Professional Documents
Culture Documents
Alloy Chart PDF
Alloy Chart PDF
Alloy Chart PDF
SPECIFICATION CHEMICAL CDA BRITISH DIN YIELD TENSILE ELONGATION BRINELL MODULUS ELECTRICAL ELECTRICAL CHARACTERISTICS
COMPOSITION STANDARD STANDARD STANDARD STRENGTH STRENGTH % 2" HARDNESS OF ELASTICITY CONDUCTIVITY CONDUCTIVITY
EQUIVALENT EQUIVALENT EQUIVALENT PSI x 103 (MIN) PSI x 103 (MIN) (MIN) PSI x 106 % IACS m/mm2h
BC-CU-110 CU – 99.9% 811 B5 1400 17655 5.1 – 6.0 27 – 30 28 – 35 10MM/500KG 17.6 97 MIN 56 MIN Pure electrolytic copper, excellent electrical and thermal conductivity.
HCC1 GK-CUL50 40 – 46 Alloy can be hard and soft soldered, limited weldability.
BC-CU-100 CU – 99.9% 811 B5 1400 17655 3.5 – 5.1 26 – 29 44 – 48 10MM/500KG 17.6 93 MIN 52 MIN Pure electrolytic copper with oxygen contents, excellent electrical and
HCC1 GK-SCUL50 33 – 38 thermal conductivity. Material can be processed in hydrogen atmosphere.
BC-CU-210 CU-CR 815 B5 1400 17655 39.5 – 44 54 – 59 20 – 25 10MM/500KG 17.5 77 MIN 44.5 MIN Heat treated chromium copper with excellent strength and conductivity.
CC1-TF GK-CUCRF35 100 – 140 Good hard and soft solderability.
BC-CU-300 CU-NI-SI SIMILAR B5 1400 SIMILAR 50 – 55 63 – 66 8 – 15 10MM/3000KG 17.5 35 – 44 22.6 – 25.5 Heat treated copper alloy with good thermal and electrical conductivity.
821 17666 135-160 MIN Alloy is resistant to stress corrosion.
CUN1251
BC-CU-310 CU-NI-SI SIMILAR B5 1400 SIMILAR 74 – 79 77 – 83 3–4 10MM/3000KG 17.3 26 – 35 15.6 – 20.2 Heat treated copper alloy (Same as BC-CU-300), but has higher mechanical
822 17666 190 – 205 properties, and lower conductivity readings. Alloy is resistant to stress
CUN1351 corrosion.