Professional Documents
Culture Documents
Lifting Lug
Lifting Lug
Lifting Lug
tL
rL d
TL htl
hp
r hc
b Wp
a tp
Lp
SUMMARY
NOTE : * - Operating Liquid height, H for shell = + 366 mm from bottom tan line of vessel.
CENTER OF GRAVITY
x plane
Vessel ( Head ) COG
ID 1219 mm
thk 15 mm
Head N axis 178 mm
TL/TL 2438 mm y plane
Skirt height * 1220 mm 3 1
COG In y plane
SOD
Bid
Bod
General Data
Skirt OD = 1249 mm
Skirt Thickness = 10 mm
Basering OD,Bod = 1471 mm
Basering ID, Bid = 1071 mm
Basering Thickness = 20 mm
Empty Weight = 3270 kg
Operating Weight = 3919 kg
Hydrotest Weight = 6592 kg
Max. wind load (from PVELite Wind Load Calc) = 1420.64 N
Wind Area (from PVELite Wind Load Calc) = 3.79E+06 mm2
Wind Pressure, qs = wind load/wind area = ### N/mm2
Axial Force = max. weight*9.81 = ### N
Axial Compressive Stress = Axial Force/Skirt area = 1.6613 N/mm2
Vessel
Vessel ID = 1219.0 mm
Vessel thk. = 15.00 mm
Insulation thk. = 50.0 mm
Vessel effective diameter ( Included 10% over diameter ), De = 1483.9 mm
Overall height, H = 3962.8 mm
Joint efficiency, E = 1.0 -
Material used for shell / skirt / base plate SA 516 Gr. 70 N / SA 36 -
Material tensile stress, St = 399.0 N/mm2
Material yield stress, Sy = 248.2 N/mm2
Empty Condition
Design temperature, Td = 38.0 C
o
Operating Condition
Design temperature, Td = 69.2 C
o
Testing Condition
Design temperature, Td = 233.0 oC
Material allowable stress, Sa = 114.5 N/mm2
Internal design pressure, Pi = 2.069 N/mm2
External design pressure, Pe = 0.0 N/mm2
Hydro-testing weight, Wt = 64665.0 N
COG measured from base, ht = 2278 mm
Shear stress at base, V = qs*De*H = 2204.2 N
Overturning moment at base, MT = 0.33*V*ht = 1656618.4 Nmm