COLUMNA A1

Section:
========
Rectangular: Width = 350 mm Depth = 300 mm

Gross section area, Ag = 105000 mm^2


Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 2512 mm^2 at rho = 2.39%
8 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1164.55 68.26 47.17 74.35 51.39 1.089

COLUMNA A2
Section:
========
Rectangular: Width = 350 mm Depth = 300 mm

Gross section area, Ag = 105000 mm^2


Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1011.22 16.35 33.25 38.82 78.98 2.375

COLUMNA A3

Section:
========
Rectangular: Width = 400 mm Depth = 300 mm

Gross section area, Ag = 120000 mm^2


Ix = 9e+008 mm^4 Iy = 1.6e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============
Bar selection: Minimum number of bars
Asmin = 0.01 * Ag = 1200 mm^2, Asmax = 0.08 * Ag = 9600 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 2512 mm^2 at rho = 2.09%
8 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1699.13 -40.66 76.96 -44.78 84.75 1.101

COLUMNA A4

COLUMNA A5

Section:
========
Rectangular: Width = 350 mm Depth = 300 mm

Gross section area, Ag = 105000 mm^2


Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm
Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1130.64 10.93 23.54 35.28 75.95 3.227

COLUMNA A6

Section:
========
Rectangular: Width = 350 mm Depth = 300 mm

Gross section area, Ag = 105000 mm^2


Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 726.88 -48.74 1.64 -94.08 3.17 1.930

COLUMNA B1

Section:
========
Rectangular: Width = 300 mm Depth = 350 mm

Gross section area, Ag = 105000 mm^2


Ix = 1.07188e+009 mm^4 Iy = 7.875e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 3768 mm^2 at rho = 3.59%
12 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1181.27 114.27 34.47 118.91 35.87 1.041
COLUMNA B2

Section:
========
Rectangular: Width = 300 mm Depth = 350 mm

Gross section area, Ag = 105000 mm^2


Ix = 1.07188e+009 mm^4 Iy = 7.875e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 2512 mm^2 at rho = 2.39%
8 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1495.20 -15.85 -56.95 -20.19 -72.53 1.274

COLUMNA B3
Section:
========
Rectangular: Width = 400 mm Depth = 450 mm

Gross section area, Ag = 180000 mm^2


Ix = 3.0375e+009 mm^4 Iy = 2.4e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1800 mm^2, Asmax = 0.08 * Ag = 14400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 2512 mm^2 at rho = 1.40%
8 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 2305.25 -67.87 28.51 -153.49 64.48 2.261

COLUMNA B4
Section:
========
Rectangular: Width = 400 mm Depth = 450 mm

Gross section area, Ag = 180000 mm^2


Ix = 3.0375e+009 mm^4 Iy = 2.4e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1800 mm^2, Asmax = 0.08 * Ag = 14400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 2512 mm^2 at rho = 1.40%
8 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 2687.92 87.29 65.32 96.46 72.18 1.105

COLUMNA B5

Section:
========
Rectangular: Width = 300 mm Depth = 400 mm

Gross section area, Ag = 120000 mm^2


Ix = 1.6e+009 mm^4 Iy = 9e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1200 mm^2, Asmax = 0.08 * Ag = 9600 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.05%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1727.56 11.41 -39.30 15.39 -53.00 1.349

COLUMNA B6

Section:
========
Rectangular: Width = 300 mm Depth = 350 mm

Gross section area, Ag = 105000 mm^2


Ix = 1.07188e+009 mm^4 Iy = 7.875e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1114.26 -63.45 28.17 -77.55 34.43 1.222

COLUMNA C1

Section:
========
Rectangular: Width = 300 mm Depth = 350 mm

Gross section area, Ag = 105000 mm^2


Ix = 1.07188e+009 mm^4 Iy = 7.875e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 934.84 35.14 35.65 58.92 59.78 1.677
COLUMNA C2

Section:
========
Rectangular: Width = 300 mm Depth = 350 mm

Gross section area, Ag = 105000 mm^2


Ix = 1.07188e+009 mm^4 Iy = 7.875e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1514.71 14.56 34.01 20.15 47.06 1.384

