Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

Vipros 357 Queen with Fanuc 18P Control


Layout Drawings

Amada America Inc.


7025 Firestone Blvd.
Buena Park CA. 90621
Phone: (714) 739 2111
Fax: (714) 739 4099
Email info@amada.com
Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 1 of 10
Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

Warning
• Qualified personnel must complete all work.

• Do not apply power to the Vipros 357 Queen until an A.E.S.I. (Amada Engineering
and Service Incorporated) Engineer is present and has instructed you to do so.

• Not all information required for proper installation, of the Vipros 357 Queen is
included with this document. Specific details for proper installation are found in
the document Vipros 357 Queen with Fanuc 18P User Pre-installation Guide
available at the Amada America Internet web site at http://www.amada.com.

• Considerable effort has been made to ensure that this manual is free of
inaccuracies and omissions. However, as we are constantly improving our
product, some of the data contained herein may be out of date. Please check our
Internet site, http://www.amada.com, for the latest release of this document.

Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 2 of 10
Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

Table Of Contents
Planning the Location of the Machine ..............................................................................................................................................4
Plan View – Vipros 357 Queen ........................................................................................................................................................5
Plan View – Vipros 357 Queen with V357hs Conveyor....................................................................................................................6
Plan View – Vipros 357 Queen with V357hs Conveyor and MP1225 Loader ..................................................................................7
End View - Vipros 357 Queen ..........................................................................................................................................................8
Elevation View –Vipros 357 Queen..................................................................................................................................................9
SBC EX 5.5Chiller Placement ........................................................................................................................................................10

Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 3 of 10
Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

Planning the Location of the Machine


The following diagrams provide the details for positioning your new machine.
! Not all information required for proper installation, of the Vipros 357 Queen is included with this document. Specific details
for proper installation are found in the document Vipros 357 Queen with Fanuc 18P User Pre-installation Guide available at
the Amada America Internet web site at http://www.amada.com.
! No obstacles are allowed in the worksheet travel area and the ceiling must be at least 40" above the top of the Vipros 357
Queen.
! All of the Recommended Safety / Maintenance areas should be used, but you must at least ensure that the doors of the
Fanuc 18P control unit can be opened. Any reduction of the Recommended Safety / Maintenance areas may increase the
possibility of personnel injury and increase the time and cost of installation or maintenance.
! The Vipros 357 Queen and Fanuc 18P control must be protected from direct sunlight or other heat sources. Exposure to
direct heating sources such as infrared heaters have been shown to affect punch and die alignment.
! The positioning of the SBC EX 5.5 Chiller is very flexible.

Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 4 of 10
Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

Plan View – Vipros 357 Queen


Electrical Requirements
E1 Vipros 357 Queen
230 / 460 / 3 / 60 ±10% 30 kVA
76 amps @ 230 / 3 / 60 VAC 30" E1
38 amps @ 460 / 3 / 60 VAC
Fanuc 18P Control
E2 SBC EX5.5 Chiller

28"
230 or 460 / 3 / 60 ±10% 15 kVA 57" 55"

59.37" Maximum
37 amps @ 230 / 3 / 60 VAC Hydraulic Unit
SBC 5.5 Chiller
19 amps @ 460 / 3 / 60 VAC

26"
59"
Compressed Air Requirements

37"
E2
P1 Vipros 357 Queen 80 psi @ 8.8 ft³/min.

323.4" Recommended Safety / Maintenance Area 40" from all components

14"
10"

VIPROS 357 QUEEN

50" Working Range


Optional Material
100" Maximum Travel Area 50" Material
183.8" Machine Length

Supports Required

Optional Material
Supports Required

P1

Centerline
Machine

72.0" to Load Position


74.41" to Edge of Table

148.82" Machine Width 12" 12" 12"


288.0" Maximum Material Travel Area 144" Material Scale
368" Recomended Safety / Maintenance Area 40" from all components

Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 5 of 10
Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

Plan View – Vipros 357 Queen with V357hs Conveyor


Electrical Requirements
E1 Vipros 357 Queen
230 / 460 / 3 / 60 ±10% 30 kVA
76 amps @ 230 / 3 / 60 VAC 30" E1
38 amps @ 460 / 3 / 60 VAC
Fanuc 18P Control
E2 SBC EX5.5 Chiller

28"
230 or 460 / 3 / 60 ±10% 15 kVA 57" 55"

59.37" Maximum
37 amps @ 230 / 3 / 60 VAC Hydraulic Unit
SBC 5.5 Chiller
19 amps @ 460 / 3 / 60 VAC

26"
59"
E3 V357hs Conveyor

37"
208 - 230 / 460 / 3 / 60 ±10% .8 kVA E2
2.1 amps @ 208 / 3 / 60 VAC

14"
10"
2.0 amps @ 230 / 3 / 60 VAC
1.0 amps @ 460 / 3 / 60 VAC
Compressed Air Requirements
P1 Vipros 357 Queen 80 psi @ 8.8 ft³/min.
389" Recommended Safety / Maintenance Area 40" from all components

