Preface
Thank you for use the product. Before you start to use this product, please be sure you have read the content
in the Preface and follow these guidelines.

Notice
Make sure the electric plugs and wires are all properly connected, and use the 3-cell electric wire only. If
an extension-board is used, the outlet of the extension-board is also 3-cell. Make sure the earth wire is
properly connected to the earth in order to prevent the leakage of electricity.
Don’t touch the electric plug with wet hand, in case of electric shock.
Don’t lean your body on the scale to avoid damaging the load cell.
Don’t impact the scale or shock the scale with heavy goods, in case of damaging the load cell. When
weighing, don’t exceed the maximum weighing range
Don’t get the product rained or washed by water; If there is some water on the product by inadvertence,
please wipe it clean with a dry cloth; If the scale doesn’t work normally, please send the scale to our
distributor as soon as possible. We shall do our best to service you.
Don’t put the scale in the places which are ultimately cold, hot or wet. These working conditions may
make the product not work normally or damage the product.
Don’t use organic chemistry solutions to wipe the surface and the panel of the product.
Don’t try to take the scale apart and repair the scale by non-professonal staff.
Don’t put your hands into the product through the place where the printer spins out. It may cause electric
shock with 110V/220V electricity.
Cut the connection between the scale and AC electricity when taking the scale apart under the guidance
of professional staff from our company.
Don’t try to disassembly the switch power inside of the scale. Because it takes a long time to discharge
the high voltage capacitance, and it’s very dangerous to disassembly the switch power when the high
voltage capacitance is not fully discharged.
Strongly recommend users to use thermal paper sold by our company. The scale can have a longer
life if working with thermal paper sold by our company because we have done a lot of experiments
and optimizations on the our thermal paper. On contrary, the life span of the printer may get
shortened if the printer works with the thermal paper, which is likely to deposit or leave carbon
deposits.
Thermal header is a precise instrument. Don’t touch it with fingers or sharp goods. Always use the
accessary cleaning tools to keep the header clean.

i
Guide to Read
Please go to page 7 Thermal Printer and learn the method to install paper and notices for users.
Please read page 2 General Functions, Configuration and Using Index carefully first in order to know
about the performance of the scale.
Please read page 16 Fast Prog carefully first , and learn frequently used programme operations of the
scale.
For ordinary users, please first read page 21, the two chapters Transfer and Lock of PLU (page 21) and
Manual Goods Sale (page 22) in the Sale Operations, and learn general sale operations of the scale.
For ordinary users, read page 63 Account Operations, get to know how to print the report forms and
delete the records. And read Operations of Sale Buffers in page 31 to learn how to look over the recent
sale records.
For advanced users, read the rest of Sale Operations,and learn auto mode and other functions.
For professional users, such as managers in big supermarket, should continue reading the rest of the
instruction.
When error warning shows up, check Reference Table For Errors and Its Instructions in page 70 .

Abbreviations and Glossary


PLU: Price of LookUp. It’s a cell which contains the information of goods
Weight PLU, Count PLU: By-weight PLU, By-Count PLU.
Dept., Class: Dept. is short for department, is the largest category in sales statistics. Class is the second
largest category in sales statistics.
U.Price, T.Price: Unit Price and Total Price.
Single T.Price, Sum T.Price: Single T. Price means the price of certain goods, while Sum T. Price means
the price of total trade.
Prog, F-Prog: Name of keys, Short for programme and Fast Programme.
T-Sale: Temporarily Sale. Trade goods is not an exist PLU. Sell them by input a manual price. And the
scale will think the goods as PLU 1 (Weight), or 2 (Count).
Spec: Specification. It is made up of many number parameters, which determines the operation flow and
working state.
TMSet: Working parameters setting.
DTSet: Working date setting.
Amount: The quantity of the goods, weight or count. It means weight (kg, lb) for weight PLU and count
(pcs) for count PLU
【Text】: Mark the Text as a key name.
〖Text〗: Mark the Text as a display indication name.

ii
Menu
Preface ........................................................................................................................... i

Notice .......................................................................................................................... i

Guide to Read .............................................................................................................ii

Abbreviations and Glossary .......................................................................................ii

Menu ............................................................................................................................iii

Examples Menu ........................................................................................................viii

1 Components of Barcode Print Scale ................................................................... 1

1.1 Check Accessories................................................................................................ 1

1.2 Keyboard .............................................................................................................. 1


1.2.1 The Original Overlay of the Keyboard ..................................................................................................... 1
1.2.2 Instructions for Keys................................................................................................................................. 2
1.2.3 Instruments for Keys in Function Area..................................................................................................... 2
1.2.4 Character Input Instructions...................................................................................................................... 3

1.3 Display Panel........................................................................................................ 5


1.3.1 Sketch Map of Display Panel.................................................................................................................... 5
1.3.2 Indication Signs ........................................................................................................................................ 5
1.3.3 Expression of Characters .......................................................................................................................... 6
1.3.4 Dot Matrix Display ................................................................................................................................... 7

1.4 Specifications ....................................................................................................... 7

1.5 Thermal Printer (bar code label printing scale only) ........................................... 7
1.5.1 Install Gap Paper....................................................................................................................................... 7
1.5.2 Gap Paper Mounts Recycle ...................................................................................................................... 9
1.5.3 Install Plain Paper ..................................................................................................................................... 9
1.5.4 Operations Concerning Paper ................................................................................................................... 9
1.5.5 Abnormity of Gap Paper Print .................................................................................................................. 9
1.5.6 Specification for printing interface ..................................................................................................... 10

2 General Functions, Configuration and Using Index ....................................... 11

iii
2.1 General functions ............................................................................................... 11

2.2 Setting of Print Format ....................................................................................... 11

2.3 Barcode printing and scanning........................................................................... 12

2.4 Measure Functions ............................................................................................. 12

2.5 Sale Functions .................................................................................................... 13

2.6 Salesman Function ............................................................................................. 14

2.7 Report Functions ................................................................................................ 14

2.8 Sales details ........................................................................................................ 14

2.9 Network function................................................................................................ 14

2.10 Ethernet Thermal Printer .................................................................................. 15

2.11 Software use ..................................................................................................... 15

3 Fast Prog.............................................................................................................. 16

3.1 Fast-Prog of PLU................................................................................................ 16

3.2 Fast-Prog of Shortcut Key for PLU.................................................................... 18

3.3 Fast-Prog of Spec Parameters ............................................................................ 19

3.4 Fast-Prog of Unit price ....................................................................................... 20

4 Sale Operations ................................................................................................... 21

4.1 Transfer and Lock of PLU.................................................................................. 21


4.1.1 Transfer by Using PLU Number............................................................................................................. 21
4.1.2 Tranfer by Using PLU Shortcut Keys..................................................................................................... 21
4.1.3 Transfer Temporary Weight PLU............................................................................................................ 22
4.1.4 Transfer Temporary Count PLU ............................................................................................................. 22

4.2 Manual Goods Sale ............................................................................................ 22


4.2.1 Sale and Print of Single Weight Goods................................................................................................... 22
4.2.2 Sale and Print of Single Count Goods .................................................................................................... 23

iv
4.2.3 No Weigh Sale for Weight Goods........................................................................................................... 23
4.2.4 Sale and Print for Different Kinds of Goods (No Cashing Mode).......................................................... 24
4.2.5 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment) ...................................... 24
4.2.6 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price) ........................ 25

4.3 Discount Operations ........................................................................................... 25


4.3.1 U.Price Discount..................................................................................................................................... 25
4.3.2 T.Price Discount...................................................................................................................................... 26
4.3.3 ±% price.................................................................................................................................................. 26
4.3.4 Auto Discount ......................................................................................................................................... 27
4.3.5 Unit Conversion of Temporary U.Price .................................................................................................. 27

4.4 Setting and Lock of Tare .................................................................................... 28


4.4.1 Weight Tare............................................................................................................................................. 28
4.4.2 Number Tare ........................................................................................................................................... 28
4.4.3 Lock and Unlock of Tare ........................................................................................................................ 28

4.5 Special sale mode ............................................................................................... 29


4.5.1 Enter and Exit of Special sale Mode....................................................................................................... 29
4.5.2 Sale under batch print mode ................................................................................................................... 29
4.5.3 Sale under prepack mode (only for weight PLU) ................................................................................... 30
4.5.4 Sale under Lock PLU mode.................................................................................................................... 30
4.5.5 Auto print mode (only for weight PLU) ................................................................................................. 31

4.6 Operations of Sale Buffers ................................................................................. 31


4.6.1 Switch of Sale Buffers ............................................................................................................................ 31
4.6.2 Cancel Sale Data in Sale Buffers ............................................................................................................ 31

4.7 Salesman and Waiter .......................................................................................... 32


4.7.1 Personnel Information ............................................................................................................................ 32
4.7.2 Salesman Function.................................................................................................................................. 32
4.7.3 Waiter Function....................................................................................................................................... 33

4.8 Inquiry of Sale Records and Markers of Returns of Goods............................... 33

4.9 Manual Weight ................................................................................................... 34


4.9.1 Manual Sale of Manual Weight Entry..................................................................................................... 34

4.10 Bar code printing and scanning........................................................................ 34


4.10.1 Exterior bar code................................................................................................................................... 34
v
4.10.2 Interior bar code.................................................................................................................................... 34

5 Programme Operations...................................................................................... 35

5.1 Please Read this Part First .................................................................................. 35

5.2 Basic Operations in Programme Interface ......................................................... 35


5.2.1 Tree-shaped Design of Edit Steps ........................................................................................................... 35
5.2.2 Frequently-used Keys in Prog Interfaces................................................................................................ 36
5.2.3 List of Programme Interface ................................................................................................................... 37

5.3 The Edit of All Parts in TMSet........................................................................... 43


5.3.1 Time Programme .................................................................................................................................... 43
5.3.2 Programme of Spec Parameters.............................................................................................................. 43
5.3.3 Programme of Text Parameters............................................................................................................... 44
5.3.4 Programme of PLU Shortcut Keys ......................................................................................................... 44
5.3.5 Programme of Fuction Shortcut Keys .................................................................................................... 45

5.4 The Edit of All Parts in DTSet ........................................................................... 45


5.4.1 Department Programme.......................................................................................................................... 45
5.4.2 Class Programme .................................................................................................................................... 46
5.4.3 PLU Programme ..................................................................................................................................... 46
5.4.4 Unit Programme...................................................................................................................................... 48
5.4.5 Barcode Programme ............................................................................................................................... 49
5.4.6 Print Formats Programme....................................................................................................................... 52
5.4.7 Salesman Programme ............................................................................................................................. 55

5.5 Assistant Data Programme ................................................................................. 56


5.5.1 Steps Select of PLU Programme ............................................................................................................ 56
5.5.2 Steps Select of PLU Fast Programme..................................................................................................... 56
5.5.3 Delete Sale Data ..................................................................................................................................... 57

5.6 Communication and Data Update ...................................................................... 58


5.6.1 Operations of files in USB flash Disk. ................................................................................................... 58
5.6.2 Ethernet Monitor Interface...................................................................................................................... 59
5.6.3 RS232 Communications ......................................................................................................................... 60

5.7 Hardware Assistant............................................................................................. 60


5.7.1 Validate Code.......................................................................................................................................... 60
5.7.2 Password................................................................................................................................................. 60
vi
5.7.3 Recover Factory Default Setting............................................................................................................. 61

6 Account Operations............................................................................................ 63

6.1 List of Account Interfaces .................................................................................. 63

6.2 Operations of Printing Report ............................................................................ 63


6.2.1 Print Total Report.................................................................................................................................... 63
6.2.2 Print Department Report......................................................................................................................... 64
6.2.3 Print Class Report ................................................................................................................................... 65
6.2.4 Print PLU Report .................................................................................................................................... 65

6.3 Clear Report Information ................................................................................... 65


6.3.1 Clear Report Information Manually ....................................................................................................... 65
6.3.2 Clear All Reports and Records Information............................................................................................ 66
6.3.3 Clear stock information........................................................................................................................ 66
6.3.4 Reposition SID information ................................................................................................................. 67

6.4 Stock Management ............................................................................................. 67


6.4.1 Stock Management ................................................................................................................................. 67
6.4.2 Stcok Print .............................................................................................................................................. 67
6.4.3 Stock Audit ............................................................................................................................................ 68

6.5 List Print ............................................................................................................. 68


6.5.1 Sale Log ................................................................................................................................................. 68
6.5.2 List Print................................................................................................................................................ 68

7 Appendix.............................................................................................................. 70

7.1 Reference Table For Errors and Its Instructions................................................. 70

7.2 Definitions of Spec data parameters................................................................... 73

7.3 Definitions of String data paremeters................................................................. 88

7.4 Definitions of Shortcut Function Key ................................................................ 88

vii
Examples Menu
Example 3-1 Fast-Prog of PLU ............................................................................................................................... 16

Example 3-2 Fast-Prog of Shortcut Key for PLU. Amend a shortcut key. .............................................................. 18

Example 3-3 Fast-Prog of Shortcut Key for PLU. Amend two or more shortcut keys............................................ 18

Example 3-4 Fast-Prog of Spec Parameters ............................................................................................................ 19

Example 3-5 Fast-Prog of unit price (Spec083=1) .................................................................................................. 20

Example 3-6 Fast-Prog of unit price (Spec083=2) .................................................................................................. 20

Example 4-1 Use PLU Number to Transfer Weight PLU........................................................................................ 21

Example 4-2 Use PLU Number to Transfer Count PLU ......................................................................................... 21

Example 4-3 Use PLU Shortcut Keys to Transfer Weight PLU .............................................................................. 21

Example 4-4 Use PLU Shortcut Keys to Transfer Count PLU................................................................................ 21

Example 4-5 Transfer Temporary Weight PLU ....................................................................................................... 22

Example 4-6 Transfer Temporary Weight PLU with a Unit Conversion of the U.Price.......................................... 22

Example 4-7 Temporary PLU number is decided by Spec094(default 9999998) ................................................... 22

Example 4-8 Sale for Single Weight goods ............................................................................................................. 22

Example 4-9 Sale and Print for Single Count goods ............................................................................................... 23

Example 4-10 No Weigh Sale for Weight PLU ....................................................................................................... 23

Example 4-11 Sale and Print for Different Kinds of Goods (No Cashing Mode) ................................................... 24

Example 4-12 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment)................................ 24

Example 4-13 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price).................. 25

Example 4-14 Execute Discount in Subtraction ...................................................................................................... 25

Example 4-15 Execute Discount at a Fixed Number............................................................................................... 25

Example 4-16 Input data to execute ±% price ......................................................................................................... 26

Example 4-17 Enterinterface and execute ±%price................................................................................................. 26

Example 4-18 Directly execute default ±%price(Spec114)..................................................................................... 27

Example 4-19 Auto Discount................................................................................................................................... 27

Example 4-20 Unit Conversion of Temporary U.Price............................................................................................ 27

Example 4-21 Weight Tare ...................................................................................................................................... 28

Example 4-22 Number Tare..................................................................................................................................... 28

Example 4-23 Tare Lock and Unlock ...................................................................................................................... 28

viii
Example 4-24 Single key select of sale mode ......................................................................................................... 29

