Upto Interchange Level: Shear Ties Design

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

STRUCTURE KDC (LHS) By: Abhinav Sheet no.

SHEAR WALL DESIGN SW1

Level upto Interchange Level


segment a length (m) 3.15 400
Concrete M 35
Steel Fe 500 D
thickness = 400 mm

Consider 1 m strip 1000


Out of Plane Moment MY 514.28 kNm
L/C 1003

Pu of entire segment = -373.41 Mton


3663.11 kN

Pu of 1m strip = 1162.9 kN

2
M/fckbD = (514.28*10^6) / (fck*1000*300^2)

= 0.1633

P/fckbD = (1162.9*10^3) / (fck*1000*300)

= 0.1108

d' = 40
d'/D = 40/300 = 0.13 (SP16 Chart 37)
p/fck = 0.04
p (req) = 1.4 %
As (req) = 4200
Provide 14 bars of dia 20 per meter strip
As (prov) = 4398.23 mm2
p (prov) = 1.47 %

Shear Ties Design


2
IN-Plane Shear Stress = 1.201 N/mm
Shear Strength τC
2
= 0.41 N/mm (based on 0.74 % steel)
VUS (req) = (1.201 - 0.41) * 3.15 * 0.35
= 87.21 Mton

Provide 2 L 10 Dia @ 200 mm c/c


VUS (provided) = 0.87*fy*Asv*d/sv
= 89.32 Mton OK

10-04-20

You might also like