VIPROS 357 QUEEN

50" Working Range


Optional Material
100" Maximum Travel Area 50" Material
183.8" Machine Length

Supports Required

Optional Material
Supports Required

P1

Centerline
Machine

V357hs Conveyor

66"
E3

39"

Access Required
this area for
scrap removal

72.0" to Load Position


74.41" to Edge of Table

148.82" Machine Width 12" 12" 12"


288.0" Maximum Material Travel Area 144" Material Scale
368" Recomended Safety / Maintenance Area 40" from all components

Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 6 of 10
Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

Plan View – Vipros 357 Queen with V357hs Conveyor and MP1225 Loader
Electrical Requirements
E1 Vipros 357 Queen
230 / 460 / 3 / 60 ±10% 30 kVA
76 amps @ 230 / 3 / 60 VAC 30" E1
38 amps @ 460 / 3 / 60 VAC
Fanuc 18P Control
E2 SBC EX5.5 Chiller

28"
230 or 460 / 3 / 60 ±10% 15 kVA 57" 55"

59.37" Maximum
37 amps @ 230 / 3 / 60 VAC Hydraulic Unit
SBC 5.5 Chiller
19 amps @ 460 / 3 / 60 VAC

26"
59" MP1225
E3 V357hs Conveyor E4

37"
Xformer
208 - 230 / 460 / 3 / 60 ±10% .8 kVA E2
2.1 amps @ 208 / 3 / 60 VAC

14"
10"
2.0 amps @ 230 / 3 / 60 VAC
1.0 amps @ 460 / 3 / 60 VAC P2
E4 MP1225 Loader
200 / 3 / 60 ±10%, 10 Kva

65.95"
To operate at 230 / 460 VAC a step up
389" Recommended Safety / Maintenance Area 40" from all components
transformer with the following service is
required VIPROS 357 QUEEN
29 amps @ 200 / 3 / 60 VAC
26 amps @ 230 / 3 / 60 VAC
13 amps @ 460 / 3 / 60 VAC
50" Working Range
Compressed Air Requirements Optional Material
100" Maximum Travel Area 50" Material
183.8" Machine Length

188.06" MP1225 Length


Supports Required
P1 Vipros 357 Queen 80 psi @ 8.8 ft³/min.

P2 MP1225 Loader 75 psi @ 31.8 ft³/min.

Optional Material
Supports Required

P1
MP1225 Loader

Forklift Access

Centerline
Required This Area

Machine
For Material / Parts
Loading / Unloading

V357hs Conveyor

66"
E3

39"

Access Required
this area for
scrap removal

72.0" to Load Position


74.41" to Edge of Table
75.41" to Edge of MP1225 12" 12" 12"
141.74" MP1225 Loader Width
217.15" Scale
148.82" Machine Width
288.0" Maximum Material Travel Area 144" Material
441" Recommended Safety / Maintenance Area 40" from all components

Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 7 of 10
Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

End View - Vipros 357 Queen


22.8"

12" 12" 12"

Scale

7.9"

19.7"
3.9"
29.5"
35.4"
98.7"
110.6"
Shipping Width w/o Crate
148.8"

Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 8 of 10
Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

Elevation View –Vipros 357 Queen


Center of Track 200
52.2"
Y-axis 0" Reference
Throat Depth
1.8"
56.9" 15.9" 50.0" 25.8" 19.7"
10.0"
12" 12" 12"

Scale

QUEEN
28"
Fanuc
Control
Hydraulic
90.9" Unit
Material Pass Line
63.0"
52.0"
37.7"*
8.7"
7.9"

3.9" 33.5" 32.9" 9.8" 29.1" 13.8" 33.5" 14" 26"


6.5" 9.9"
11.0"
103.1"
184" 59.37" Maximum

*Material Pass Line will vary with installed options

Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 9 of 10
Vipros 357 Queen with Fanuc 18P Control Layout Drawings ©Amada America, Inc.

SBC EX 5.5Chiller Placement


The SBC EX 5.5 Chiller is very important to the reliable operation of the Vipros 357 Queen.
The SBC EX 5.5 Chiller must be placed so that an adequate flow of air is maintained.
The position of the SBC EX 5.5 Chiller is flexible. The SBC EX 5.5 Chiller is supplied with two (2) fifteen-foot lengths of hose to
connect the to the Vipros 357 Queen Hydraulic Unit. The customer may supply a longer length of hose if required.
Under normal operating conditions the SBC EX 5.5 Chiller may be placed against walls as shown. However, for maintenance
purposes access to all sides of the SBC EX 5.5 Chiller may be required.
The SBC EX 5.5 Chiller must have a minimum 60" of clearance above the SBC EX 5.5 Chiller for proper airflow.
Under normal operation the chiller may be placed against walls as shown.
For maintenance access to all sides may be required.
Chiller Location is shown for reference only.

Maximum Material
Travel Area X144" by Y50"

6"

Hydraulic Unit

Fanuc 18P Control

2 supplied 15ft. water hoses


6"

Air Flow

Print Date 01/25/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 10 of 10