COLUMNA C3
Section:
========
Rectangular: Width = 300 mm Depth = 400 mm

Gross section area, Ag = 120000 mm^2


Ix = 1.6e+009 mm^4 Iy = 9e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1200 mm^2, Asmax = 0.08 * Ag = 9600 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.05%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1642.56 12.99 30.66 24.59 58.03 1.893

COLUMNA C4
Section:
========
Rectangular: Width = 300 mm Depth = 400 mm

Gross section area, Ag = 120000 mm^2


Ix = 1.6e+009 mm^4 Iy = 9e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1200 mm^2, Asmax = 0.08 * Ag = 9600 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.05%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1677.21 12.04 31.66 21.33 56.10 1.772

COLUMNA C5

Section:
========
Rectangular: Width = 300 mm Depth = 400 mm

Gross section area, Ag = 120000 mm^2


Ix = 1.6e+009 mm^4 Iy = 9e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============
Bar selection: Minimum number of bars
Asmin = 0.01 * Ag = 1200 mm^2, Asmax = 0.08 * Ag = 9600 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.05%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1723.92 8.37 27.21 16.38 53.27 1.958

COLUMNA C6

Section:
========
Rectangular: Width = 300 mm Depth = 350 mm

Gross section area, Ag = 105000 mm^2


Ix = 1.07188e+009 mm^4 Iy = 7.875e+008 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm
Factored Loads and Moments with Corresponding Capacities:
=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1037.87 -65.40 24.18 -84.08 31.09 1.286

COLUMNA D1

Section:
========
Rectangular: Width = 350 mm Depth = 300 mm

Gross section area, Ag = 105000 mm^2


Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 709.65 31.97 33.62 60.25 63.36 1.885

COLUMNA D2
Section:
========
Rectangular: Width = 350 mm Depth = 300 mm

Gross section area, Ag = 105000 mm^2


Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 5892 mm^2 at rho = 5.61%
12 #25 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1361.24 9.50 150.82 10.74 170.42 1.130

COLUMNA D3

Section:
========
Rectangular: Width = 350 mm Depth = 300 mm

Gross section area, Ag = 105000 mm^2


Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 833.43 12.79 29.23 37.48 85.63 2.930

COLUMNA D4

Section:
========
Rectangular: Width = 350 mm Depth = 300 mm

Gross section area, Ag = 105000 mm^2


Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2
Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.
phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 931.68 13.84 25.75 42.32 78.77 3.059

COLUMNA D5

Section:
========
Rectangular: Width =
350 mm Depth =
300 mm

Gross section area,


Ag = 105000 mm^2
Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============
Bar Set: User-defined
Size Diam (mm) Area (mm^2) Size Diam (mm) Area (mm^2) Size
Diam (mm) Area (mm^2)
---- --------- ----------- ---- --------- ----------- ----
--------- -----------
# 6 6 28 # 8 8 50 # 10
10 79
# 12 12 113 # 16 16 201 # 20
20 314
# 25 25 491

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm
Factored Loads and Moments with Corresponding Capacities:
=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 1099.99 9.39 23.45 32.12 80.19 3.420

COLUMNA D6

Section:
========
Rectangular: Width = 350 mm Depth = 300 mm

Gross section area, Ag = 105000 mm^2


Ix = 7.875e+008 mm^4 Iy = 1.07188e+009 mm^4
Xo = 0 mm Yo = 0 mm

Reinforcement:
==============

Bar selection: Minimum number of bars


Asmin = 0.01 * Ag = 1050 mm^2, Asmax = 0.08 * Ag = 8400 mm^2

Confinement: Tied; #6 ties with #8 bars, #8 with larger bars.


phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65

Layout: Rectangular
Pattern: All Sides Equal (Cover to longitudinal reinforcement)
Total steel area: As = 1256 mm^2 at rho = 1.20%
4 #20 Cover = 30 mm

Factored Loads and Moments with Corresponding Capacities:


=========================================================
Pu Mux Muy fMnx fMny fMn/Mu
No. kN kNm kNm kNm kNm
--- ----------- ----------- ----------- ----------- ----------- --------
1 608.75 -52.68 20.46 -83.78 32.53 1.590