Power OFF Delay Analog Timer AT8PSN/AT8PMN Series: Features

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

AT8PSN/AT8PMN Series Power OFF Delay Analog Timer

DIN W48×H48mm Solid-State, Power OFF Delay Timer (A)


Photoelectric

Features Sensors

● Time setting range (B)


Fiber
(AT8PSN: 0.05 to 10sec, AT8PMN: 0.05 to 10min) Optic
Sensors
● Simple time setup and direct read of time range
(C)
● Power supply Door/Area
Sensors
: 100-120VAC 50/60Hz, 200-240VAC 50/60Hz
100/110VDC, 24VAC 50/60Hz, 24VDC universal (D)
Proximity
● Application: Protect circuit when momentary power failure Sensors

and start it again


(E)
Pressure
Please read “Safety Considerations” in operation Sensors
manual before using.

Ordering Information (F)


Rotary
Encoders
AT 8 P SN (G)
Connectors/
No mark 200-240VAC 50/60Hz Connector Cables/
Sensor Distribution
Power supply 2 24VAC 50/60Hz, 24VDC Boxes/Sockets

6 100-120VAC 50/60Hz (H)


Temperature
7 100/110VDC Controllers

Time unit SN SEC


(I)
MN MIN SSRs / Power
Controllers
Time operation
P Power OFF Delay
Number of plug pins (J)
8 8-pin plug type Counters
Item
AT Analog Timer
※Sockets (PG-08, PS-08(N)) are sold separately. (K)
Timers

Specifications
(L)
Model AT8PSN- AT8PMN- Panel
Meters
Function Power OFF Delay
※1
Control time setting range 0.05 to 10 sec 0.05 to 10 min (M)
Tacho /
• 100-120VACᜠ 50/60Hz • 200-240VACᜠ 50/60Hz Speed / Pulse
Power supply Meters
• 100/110VDCᜡ • 24VACᜠ 50/60Hz, 24VDCᜡ universal
Allowable voltage range 90 to 110% of rated voltage (N)
Display
• Max. 1.5VA (100-120VACᜠ) • Max. 1.5VA (200-240VACᜠ) Units
Power consumption
• Max. 0.8W (100/110VDCᜡ) • Max. 0.2VA (24VDCᜡ), Max. 0.2W (24VDCᜡ)
Timing operation Power OFF start (O)
Sensor
Control Contact type Time limit DPDT (2c) Controllers

output Contact capacity 250VACᜠ 3A resistive load (P)


Switching
Relay Mechanical Min.10,000,000 operations Mode Power
Supplies
life cycle Electrical Min. 100,000 operations (250VAC 3A resistive load)
Repeat error Max. ±0.2% ±10ms (Q)
Stepper Motors
& Drivers
SET error Max. ±5% ±50ms & Controllers
Voltage error Max. ±0.5%
(R)
Temperature error Max. ±2% Graphic/
Logic
Insulation resistance Over 100MΩ (at 500VDC megger) Panels

Dielectric strength 2,000VAC 50/60Hz for 1 minute (S)


Field
Noise immunity ±2kV the square wave noise (pulse width: 1μs) by the noise simulator Network
Devices
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hours
Vibration
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min (T)
Software
Mechanical 300m/s² (approx. 30G) in each X, Y, Z direction 3 times
Shock
Malfunction 100m/s² (approx. 10G) in each X, Y, Z direction 3 times
Ambient temperature -10 to 55℃, storage: -25 to 65℃
Environment
Ambient humidity 35 to 85%RH
Approval ᜢᜧ
Accessory Bracket
Unit weight Approx. 100g
※1: Refer to time specifications for control time setting range.
※Environment resistance is rated at no freezing or condensation.

K-71
AT8PSN/AT8PMN Series
Connections 4 5

3 6
CONTACT OUT: CONTACT OUT:
250VAC 3A a b a b 250VAC 3A
RESISTIVE LOAD 2 7 RESISTIVE LOAD

1 8
(Time limit 1c) (Time limit 1c)

- + SOURCE:
• 100-120VAC 50/60Hz • 200-240VAC 50/60Hz
• 24VAC 50/60Hz, 24VDC • 100/110VDC

Dimensions (unit: mm)

● Bracket ● Panel cut-out


15 64.5
Min. 65
48 50

45 +0.6
0
Min. 65
44.8
56
45 +0.6
0

72
41

8-pin socket: PG-08 (sold separately)


Panel ※Refer to page G-19.

Unit Description ● Time specifications


Output
Power ON indicator reset Model Time range Time unit Time setting range
indicator 0.5 0 to 0.5 sec
Time range 1 0 to 1 sec
AT8PSN- SEC
display 5 0 to 5 sec
10 0 to 10 sec
0.5 0 to 0.5 min
1 0 to 1 min
AT8PMN- MIN
Time range 5 0 to 5 min
Time unit
selector (SEC, MIN) 10 0 to 10 min

Output Operation Mode


Contact a turns ON when the power applied and then turns off after setting time (T) is passed when the power off. There is
memory protection function. Even though changing setting time after cutting the power, time limit a contact turns OFF after
the setting time before cutting the power.
T

Power ②-⑦
⑧-⑥
Time limit a contact
①-③
⑧-⑤
Time limit b contact
①-④
Power LED operation

Up LED operation ※T: Setting time

K-72
Power OFF Delay Analog Timer
Proper Usage (A)
Photoelectric
Sensors
Power
The unit is power OFF delay timer, the time of min. (B)
power supply is 0.1sec for AT8PSN- type and 2sec for Fiber
Optic
AT8PMN- . Therefore be sure that the unit will operation Sensors

after power off. (C)


Please observe the allowable voltage range and apply or Door/Area
Sensors
cut the power at once to prevent from chattering.
(D)

Power ON Proximity
Sensors
OFF
(E)
Min. power Time Time stop Pressure
supply time operating Sensors

(F)

Power ON ON Rotary
Power Encoders
OFF OFF
(G)
Connectors/
※Please use the power within rating power and apply. Connector Cables/
Sensor Distribution
Boxes/Sockets
24VDC, 24VAC power supply should be insulated and
(H)
limited voltage/current or Class 2, SELV power supply Temperature
Controllers
device.
(I)
When supplying the power to the timer with 100- SSRs / Power
Controllers
120VAC or 200-240VAC, approx. 0.5A will flow for
0.5 sec (AT8PMN- ), or for 0.05 sec (AT8PSN- ).
(J)
When supplying the power to the timer with 24VDC, Counters

100/110VDC approx. 1.5A will flow for 0.5 sec


(AT8PMN- ), or for 0.05 sec (AT8PSN- ). Therefore be (K)
sure about the rating of contact and the power capacity. Timers

When performing dielectric voltage test or insulation (L)


Panel
resistance test while the unit is installed on control panel, Meters

Please isolate this unit from the circuit of control panel. (M)
Please make all terminals of this unit short-circuited. Tacho /
Speed / Pulse
Meters

Do not use this unit at below places.


(N)
Place where there is severe vibration or impact. Display
Units
Place where strong alkalis or acids is used.
Place where there is direct ray of the sun (O)
Place where strong magnetic field or electric noise is Sensor
Controllers
generated.
(P)
Switching
This unit may be used in the following environments. Mode Power
Supplies
Indoors
(Q)
Altitude: max. 2,000m Stepper Motors
Pollution degree 2 & Drivers
& Controllers
Installation category II
(R)
Graphic/
Logic
Panels

(S)
Field
Network
Devices

(T)
Software

K-73

You might also like