NC4 is pure component ? As per markup is pseduocomponent in HMB
Pipe segement 6-P-110-5809-1 and 6-P-110-5809-2 flash calculation fails. Please check Please check the pressure profile across the Heat exchangers should be as per HMB Heat exchanger and pipe should have heat loss Min. flow scale factor -0.001 for heat exchangers Design flow rate for case -1 SOR and case-2 EOR + 21% overdesign as per heat exchanger datasheets Please check the Signal processing for the indicators shell and tube side MOC specification such as thermal cond., wall Cp and wall density source not mention. Vapor flow shell side should be match as per HMB. 110-PSV-5802-A/B valve type, Kd and back pressure co-effiecent are defualt. Strip chart needs to be configure for the heat exchangers and PSV With step size 0.1 and model speed is near ~1 In model notes not mention about assumption or data reference for the equipemnts like HE, PSV and pipe Flow indicators for the strip chart are missing for the shell and tube side flow Tube rupture orfice area is 692.37 mm sq as per model, but one tube area is 346.36 mm sq. what is source of two tube area considered for the tube rupture orifice. All applicable comments use for the other heat exchangers models.