Cat Electronic Technician 2016A v1.

0
Configuration

9/7/2020 9:01 AM

G3516A3 (WPS00169)
Parameter Value
Equipment ID abcdefghijklmnopq
Engine Serial Number WPS00169
ECM Serial Number 31376302AL
Software Group Part Number 2858513-00
Software Group Release Date MAR 2006
Software Group Description G3516A3 V 1.9 PROD

Genset Control #1
Parameter Value
Module ID $58
Application ID $60
Data Link ID $10

Description Value TT
ECM Identification Parameters
Equipment ID abcdefghijklmnopq 0
Engine Serial Number WPS00169 1
Timing Control
First Desired Timing 25.0 Deg
Second Desired Timing 27.0 Deg 1
Speed Control
Low Idle Speed 800 rpm 0
Minimum Engine High Idle 900.0 rpm
Speed
Maximum Engine High Idle 1220.0 rpm
Speed
Engine Acceleration Rate 50 rpm/s 4
Rated Engine Speed 1200 rpm
Desired Speed Input 0-5 VDC Input 0
Configuration
Engine Overspeed Setpoint Unavailable
Governor Type Setting Isochronous
Engine Speed Droop 0.0 % 0
Governor Gain Factor 2
Governor Stability Factor 1
Governor Compensation Factor 0
Auxiliary Proportional Governor 0 0
Gain 1
Auxiliary Integral Governor 0 0
Gain 1
Auxiliary Derivative Governor 0 0
Gain 1
Max Ratings Available 2
Speed Timing Map 0 0
Engine Load Timing Maps 3
Available
Engine Load Timing Map 0
Start/Stop Control
Driven Equipment Delay Time 120.0 sec 0
Crank Terminate RPM 250 rpm 0
Engine Purge Cycle Time 0 sec 0
Cooldown Duration 0 min 0
Cycle Crank Time 15 sec
Engine Overcrank Time 90 sec 1
Engine Speed Drop Time 15.0 sec 0
Engine Pre-Lube Time Out 480.000 sec 0
Period
Engine Load Calibration
Full Load Intake Manifold 34.8 psi 0
Pressure Configuration
No Load Intake Manifold 3.6 psi 0
Pressure Configuration
Monitoring and Protection
High Inlet Air Temperature 50 %
Engine Load Set Point
Passwords
Customer Password #1 ********
Customer Password #2 ********
Security Access Parameters
Total Tattletale 27
Configuration Group 1
description text 0 0
Prelube Status 0 0
Output Pwr Config Unavailable
kW driven Equipmt 0 hp 0