Professional Documents
Culture Documents
Certificate / Certificat Zertifikat /: ROS 1306005 C001
Certificate / Certificat Zertifikat /: ROS 1306005 C001
Certificate / Certificat Zertifikat /: ROS 1306005 C001
Zertifikat /
ROS 1306005 C001
exida hereby confirms that the:
Rosemount 5300
λSD λSU λDD λDU SFF
Route 1H
Standard ambient range 0 60 960 96 91.4%
Extended cold ambient
0 60 960 104 90.7%
range (option BR5, BR6)
Rosemount 5300
λSD λSU λDD λDU
Route 2H
Standard ambient range 0 60 960 96
Extended cold ambient
0 60 960 104
range (option BR5, BR6)
* FIT = 1 failure / 109 hours
SIL Verification:
The Safety Integrity Level (SIL) of an entire Safety Instrumented Function (SIF)
must be verified via a calculation of PFDavg considering redundant architectures,
proof test interval, proof test effectiveness, any automatic diagnostics, average
repair time and the specific failure rates of all products included in the SIF. Each
element must be checked to assure compliance with minimum hardware fault
tolerance (HFT) requirements.
Extended operating ambient temperature range options (down to -60C) must be
specified by the model code BR5 or BR6 along with option code QT for this
certificate to remain valid below -40C.
80 N Main St The following documents are a mandatory part of certification:
Sellersville, PA 18960
Assessment Report: ROS 13-06-005 R002 V2 R1 or later
Safety Manual: #00809-0100-4530
T-002, V5R3
Page 2 of 2