW-CFM036-N11
22
Indoor Units
AW-CFM036T-N11
23
Wiring Diagrams
AW-CFM048-N11
24
Indoor Units
5. Electric Characteristics
Notes:
MFA: Max. Fuse Amps. (A)
25
Sound Levels
6. Sound Levels
1.4m
Microphone
26
Indoor Units
7. Accessories
Bolt M5 4
Out-let pipe 1
Owner's manual 1
Others Installation manual 1
Network wires 1
27
The Specification of Power
Heating pump:
Indoor/Outdoor
Strong Electric 2×1.0 3×1.0
Connecting Wiring (mm2) 3×1.0 3x1.0/3×1.5 3x1.0
Signal
(2×0.75/
Weak Electric Signal (2×0.2) (2×0.2)
2×0.5)
28
Indoor Units
9. Field Wiring
AW-CFM012-N11; AW-CFM018-N11
AW-CFM024-N11,AW-CFM036-N11
29
Field Wiring
AW-CFM024-N11
AW-CFM036-N11
30
Indoor Units
AW-CFM036T-N11
AW-CFM048-N11
31
DFM Duct Type
1.Features ............................................................................ 33
2.Dimensions ...................................................................... 35
5.Static Pressure................................................................. 41
32
Features
1. Features
1.1 Slim Design
The industry Lowest height is designed to be fitted into tight roof spaces.
*18K unit - 210mm,24K/30K unit - 249mm,36K unit -300mm
Air intake from rear (Standard) Air intake from bottom (Optional)
33
Features
Max 750mm
34
Dimensions
2. Dimensions
18K 880 210 674 600 140 706 50 136 782 190 40 920 508 78 148 88 112
24K~36K 1100 249 774 700 140 926 50 175 1001 228 5 1140 598 80 150 130 155
48K~60K 1200 300 874 800 123 1044 50 227 1101 280 5 1240 697 80 150 185 210
35
Service Space
3. Service Space
Ensure enough space required for installation and maintenance.
There is enough space for installation and maintenance. The ceiling is horizontal, and its structure can
endure the weight of the indoor unit. The outlet and the inlet are not impeded, and the influence of external
air is the least. The air flow can reach throughout the room. The connecting pipe and drainpipe could be
extracted out easily. There is no direct radiation from heater.
36
Wiring Diagrams
4. Wiring Diagrams
AW-DFM018-N11
AW-DFM018-N11
37
Wiring Diagrams
AW-DFM036-N11
AW-DFM036T-N11
38
Wiring Diagrams
AW-DFM048-N11
39
Wiring Diagrams
AW-DFM060-N11
40
Static Pressure
5. Static Pressure
18K
1200
1000
Air Flow Rate(m³/H)
800
600 H
M
400 L
200
0
0 25 37 50 80 100
External Static Pressure(pa)
24K
1600
1400
1200
Air Flow Rate(m³/h)
1000
800 H
M
600 L
400
200
0
0 20 40 60 80 100 120 140 160
External Static Pressure (Pa)
41
Static Pressure
30K,36K
2500
2000
Air Flow Rate(m³/h)
1500
SH
H
1000 M
L
500
0
0 20 40 60 80 100 120 140 160 180
External Static Pressure (Pa)
48K, 60K
3000
2500
Air Flow Rate(m³/h)
2000
1500 H
M
1000 L
500
0
0 20 40 60 80 100 120 140 160 180
External Static Pressure (Pa)
42
Electric Characteristics
6. Electric Characteristics
Indoor Units Power Supply
Model
Hz Voltage Min. Max. MFA
AW-DFM018-N11 50 220-240V 198V 254V 20
AW-DFM024-N11 50 220-240V 198V 254V 25
AW-DFM036-N11 50 220-240V 198V 254V /
AW-DFM036T-N11 50 220-240V 198V 254V /
AW-DFM048-N11 50 380-415V 342V 436V 25
AW-DFM060-N11 50 380-415V 342V 436V 25
Note:
MFA: Max. Fuse Amps. (A)
43
Sound Levels
7. Sound Levels
Discharge Suction
Duct Duct
1.4m
Microphone
44
Accessories
8. Accessories
Name Shape Quantity
Soundproof/insulation sheath 2
Seal sponge 1
Owner's manual 1
others
Installation manual 1
45
The Specification of Power
Heating pump:
Model(KBtu/h) 18 24 30-36
Phase 1-phase 1-phase 1-phase
Power
Frequency and Voltage 220-240V, 50Hz
Circuit Breaker/ Fuse (A) 25/20 32/25 50/40
Indoor Unit Power Wiring (mm2) 3×2.5 3×2.5
Ground Wiring 2.5 2.5 4.0
Outdoor Unit Power Wiring 3×2.5 3×2.5 3×4.0
Indoor/Outdoor Connecting Wiring (mm2)
Strong Electric Signal 2×1.0 3×1.0 3×1.0/
3×1.5
Weak Electric Signal (2×0.75/2×0.5) (2×0.2) (2×0.2)
Model(KBtu/h) 36 48/ 60
46
Field Wiring
AW-DFM024-N11
47
Field Wiring
AW-DFM036-N11
AW-DFM036T-N11
48
Field Wiring
AW-DFM048-N11;AW-DFM060-N11
49
Ceiling & Floor Type
2.Dimensions ...................................................................... 52
50