Product sheet

Securiterre -
Dual Mode Security

Overview

Designed to prevent static accumulation and discharge during road tanker


loading and off-loading, the Securiterre ensures correct bonding and
Features grounding procedures before product transfer.

It provides an effective connection The Securiterre continuously monitors the static earth path and carries out a
to earth and so prevents static unique “tanker verification” when connected. Only when these two conditions
accumulation are within correct parameters the system becomes permissive, thereby
eliminating the potential for operator error. Local indicator lights confirm the
Dual Mode monitoring tanker/earth condition to the operator, whilst the internal voltage free switch
(capacitance and resistance) contacts may be interlocked with tanker-loading systems, pumps, valves,
means the system cannot be alarms, etc. When not connected to the rest plug or rail tanker the circuit is
bypassed by clamping onto any grounded through a large resistance to reduce the hazard of sparking.

object other than the tanker


The Securiterre has proven indispensible wherever road tankers are involved
in the transfer of flammable products (liquids, gases or bulk powders, flakes
It constantly monitors the or granules). The Securiterre has been designed in accordance to ATEX
connection to the tanker and to regulations and is certified for use in hazardous areas.
earth, providing instant feedback
to the operator The Securiterre is versatile, easy in installation and operation and available
for prompt delivery. For applications involving the various conductive plant
It is self-diagnostic and will always (drums, IBC’s, vessels, rail tankers, etc.), alternative cabling solutions are
fail-safe in the event of a short or available.
open circuit
For additional safety the Securiterre has been equipped with a “rest position”
on which the clamp is mounted when not used. Via this point the Securiterre
calibrates itself, when not used, and optionally activates equipment, such as
a drive-off barrier or traffic lights, through an available relay contact.
Unique grounding Safety Procedure

State Action LED Activated Status Securiterre


I Clamp in rest position Yellow Rest position
II Clamp in hand Red Rest position
III Clamp on truck. R/C in range (or magnet). Wait 1 to 2 seconds. Yellow Release for Loading
IV Activate relay, grounding in progress / Check on relay resistance Green Release for Loading
Yellow Ground circuit check.
V Okay Green Authorise Loading
VI Clamp not on truck Red No proper ground

Installations

Securiterre
Basic grounding system
• Electronics in Ex-proof housing
• Bronze grounding clamp
• Coiled blue cable + cable gland, extends to 15 meters

Communication

The status information of the Securiterre can communicate to a Terminal Automation System (TAS) via an optional serial port in
ModBus RTU protocol. The status can so be used to analyse problems on the loading rack and to initiate appropriate remote
action.

Applications
• Petrochemical industries • Gas terminals
• Refineries • Aircraft refuelling systems
• Truck Loading terminals • Harbour Bunker facilities
• Rail Tanker terminals • Chemical industries
Technical specifications

Enclosure
Material: Aluminium, painted grey
Sealing: IP66 (NEMA 4x) weatherproof, fully O-ring sealed.
Mounting: Two lugs with 10 mm diameter holes.
Weight: 6 kg
Cable entries: 3x M20 x 1,5
Operating temperature
Temperature range -20 to +55 ºC
Power requirements
Mains supply 110 - 240 Vac +/-10%, 50/60 Hz
Power consumption: < 10 VA
Relay outputs
Rest position relay: one, SPDT, 250V/5A non-inductive load
Auxiliary relay: two, DPDT, 250V/5A non-inductive load
Indication
Signalling led’s red, yellow, green, good visibility to 45-degree angles
Brine magnet forces manual release

Communications isolated RS-485 port, Modbus RTU protocol (option)


RS-232
RS-422
Approvals
ATEX II 2 (1) / 1 G D
EEx d [ia] ia IIC T6, IP6x T+85°C or
EEx d [ia] ia IIC T6, IP6x T +85°C, c T6 / +85°C

Dimensions (mm)

147
127 125
Ø10 (4x)