Example 4-25 Interface select sale mode ................................................................................................................ 29

Example 4-26 Batch Print mode.............................................................................................................................. 29

Example 4-27 Prepack mode(only for weight PLU) ............................................................................................... 30

Example 4-28 Switch of Sale Buffers...................................................................................................................... 31

Example 4-29 Clear All Data in Current Sale Buffers............................................................................................. 31

Example 4-30 Clear One Goods in Current Sale Buffer.......................................................................................... 32

Example 4-31 Inquiry of Sale Records and Markers of Returns of Goods ............................................................. 33

Example 4-32 Manual Sale of Manual Weight Entry .............................................................................................. 34

Example 5-1 Time Programme................................................................................................................................ 43

Example 5-2 Programme of Spec parameters.......................................................................................................... 43

Example 5-3 Programme of Text Parameters .......................................................................................................... 44

Example 5-4 Programme of PLU Shortcut Keys..................................................................................................... 44

Example 5-5 Programme of Fuction Shortcut Keys ................................................................................................ 45

Example 5-6 Department Programme ..................................................................................................................... 45

Example 5-7 Class Programme ............................................................................................................................... 46

Example 5-8 PLU Programme................................................................................................................................. 47

Example 5-9 Unit Programme ................................................................................................................................. 49

Example 5-10 Barcode Programme......................................................................................................................... 49

Example 5-11 Salesman Programme ....................................................................................................................... 55

Example 5-12 Steps Select of PLU Programme ...................................................................................................... 56

Example 5-13 Steps Select of PLU Fast Programme .............................................................................................. 56

Example 5-14 Delete PLU20~30........................................................................................................................... 57

Example 5-13 Load Files in USB Flash Disk.......................................................................................................... 58

Example 5-14 Save working data to Files in USB Flash Disk ................................................................................ 58

Example 5-15 Save sale list to Files in USB Flash Disk ......................................................................................... 59

Example 5-16 Enter Ethernet Monitor Interface ..................................................................................................... 59

Example 5-17 Process of Amending Passwords...................................................................................................... 61

Example 5-18 Process of Amending Passwords...................................................................................................... 61

Example 6-1 Print Daily Reports of Today and Yesterday ...................................................................................... 64

Example 6-2 Print PLU Daily Reports with the Numbers from 10 to 20 ................................................................ 65
ix
Example 6-3 Clear Information in Manual Report .................................................................................................. 66

Example 6-4 Clear All Reports and Records Information ....................................................................................... 66

Example 6-5 Clear stock information...................................................................................................................... 66

Example 6-6 Clear manual report............................................................................................................................ 67

Example 6-7 Print stock Reports with the Numbers from 10 to 20......................................................................... 67

Example 6-8 Amend PLU10 stock to 100 ............................................................................................................... 68

Example 6-9 Intraday List Print .............................................................................................................................. 68

Example 6-10 Appointed Time Period List Print..................................................................................................... 69

x
1 Components of Barcode Print Scale

1.1 Check Accessories


One Scale;
One tray;
One display pole (pole type only);
One pack of screws used to fix the pole (pole type only);
One copy User Manual (this book);
One CD for PC software TM-xA Management Software
One overlay for shortcut PLU;
One power plug;

1.2 Keyboard
1.2.1 The Original Overlay of the Keyboard

Picture 1-1 Sketch Map of Keyboard Function for barcode label printing scale (Pole)

7 8 9 X

4 5 6
1 2 3
0 00
Picture 1-2 Sketch Map of Keyboard Function for barcode label printing scale (Bench)

Picture 1-3 Sketch Map of Keyboard Function for cash register scale

1
The graph above shows the original definitions. Some buttons on the left top area are marked with numbers,
which are serial number for the shortcut keys. In this text, 【SCxx】 is used to represent shortcut keys. For
example, 【SC1】 represents the first key on the left top marked with number 1. 【SCxx】on the left side are PLU
preset shortcut keys and can be set to represent one certain key if user requests. When editing the text, 【SCxx】
are function keys and character keys for the input of letters. Please refer to chapter 1.2.4. 【SCxx】on the right side
are preset shortcut keys for additional functions . The presetting is shown in the graph. And it’s not available for
user to change the setting of function keys now.
1.2.2 Instructions for Keys
When you press right keys, the scale would beep shortly to show the operation is right.
When you press wrong keys, the scale will beep in 1 long sound and 2 short sounds. The composite beeps
mean the failure in operation process or errors in pressing keys. If operaton process fails, there will be Ex.xx
displayed on the screen (e.g., E1.01 means programme data is invalid.).
It may take 4 seconds to press one key in the operation which needs to Long Press the key without releasing
it. During the period you will hear 2 beeps. The first beep sounds as soon as you press the key while the other one
sounds 4 seconds after pressing the key.
In some【F-Prog】+【Other key】 operations, users should first press 【F-Prog】 without releasing and press
the 【Other key】 in order to complete the operation.
In the following instruction: 【Key1】
【Key2】 means the operation that press 【Key 1】first and release it,
then perss【Key 2】and release it. 【Key1】+【Key2】means the operation that press 【Key1】 and 【Key2】
at the same time. When users do it , press 【Key1】 first, and press 【Key2】 without releasing 【Key1】 .
1.2.3 Instruments for Keys in Function Area
Picture 1-1 shows the default setting of keys in the function area. According to customer’s requests, default
setting may be different. And the specific setting will be on the overlay:
【Sale】: Enter sale mode and execute the operation of goods sale.
【Prog】: Enter programme mode and programme on parameters, PLU, print formats, time and so on.
【Account】: Enter Account mode to inquire about deals data or print reports and so on.
【Time】: Display current time and return to the previous interface when you press it again.
【Tare】: Set current weight as tare or appoint certain data as tare (When there is a number in input
window, number tare is the priority.). Pressing 【Tare】 for a long time without releasing, system would
enter 【Tare Lock】. And do it again to exit this state.
【Zero】: Clear current weight and reset zero within allowed range. If not within allowed range, set zero
would fail.
【Shift】: Shife key used for extending PLU shortcut key, and switching case sensitivity in text input
interface. When current input number is decimal (tare, weight, U.Price, T.Price) , long press 【Shift】or
press 【F-Prog】+【Shift】 would change the position of decimal point.
【Auto Mode】【Pre-Pack Mode】, 【Batch-Pint mode】, 【Auto print】
【Lock PLU】: Switch ordinary
mode with pther sale mode. Users can long-press this key to enter sale mode select if current sale buffer
is empty.

2
【Manual Weight】:Key for manual entry of weight. “ManWT” will add before weight data while
printing. Open this functions in Spec if user needs it.
【Paper Type】: Long Press it switch paper between gap thermal paper and plain thermal paper.
【Re-print】: Repeat last print in current buffer (Repeated print data would not be stored in deal records
as sale record.). This function can be forbidden in Spec.
【Feed】: Roll the gap thermal paper and plain thermal paper. Unprinted buffer data will be cleared in the
process of feed.

Input
【-%】 【±%】: Discount in percentage, PDis = P(1 ± ) . Please notice that input is decimal and
100
pay extra attention to the position of decimal point. Discount is 5% off while input is 500, if there are
two zeroes after decimal point. And input should be 5000, If there are three zeroes. You can refer to
Spec113, Spec114 for detailed explaination.

【-Num】: Discount in subtraction. PDis = P − Input . Input is also decimal.

【@Price】:: Discount to a fixed price. PDis = Input . Input is also decimal. You can also use this
【-@】

key to save the discounted price to PLU directly, please refer to Spec083
【T-Sale】: Set input number as Unit Price and set a temporary PLU. You can amend the temporary
weight PLU’s unit in Spec, for example, if the temporary weight PLU’s unit is 500g, but the scaleunit is
kg, then system will antomatically conversion (multiply 2)
【Drawer】: Open drawer besides normal operations.
【Paid by card】: Obligate function
【F-Prog】: Change some setting or values of PLU fastly in sale mode. It is always used for combination
of keys, which is similar as ‘Alt’ ‘Ctrl’ in PC keyboard. Please refer to process instructions to understand
the use of combination keys.
【×】: Input count amount in count sale. Or do temporary count goods sale according to input U.Price.
【Amend】: Amend deal data in sale interface and store amended data in programme interface.
【←】【↑】
【↓】【→】: Switch among neighbouring steps and numbers in programme and account
interfaces.
【V1】~【V4】: Activate corresponding sale buffers.
【0】~【9】,【00】: Input corresponding numbers.
【Back】: Delete the last digit input number.
【PLU】: Transfer PLU datas using input numbers as serial numbers.
【Cash/Print】: Check out in cash; calculate changes and print labels or receipts according to setting.
【Cancel】: Clear data, cancel operations or go back to previous step.
【Accu/Confirm】: Save accumulative deal data into activated sale buffer and other confirmation
operations.
1.2.4 Character Input Instructions
The key of function section remains the same when system enters letters input interface, while 【SC1】~

3
【SC63】 are used to input letters. In input process, definitions of keyboard are shown below:
【Amend】: Confirm text input. Save and exit.
【Cancel】: Cancel edited data and quit without saving.
【Confirm】: Confirm the input in special IME (not used in pure English version).
【End】: Input end character, and all characters after appointed position are deleted.
【Delete】: Delete the character at the position where cursor is.
【Insert】: Switch cover mode with insert mode. Cover mode is activated when cursor is constant on
while insert mode is activated when cursor is glittering.
【IME】: Input method editor. Switch the input languages: En-1 (in small letters), En-2 (in big letters),
Chs (chinese code), Code (machine code).
【Shift】: Switch En-1, En-2 in temporary state.
【←】【→】: Move current editing position backwards or forwards.
【0】~【9】 and【SC1】~【SC59】: Input characters or codes.
In the process of input text, meanings of four windows are shown below:
The first window: Display current input mode: one of En-1, En-2, Chs and Code.
The second window: Display the position of current editing letters in the text.
The third window: Display current editing position and content of neighing letters. In En-1 or En-2
ASCII mode is displayed while in Chs or Code Hex mode is displayed. Cover mode is activated when
cursor which shows the position is constant on, while insert mode is activated when cursor is glitter.
The fourth window: Display current input content. In En-1 or En-2 the window displays nothing, and in
Code input machine code is displayed.
Switch 4 kinds of input languages by pressing switch keys. Input mode of each kind of input language is
shown below:
En-1 small letter: Input numbers or ASCII characters. For the keys with ‘/’, input character is the one on

the left of ‘/’. Pressing【Shift】, next input character and only this one is under the rule of En-2 .

En-2 capital letter: Input numbers or ASCII characters. For the keys with ‘/’, input character is the one

on the right of ‘/’. Pressing【Shift】, next input character and only this one is under the rule of En-1 .

UTF8 (U version IME, for UTF8 font scale use only): UTF-8 input method, input Unicode to get the

characters, input different kinds of non-English language characters, please check code from UTF8

Test Editor Manual, after input Unicode, press【Confirm】to finish the input

PY Chinese pinyin mode (E version IME, font scale use only): Input pinyin, and select chinese

character by【←】【→】, Press【Confirm】 to input a Chinese character. In pinyin mode, Press

【Space】to select SBC case symbol, Press 【Space】 twice to select English symbol.

Chs Chinese ISN mode (E version IME, font scale use only): Input ISN code to select a Chinese character

or SBC case symbol.

Code: Input machine code mode. Users can input ASCII, symbols in special IMEs. The system could

4
automatically distinguish the input content as ASCII, symbols in special IMEs. Machine codes of

each field can be found in following table.


Table 1-1 ASCII Code Table
0 1 2 3 4 5 6 7 8 9 A B C D E F
0
Non-print character
1
2 ! “ # $ % & ‘ ( ) * + , - . /
3 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4 @ A B C D E F G H I J K L M N O
5 P Q R S T U V W X Y Z [ \ ] ^ _
6 ` a b c d E f g h i J k l m n o
7 p q r s t U v w x y Z { | } ~ 
8
Not used
9

1.3 Display Panel


1.3.1 Sketch Map of Display Panel

Picture 1-4 Display Overlay

Picture 1-5 Display Overlay with Dot-matrix Display

1.3.2 Indication Signs


〖Zero〗: It’s on when weight is zero and stable.
〖Stable〗: It’s on when weight is stable.
〖Lock Tare〗: It’s on when tare is locked. Long press 【Tare】 would lock tare. Under this condition, tare
would not be cleared after the sale. Long press 【Tare】 again would exit lock tare.
〖Lock PLU〗: It’s on when PLU is locked. Long press 【PLU】 would lock PLU. Under this condition,

5
former PLU sale state would remain the same after the sale. And it will last until new PLU is transferred.
Long press 【PLU】 again would exit lock PLU.
〖Auto mode〗: It’s on in auto mode. When in auto mode, lock PLU will active. In this mode, pre-pack or
batch print is executed based on Spec078 and Spec079.
〖Pre-pack〗same as 〖Auto mode〗
〖Auto Print〗the light will on when in auto printing
〖Manual Weight〗:It’s on when manual weight is displayed.
〖Gap paper〗: It’s on when paper type is gap paper. If it’s off when paper type is plain paper.
〖NET〗: It’s on when tare is set and net weight is displayed. Press 〖Fast Prog〗
〖Tare〗will display
gross weight
〖Shift〗: Press 【Shift】 and it is on.
〖Sale〗: It’s on in sale mode.
〖Prog〗: It’s on in programme mode.
〖Account〗: It’s on in account mode.
〖Change〗: It’s on when the data in third window is displayed as cash change.
〖U.Price〗: It’s on when the data in third window is displayed as goods U.Price.
〖V1〗~〖V4〗: It’s on when there are buffers in V1~V4 records. And it’s glittering in edit mode.
〖Discount〗: To display single means that current goods has been discounted in U.Price; To display total
means that current accumulative total has been discounted in T.Price
〖Single〗: It’s on when total price of current goods is displayed in fourth window.
〖Sum〗: It’s on when the sum total price of current sale buffers (V1~V4) is displayed in fourth window.
1.3.3 Expression of Characters

Picture 1-6 Number Characters 0~9

Picture 1-7 Characters A~M

Picture 1-8 Characters N~Z

Picture 1-9 Dash、underline, aboveline, three lineations of special symbols

6
Dash of special symbols: the same as ‘-’ in ASCII.
Underline of special symbols: Used to represent the characters which cannot be displayed in ASCII(the
symbols except 0~9, A~Z and ‘-’)
Aboveline of special symbols: Used to represent extended characters. In Chinese edition, two aboveline
represent a Chinese character.
Three lineations of special symbols: In calibrating processes, it’s used as a prompt to decide to enter
calibrating interface or standard interface.
1.3.4 Dot Matrix Display
5-windows scales have an additional 160×32 dot matrix LCD display. It displays time or ad-message or
accumulation record in idle mode; and displays PLU’s name in PLU mode.

1.4 Specifications
Power supply: AC200V~240V, 47~53Hz
Operation temperature: 0℃~40℃
Conservation temperature: -20℃~70℃
Operation humidity: 15%~85%RH

Capacity Resolution Division Accuracy

6kg 3000 2g III

15kg 3000 5g III

30kg 3000 10g III

1.5 Thermal Printer (bar code label printing scale only)


1.5.1 Install Gap Paper
Install process is as below: Left is drawer structure (08’s). Right is cover structure (12’s)

1.Open Upper door

1.Open side door

Picture 1-10 Open door of scale printer

7
Hook

Raise Fall

2.Raise the print head 2.Move hook in direction of arrow


Picture 1-11 Open press mouth

4.Rotate LIMIT 3.Rotate up LIMIT 4.Install


90 ,for paper paper roll
pass though

3.Install
paper roll

Picture 1-12 Install paper roll

5.Paper get through 5. Paper get through

7.Roll paper

7. Roll Paper
6.Remove U Spring 6. Remove U Spring

Picture 1-13 Paper through


9.Press down header 10.Adjust LIMIT height

10.Adjust
LIMIT height

8. Sandwich paper
9.Close header by U spring
8.Sandwich paper by U spring
Picture 1-14 Finish paper install

11.Cover door

12.Press【Feed】
12.Press【Feed】

11.Close door
Picture 1-15 Close door of scale printer

8
1.5.2 Gap Paper Mounts Recycle

Pull out spring


Picture 1-16 Gap paper mounts recycle

1.5.3 Install Plain Paper


Different from the way in installing gap paper shown in 1.5.1, U-shaped paper retaining spring is not needed
anymore. All you need to do is to put the paper into the paper sensor and let the tear part be outside.
1.5.4 Operations Concerning Paper
【Paper Type】: Make sure the type of paper set is the same as the type used. When 〖Gap Paper〗is light
in the display, you should set to use gap paper. Otherwise you should set to use plain paper. If the type of
paper you set to use is different from the type currently used, please long press 【Paper Type】to change
the set.
【Feed】: After installing the paper, press【Feed】. You can also press 【Feed】 to clear abnormities of
the printer and make paper roll for a certain length.
1.5.5 Abnormity of Gap Paper Print
Users of plain paper don’t do any adjustment for this.
Abnormity of printer parameters may happen when gap paper prints are unnormal, paper goes out
continuously, or printer can’ work after one paper is printed, printing parameter maybe have abnormity
Users need to check if paper type is right first. Then users could follow these operations below to eliminate
malfunctions:
Install gap paper, and make the edge of gap paper not exceed print head. (Not block the paper-out sensor)

Picture 1-17 Paper-Out sensor

Switch off the scale. Press the 【Feed】key then swith on the scale, hold this key until finished self
checking and go into work inteface
Printer would roll out the paper at the length of 50mm. automatically
After the paper is rolled out, malfunctions have been eliminated if without any warning. If alarm E7.10
means calibration abnormity, pls try again after confirming the sticker perper has been used.

9
Then, press 【Feed】to print the test page
Go to normal operation processes.
1.5.6 Specification for printing interface
Window Tare Weight/Count CHG/Unit Price U.Weight/T.Weight
Sample E7.1x P1-02 Print
If normal printing, this When mass Display present printing
When printing
window is blank, if printing, this doc and number. P1-01
display: Print
have error, will display window will means the 2nd page of
Specification
erro message, the display the Doc 1. If total print 1
Not Printing wil
mean for message pls number rest page, this window will
display blank.
refer to Addenda 7.1 unprinted. blank.

10
2 General Functions, Configuration and Using Index

2.1 General functions


The printer can store 5990 PLUs. (Can extend to 10000 PLUs)
Users can use gap thermal paper (TM-xA Series) and plain thermal paper.
The printer provides many kinds of price input and discount.
The print provides reports print for different time periods and classifications
Precision of measurement: business mode 1/6000 (1/7500 for 15kg), industrial mode 1/30000.
Support network, use RS232 and U disc as tool of data transer, all data can set on the PC, then use these
interface to upload and download.
Save sales details, can upload to PC through above interface
5-windows scales have an additional 160×32 dot matrix LCD display.

2.2 Setting of Print Format


Bar Code Printing Scale: Press 【Paper Type】 for 4 seconds to switch between gap paper and plain
paper. This key would amend Spec021.
Bar Code Printing Scale: There are 9 kinds of default print formats. Please reference to Factory Default
Print Formats in page 52.table 5-5
Bar Code Printing Scale: 58mm*40mm and 40mm*30mm gap paper, 58mm and 40mm width plain
paper are available in default print formats. When using different type of paper, please adjust the
corresponding Spec shown in the table below.
Spec
Paper type Print type Instructions
000 005 027
58mm*40mm Label print 1 4 50 Default
gap paper Receipt print 7 7 50 Not recommend
40mm*30mm Label print 2 5 36
gap paper Receipt print 8 8 36 Not recommend
58mm width Label print 1 4 50
plain paper Receipt print 7 7 50
40mm width Label print 2 5 36
plain paper Receipt print 8 8 36
Cash Register Scale: Cash register scale preset support 55mm width plain paper, default using recept
printing format
Print formats include label print and receipt print. If user needs custom print format, please use PC
software to change or contact with appointed after-service cencer.
Don’t print bills while saling: amend Spec003 and Spec008 to 0. If some specific deals need to print bills,
please press 【Reprint】.
To print a few copies of one bill, put the amount into Spec003 and Spec008.

11
To print two different kinds of bills: set the type of bill 1 in Spec000~Spec009, and bill 2 in
Spec010~Spec019. Strongly suggest users contact with appointed after-service cencer
Set grey level of gap thermal paper in Spec022.
Set grey level of plain thermal paper in Spec023.
Set plain thermal paper in Spec 025, the position for cut-off paper suggest Spec025 not less than 30
You can set different kinds of print formats and barcode types for each PLU. You can check the details in
PLU parameters for print formats and barcode types. Set the value of these parameters to 0 if you choose
the system type.
The procedures to confirm print format: take bill 1 as an example. If two or more goods are sold, print
sum bill and use Spec005 as print format. If only one good is sold, print the item bill. If sale PLU has
been set for a specific print format (not 0), system would use the print format. If no specific print format
has been set to sale PLU (The setting number is 0.), the print format would be Spec000.

2.3 Barcode printing and scanning


Can print various kinds of bar code, 9 kinds of default barcode settings, details in page 51 Table 5-4
Factory Default Barcode.
Can scan inner code and external code, details in page 34, the specification of Bar code printing and
scanning
Barcodes can be divided by use into item barcodes and total barcodes, which are printed in item labels
and total labels respectively.
Factory default barcodes support 5-digits total price and 6-digits total price. Please select the barcode
compatible with the POS
Digits Spec
Goods Code Suggestion
of Price 001 006 002 007
5 x…is the flag code which is reserved for
1 7 xx xx00000
Flag Code Default scale in POS system. User could define
Using PLU No. 0 as a MISC code for PLU Number
6 4 8 xx xx0000
never equal to 0.
x…is the flag code which is reserved for
Flag Code 5 2 7 xx xxyyyyy
scale in POS system. y… is a MISC
Using PLU
code for total label. PLU’s Item-Code is
Item-Code 6 5 8 xx xxyyyy
code in POS system.

No Flag Code 5 3 7 yyyyyyy No flag code defined. y… is a MISC


Using PLU code for total label. PLU’s Item-Code is
Item-Code 6 6 8 yyyyyy code in POS system.

If users need special bar code format, please use PC suite or contact with after-service center.

2.4 Measure Functions


The scale offers 6 default measure units as kg, gram, ton, lb, 500g, 100g.
Based on the difference national regulations, some of the measure unit may Not Open. The combinations

12
and recommended Spec settings are all shown below:
Weight U.Price Spec
Instructions
display display 212 211 200 201 208
kg /kg 3 0or 3 3 3 3 Default
g /g 4 0or 4 0 0 0
g /100g 4 8 0 0 0
lb /lb 6 6 3 3 3
Weight precision: The precisions are divied into four levels. Level 0 owns original 1/3000. Level 0 and
level 1 are available for commercial users while level 2 and level 3 are only available for industrial users
(“*” would be attached in the print of weight). Please refer to Spec213.
We guarantee the stability and reliability for precision level 0 (1/3000) when the scale leaves factory. And
the higher precisions are here to satisfy the need of high definition print for some users, so factory would
not guarantee the stability and reliability for higher precision levels for every scale. Please choose the
precision prudentially.
The request Zero-Return for scale print: it’s requested in commercial sales that total weight (sum of net
weight and tare weight) of the scale have to return to zero when the scale is going to print the weights of
two goods. But for industrial users, this rule could be ignored. Set the value of Spec069 to 2. (“Ind”
would be attached in the print of weight).

2.5 Sale Functions


Users could operate accumulative sales with 4 customers at the same time. Please refer to the Example
4-28 in page 31 for operations.
Rounding methods could be divided into rounding method for single and rounding method for total. The
settings of rounding methods are shown in Spec100 and Spec101.
Suggest that set the value of Spec100 to 1 if users don’t want the unit “cent” to be displayed in sales.
Suggest that set the values of Spec100 to 0 and Spec101 to 1 if users want the unit “cent” to be in sale
while unit “cent” is not displayed in grand total and print.
The units’ conversion for PLU default U.Price: set PLU U.Price to 10.00, the unit is 500gram and unit
displayed is kg. When transfer PLU10, unti price is displayed as 20.00.
Units’ conversion for temporary unit price: the scale offers the function of units’ conversion for
temporary unit goods and price from 500gram to kg. When U.Price’ display unit is /kg, set the value of
Spec210 to 7 and the value of Spec073 to 1 to activate this function. Please refer to the Example 4-6 in
page 22, Example 4-20 in page 27.
No Weigh Sale for Weight PLU: set the value of Spec071 to 1. When the weight returns to zero in weigh
sale, input the price and sell the goods at the price you input. Please refer to Example 4-10 in page 23.
Users can discount on U.Price and T.Price conveniently. The discount methods include discount at a fixed
number, discount in subtraction and discount in percentage. Please refer to Discount Operations in page
25.
Users can make a manual weight sale: set the value of Spec077 to non-zero (1, 2 or 3 are ok). Manual

13
weight entry can be executed if weight keeps at zero. Refer to the content of <manual weight> on page 1
Total price Masked before printing: set the value of Spec130 to 1. It will not display current transaction
amount till press 【Print】key
Auto record after zero-return set the value of Spec 131 to 1 or 2 (1:unforced 2:forced)., scale still record
the transaction in un print condition, convenient to check and audit
Auto printing after zero-return: set the value of Spec131 to 3. In weight sale, it will come back to zero in
PLU, it will print according to last stable weight.
Forced auto printing after zero-return: set the value of Spec131 to 4. In weight sale, when record and
valid sale data it will auto printing after zero-return enable while user can not cancel the auto print by
quit the PLU.

2.6 Salesman Function


User could enable salesman login functions. Please refer to Salesman in page 32 and Spec135.

2.7 Report Functions


Users could print the total reports with time periods of last 32 stat. day, stat. month, stat. quarter or
manual time period.
Users can print the reports for all departments, all classes and part of PLU (below 1000), with a time
period of present stat. day, stat. month, stat. quarter or manual time period.
Please refer to Account Operations in page 63 for the details.

2.8 Sales details


The scale not only with report print function,but also store the sales record in details, this record can
transfer to PC via internet, RS232 or U-disk.
Because the storage room limit, if operator don’t transfer the details often, the scale will delete the old
record automatically to save the new records.
The storage for the sales details is 6000 records (can enlarge into 10000 and more). Each cargo takes one
record.

2.9 Network function


In local area network with a PC or Router enabled DHCP service, scales can connect to network directly
without any IP setting.
If you want to nominate the IP for certain scale, to set Spec150~153 is for 4 segment of IP(Default is
192.168.0.0. When last segment is 0, that means scale connect with Network with way of DHCP. Also
means that default way is DHCP), Spec158~161 is for 4 segment of gateway of Network. (Default is
192.168.0.1).
If the Network for the scale and PC is not in the same one, you can make that with directional connect
way. Directional connect include: From PC to scale (should nominate the IP of certain scale on the PC
software), and from scale to PC(should set Spec043 as 2-----client end mode, and set IP of PC at

14
Spec154~157)
Spec166~Spec169 is for the scale’s Network Port, change these items may lead to abnormality with
Network. Normally please don’t modify these 4 items.

2.10 Ethernet Thermal Printer


Device can connect with Ethernet thermal printer produced by our company, which uses as Remote
Printer.
User can connect Printer and device one-to-one with Crossover Cable. Or connect printers and devices to
Ethernet router (with DHCP function) for one-to-many, many-to-one, or many-to-many network.
User can appoint special print format for Ethernet printer, which may different to printer on the device.

2.11 Software use


In the CD, there is software manual, you can kindly install and use according to the manual.
The user name of the PC software is user, the original password is blank.
The administer name of the PC software is admin, the original password is 200806.
You can click Help----Manual after run the software, to check the software manual.

15
3 Fast Prog
Fast prog is the programme operation that draws out some frequently-used programme functions and enables
users enter certain frequently-used programme interfaces without selecting in programme interface.
Please make sure system is in the interface of idle sale before transferring fast prog. If system is not in sale
operation, pressing 【Sale】 could enter the interface of idle sale. If system is in sale operation, pressing 【Cancel】
for several times could quit sale process and enter the interface of 『Sale Idle』. The sign of the interface of idle
sale is that two lights 〖Sale〗 and 〖Sum〗 are on. On contrary, if two light of 〖Sale〗 and 〖Single〗 are
on , system is in sale PLU interface.

3.1 Fast-Prog of PLU


Press 【F-Prog】+【PLU】 to enter PLU Fast Prog.
The process of programme is similar with PLU programme in standard programme interface. But users can
finish PLU Fast Prog in sale interface.
Example 3-1 Fast-Prog of PLU

Edit PLU10 as a weight PLU with the name Pork-2, U.Price $30.00/kg, cost $24.00/kg and tare 0.005g.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗,〖Sum〗on.
【F-Prog】+ F23 PLU.00 Not Set 0
PLU Fast Prog 〖Prog〗on.
【PLU】 Step No. Step Info Object
PLU Number 【1】【0】 F23 PLU.00 Not Set 10 Number are between 1~9999999
Go to Next 【 】 F23 PLU.01 ICode 0
ICode is Item-Code, which is usually
printed as part of letters on barcode
Input print. If the number of barcodes is
90001 F23 PLU.01 ICode 90001
Item-Code default 2/5 or other custom numbers,
ICode are printed as a part of barcodes.
Please see details in chapter Barcode.
Go to Next 【 】 F23 PLU.03 Unit 0
【0】,【1】: default weight unit;
【2】: default count unit;
【3】: kg weight unit;
【4】: g weight unit;
【5】: ton weight unit;
Set as weight 【6】: lb weight unit;
【1】 F23 PLU.03 Unit 1
PLU 【7】: 500g weight unit;
【8】: 100g weight unit;
Please see details in unit chapter.
Default weight unit mean the unit used
for display. And it is suggested for
weight PLU.
Go to Next 【 】 F23 PLU.04 Price 0.00

16
Preset U.Price in sale. Don't have to
Set U.Price 【3】
【0】
【00】F23 PLU.04 Price 30.00 input it. Users can temporarily input it
in sale.
Go to Next 【 】 F23 PLU.05 Cost 0.00
The cost is used to calculate the profits.
Set cost 【2】
【4】
【00】F23 PLU.05 Cost 24.00
Don’t have to input it.
Go to Next 【 】 F23 PLU.06 Tare 0.000
When transferring PLU, it’s preset tare.
Set Tare 【5】 F23 PLU.06 Tare 0.005
Don’t have to input it.
Go to Next 【 】 F23 PLU.14 Name OK-Edit Input the names of goods.
Set name 【Confirm】 En-1 0
In consideration of there was a text, we
suggest users press 【End】 before
Clear Original
【End】 EN-1 0 editing. If editing in the original text,
Text
users could use【 】 【 】 to move the
position of cursor.
P 【Shift】
【p/P】EN-1 1 P
【o/O】【r/R】
ork EN-1 4 rk
【k/K】
- 【-】 EN-1 5 k-
Input number
【2】 En-1 6 -2
2
This 【Amend】 is to save text edit in
buffers instead of PLU. Please pay
Save edited
【Amend】 F23 PLU.14 Name OK-Edit attention: If users need save it in PLU,
text
users need to press【Amend】 again as
the step below.
Go to next 【 】 F23 PLU.26 PS-UD 0 If to print the shelf life date
0: Don't print PLU 31 invalid
Print shelf date 【1】 F23 PLU.26 PS-UD 1 1: Print. Continiune to set shelf days in
PLU.31
Go to next 【 】 F23 PLU.31 PC-UD 0 Shelf days. 0 means intraday valid,
followed like this.
Input shelf
【 】 F23 PLU.31 PC-UD 3 If all cargo for one scale use same shelf
days
days, use Spec105 & Spec106
If other steps are still to be edited, users
……
can use 【 】【 】 to switch steps.
Save edited
【Amend】 F23 PLU.00 Not Set 0 PLU10 is saved.
PLU
Return to sale 【Cancel】 0.000 0.000 0.00 0.00 〖Sale〗,〖Sum〗 on
N o t e 1 Except the parts which have been instructed, meaning of the other words are listed in List of
Programme Interface in page 37.
N o t e 2 PLU fast-prog is forbidden when Spec080=0.
N o t e 3 Before you move to next step, the display of E1.01 Data Invalid means that the programme data you
input is invalid.
N o t e 4 The xx in PLU.xx means the content in the data which is marked with the number of xx in PLU fast

17
prog.
N o t e 5 Xx is not continuous when users press【 】and【 】to select the programme content. There are two
reasons. First reason is that the content in that part is meaningless. For example, tare is not present in
count PLU programme. The second reason is that the content in that part is seldom used and has been
set as non-programme content (Skip) in P3.01 and P3.02. Users could change that setting for personel
usage. Please refer to corresponding chapters for details.

3.2 Fast-Prog of Shortcut Key for PLU


Press 【F-Prog】+【SCxx】to enter PLU shortcut key programme. 【SCxx】could be one of 【SC1】~
【SC63】. After pressing one key, Users can input the PLU which the pressed key appoints to .Then press
【Amend】to save and exit.
Users can save without exit if they would like to go on to amend other shortcut keys. Press 【Confirm】 to
save the change and press another 【SCxx】 to amend. The number of input PLU must exist. User can select
existing PLU by pressing 【↑】【↓】. The process of programme is similar with scPLU programme in standard
programme interface. Please refer to the process shown below.
Example 3-2 Fast-Prog of Shortcut Key for PLU. Amend a shortcut key.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
PLU shortcut key F14 scPLU 0-01 0
【F-Prog】+
programme, and the 〖Prog〗on.
【SC1】 Key No. PLU No.
object is SC1
Input PLU number 【1】【0】 F14 scPLU 0-01 10
Save to the scale.
Save directly 【Amend】 0.000 0.000 0.00 0.00
〖Sale〗, 〖Sum〗 on
N o t e 1 When Spec081=0, PLU shortcut-key fast-prog is forbidden.
Example 3-3 Fast-Prog of Shortcut Key for PLU. Amend two or more shortcut keys.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
PLU shortcut key F14 scPLU 0-01 0
【F-Prog】+
programme, and the 〖Prog〗on.
【SC1】 Key No. PLU No.
object is SC1
Input PLU number 【1】【0】 F14 scPLU 0-01 10
Confirm input 【Confirm】 F14 scPLU ------ ------- Save to temporary buffer.
Set SC2 【SC2】 F14 scPLU 0-02 0
Input PLU number 【1】【1】 F14 scPLU 0-02 11
Confirm input 【Confirm】 F14 scPLU ------ ------- Save to temporary buffer.
Set Shift+SC1 【Shift】【SC1】 F14 scPLU 1-01 0
Input PLU number 【1】【0】【0】 F14 scPLU 1-01 100

18
Save to temporary buffer.
The last confirm can be
Confirm input 【Confirm】 F14 scPLU ------ -------
skipped. Press 【Amend】
directly.
Save to the scale.
Save 【Amend】 0.000 0.000 0.00 0.00
〖Sale〗, 〖Sum〗 on.
N o t e 1 When Spec081=0, PLU shortcut key fast prog is forbidden.

3.3 Fast-Prog of Spec Parameters


Press 【F-Prog】+【Prog】 to enter Spec parameters fast prog.
Please select the number you want to edit by pressing 【←】
【→】. The second window shows the number of
Spec which is being edited. The third window shows current parameters configuration. The fourth window shows
the data which has been edited by users.
Spec data parameters are made up of some number data. Refer to Definitions of Spec data parameters
in page 73 in order to understand functions of these parameters.
Press 【Amend】 to save and quit, or press【Cancel】to quit without saving. The process of programme is
similar with Spec programme in standard programme interface. For details, please refer to the process shown
below.
Here, we are going to amend Spec000 to 2, Spec002 to 77 and Spec040 to 99. We would present the
processes without discussing on the parameters we actually amend and their meanings.
Example 3-4 Fast-Prog of Spec Parameters
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
【F-Prog】+ F12 SP.000 1 1
Spec fast prog 〖Prog〗on.
【Prog】 Spec No. Origin Set Current Set
Change to 2 【2】 F12 SP.000 1 2
Using【 】 【 】 can only
Enter Spec002 【 】【 】 F12 SP.002 0 0 get to amend items in Spec
amend level 0.
Change to 77 【7】【7】 F12 SP.002 0 77
Choose steps directly 【×】 Input 1-1 0
The input number of step
must be in Spec amend
Input step 40 【4】【0】 Input 1-1 40
level 0 or 1. If not, the step
cannot be reached.
Confirm step 【Confirm】 F12 SP.040 0 0
Change to 99 【9】【9】 F12 SP.040 0 99
Save and exit 【Amend】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
N o t e 1 Spec fast-prog programme is forbidden when Spec082 = 0.
N o t e 2 Refer to Definitions of Spec data parameters in page 73 to know the definitions of data parameters .
Note 3 Read the definition of the parameter before you change it. And don’ t change any unknown

19
parameters in Spec programme.
N o t e 4 xxx in SP.xxx means the number of the data content in Spec programme.
N o t e 5 xxx is not continuous when users press 【 】and【 】 to select the programme content. Users can
only select Spec in level 0 by pressing 【 】and【 】. You have to input corresponding numbers
afterting pressing 【×】to change Spec in level 1. And users cannot reach Spec in level 2 and level 3
because their data are involved with some specifications in measurement and other hardware fields.

3.4 Fast-Prog of Unit price


After transfer PLU, press 【-@】or【@Price】 to fast change this PLU’s price
Example 3-5 Fast-Prog of unit price (Spec083=1)
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on
Transfer PLU10 【1】 【0】【PLU】0.000 0.000 5.00 0.00
Input the ameneded
【6】【0】【0】 0.000 0.000 6.00 0.00
price
PLU10’s default price change to
Amend price Long press【-@】0.000 0.000 6.00 0.00
6.00
Exit 【Cancell】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
N o t e 1 When Spec083=1, the step to amend unit price please refer to step 2: first judge whetherthe input
price in discount section or not, then set the accordant price as PLU’s default price
Example 3-6 Fast-Prog of unit price (Spec083=2)
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on
Transfer PLU10 【1】 【0】【PLU】0.000 0.000 5.00 0.00
Input the ameneded
【6】【0】【0】 0.000 0.000 6.00 0.00
price
PLU10’s default price change to
Amend price 【-@】 0.000 0.000 6.00 0.00
6.00
Exit 【Cancell】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
N o t e 1 When Spec083=2, during the unit price amend, it will not judge the rationality of the imput price and
directly save as PLU’s default price

20
4 Sale Operations

4.1 Transfer and Lock of PLU


PLU9999999 is temporary by-weight goods (Spec93), PLU9999998 is temporary by-count goods (Spec94),
PLU9999997 is service charge (Spec95), user can use all other 7 digits PLU.
4.1.1 Transfer by Using PLU Number
Example 4-1 Use PLU Number to Transfer Weight PLU

Transfer PLU10, assuming PLU10 is a weight PLU with U.Price $2.00/kg and tare 0.100kg.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Input number 【1】【0】 0.000 0.000 0.10 0.00
Transfer PLU 【PLU】 0.100 -0.100 2.00 0.00 〖U.Price〗, 〖Single〗 on.
Clear current PLU 【Cancel】 0.000 0.000 0.00 0.00
Example 4-2 Use PLU Number to Transfer Count PLU

Transfer PLU11, assuming PLU11 is count PLU with U.Price $5.00/pc.


Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Input number 【1】【1】 0.000 0.000 0.11 0.00
Transfer PLU 【PLU】 5.00 0.00 〖U.Price〗, 〖Single〗 on.
Clear current PLU 【Cancel】 0.000 0.000 0.00 0.00
4.1.2 Tranfer by Using PLU Shortcut Keys
Example 4-3 Use PLU Shortcut Keys to Transfer Weight PLU

Transfer SC1, assuming SC1=PLU10 and it is a weitht PLU with U.Price $2.00/kg and tare 0.100kg.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Input shortcut key 【SC1】 0.100 -0.100 2.00 0.00 〖U.Price〗, 〖Single〗 on.
Clear current PLU 【Cancel】 0.000 0.000 0.00 0.00 〖Sum〗 on
Example 4-4 Use PLU Shortcut Keys to Transfer Count PLU

Transfer SC2, assuming SC2=PLU11 and it is count PLU with U.Price $5.00/pc.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Input shortcut key 【SC2】 5.00 0.00 〖U.Price〗, 〖Single〗 on.
Clear current PLU 【Cancel】 0.000 0.000 0.00 0.00 〖Sum〗 on

21
4.1.3 Transfer Temporary Weight PLU
Example 4-5 Transfer Temporary Weight PLU
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Input Unit Price 【1】【3】【0】 0.000 0.000 1.30 0.00
Set as a temporary
【T-Sale】 0.000 0.000 1.30 0.00 〖U.Price〗, 〖Single〗 on.
weight PLU,
Clear current PLU 【Cancel】 0.000 0.000 0.00 0.00 〖Sum〗 on.
N o t e 1 Temporary weight PLU could be converted into count PLU if users press【×】or the weight is zero.
N o t e 2 Temporary PLU’s number are decided by Spec093 (the default is 9999999)
Example 4-6 Transfer Temporary Weight PLU with a Unit Conversion of the U.Price.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Input Unit Price 【1】【7】【0】 0.000 0.000 1.70 0.00
Set as a temporary
〖U.Price〗, 〖Single〗 on.
weight PLU, and 【T-Sale】 0.000 0.000 3.40 0.00
Convert unit between 500g/kg
convert its unit.
Clear current PLU 【Cancel】 0.000 0.000 0.00 0.00 〖Sum〗 on.
N o t e 1 Assume temporary weight unit is 500g (Spec210) and the unit of scale is kg. After input the U.Price
of 1.70 and press 【T-Sale】, the U.Price is converted into 3.40. That means the conversion of the unit
between 500g and kg is done.
4.1.4 Transfer Temporary Count PLU
Example 4-7 Temporary PLU number is decided by Spec094(default 9999998)
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Input Unit Price 【1】【7】【0】 0.000 0.000 1.70 0.00
Set as a temporary
【×】 1 1.70 1.70 〖U.Price〗, 〖Single〗 on.
count PLU
Clear current PLU 【Cancel】 0.000 0.000 0.00 0.00 〖Sum〗 on.

4.2 Manual Goods Sale


4.2.1 Sale and Print of Single Weight Goods
Example 4-8 Sale for Single Weight goods

Sell 1 kg PLU10 goods. Assume PLU10 is a weight PLU with U.Price is $2.00/kg and tare is 0.100kg.

22
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】
【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Put on a weight 0.100 0.900 2.00 1.80
Print 【Print】 0.000 0.000 0.00 0.00 Execute print.
N o t e 1 Two qualifications are indispensable when directly print without accumulating: 1. Current
accumulative buffer is empty, 2. The value of Spec060 is not 3 (forbid cashing mode with default zero
change).
N o t e 2 The system would have to wait for several seconds if users sell the weigh goods when the display of
weight is not stable. If the display of weight is stable in the waiting time, system would sell the goods
according to the operations. Please refer to Spec151 about the waiting time.
4.2.2 Sale and Print of Single Count Goods
Example 4-9 Sale and Print for Single Count goods

Sell 5pcs PLU11. Assume PLU11 is count PLU with U.Price is $5.00/pc.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU11 【1】【1】【PLU】 5.00 5.00 〖U.Price〗,〖Single〗on.
Input PLU11 amount 【×】【5】 5 5.00 25.00
Print 【Print】 0.000 0.000 0.00 0.00 Execute print.
N o t e 1 Two qualifications are indispensable when directly print without accumulating: 1. Current
accumulative buffer is empty, 2. The value of Spec060 is not set to be 3 (orbid cashing mode with
default zero change).
4.2.3 No Weigh Sale for Weight Goods
Example 4-10 No Weigh Sale for Weight PLU
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】 【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Input T.Price of goods 【3】【8】【0】 0.100 -0.100 3.80 0.00
Execute print. Or press
Print 【Print】 0.000 0.000 0.00 0.00 【Confirm】 to do cumulate
operations.
N o t e 1 To execute no weigh sale, the value of Spec071 needs to be set to 1 while the default value is 0.
N o t e 2 Temporary goods’ no weigh sale is not restricted by Spec071. And it could automatically convert to
count sale for temporary count goods.

23
4.2.4 Sale and Print for Different Kinds of Goods (No Cashing Mode)
Example 4-11 Sale and Print for Different Kinds of Goods (No Cashing Mode)

Sell 1kg PLU10 and 5pcs PLU11. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg,
PLU11 is count PLU with U.Price $5.00/pc.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】 【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Put goods PLU10 on 0.100 0.900 2.00 1.80
Confirm a goods 【Confirm】 0.000 1.000 0.00 1.80 〖Sum〗on.
Take goods PLU10 off 0.000 0.000 0.00 1.80
Transfer PLU11 【1】 【1】【PLU】 5.00 5.00 〖U.Price〗,〖Single〗on.
Input the number of
【×】【5】 5 5.00 25.00
PLU11
Confirm a goods 【Confirm】 0.000 0.000 0.00 26.80 〖Sum〗on.
Print 【Print】 0.000 0.000 0.00 0.00 Execute print.
N o t e 1 Users can execute no cashing mode when the value of Spec60 is 0 or 1.
4.2.5 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment)
Example 4-12 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment)

Sell 1kg PLU10 and 5pcs PLU11. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg,
PLU11 is count PLU with U.Price $5.00/pc. Payment is $30.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】 【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Put goods PLU10 on 0.100 0.900 2.00 1.80
Confirm a goods 【Confirm】 0.000 1.000 0.00 1.80 〖Sum〗on.
Take goods PLU10 off 0.000 0.000 0.00 1.80
Transfer PLU11 【1】 【1】【PLU】 5.00 5.00 〖U.Price〗,〖Single〗on.
Input the number of
【×】【5】 5 5.00 25.00
PLU11
Confirm a goods 【Confirm】 0.000 0.000 0.00 26.80 〖Sum〗on.
Input payment amount 【3】【0】【00】0.000 0.000 30.00 26.80
〖Change〗, 〖Sum〗 on.
Print 【Print】 3.20 26.80
Execute print.
Press any key to return. Or wait
several seconds to exit
0.000 0.000 0.00 0.00
according to the system setting
of Spec066.
N o t e 1 Cashing mode is available and change interface is displayed when the value of Spec060 is 1, 2, or 3.

24
4.2.6 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price)
Example 4-13 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price)

Sell 1kg PLU10 and 5pcs PLU11. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg,
PLU11 is count PLU with U.Price $5.00/pc. Payment is $26.80.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】 【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Put goods PLU10 on 0.100 0.900 2.00 1.80
Confirm a goods 【Confirm】 0.000 1.000 0.00 1.80 〖Sum〗on.
Take goods PLU10 off 0.000 0.000 0.00 1.80
Transfer PLU11 【1】 【1】【PLU】 5.00 5.00 〖U.Price〗,〖Single〗on.
Input the number of
【×】【5】 5 5.00 25.00
PLU11
Confirm a goods 【Confirm】 0.000 0.000 0.00 26.80 〖Sum〗on.
If payment equal to
0.000 0.000 0.00 26.80
price, don’t input.
〖Change〗, 〖Sum〗 on.
Print 【Print】 0.00 26.80
Execute print.
Press any key to return. Or wait
several seconds to exit
0.000 0.000 0.00 0.00
according to the system setting
of Spec066.
N o t e 1 Cashing mode without input the amount of payment is available and change interface is displayed
when the value of Spec060is set to 2.

4.3 Discount Operations


4.3.1 U.Price Discount
The data after discount should be within the discountable area. If the data exceeds the area, discount
operation would fail.
Example 4-14 Execute Discount in Subtraction

Discount in U.Price: discount at the subtraction of $0.10/kg. Assume that PLU10 is weight PLU with U.Price
$2.00/kg and tare 0.100kg.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】 【0】
【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Input discount data 【1】【0】 0.100 -0.100 0.10 0.00
Discount in subtraction 【-Num】 0.100 -0.100 1.90 0.00 〖Discount〗on.
Example 4-15 Execute Discount at a Fixed Number

Discount in U.Price: discount the U.Price to $1.80/kg. Assume that PLU10 is weight PLU with U.Price

25
$2.00/kg and tare 0.100kg.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】 【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Input discount data 【1】【8】【0】 0.100 -0.100 1.80 0.00
Discount at a fixed
【-@】 0.100 -0.100 1.80 0.00 〖Discount〗on.
number
4.3.2 T.Price Discount
The operations of T.Price discount and U.Price discount are the same. Under the condition that PLU is not
transferred and with accumulative buffers, execute discount operation is to discount on T.Price. The processes are
not repeated here. The limit of discount on T.Price is a accumulative value of U.Price discount limits of all goods.

4.3.3 ±% price
【±%】key and【-%】ket are the same key. When ±% price, the data object is floating-point decimal
fraction. For the same 5% discount, if input data is two digit decimal fraction, you need input 500; if with three
digit decimal fraction, then input 5000. you can long press【Shift】or【Fast prog】+【Shift】to change the decimal
point site.
Example 4-16 Input data to execute ±% price

100.00 − 5.00
U.Price-%price: at the percentage of 95%, as × . Assume that PLU10 is weight PLU with
100.00
U.Price $2.00/kg and tare 0.100kg.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】 【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Input discount data 【5】【00】 0.100 -0.100 5.00 0.00
Discount in percentage 【±%】 0.100 -0.100 1.90 0.00 〖Discount〗on.
N o t e 1 Default percentage discount is subtraction discount( Spec113=0) , if need to change the default
discount to additive, change Spec113=1
Example 4-17 Enterinterface and execute ±%price

Unit price+%price,charge 10% more.Assume that PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg.
Display
Operations KeysWeight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】
【0】
【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
without any number before
Enter ±%price
【±%】 Sub-P - 0.00 【±%】
interface
Sub-P means it is -%

26
Amend to +% 【±%】 Add-P 0.00
Input 10% 【1】【0】【00】 Add-P 10.00
Execute +%price 【Confirm】 0.100 -0.100 2.20 0.00 〖Discount〗on.
N o t e 1 Press【±%】repeatedly to amend the operation symbol to ’+’ or’-’.
Example 4-18 Directly execute default ±%price(Spec114)

Unit price+%price( Spec113=1) , charge additional 20%( Spec114=20) . Assume that PLU10 is weight PLU with
U.Price $2.00/kg and tare 0.100kg.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】
【0】 【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
without any number before
Execute default
【±%】 0.100 -0.100 2.40 0.00 【±%】
±%price
〖Discount〗on.
N o t e 1 When execute default ±%price, the +/- are decided by Spec113, default price is decided by
Spec114
4.3.4 Auto Discount
When goods are working on auto discount, the price of activated PLU would change in real-time according
to the settings and system would shield any actions of manual change on the price.
Assume PLU20 is at the U.Price $10.00/kg. U.Price goes to $9.00/kg when sale weight is more than 1kg and
U.Price goes to $8.00/kg when sale weight is more than 2kg. The change of U.Price of this PLU is shown below:
Example 4-19 Auto Discount
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU20 【2】 【0】
【PLU】0.000 0.000 10.00 0.00 〖U.Price〗,〖Single〗on.
Put weight 1.5kg 0.000 1.500 9.00 13.50 〖Discount〗on.
Add weight 1kg 0.000 2.500 8.00 20.00 〖Discount〗on.
Take off all weight and
0.000 0.500 10.00 5.00 〖Discount〗off.
put on weight 0.5kg.
N o t e 1 All details about the auto discount setting of PLU, please read definitions of auto discount settings in
List of Programme Interface on page 37 and Spec115 carefully. Suggest users edit the content on PC.
4.3.5 Unit Conversion of Temporary U.Price
Example 4-20 Unit Conversion of Temporary U.Price
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】
【0】
【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.

27
Input a Temporary
U.Price with the unit 【1】【8】【0】 0.100 -0.100 1.80 0.00
of 500g
Unit conversion 【T-Sale】 0.100 -0.100 3.60 0.00
N o t e 1 Spec210 is 7 (500g), and kg is the measure unit of the scale.
N o t e 2 Spec073 is 1: Put 【T-Sale】 into use of 【Unit Conversion】.

4.4 Setting and Lock of Tare


4.4.1 Weight Tare
Example 4-21 Weight Tare
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Put on tare object 0.000 0.050 0.00 0.00
Tare 【Tare】 0.050 0.000 0.00 0.00
Take off tare object 0.050 -0.050 0.00 0.00
Cancel tare 【Tare】 0.000 0.000 0.00 0.00
N o t e 1 If users need to cancel tare, current total weight should be 0 and users do not input any number.
4.4.2 Number Tare
Example 4-22 Number Tare
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Input tare 【3】【2】 0.000 0.000 0.32 0.00
tare 【Tare】 0.032 -0.032 0.00 0.00
Cancel tare 【Tare】 0.000 0.000 0.00 0.00
N o t e 1 Spec067 is 0: Number tare is forbidden
N o t e 2 Spec067 is 1: Use absolute value as tare. For example, when the tare definition is 0.001 and input is
0.32, tare is 0.032.
N o t e 3 Spec067 is 2: Use floating-point values as tare. For example, input 0.32 and after tare users would
get 0.320.
N o t e 4 When there are numbers in input window and total weight is not 0, weight tare is the priority.
4.4.3 Lock and Unlock of Tare
Example 4-23 Tare Lock and Unlock
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
Lock tare Long Press【Tare】 〖Lock Tare〗 on
Other operations
Unlock tare Long Press【Tare】 〖Lock Tare〗 off

28
N o t e 1 When you long press 【Tare】, you can hear one beep first (beep for correctness or error) . Hold
pressing for 4 seconds you will hear the beep for correctness.
N o t e 2 Once tare locked, it cannot be changed or cleared automatically. Only manual tare can change tare.
N o t e 3 Once tare locked, it cannot be unlocked unless users unlock tare manually.

4.5 Special sale mode


Except general sale mode, scale also with other 4 special sale mode: batch print model, pre-packing mode,
lock PLU mode, auto print mode
4.5.1 Enter and Exit of Special sale Mode
Example 4-24 Single key select of sale mode
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』
Enter Auto Mode 【Auto Mode】
Exit Auto Mode 【Auto Mode】
Enter prepack mode 【Prepack Mode】
Exit prepack mode 【Prepack Mode】
Enter auto print mode 【Auto print】
Exit auto print mode 【Auto print】
N o t e 1 【Auto Mode】key related mode are decided by Spec78
N o t e 2 Only for super market version scale with the 【Prepack Mode】【Auto print】and【lock PLU】key
N o t e 3 Under one special mode, press special mode key will exit present mode and back to general sale
mode
Example 4-25 Interface select sale mode
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』
【0】: General mode
【1】: Batch print mode
Enter Mode select Long press
Mode 0 Normal 【2】: Prepack mode
interface 【Auto Mode】
【3】: Lock PLU mode
【4】: Auto print mode
Can use【←】 【→】 【COnfirm】
Select auto print mode 【4】
to select mode
『Auto print mode』
N o t e 1 Menu of sale mode selection enable by Spec79
4.5.2 Sale under batch print mode
Example 4-26 Batch Print mode

Batch print mode. Assume PLU11 is weight PLU with U.Price $2.00/kg and tare 0.100kg.

29
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Long press
Enter mode select Mode 0 Normal
【Auto Mode】
Enter batch print mode 【1】 0.000 0.000 0.00 0.00 〖Auto Mode〗on
Transfer PLU11 【1】 【1】 【PLU】 5.00 5.00 〖U.Price〗,〖Single〗on.
Input quantity 【×】【5】 5 5.00 25.00 If number is 1, omit this step
Confirm sale object 【Print】 Input Count 0
Input the number of
【1】【0】 Input Count 10
print copies
Confirm the number 【Confirm】
Press 【Cancel】 to exit print in
Print 10 copies
midway.
Print ends 5 5.00 5.00
Exit quantity input 5.00 25.00
Exit PLU 0.000 0.000 0.00 0.00 0.000 〖Sum〗 on.
Exit Auto Mode 0.000 0.000 0.00 0.00 0.000 〖Auto Mode〗off.
N o t e 1 Under Batch print mode, user can accumulate, after accumulate , press【Print】select the print times
4.5.3 Sale under prepack mode (only for weight PLU)
Example 4-27 Prepack mode(only for weight PLU)

Prepack mode for weight PLU. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Long press
Enter mode select Mode 0 Normal
【Auto Mode】
Enter prepack mode 【1】 0.000 0.000 0.00 0.00 〖Auto Mode〗,〖lock PLU〗on
Transfer PLU10 【1】 【0】 【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Put goods PLU10 on 0.100 0.900 2.00 1.80
After weight is stable. 0.100 0.900 0.00 1.80 Print automatically.
Take goods PLU10 off 0.100 -0.100 0.00 0.00
Put goods PLU10 on 0.100 1.900 2.00 3.80
After weight is stable. 0.100 1.900 0.00 0.00 Print automatically.
Take goods PLU10 off 0.100 -0.100 0.00 0.00
……….
Exit PLU 【Cancel】 〖Sum〗 on.
Exit Auto Mode 【Auto Mode】 〖Auto Mode〗〖
, lock PLU〗off.
N o t e 1 Pre-packing enable if Spec078 is set to 2.
4.5.4 Sale under Lock PLU mode
Under lock PLU mode, cargo cannot be accumulated and after finish the sale, will not exit the present PLU
automatically.

30
4.5.5 Auto print mode (only for weight PLU)
Under auto mode, when the weight is stable, print automatically.

4.6 Operations of Sale Buffers


4.6.1 Switch of Sale Buffers
Example 4-28 Switch of Sale Buffers
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 〖Sale〗, 〖Sum〗on.
0.000 0.000 0.00 0.00
Default buffer V1 〖V1〗 glittering.
Transfer PLU10 【1】
【0】 【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗 on.
Put goods PLU10 on 0.100 0.900 2.00 1.80
Confirm a goods 【Confirm】 0.000 1.000 0.00 1.80 〖Sum〗 on.
Service other customers,
for current customer ……
delay checking out
〖V1〗on: means that there is
sale data in the buffer.
Switch buffer V2 【V2】 0.000 0.000 0.00 0.00
〖V2〗glittering: means that
buffer『V2』is working
Execute sales. Users
can switch to V3, V4 ……
according to demands.
Continue sale buffered in
……
V1 for customer return.
Switch buffer V1 【V1】 0.000 1.000 0.00 1.80 〖V1〗 glittering.
Transfer PLU11 【1】
【1】 【PLU】 5.00 5.00 〖U.Price〗,〖Single〗 on.
Input PLU11 amount 【×】【5】 5 5.00 25.00
Confirm a goods 【Confirm】 0.000 0.000 0.00 26.80 〖Sum〗 on.
If payment is equal to
0.000 0.000 0.00 26.80
total, don’t input.
〖Change〗, 〖Sum〗 on.
Print 【Print】 0.00 26.80
Execute print.
Finished sales buffered
in V2~V4.
4.6.2 Cancel Sale Data in Sale Buffers
Example 4-29 Clear All Data in Current Sale Buffers
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗 on.
Put goods PLU10 on 0.100 0.900 2.00 1.80
Confirm a goods 【Confirm】 0.000 1.000 0.00 1.80 〖Sum〗 on.

31
Take goods PLU10 off 0.000 0.000 0.00 1.80
Transfer PLU11 【1】 【1】【PLU】 5.00 5.00 〖U.Price〗,〖Single〗 on.
Input PLU11 amount 【×】【5】 5 5.00 25.00
Confirm a goods 【Confirm】 0.000 0.000 0.00 26.80 〖Sum〗 on.
02.00 6 26.80
Enter cancel interface 【Amend】 Piece Total 〖Sum〗 on.
Total
Number Price
Clear all data 【Confirm】 0.000 0.000 0.00 0.00 〖Sum〗 on.
Example 4-30 Clear One Goods in Current Sale Buffer
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】 【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗 on.
Put goods PLU10 on 0.100 0.900 2.00 1.80
Confirm a goods 【Confirm】 0.000 1.000 0.00 1.80 〖Sum〗 on.
Take goods PLU10 off 0.000 0.000 0.00 1.80
Transfer PLU11 【1】 【1】【PLU】 5.00 5.00 〖U.Price〗,〖Single〗 on.
Input PLU11 amount 【×】【5】 5 5.00 25.00
Confirm a goods 【Confirm】 0.000 0.000 0.00 26.80 〖Sum〗 on.
02.00 6 26.80
Enter amend interface 【Amend】 Piece Total 〖Sum〗 on.
Total
Number Price
02.01 0.900 10 1.80
Use 【←】【→】to
【→】 Goods PLU Single 〖Single〗on.
select goods Amount
1 Number Price
Confirm amendment 【Confirm】 0.000 0.000 0.00 25.00 〖Sum〗 on.
N o t e 1 In amend window: the window of tare is in the form of xx xx. The first part shows accumulative
times; the latter part is the object to be amended. 00 is total and 01~31 are accumulative number.
N o t e 2 If users amend the total, the whole deal is cleared.
N o t e 3 If users amend xx goods, information of xx goods is cleared. And if there was a T.Price discount,
T.Price discount information is cleared. T.Price will be calculated based on U.Price (or discounted
U.Price) and amount of sold goods.
N o t e 4 If T.Price is selected, the window of 『Weight/Count』 will display piece number of sold goods. The
definition of piece number is: 5 count goods add 5 and each weight goods add 1.

4.7 Salesman and Waiter


4.7.1 Personnel Information
Please refer to Salesman Programme in page 55. Salesman and waiter use the same personnel sheet.
4.7.2 Salesman Function
Salesman Function is disabled as default. User can enable it at Spec135. Normally, Set Spec135=2 or 4.
Only non-zero password Personnel can login as salesman when Spec135=4 or 5.
User need to input salesman’s number and password in the login menu before get into sale menu when

32
salesman function is enable.
4.7.3 Waiter Function
Do not enable in the common version, and do not have corresponding key.

4.8 Inquiry of Sale Records and Markers of Returns of Goods


Mark the tenth item in the sale record as return of goods.
Example 4-31 Inquiry of Sale Records and Markers of Returns of Goods
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
2 5 11 25.00 If there is data in current
PLU buffer, system would first enter
Note 2 Amount Price
Number buffer interface, long press will
Long Press
Enter『Sale Records』 enter current interface,. If there
【Amend】
is no sale records, it will not
enter this interface
Information Page 1
Other information of Sale time of records.
【↓】 2008 05 24 09 08 59 W-6
record items Information Page 2
Other information of 15 Note 1
【↓】 Note 5 Note 3 15
record items Note 4 Information Page 3
Other information of
【↓】 02.02 5 11 25.00
record items
See previous record 【←】 02.01 0.900 10 1.80
【×】 Input 1-1 0
Switch to the appointed
See record 10 【1】【0】
01.01 1.000 12 4.00 number record.
【Confirm】
Other information of
【↓】 2008 05 24 08 01 39 W-6
record items
Other information of 10 here is the appointed
【↓】 15 10
record items number.
Other information of
【↓】 01.01 1.000 12 4.00
record items
【F-Prog】+
Sign as a return goods 01.01 1.000 12 4.00
【Amend】
Return to sale mode 【Cancel】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
N o t e 1 The record are divided into deal head record and deal detailed record, deal head record include deal
data of FID , SID, deal discount sum,etc; deal detailed record include the detailed cargo deal
information
N o t e 2 When display deal head record, here display ‘----’, when display deal detailed record, here display
this goods are which number cargo
N o t e 3 When display deal head record, here display this deal’s SID (code ID, refer to Spec140), when
display deal detailed record, here is blank

33
N o t e 4 The number shown in the window of change / U.Price is the amount of sale record stored in the scale.
When the number is close to 8000, the scale would delete the earlist records automaticlly. And
Single/Total Price window shows the sequence number of this record in all the records
N o t e 5 If present record are marked as goods return, the window will display“-RT-”.

4.9 Manual Weight


4.9.1 Manual Sale of Manual Weight Entry
Example 4-32 Manual Sale of Manual Weight Entry

Sell 1 kg PLU10 goods. Assume PLU10 is a weight PLU with U.Price is $2.00/kg and tare is 0.100kg.
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Transfer PLU10 【1】【0】【PLU】0.100 -0.100 2.00 0.00 〖U.Price〗,〖Single〗on.
Manual weight entry 【Manual Weight】 Man Weight 0.000
Weight data 【1】【0】【00】 Man Weight 1.000
Put on a weight 【Confirm】 ---- 1.000 2.00 2.00 【Manual Weight】on
Print 【Print】 0.000 0.000 0.00 0.00 Execute print.
N o t e 1 Manual weight entry need Spec077 set to non-zero (1, 2 or 3 are all ok).
N o t e 2 Manual weight entry can be executed only if weight keeps at zero and stable.
N o t e 3 In manual weight sale process, tare function is forbidden, 〖Manual Weight〗 on, and “ManWT” is
printed before weight data.

4.10 Bar code printing and scanning


4.10.1 Exterior bar code
Exterior bar code is EAN/UPC barcode normally, which is defined by the standards organisation GS1.
If user look for commodity by exterior bar code, user need to input the commodity’s bar code to PLU’s
Index Barcode, after the scanner scan the bar code, it will search and transfer the same index PLU auotmatically.
When user edit the PLU on the scale, scan the exterior bar code during the PLU numbwe step, it will transfer
the PLU related to the exterior bar code; if scans the exterior bar code in other step, it will consider this bar code
as present PLU’s index barcode.
4.10.2 Interior bar code
Interior bar code is user appointed barcode format and only used in small are, generally used for
communication between barcode scale and cash machine like cash register scale or cash register machine.
In the rule of EAN-UCC, define the prefix code 20-29 as shop inside use to avoid the repeatance with EAN
code. So, if user uses both exterior and interior bar code, then interior bar code ‘s prefix must inside 20-29.
To meet the different request, the interior bar code’s format can be defined by user, but the print device
(barcode label scale) and scan device (cash register scale or cash register) must with the same format, then the
interior bad coe can be exactly recognised

34
5 Programme Operations

5.1 Please Read this Part First


For ordinary users, they can use 3 kinds of Fast Progs in Fast Prog in chaper 3 to handle most applications.
There are detailed programme operations of the scale in this chapter, as well as examples for users. But some
parts of programme content are very complicated such as print format edit and barcode format edit. Devisers
suggest users use company offered software when users are in need of these functions. The company software
offers users a convenient interface to edit all the working parameters and sale data of the scale. The setting data
can be downloaded from Ethernet (real-time download), or transferred in the form of files by USB flash disk
(Users edit the data on PC and store data in USB flash disk, then download data to scale from USB flash disk.).
Devisers are convinced that it’s easy to learn to use the company software. As long as users own basic
computer operation knewledge and learn with user menual of this software (User menual would be
installed with the software), users can operate the software in a very short time. If users cannot use
computer and are still in need of complicated programme operations, users can write down the demands
and send to us.
If computers cannot be used in users’ circumstances, and users are indeed in need of functions of this part,
please read content in this chapter carefully. In consideration of too much content, detailed example instructions of
all operations will not be provided in some chapters. But all the functions are instructed in words and processes
are arranged in sequence of steps. Users should read Tree-shaped Design of Edit Steps and Frequently-used Keys
in Prog Interfaces first carefully. Then do programme operations according to instructions in List of Programme
Interface and corresponding chapters on the basis of fully understanding of these two parts.

5.2 Basic Operations in Programme Interface


5.2.1 Tree-shaped Design of Edit Steps
Prog P11 Time Press 【Prog】 first enter P1;
Menu Scale Paramete P12 Spec Use【←】 and 【→】to select one of P1
P1 to P5. Use 【Confirm】 to select
(TM-Set) P13 Sring
P14 PLU Shortcut corresponding programme operations;
Or press【1】~【5】directly to enter P1~
P21 Dept.
P5;
P22 Class
Then use the way to go to Next.
P23 PLU
Sale Data
P2 P24 Unit The operations are a little different in
(DT-Set)
P25 Barcode various programme operations. But they
P26 Print format are almost designed into tree-shaped.
P27 Salesman Instructions and examples about each part
P31 PLU Prog steps would be in following chapters.
Data Assistant
P3 P32 PLU F-Prog steps
(DT-Ass)
P33 Delete Sale data .
P4 Communications P41 USB flash disk Note: Communication ways of P4 depend
(Commu) on the hardware of the scale. And basic
P42 Ethernet
h d l h P41

35
P43 RS232 hardware only has P41.
P44 USB slave
Hardware Assistant P51 Set the passwords
P5
(HWAss) P52 Factory default

P1.--
Fast Prog
TM-Set

Time Spec String ScPLU

P2.--
DT-Set

Dept. Class PLU

Unit Bcode Label Sales

Prog- P3.--
Menu DT-Ass

SK-PLU SKFPLU Delete

P4.--
Commu

U-Disk Ethnet RS232 USlave

P5.--
HW-Ass

Set-PW TMS-DF

Note: Hardware information must be operated in this machine.


Picture 5-1 Sketch map of tree-shaped design of edit interface

5.2.2 Frequently-used Keys in Prog Interfaces


【Amend】: Save the amended content and go back to previous interface. If operation is in DTSet, go

36
back to step 0 after save and wait for new number to be input to amend.
【Cancel】: Don’t save and go back to previous interface.
【Confirm】: Get into next step to edit. Such as enter P3 by pressing 【Confirm】 when operation is in
P31. And press 【Confirm】 to enter certain edit interface when operation is in text edit or in edit
interface of print format. Then press 【Amend】 to save and exit, or press 【Cancel】 to exit without
saving.
【←】、【→】: Steps selection. Such as press 【←】 and【→】 to select steps P21~ P27
【↑】、
【↓】: Press 【↑】
【↓】 to select previous or next valid data when amending data in programme.
And its function is the same as 【←】【→】 in some interfaces when no data is to be amended.
【0】~【9】、00: Input corresponding numbers.
【back】: Delete the last digit number.
【×】: For so many steps to select in processes of Spec and DTSet edit operations in TMSet, users can
use 【×】 to select step to edit. There would be a hint for you to input the step number you want to
select after you press【×】. Please input the number and press 【Confirm】.
5.2.3 List of Programme Interface
Menus Menu Prompt Instructions Remarks State
P1 TMSet BarCode Scale Setting
P11 TMSet Time
P12 TMSet Spec Spec Parameters setting
P12 SP.000 Spec 000
Spec 000~249, see details in chapter 7.2
…… …… …… ……
Definitions of Spec data parameters
P12 SP.249 Spec 249
P13 TMSet String Text setting
P13 ST.000 ShopN String 0: Store name
P13 ST.001 ScaleN String 1: Device name
P13 ST.002 MnyPre String 2: Prefix of Money Unit
P13 ST.003 MnySuf String 3: Suffix of Money Unit
P14 TMSet scPLU PLU shortcut key setting
P2 DTSet Scale Data setting
P21 DTSet Dept Dept. setting
P21 DPT.00 NoSet Dept.0: Number Available dept edit number: 10~99.
P21 DPT.01 Name Dept.1: Name
P22 DTSet Class Class
P22 CLS.00 NoSet Class 0: Number Available class edit number 10~99
P22 CLS.01 Name Class 1: Name
P22 CLS.00 Dept Class 2: Dept. that it belong to
P23 DTSet PLU PLU
P23 PLU.00 NoSet PLU 0: Number Available PLU edit number 1~9999999.
P23 PLU.01 ICode PLU 1: Item Code Be printed with barcodes.
P23 PLU.02 Index PLU 2: Index for exterior barcode

37
Menus Menu Prompt Instructions Remarks State
1 is default weight unit;
2 is default weight unit;
3 is kg weight unit;
4 is g weight unit;
P23 PLU.03 Unit PLU 3: Unit
5 is ton weight unit;
6 is pound weight unit;
7 is 500g weight unit;
8 is 100g weight unit.
P23 PLU.04 Price PLU 4: U.Price
P23 PLU.05 Cost PLU 5: Cost
P23 PLU.06 Tare PLU 6: Tare
P23 PLU.07 Lab-1 PLU 7: Print format number of 1st bill
P23 PLU.08 BarT1 PLU 8: Barcode number of 1st bill
P23 PLU.09 BarF1 PLU 9: Barcode flag of bill 1st bill
P23 PLU.10 Lab-2 PLU 10: Print format number of 2nd bill
P23 PLU.11 BarT2 PLU 11: Barcode number of 2nd bill
P23 PLU.12 BarF2 PLU 12: Barcode flag of 2nd bill
P23 PLU.13 Class PLU 13: class that it belongs to
P23 PLU.14 Name PLU 14: Goods name
P23 PLU.15 Des-1 PLU 15: Goods postil 1
P23 PLU.16 Des-2 PLU 16: Goods postil2
P23 PLU.17 Des-3 PLU 17: Goods postil3
P23 PLU.18 Des-4 PLU 18: Goods postil4
P23 PLU.19 Des-5 PLU 19: Goods postil5
P23 PLU.20 Des-6 PLU 20: Goods postil6
P23 PLU.21 Des-7 PLU 21: Goods postil7
P23 PLU.22 PS-SD PLU 22: Sale date print 0: not print, 1: print.
0: not print, 1: print at appointed time,
P23 PLU.23 PS-ST PLU 23: Sale time print
2: print printing time.
P23 PLU.24 PS-PD PLU 24: Packing date print 0: not print, 1: print.
0: not print, 1: print at appointed time,
P23 PLU.25 PS-PT PLU 25: Packing time print
2: print printing time.
P23 PLU.26 PS-UD PLU 26: Shelf date print 0: not print, 1: print.
P23 PLU.27 PC-SD PLU 27: Sale days data Number of days after current day.
P23 PLU.28 PC-ST PLU 28: Sale time data Appointed time for print.
P23 PLU.29 PC-PD PLU 29: Packing days data Number of days after current day.
P23 PLU.30 PC-PT PLU 30: Packing time data Appointed time for print.
P23 PLU.31 PC-UD PLU 31: Shelf days data Number of days after current day.
0: use system setting; 1: no lower limit;
P23 PLU.32 DF-D PLU 32: Manual discount lower limit 2: Take original cost as lower limit;
3: Take PLU.34 as lower limit.
0: use system setting; 1: no upper limit;
P23 PLU.33 DF-U PLU 33: Manual discount upper limit 2: Take original U.Price as upper limit;
3: Take PLU.35 as upper limit.
PLU 34: Value of manual discount lower
P23 PLU.34 DF-DN Activated when DF_D=3.
limit
PLU 35: Value of manual discount upper
P23 PLU.35 DF-UN Activated when DF_D=3.
limit

38
Menus Menu Prompt Instructions Remarks State
0: not activate; 1: discount on count;
P23 PLU.36 DA-S0 PLU 36: Customize 0 of auto disount
2: discount on periods of time.
Sunday: 1, Monday: 2, Tuesday: 4
Wednesday: 8, Thursday: 16, Friday: 32
Saturday: 64. When this customization discount
needs to be activated at some certain days, input
P23 PLU.37 DA-W0 PLU 37: Activation day of the customize
add-up number of these days here. To input 127
means that the discount is activated all the days.
To input 1+64=65 if the discount is only
activated at Saturday or Sunday.
Execute this discount way in this customization
PLU 38: The Lower limit of activation period.
P23 PLU.38 DA-D0 customization activation period Input weight/count according to the unit of PLU
Start at this point (include this point) when discount on amount. When inputing
count, 10 goods needs to input 10.000 or move
decimal (long press 【Shift】 or 【F-Prog】+
【Shift】) to input 10. Avoid inputing 0.010 for
PLU 39: The upper limit of
10 pcs.
P23 PLU.39 DA-U0 customization activation period
When discount on time, the format of input
End at this point (not include this point)
time is HHMM. If the time is 20: 30, users need
to move decimal to input 2030.
If number is positive, discount number would
replace U.Price. If number is minus, new
P23 PLU.40 DA-N0 PLU 40: Discount Price of customize U.Price is the price that subtracts the input
number from former U.Price. But minus values
cannot be input in the scale.
P23 PLU.41 DA-S1 PLU 41: Customize 1 of auto disount
P23 PLU.42 DA-W1 PLU 42: Activation day of the customize
PLU 43: The Lower limit of It’s the same as last customize discount.
P23 PLU.43 DA-D1
customization activation period After the edit of last customize discount it
PLU 44: The upper limit of can be edited.
P23 PLU.44 DA-U1
customization activation period
P23 PLU.45 DA-N1 PLU 45: Discount Price of customize
P23 PLU.46 DA-S2 PLU 46: Customize 2 of auto disount
P23 PLU.47 DA-W2 PLU 47: Activation day of the customize
PLU 48: The Lower limit of It’s the same as last customize discount.
P23 PLU.48 DA-D2
customization activation period After the edit of last customize discount it
PLU 49: The upper limit of can be edited.
P23 PLU.49 DA-U2
customization activation period
P23 PLU.50 DA-N2 PLU 50: Discount Price of customize
P23 PLU.51 DA-S3 PLU 51: Customize 3 of auto disount
P23 PLU.52 DA-W3 PLU 52: Activation day of the customize
PLU 53: The Lower limit of It’s the same as last customize discount.
P23 PLU.53 DA-D3
customization activation period After the edit of last customize discount it
PLU 54: The upper limit of can be edited.
P23 PLU.54 DA-U3
customization activation period
P23 PLU.55 DA-N3 PLU 55: Discount Price of customize

39
Menus Menu Prompt Instructions Remarks State
0: excute tax rate according to Spec 116,117
1: tax free price mode
P23 PLU56 Tax-S PLU56: tax rate sort 2:: tax free price mode, input unit price is price
duty paid
3.with tax price mode
P23 PLU.57 Tax-D PLU57: tax rate percentage 0.01% tax rate,17% input 1700
P24 DTSet Unit Unit
P24 UNT.00 NoSet Unit 0: Number
P24 UNT.01 Name Unit 1: Name
Unit 4: Measure Mode(just open 1 is default weight unit,
P24 UNT.04 PUnit Not Open
weighing mode) 2 is default count unit,
In weighing mode, means how much gram as
one packing
P24 UNT.05 Pack Unit 5: Packing Not Open
In counting mode, means how many pcs as one
packing
P25 DTSet Bcode Barcode
Edited number of barcode when leaving factory
P25 BAR.00 NoSet Barcode 0: Number
are 1~9. Available barcode edit number 10~99.
P25 BAR.01 Name Barcode 1: Name
P25 BAR.02 Type Barcode 2: Type
P25 BAR.03 Check Barcode 3: Checkout
P25 BAR.04 NCon1 Barcode 4: Constant number 1
P25 BAR.05 NCon2 Barcode 5: Constant number 2
Please pay attention that edit content should
P25 BAR.05 Des Barcode 6: Data format description accord with certain format: refer to chapter of
barcode.
P26 DTSet PSets Print format
Edited label in factory: 1~9;
P26 PST.00 NoSet Print format 0: Number
Available label edit number 10~29.
P26 PST.01 Name Print format 1: Name
P26 PST.02 Sort Print format 2: Using sort
P26 PST.03 Lng-X Print format 3: Width
P26 PST.04 Lng-Y Print format 4: Height
P26 PST.05 Txt01 Print format 5: Text 1
P26 PST.06 Txt02 Print format 6: Text 2
P26 PST.07 Txt03 Print format 7: Text 3
P26 PST.08 Txt04 Print format 8: Text 4
P26 PST.09 Txt05 Print format 9: Text 5
P26 PST.10 Txt06 Print format 10: Text 6
P26 PST.11 Txt07 Print format 11: Text 7
P26 PST.12 Txt08 Print format 12: Text 8
P26 PST.13 Txt09 Print format 13: Text 9
P26 PST.14 Txt10 Print format 14: Text 10
P26 PST.15 Txt11 Print format 15: Text 11
P26 PST.16 Txt12 Print format 16: Text 12
P26 PST.17 Txt13 Print format 17: Text 13
P26 PST.18 Txt14 Print format 18: Text 14

40
Menus Menu Prompt Instructions Remarks State
P26 PST.19 Txt15 Print format 19: Text 15
P26 PST.20 Txt16 Print format 20: Text 16
Suggest new font mode after V2.03 but still
P26 PST.21 FontM Print format 21: Font mode
support old font
P26 PST.22 LAS Print format 22: Print Item
P26 LAS.00 NoSet Print item 0: Item number Available print item edit number 0~99.
P26 LAS.01 Flag1 Print item 1: Symbol 1
P26 LAS.02 Flag2 Print item 2: Symbol 2
P26 LAS.03 Flag3 Print item 3: Symbol 3
P26 LAS.04 Print Print item 4: Print state
P26 LAS.05 Angel Print item 5: Print angle
P26 LAS.06 Grid Print item 6: Type of snap to grid
P26 LAS.07 CFont Print item 7: Print font
P26 LAS.08 S-X Print item 8: Start position X
P26 LAS.09 S-Y Print item 9: Start position Y
P26 LAS.10 L-X Print item 10: Area length X
P26 LAS.11 L-Y Print item 11: Area length Y
P27 DTSet Sales Salesman Available salesman edit number 10~99
P27 SAL.00 NoSet Salesman 0: Number
P27 SAL.01 Name Salesman 1: Salesman name
P27 SAL.02 Pass Salesman 1: Salesman password
P3 DTAss Data assistant
P31 DTAss Sk-PLU PLU Prog skip step setting
P31 PLU.00 NoSet PLU 0: Number Choice 0: Prog means to be programme,
P31 PLU.01 ICode PLU 1: Item Code Choice 1: Skip means skiped in programme
P31 PLU.02 Index PLU 2: Index for exterior barcode
P31 PLU.03 Unit PLU 3: Unit
P31 PLU.04 Price PLU 4: U.Price
P31 PLU.05 Cost PLU 5: Cost
P31 PLU.06 Tare PLU 6: Tare
P31 PLU.07 PST-1 PLU 7: Print format number of 1st bill
P31 PLU.08 BarT1 PLU 8: Barcode number of 1st bill
P31 PLU.09 BarF1 PLU 9: Barcode flag of bill 1st bill
P31 PLU.10 PST-2 PLU 10: Print format number of 2nd bill
P31 PLU.11 BarT2 PLU 11: Barcode number of 2nd bill
P31 PLU.12 BarF2 PLU 12: Barcode flag of 2nd bill
P31 PLU.13 Class PLU 13: class that it belongs to
P31 PLU.14 Name PLU 14: Goods name
P31 PLU.15 Des-1 PLU 15: Goods postil 1
P31 PLU.16 Des-2 PLU 16: Goods postil2
P31 PLU.17 Des-3 PLU 17: Goods postil3
P31 PLU.18 Des-4 PLU 18: Goods postil4
P31 PLU.19 Des-5 PLU 19: Goods postil5
P31 PLU.20 Des-6 PLU 20: Goods postil6
P31 PLU.21 Des-7 PLU 21: Goods postil7
PLU 22: Sale date print
P31 PLU.22 PS-SD
Attached: PLU.27: Sale date data

41
Menus Menu Prompt Instructions Remarks State
PLU 23: Sale time print
P31 PLU.23 PS-ST
Attached: PLU.28: Sale time data
PLU 24: Packing date print
P31 PLU.24 PS-PD
Attached: PLU.29: Packing date print
PLU 25: Packing time print
P31 PLU.25 PS-PT
Attached: PLU.30: Packing time data
PLU 26: Shelf date print
P31 PLU.26 PS-UD
Attached: PLU.31: Shelf date data
PLU 32: Manual discount upperlimit
P31 PLU.32 DF-U
Attached: PLU.34
PLU 33: Manual discount lower limit
P31 PLU.33 DF-D
Attached: PLU.35
PLU 36: Customize 0 of auto discount
P31 PLU.36 DA-S0
Attached: PLU.37-PLU.55
P32 DTAss SkFPLU PLU F-Prog skip step setting
The same as P31
P33 DTAss Delete Delete data of the scale Validate code is needed to enter: 9958.
P33 DEL.01 Dept Delete1: Dept. When entering to delete, system would request
P33 DEL.02 Class Delete2: Class to input 2 numbers which mean the start
P33 DEL.03 PLU Delete3: PLU number and the end number of the data to
P33 DEL.04 Unit Delete4: Unit delete. If the end number is 0, only data of the
P33 DEL.05 BCode Delete5: Barcode start number would be deleted. If the number is
P33 DEL.06 PSets Delete6: Print format not 0 and it’s less than start number, no data
P33 DEL.07 Sales Delete7: Salesman would be deleted.
P4 Commu Communication setting
P41 Commu U-Disk Load and save of data in USB flash disk
P42 Commu Ethnet Not real-time Download from Ethernet
P43 Commu RS-232 RS232communication
P44 Commu USlave USB slave communication Not Open
P44 Commu PTR Ethernet printer communication
Admin password is required to enter
P5 HWAss Hardware assistant setting
administrator’s password: 200806
P51 HWAss Set-PW Hardware: setting password
P511 HWAss Set-PW Admin : Admin password
P512 HWAss Set-PW Sale : Sale password
Input same passwords 2 times to complete
P513 HWAss Set-PW Prog : Prog password
amendment of password.
P514 HWAss Set-PW Account : Account password
P515 HWAss Set-PW Drawer : Drawer password
P52 HWAss TMS-DFHardware: Recover factory default
P521 HWAss TMS-DFFac-Set : Scale parameter(P1x)
Base-DT : Default working data(P2x
P522 HWAss TMS-DF The interface that requires to input validate
default)
code would be shown before default setting.
P523 HWAss TMS-DFEraseDT : All working data(P2x)
Input 9958 to finish setting.
Fac-All : All parameters and
P524 HWAss TMS-DF
data(P2x)

42
5.3 The Edit of All Parts in TMSet
5.3.1 Time Programme
Example 5-1 Time Programme
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗,〖Sum〗on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter TMSet 【1】 P11 TMSet Time
Enter time 2008 05 19 20 21 51 W-1 W-0 means Sunday, W-1
【1】
programme Year Month Day Hour Minute Second Week means Monday, and the like.
Cursor indicates current
Input current time editing object. And using
……
by number key 【←】 【→】 could move the
position of cursor.
Save time 【Amend】 P11 TMSet Time Save to the scale.
Return to sale 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
5.3.2 Programme of Spec Parameters
Example 5-2 Programme of Spec parameters
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗on.
Enter TMSet 【1】 P11 TMSet Time
P12 SP.000 1 1
Enter Spec 【2】
Spec No. Origin Set Current Set
Change to 2 【2】 P12 SP.000 1 2
Using【 】 【 】 can only
Enter Spec002 【 】【 】 P12 SP.002 0 0 get to amend items in Spec
amend level 0.
Change to 77 【7】【7】 P12 SP.002 0 77
Choose steps directly 【×】 Input 1-1 0
The input number of step
must be in Spec amend
Input step 40 【4】【0】 Input 1-1 40
level 0 or 1. If not, the step
cannot be reached.
Confirm step 【Confirm】 P12 SP.040 0 0
Change to 99 【9】【9】 P12 SP.040 0 99
Save and exit 【Amend】 P12 TMSet Spec
Return to sale 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
N o t e 1 The way it programmes is the same as the way in Fast-Prog of Spec Parameters in page 19, except
the way it enters programme page.
N o t e 2 Please refer to Definitions of Spec data parameters in page 73 for definitions of all items of Spec

43
data parameters.
5.3.3 Programme of Text Parameters
Example 5-3 Programme of Text Parameters
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗on.
Enter TMSet 【1】 P11 TMSet Time
P13 ST.000 ShopN Push-OK
Enter String 【3】 ST.000 is store name.
String No. String Info
Switch to device name 【→】 P13 ST.001 ScaleN Push-OK ST.001 is device name.
Switch to store name 【←】 P13 ST.000 ShopN Push-OK
Enter editing 【Confirm】 EN-1 0
In view of have original
text, Suggesting users
press 【 End 】 before
editing to clear former
Clear original text 【End】 EN-1 0
text.. If modify on
original literal, use【 】
【 】to move cursor to
target position
Switch to EN-2 【Switch】 EN-2 0 0
Save editing text 【Amend】 P13 PLU.14 Name OK-Edit Save to the scale.
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 Please refer to 7.3 Definitions of String data paremeters for definitions of each text parameter.
5.3.4 Programme of PLU Shortcut Keys
Example 5-4 Programme of PLU Shortcut Keys
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗on.
Enter TMSet 【1】 P11 TMSet Time
Enter PLU shortcut key 【4】 P14 scPLU ------ -------
Set SC1 【SC1】 P14 scPLU 0-01 0
Input PLU number 【1】【0】 P14 scPLU 0-01 10
Confirm input 【Confirm】 P14 scPLU ------ ------- Save to temporary buffer.
Set SC2 【SC2】 P14 scPLU 0-02 0
Input PLU number 【1】【1】 P14 scPLU 0-02 11
Confirm input 【Confirm】 P14 scPLU ------ ------- Save to temporary buffer.
Set Shift+SC1 【Shift】
【SC1】P14 scPLU 1-01 0
Input PLU number 【1】【0】【0】 P14 scPLU 1-01 100

44
Save to temporary buffer.
The last confirm can be
Confirm input 【Confirm】 P14 scPLU ------ -------
skipped. Press 【Amend】
directly.
Save editing text 【Amend】 P14 TMSet scPLU Save to the scale.
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
N o t e 1 The way it programmes is the same as the way of Example 3-2 and Example 3-3 in page 18, except
the way it enters programme interface.
5.3.5 Programme of Fuction Shortcut Keys
Example 5-5 Programme of Fuction Shortcut Keys
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗on.
Enter TMSet 【1】 P11 TMSet Time
Enter Fuction shortcut 【5】 P15 scFuc ------ -------
Set SC1 【SC1】 P15 scFuc 0-01 0
Input Fuction number 【7】【6】 P15 scFuc 1 76 Fuction “Custom Info 1”=76
Save editing text 【Amend】 P15 TMSet scFuc Save to the scale.
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on.
N o t e 1 Please refer to 7.4 Definitions of Shortcut Function Key for details

