Professional Documents
Culture Documents
Pa-830 Cam Bien Ap Khi PDF
Pa-830 Cam Bien Ap Khi PDF
PA-830
INTERNAL STRUCTURE
PA-830 (G 1/8)
5 3 4
※ VCR® is a registered trade name of Cajon Co. CAJON® is a registered trade name of Swagelok Co.
Note: For handling of VCR fittings, please contact a service center of Swagelok Co.
PA-830
PRESSURE TRANSDUCERS WITH AMP.
■ STANDARD SPECIFICATIONS
● Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 V DC.
PA-830
Item Model number
101G 501G 102G 352G 103G 102V 351A 102A
Pressure reference Gauge Absolute
Rated pressure range kPa {kgf/cm2} 9.8 49.0 98.1 343 981 − 98.1 34.3 (abs) 98.1 (abs)
{0.1} {0.5} {1} {3.5} {10} {−1} {0.35} {1}
Maximum pressure kPa {kgf/cm2} 19.6 98.1 196 686 1961 196 103 (abs) 196 (abs)
{0.2} {1} {2} {7} {20} {2} {1.05} {2}
Break-down pressure kPa {kgf/cm2} 29.4 147 294 1030 2942 294 147 (abs) 294 (abs)
{0.3} {1.5} {3} {10.5} {30} {3} {1.5} {3}
Operating temp. range °C − 20 ~ 70
General specifications
Supply voltage V DC 12 ~ 24 ± 10 %
Power
Consumption current mA 20
maximum
※ 1 PA-830-VCR : Also compatible with SUS316.
※ 2 An “O” ring is provided for only G1/8 type. (Positive pressure : P15, Negative/Absolute Pressure : P12.5)
PA-830
PRESSURE TRANSDUCERS WITH AMP.
PA-830
Item Model number
101G 501G 102G 352G 103G 102V 351A 102A
Output voltage V DC 1~5
■ ENVIRONMENTAL CHARACTERISTICS
Test item Test conditions (At 25 ± 5 °C) Permissible change
10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s , 2
Vibration
3 directions for 2 hours each
Shock 490 m/s2, 3 directions for 3 times each Zero voltage, Span voltage:
± 1 %F.S. maximum each
Pressure cycling 0 ~ Rated pressure, 106 cycles and ±3 %F.S. (101G) each
Power B
Pressure Sensor Output
Main circuit
Common
Shield
PA-830
PRESSURE TRANSDUCERS WITH AMP.
1/4 外形図
SN plate label Red Power B
22.5 AWG26 ULNo.2844 (φ 3.8)
White Output
22 12 8 Part No. label 4 – core shielded cable
L = 1500 ± 50 Green N.C.
Black Common
Shield Fitting
8
φ 30
Cable bush (ESS-1)
● R1/4 type
56 ± 1 (10)
SN plate label
22 23.5 AWG26 ULNo.2844(φ 3.8)
Part No. label 4 – core shielded cable
13.5 8 L = 1500 ± 50
8
(25.4)
φ 30
● VCR type
59 ± 1 (10)
(26.5)
(16) 8.5 SN plate label
19 AWG26 ULNo.2844 (φ 3.8)
Part No. label 4 – core shielded cable
L = 1500 50
8
φ 30
1/4 VCR
(SUS 316) Housing (Aluminum with alumite finish)