Return point clamp


29

69
82

not connected
170
150

standby
192

grounded

Securiterre

# external earth connection M6

#
#

10 33.5 40 40 55
IS cable entry 1x 3 x cable entry M20 x 1.5
(for earth clamp connection)
Identification code
Pos 1 Application
U General purpose
Pos 2 Output
A With Signal Lights and 2 DPDT contacts
Pos 3 Application
T Truck (including brine magnet)
W Train wagon
Pos 4
* Not used
Pos 5, 6, 7 Instrument designation
6 4 0 Securiterre
Pos 8 Cable options
C Coiled cable max. extended length = 15 metres
Pos 9 Mains supply
A 110 - 240 Vac 50/60 Hz
Pos 10 Approval
A ATEX
Pos 11 Communication
M Modbus output via RS232/485/422
* Option not used

U A T * 6 4 0 C A A M Typical identification code

U A * 6 4 0 C A A Your identification code

Additional

Securistore
ATEX approved cable dispencer equipped with break-release and grounding clamp Part number : 1870871

7EæATæ%NRAFæAREæCOMMITTEDæTOæEXCELLENCEæ
%NRAFæ"6æ )NDIAæ%NRAFæ)NDIAæ0VTæ,TDæ
$ELFTECHPARKæ ææ8*ææ$ELFTæ "-$æ"USINESSæ#ENTRE æ#ITYæ#ENTRE æNDæFLOOR æ
0/æ"OXæ ææ!6æ$ELFT æ4HEæ.ETHERLANDSæ  4HIRUMALAIæ0ILLAIæ2OAD æ
4ELæ æ ææ æ&AXæ æ æææ 4.!'!2 æ#HENNAIçæ
æ
%MAILæINFO ENRAFNL æHTTPWWWENRAFCOMæ 4ELæ ææ æ&AXæ ææ
æ
æ
#HINAæ%NRAFæ"6æ3HANGHAIæ2EPæ/FFICE æ æ
2USSIAæ%NRAFæ"6æ-OSCOWæ2EPæ/FFICE
' æ)NTERNATIONALæ3HIPPINGææ&INANCEæ#ENTERæ  æ$OSTOEVSKOGOæSTREET
æ0UDONG!VENUE æ3HANGHAIææ ææ-OSCOW
4ELæ ææ æ&AXæ æææ æ
4ELææ&AXæ æææ æ4ELææ&AXæ æææ
æ æ
æ&RANCEæ%.2!&æ3ARLæ 3INGAPOREæ%NRAFææ0TEæ,TD
æ
æ:!#æLESæ"EAUDOTTES ææRUEæ0AULæ,ANGEVINæ æ3CIENCEæ0ARKæ$RIVE æçæ2UTHERFORD
æ
ææ3%62!.æ 3INGAPOREæ3CIENCEæ0ARKæ æ3INGAPOREæ
4ELæ æ ææææ æ&AXæ æ æææææ
æ 4ELæ æææ æ&AXæ æææ
æ
'ERMANYæ%NRAFæ'MB(æ 5NITEDæ+INGDOMæ%NRAFæ,TD
vW-US-4417.409-Rev.0

æ
/BEREæ$AMMSTRASSEæ ææ3OLINGENæ THæ&LOOR æ3COTTISHæ-UTUALæ(OUSE ææ.ORTHæ3TREET
æ0OSTFACHæ ææ3OLINGENæ (ORNCHURCH æ%SSEXææ2-ææ23
æ4ELæ æ ææ æ&AXææ æ æææ 4ELæ æ ææ æ&AXæ æ ææ
æ æ
)NDIAæ%NRAFæ)NDIAæ0VTæ,TDææ 53!æ%.2!&æ)NCæ
! æ3AGARæ4ECHæ0LAZA æ!NDHERIæçæ+URLAæ2OAD ææ æ7ESTæ3AMæ(OUSTONæ0ARKWAYæ.ORTH æ3UITEæ
3AKINAKA æ!NDHERIæ% æ-UMBAIæææ (OUSTON æ48æ
4ELæ ææ æ&AXæ æææ 4ELæ æææ æ&AXæ æææ
)NFORMATIONæINæTHISæPUBLICATIONæISæSUBJECTæTOæCHANGEæWITHOUTæNOTICEæ
šæ%NRAFæISæAæREGISTEREDæTRADEMARKæææææææ¥æ%NRAFæ"6æ4HEæ.ETHERLANDSæ

vW-IN-4417.408-Rev.0