A B C D E F A B C D E F A B C D E F A B C D E F

B
10200 mm 10200 mm 10200 mm 10200 mm

2410 mm 1390 mm 3975 mm 1265


1160 mm
mm 2410 mm 1390 mm 3975 mm 1265
1160 mm
mm 2410 mm 1390 mm 3975 mm 1265
1160 mm
mm 2410 mm 1390 mm 3975 mm 1265
1160 mm
mm
900 900 3800 1500 3635
1CB7S1 2CB19S1

900

900
8

8
C-003 C-003
F-003 F-003

2CB18S1

2CB18S1
1CB9S1

1CB9S1
3000 mm

3000 mm

3000 mm

3000 mm
800
1200 1400 1400 CB CB

800
1CB3S1 1CB3S2 2CB1S1 2CB1S2

1200

1400

1400

1400
7

7
C-001 C-001 C-001 3CB1S1 3CB1S2
F-002
F-001 F-001
SLAB ON FILL DETAILS
0.20 GRAVEL FILL

3CB4S3

3CB5S3

3CB2S2
2CB9S1
1CB4S3

1CB2S3

2CB8S3

2CB3S4

2CB2S3
O.10 CONCRETE SLAB
4000 mm

4000 mm

4000 mm

4000 mm

CB
10 MM DIA. BAR SPACE@
0.40 O.C., B.W. A A

1200 1500 1400


1560
2CB13S1 2CB13S2 3CB3S1 3CB3S2
1200

1500

1400
6

6
C-001 C-001

1500
F-002
F-001 F-001
3075 mm

3075 mm

3075 mm

3075 mm
17500 mm

17500 mm

17500 mm

17500 mm
2CB24S1
1CB4S2

1CB2S2

2CB8S2

2CB3S3

2CB2S2

3CB4S2

3CB5S2

3CB2S1
2CB14S1

CB
1575
2CB25S1 2CB12S1 1385
5

5
1425 mm
1425 mm

1425 mm

1425 mm
1200 1400 2065

1425
STAIR

C-003 3CB7S1 3CB7S2


1200

1400

1400
4

4
2CB21S1

800
C-001 C-001 C-001
2CB23S1

2CB17S1
F-002

1CB2S1

2CB8S1

2CB3S2

2CB2S1
1CB4S1
F-004
CB

3CB5S1
3CB4S1
3000 mm

3000 mm

3000 mm

3000 mm
800

2CB15S1
1200 1400 1400

CB
C-002 1CB6S1 1CB6S2 2CB7S1 2CB7S2 3CB6S1
1200

1400

1400
3

3
2CB7S3

800
1425 mm

1425 mm

1425 mm

1425 mm
C-001 C-001

F-002

1CB1S1

2CB4S1
1CB4S1

2CB3S1
F-001 F-001
2CB5S1 CB 800
1400
2

2
1400

2CB11S1
1575 mm

1575 mm

1575 mm

1575 mm
1400

1400

C-002 C-002 1CB8S1


1

1
F-001 F-001 2CB16S1 2CB16S2
1265
2410 1390 3200 3200
2-12A

Footing Assignment Plan Tie Beam Layout Plan Second Floor Beam Layout Roof Framing Plan - roof beam line

400 mm
(EL. 0 mm) (EL. 1500 mm) (EL. 4700 mm) (EL. 7700 mm) 10@75 mm

(Scale 1:100) (Scale 1:100)


(Scale 1:100) (Scale 1:100)

2-12F
250 mm
1CB2:Section A

C
A

B
(Scale 1:15)
A

3000 mm 4500 mm 4000 mm 2-16C


3000 mm
1650 mm 2375 mm 2125 mm
1625 mm
1600 mm 2375 mm 2125 mm

400 mm
1625 mm
2-12A 2-16C 2-16C 2-16A 10@75 mm
2-16A 2-16A

10@75 mm 10@150 mm 10@75 mm 10@75 mm 10@150 mm 10@75 mm 10@75 mm 10@150 mm 10@75 mm


10@75 mm 10@150 mm 10@75 mm 2-12E
400 mm

250 mm
1CB2:Section B
2-12F+2-12E 2-12E 2-12F (Scale 1:15)
2-12F+2-12E
2-16C

1125 mm 475 mm 2650 mm 1600 mm


1100 mm 1100 mm 2-12F
250 mm 2350 mm 2400 mm

400 mm
1CB1:Section A
(Scale 1:15) 1CB2:Elevation 10@75 mm
1CB1:Elevation (Scale 1:25)
(Scale 1:25)
2-16A 2-12E
250 mm
1CB2:Section C
(Scale 1:15)

A
A

400 mm
3000 mm
10@75 mm

1625 mm
2025 mm 3325 mm
1625 mm
2025 mm 3325 mm 2-12F
2-16A 2-16A
250 mm
2-16A 2-16C 2-16A
1CB3:Section A
(Scale 1:15)

2-16A 10@75 mm 10@150 mm 10@75 mm

400 mm
10@75 mm 10@150 mm 10@75 mm 10@75 mm 10@75 mm

2-12F+2-12E

400 mm
2-12F+2-16E 2-12F

1100 mm 1100 mm 2-12F


1500 mm 475 mm 3600 mm 250 mm
1CB4:Section A
2800 mm (Scale 1:15)

250 mm
2-16F 1CB4:Elevation
1CB3:Section B (Scale 1:25)
3800 mm 6400 mm (Scale 1:15)

1CB3:Elevation
(Scale 1:25)
DESIGNED BY: REVISIONS: PROJECT TITLE: APPROVED BY: SHEET CONTENT:
DESIGNER: SET NO. SHEET NO.
DATE:
DRAFTED BY:
ROLLY MARC G. SOTELO DATE:
CIVIL ENGINEER
CHECKED BY:
STR
DATE:___________ CAGAYAN
DATE: PROJECT
EMAIL: engr.rollymarcsotelo23@gmail.com PRC NUMBER: DATE ISSUED: LOCATION:
CONTACT: 09452896910 PTR NUMBER: PLACED ISSUED: