FIRESTOP POLYESTER

FIRE RESISTANT ELASTOPLASTOMERIC Distilled polymer-bitumen


WATERPROOFING MEMBRANE, WITH HARMLESS FLAME RETARDANT
ADDITIVES, SELF-PROTECTED WITH SLATE GRANULES

Waterproofing membranes
GRANTS LEED CREDITS

CATEGORY CHARACTERISTICS ENVIRONRMENTAL METHOD OF USE

EP
S Reazione al
fuoco
Resistenza
all’incendio

SPECIAL WATERPROOF NON TORCH HOT AIR NAILING


REACTION FIRE ASBESTOS TAR CHLORINE RECYCLABLE DANGEROUS EXHAUSTED
ELASTOPLASTOMERIC AND FIRE ECO GREEN APPLICATION APPLICATION
TO FIRE RESISTANT FREE FREE FREE OIL FREE
FOR SPECIFIC USES RESISTANT WASTE

HOW TO PROTECT VISIBLE WATERPROOF COVERING LAYERS FROM FIRE


1 PROBLEM In many cases of fire, the roofing constitutes the building’s weak point as it is put under stress by the load,
the flames tend to rise upwards and the fire may be fuelled by the materials of the roof itself. In Italy, the
technology and legal regulations regarding protection against fire coming from the interior of a building
are highly developed. It must not be forgotten however, that many serious fires often start on the roof as a
result of sparks carried by the wind from a fire in a nearby building, or even from the torch used to install
roofing membranes. A heavy protection consisting of a layer of gravel or of a cement hood provides
sufficient fire protection. This also applies to pitched roofs, when they are finished with a membrane
with metallic self-protection. Not all structures however are suitable to support heavy protection and on
flat roofs and ribbed metal sheets, coats with metallic foil cannot be applied and they are not recom-
mended for use on insulating panels which have a high thermal resistance. To assess the behaviour of
the membranes in a fire, INDEX is the only company in Italy that has equipped itself with the Nord Test
ROOF Flat Sloped appliance, approved by Swedish Institute SP, Sveriges Provnings-och Forskningsinstitut, which is valid
Concrete Wood for all Scandinavian countries, including Denmark, where fire prevention regulations are particularly strict
SUBSTRATE because of the high number of wooden roofs in the country. The same test, bearing No.UNI ENV 1187/2,
Previuos membrane Thermal insulation
was selected also by CEN which, as designated by the EU, is delegated to setting up fire resistance tests.
F
2 SOLUTION combustible underlying surface and on incombustible
underlying surface.
INTENDED USE OF “CE”
MARKING SPECIFIED
This makes it suitable for laying on flat and pitched
roofs and also on combustible and incombustible un-
ACCORDING TO THE
derlying surfaces, provided that the density is ≥16 kg/ AISPEC-MBP GUIDLINES
m3, for which it can be used on any type of thermal EN 13707 - REINFORCED BITUMEN
insulation product with density of ≥16 kg/m3; on SHEETS FOR ROOF
wooden laying surfaces; on cement-based laying WATERPROOFING
FIRESTOP
surfaces; on metal laying surfaces; on bituminous • Upper layer in multi-layer systems without
laying surfaces etc. The product’s fire resistance is permanent heavy surface protection
FIRESTOP POLYESTER is a fire resistant membrane long lasting and is constantly controlled in the factory. - FIRESTOP POLYESTER
containing harmless inorganic anti-flame additives - it The reinforcement of FIRESTOP POLYESTER con-
is the result of INDEX’s research. It does not have any sists of a rot-proof, non-woven single strand polyester EN 13859-1 - UNDERLAY FOR
of the counter-indications typical of membranes self- fabric; the waterproofing mass which covers it resists DISCONTINOUS ROOFING
protected with a metallic foil. It can be applied without temperature ranges and ageing. The upper side, self- - FIRESTOP POLYESTER
any protection on both flat and pitched roofs, and on protected by hot-bonded and pressed slate granules,
insulating layers with high thermal resistance. is a further protection against fire.
FIRESTOP POLYESTER is a polymer bitumen wa- Over this, a side overlapping strip without any slate, protected with a strip of Flamina film (to be torch
terproofing membrane that has been tested pursuant melted) enables you to seal the joint.
to the Scandinavian standard concerning reactions
to external fire: Nord Test Method-Resistance to
ADVANTAGES This film also lines the membrane’s lower side, ensur-
ing it is laid fast and safe.
fire spread according to SS 02 48 24 - NT FIRE • The membrane is fire-resistant and can be
006, assimilated as European method UNI ENV
1187/2. Furthermore, it has been classified as Broof
installed also on insulation with a high thermal
resistance. APPLICATION FIELDS
(t2) pursuant to standards UNI EN 13501-5 on both • Contain non-toxic flame retardant additives. FIRESTOP POLYESTER protects the entire covering
system from fire when used as a final layer on roofs
CERTIFICATIONS with visible waterproofing coat also under photo-
voltaic systems.
It is particularly suitable for covering systems in
ribbed metal sheets and wood. Furthermore, it is
recommended for use on systems where insulating
panels which are sensitive to fire will be laid and as an
Certification “Warrington fire research” Certification “Warrington fire research”
Exceeds external fire resistance test according to ENV 1187/2 Exceeds reaction to fire test according to EN-ISO 11925-2 under-tile membrane on wooden structures.
and it is classified according to EN 13501-5: Broof-t2 and it is classified according to EN 13501-1: Euroclass E FIRESTOP POLYESTER can be used on either flat
or sloping roofs.

1st DIVISION
1st LINE
TECHNICAL CHARACTERISTICS
FIRESTOP
Standard
T POLYESTER
Reinforcement “Non-woven” Spunbond
polyester fabric
Weight EN 1849-1 ±15% 4.5 kg/m2
Roll size EN 1848-1 ≥ 1×10 m
Watertightness EN 1928 – B ≥ 60 kPa

Maximum tensile
force L/T EN 12311-1 –20% 750/600 N/50mm
Elongation L/T
EN 12311-1 –15% V.A. 50/50%
Resistance to tearing
(nail shank) L/T EN 12310-1 –30% 150/150 N
Dimensional
stability L/T EN 1107-1 ≤ –0.50/+0.50%
Flexibility to low
temperature EN 1109 ≤ –10°C
Flow resist. at high temp. EN 1110 ≥ 120°C
• after ageing EN 1296-1110 –10°C 120°C
Res. to water penetration EN 1928 W1
• after ageing EN 1296-1928 –
UV
ageing EN 1297 Test passed
Reaction to fire
Euroclass EN 13501-1 E
External fire

the numerous possible uses and the possible interference of conditions or


elements beyond our control, we assume no responsibility regarding the results
which are obtained. The purchasers, of their own accord and under their own
responsibility, must establish the suitability of the product for the envisaged use.
performance EN 13501-5 B roof (t2)
Compliant with EN 13707 in terms of the resistance factor to steam penetration for reinforced polymer-bitumen membranes, the value of µ =20 000 may be considered, unless declared otherwise.

REACTION TO FIRE TEST ACCORDING ENV 1187/2, OF FIRESTOP

Maximum index = 55 cm

Membrane with Membrane with


slate granules metal foil FIRESTOP
Equipment complying ENV 1187/2 Running test Comparison of the results

COMPOSITION OF THE MEMBRANE


FIRESTOP POLYESTER
Elastoplastomeric “Non-woven” Elastoplastomeric
polymer polyester polymer-bitumen added
bitumen added fabric with flame retardant

The advice and technical information provided, is what results from our best
and may be changed or updated by INDEX at any time without previous warning.
The figures shown are average indicative figures relevant to current production

knowledge regarding the properties and the use of the product. Considering
with flame retardant

Self-protection Selvedge Flamina


with slate granules

PRODUCT FINISHING

EMBOSSING FLAMINA. The embossing on the lower surfaces of the mem- MINERAL PROTECTION. On the visible face of the membrane, a protective
branes finished with Flamina film makes it possible to lay the product precisely coating made up of slate granules of various colours is hot bonded. This mineral
and quickly; forming a smooth surface when melted with the torch. It indicates shield protects the membrane from ageing caused by UV rays.
the correct melting temperature and lets the film retract faster. The embossing
also enables optimal vapour diffusion; in spot bonded and loose laid installation,
in the points where it remains intact, preventing blisters and swelling.

• FOR ANY FURTHER INFORMATION OR ADVICE ON PARTICULAR APPLICATIONS, CONTACT OUR TECHNICAL OFFICE • IN ORDER TO CORRECTLY USE OUR PRODUCTS, REFER TO INDEX TECHNICAL SPECIFICATIONS •
S.7 - 1.000 - 4/2012ing

Internet: www.indexspa.it
For technical and commercial information: tecom@indexspa.it
Accounting department: index@indexspa.it
Export department: index.export@indexspa.it

Via G. Rossini, 22 - 37060 Castel D’Azzano (VR) - Italy - C.P.67 - Tel. (+39)045.8546201 - Fax (+39)045.518390 “GBC Italia” Associated

© INDEX

You might also like