P&ID BASIC COLUMN CONTROL SYSTEM

PC
PC
115
115
PV
115
Meanings of Identification Letters
First Letter Second or Third Letter
FT111 Feedforward LC FD Vent F Flow C Control
LT
117 117 L Level T Transmit
Feed Tank P Pressure or Vacuum V Valve, Damper, or Louver
T Temperature
FC Distillate
114 Receiver Location of Instrumentation
FC
118 Instrument Located on Panel in Control Room
FV FV
114 118 Instrument Located in Plant
FT
118
FT FC
114 Overheads Identification of Instrument Connections
PT Reflux
115 FO Capillary
Electrical
Pneumatic
FC Storage Control Valve
111
FV
FT111 Feedforward Tank
111
D-IV TEKNOLOGI KIMIA INDUSTRI
FT RTD
JURUSAN TEKNIK KIMIA
111
Feed Column TT TC
FC
116 116
POLITEKNIK NEGERI MALANG
PIPING AND INSTRUMENTATION DIAGRAM
BASIC COLUMN CONTROL SYSTEM
Disusun oleh:
LC
113
1. Indah Sukmawati
2. Nadua Bella Wardani
FC
FC 112
Dosen Pembimbing:
LT
110
FV 113 Ernia Novika, S. T, M. T
110

FT
110
FC Steam

FV
112
FT
Bottoms 112
FC