5.4 The Edit of All Parts in DTSet


5.4.1 Department Programme
The department (Dept. for short) is the largest category in sales statistics. And it’s marked with number from 1 to
99 and the corresponding meanings are shown below:
Number Use Instructions
1 System Dept. Not edited weight Dept.
2 System Dept. Not edited count Dept.
8 System Dept. Error Dept.
9 Default Dept. Default Dept. for Class editing
10~99 User Dept. Dept. that users can edit
Example 5-6 Department Programme
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter DTSet 【2】 P21 DTSet Dept
P21 DPT.00 NoSet 0
Enter Dept. programme 【1】
Step No. Step Info Object
Enter number 10 【1】【0】 P21 DPT.00 NoSet 10
Next 【→】 P21 DPT.01 Name OK-Edit

45
Department names would
usually not be printed. And they
are always used for
Edit department name
management in PC. So editing
their names is of little meaning.
Here we skip it off.
Save editing data 【Amend】 P21 DPT.00 NoSet 0 Continue to edit other
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
5.4.2 Class Programme
Class is the second largest category in sales statistics. And it is marked with number from 1 to 99 and the
corresponding meanings are shown below:
Number Dept. Use Instructions
1 1 System Class Not edited weight Class
2 2 System Class Not edited count Class
8 8 System Class Error Class
9 9 Default Class Default Class for PLU editing
10~99 User Class Class that users can edit
Example 5-7 Class Programme
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter DTSet 【2】 P21 DTSet Dept
P22 CLS.00 NoSet 0
Enter class programme 【2】
Step No. Step Info Object
Input class number 10 【1】【0】 P22 CLS.00 NoSet 10
Next 【→】 P22 CLS.01 Name OK-Edit
Class names would usually not
be printed. And they are always
Edit class name used for management in PC. So
editing their names is of little
meaning. Here we skip it off.
Department that the class
Next 【→】 P22 CLS.02 Dept 0 belongs to. And the department
must exist.
Input department
【1】【0】 P22 CLS.02 Dept 10
number 10
Save editing class 【Amend】 P22 CLS.00 NoSet 0 Continue to edit other classes.
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
5.4.3 PLU Programme
Price-LookUp is information cell for goods sale. Serial number of PLU, as the only sign of scale store PLU, is
defined by user to correspond to actual goods. Remark number, as the number defined by users or the serial
number of actual goods, is often printed as barcode. All the serial numbers which can be edited by users are from

46
10 to 9999999. And special serial numbers are corresponding to the meanings shown below:
Internal
Number Class Use Instructions
Number
1 9999999 1 System PLU Not edited weight PLU
2 9999998 2 System PLU Not edited count PLU
3 9999997 3 System PLU Service charge PLU
10~5999 1~9999996 User PLU PLU for users to edit
Example 5-8 PLU Programme
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗,〖Sum〗on.
Enter Prog 【Prog】 P1 TMSet 〖Prog〗 on.
Enter DTSet 【2】 P21 DTSet Dept
P23 PLU.00 Not Set 0
PLU Prog 【3】 〖Prog〗on.
Step No. Step Info Object
PLU Number 【1】【0】 P23 PLU.00 Not Set 10 Number are between 1~9999999
Go to Next 【 】 P23 PLU.01 ICode 0
ICode is Item-Code, which is usually
printed as part of letters on barcode
Input print. If the number of barcodes is
90001 P23 PLU.01 ICode 90001
Item-Code default 2/5 or other custom numbers,
ICode are printed as a part of barcodes.
Please see details in chapter Barcode.
Go to Next 【 】 P23 PLU.03 Unit 0
【0】,【1】: default weight unit;
【2】: default count unit;
【3】: kg weight unit;
【4】: g weight unit;
【5】: ton weight unit;
Set as weight 【6】: lb weight unit;
【1】 P23 PLU.03 Unit 1
PLU 【7】: 500g weight unit;
【8】: 100g weight unit;
Please see details in unit chapter.
Default weight unit mean the unit used
for display. And it is suggested for
weight PLU.
Go to Next 【 】 P23 PLU.04 Price 0.00
Preset U.Price in sale. Don't have to
Set U.Price 【3】
【0】
【00】P23 PLU.04 Price 30.00 input it. Users can temporarily input it
in sale.
Go to Next 【 】 P23 PLU.05 Cost 0.00
The cost is used to calculate the profits.
Set cost 【2】
【4】
【00】P23 PLU.05 Cost 24.00
Don’t have to input it.
Go to Next 【 】 P23 PLU.06 Tare 0.000

47
When transferring PLU, it’s preset tare.
Set Tare 【5】 P23 PLU.06 Tare 0.005
Don’t have to input it.
Go to Next 【 】 P23 PLU.14 Name OK-Edit Input the names of goods.
Set name 【Confirm】 En-1 0
In consideration of there was a text, we
suggest users press 【End】 before
Clear Original
【End】 EN-1 0 editing. If editing in the original text,
Text
users could use【 】 【 】 to move the
position of cursor.
P 【Shift】
【p/P】EN-1 1 P
【o/O】【r/R】
ork EN-1 4 rk
【k/K】
- 【-】 EN-1 5 k-
Input number
【2】 En-1 6 -2
2
This 【Amend】 is to save text edit in
buffers instead of PLU. Please pay
Save edited
【Amend】 P23 PLU.14 Name OK-Edit attention: If users need save it in PLU,
text
users need to press【Amend】 again as
the step below.
Go to next 【 】 P23 PLU.26 PS-UD 0 If to print the shelf life date
0: Don't print PLU 31 invalid
Print shelf date 【1】 P23 PLU.26 PS-UD 1 1: Print. Continiune to set shelf days in
PLU.31
Go to next 【 】 P23 PLU.31 PC-UD 0 Shelf days. 0 means intraday valid,
followed like this.
Input shelf
【 】 P23 PLU.31 PC-UD 3 If all cargo for one scale use same shelf
days
days, use Spec105 & Spec106
If other steps are still to be edited, users
…… P23
can use 【 】【 】 to switch steps.
Save edited
【Amend】 P23 PLU.00 Not Set 0 PLU10 is saved.
PLU
Return to sale 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗,〖Sum〗 on
N o t e 1 Except the parts which have been instructed, meaning of the other words are listed List of
Programme Interface in page 46
N o t e 2 The way it programmes is the same as the way Fast-Prog of Example 3-1 in page 16, except the way
it enters programme page.
N o t e 3 xx is not continuous when users press【 】and【 】to select the programme content. There are two
reasons. First reason is that the content in this part is meaningless. For example, tare is not present in
count PLU programme. The second reason is that the content in that part is seldom used and has been
set as non-programme content (Skip) in P31 and P32. Users could change that setting for personel
usage and please refer to corresponding chapters for details.
5.4.4 Unit Programme
Unit is the basis of sale price. The scale has shielded parts of functions in consideration that edit of units may

48
cause unnecessary trouble. The 8 units edited when when the scale is released from factory are shown as below:
Number Instructions
1 Default weight unit
2 Default count unit
3 Kg unit
4 g unit
5 ton unit
6 lb unit
7 500g unit
8 100g unit
9~19 System reserved unit
20~99 Unit for user to add
N o t e 1 Default weight unit is the measure unit of the scale.
Example 5-9 Unit Programme
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter DTSet 【2】 P21 DTSet Dept
Enter unit P24 UNT.00 NoSet 0
【4】
programme Step No. Step Info Object
Enter number 30 【3】【0】 P24 UNT.00 NoSet 30
Next 【→】 P24 UNT.01 Name OK-Edit
Set unit name 【Confirm】 En-1 0 Unit name printed as unitage
Clear orginal text 【End】 En-1 0
Save editting text 【Amend】 P24 UNT.01 Name OK-Edit Save unit to buffer
Save editing unit 【Amend】 P24 UNT.00 NoSet 0 Go on edit other unit
Return to sale
【Slae】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
mode
5.4.5 Barcode Programme
Barcodes have different meanings in various applications and coding systems. Some barcodes are already edited
when the scale is released from factory. Users could choose some barcodes from them to use or edit the barcode
for themselves.
Number Use Instructions
1~9 Factory Default Already edited when the scale is released from factory
User cannot edit them.
10~99 User’s barcode Barcode that can be edited by users
Example 5-10 Barcode Programme
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.

49
Enter DTSet 【2】 P21 DTSet Dept
BAR.00 NoSet 0
Enter barcode 【5】 P25
Step No. Step Info Object
Enter number 10 【1】【0】 P25 BAR.00 NoSet 10
Next 【→】 P25 BAR.01 Name OK-Edit
Barcode names would usually not
be printed. And they are always
Edit barcode names used for management in PC. So
editing their names is of little
meaning. Here we skip it off.
See Table 5-1 List of Barcode
Next 【→】 P25 BAR.02 Type 0
Types.
See Table 5-2 Check Digit of
Next 【→】 P25 BAR.03 Check 0
Barcode.
Next 【→】 P25 BAR.04 NCon1 0 It could be used as fixed number
Next 【→】 P25 BAR.05 Ncon2 0 in barcode data.
Next 【→】 P25 BAR.06 Des OK-Edit
Barcode descriptions should be
in exact appointed format and
edit a text with the length of 24.
Otherwise the format would be
Edit the descriptions of
P25 invalid when it’s printed.
barcodes
Please refer to the content of
Table 5-3 Descriptions of
Barcode Data Items and Table
5-4 Factory Default Barcode.
Save editing barcode 【Amend】 P25 BAR.00 NoSet 0 Continue to edit other barcodes.
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Table 5-1 List of Barcode Types
Barcode formats Instruction Valid number digit (suggest)
0 Default
1 EAN13 12
2 EAN8 7
3 UPC A 11
4 UPC E 6
5 EAN-128 Even or Odd with Checksum
6 Code-128C Even or Odd with Checksum
7 ITF-25 Even or Odd with Checksum
N o t e 1 When select default, it will auto select the most reasonable barcode format according to valid
number digit
N o t e 2 When print EAN-128, Code-128C or ITF-25, if length of number is odd number, it will auto add one
checksum at the end. The arithmetic is same as EAN/UPC checksum

50
Table 5-2 Check Digit of Barcode
0 All checks
1 End Check
Check ways
2 Middle Check
3 Not check
N o t e 1 Check digit of barcode for barcode formats is just an advice for the scale. The scale would process
the check based on the selected barcode format. For example, EAN13 is verified by End Check no
matter which kind of check is selected.
Table 5-3 Descriptions of Barcode Data Items
Items Restrictions Instructions
A Not print
B Spec Flag
C Constant Num 1
D Constant Num 2
E PLU Number
F PLU Item-Code
G PLU Index
H PLU Flag
I PLU real U.Price
Data Source A~Z J PLU count/weight
K PLU T.Price
L Sale T.Price
M Sale T.Count
N Sale T.Weight
L Add-up Times
P Sales man number
Q Sale date: year
R Sale date: month
S Sale date: date
Display Length 0~9 Print length 0~9
Data Shift 0~9 Move to right 0~9 digits
0: not print
Overflow 1: truncation print
0~3
management 2: fill in with character 0
3: fill in with character 9
Table 5-4 Factory Default Barcode
Number Name Descriptions Use Instructions
2 digits Spec Flag,
Item
1 B-Item 1 B201E500K500A000A000A000 5 digits PLU Number,
barcode
5 digits PLU T.Price.
2 digits Spec Flag,
Item
2 B-Item 2 B201F500K500A000A000A000 5 digits PLU Item-Code,
barcode
5 digits PLU T.Price.
Item 7 digits PLU Item-Code,
3 B-Item 3 F700K500A000A000A000A000
barcode 5 digits PLU T.Price.

51
2 digits Spec Flag,
Item
4 B-Item 4 B201E400K600A000A000A000 4 digits PLU Number,
barcode
6 digits PLU T.Price.
2 digits Spec Flag,
Item
5 B-Item 5 B201F400K600A000A000A000 4 digits PLU Item-Code,
barcode
6 digits PLU T.Price.
Item 6 digits PLU Item-Code,
6 B-Item 6 F600K600A000A000A000A000
barcode 6 digits PLU T.Price.
Total 7 digits Spec Flag,
7 B-Sum 1 B701L500A000A000A000A000
barcode 5 digits Sale T.Price.
Total 6 digits Spec Flag,
8 B-Sum 2 B601L600A000A000A000A000
barcode 6 digits Sale T.Price.
Total 5 digits Spec Flag,
9 B-Sum 3 B501L700A000A000A000A000
barcode 7 digits Sale T.Price.
5.4.6 Print Formats Programme
Number Use Instructions
1~9 Factory default Already edited when the scale is released from factory
10~39 User’s print format Print format can be edited by users
Different print formats are needed in various applications. Some print types are already edited when the scale
is released from factory. Users could choose some formats from them or edit the format for themselves. It’s very
hard to edit print format on the scale. Suggest users do not edit print format on the scale.
This chapter would not offer any examples about print formats edit. Users should use the software on PC to
edit print formats or write down demands and send them to us. We will edit the print format you need.
Table 5-5 Factory Default Print Formats
No. Format Gap Paper Plain Paper
1 Item Label 58mm*40mm 58mm
2 Item Label 40mm*30mm 40mm
3 Item Label 58mm*30mm 58mm
4 Total Label 58mm*40mm 58mm
5 Total Label 40mm*30mm 40mm
6 Total Label 58mm*30mm 58mm
7 Receipt 58mm
8 Receipt 40mm
9 Receipt 48mm
N o t e 1 If users use gap paper in size of 58mm*30mm, set the value of Spec000 to 1, Spec001 to 4.
N o t e 2 If users use gap paper in size of 40mm*30mm, set the value of Spec000 to 2, Spec005 to 5.
N o t e 3 If users use gap paper in size of 58mm*30mm, set the value of Spec000 to 3, Spec005 to 6.
N o t e 4 If users use plain paper in width of 58mm, set the value of Spec000 and Spec005 to 7
N o t e 5 If users use plain paper in width of 40mm, set the value of Spec000 and Spec005 to 8.
N o t e 6 If users use plain paper in width of 48mm, set the value of Spec000 and Spec005 to 9.
Table 5-6 Factory Default Print Formats for cash register scale
No. Format Gap Paper Plain Paper
1 Receipt 48mm Print PLU number

52
2 Receipt 48mm Print number
3 Receipt 48mm New Line mode with Name
4 Receipt 48mm Large Font Mode
8 List 48mm Cookroom Use List
9 List 48mm Cookroom Use List, Large Font Mode
N o t e 1 User can use format 8 or 9, when remote printer is used as a cookroom printer.
If user really need to edit print format on the scale, please refer to 5.2.3 List of Programme Interface of P26
print format, following table are example to user refer:
Table 5-7 Print format: Print-item instruction
Print Item Name Sort Length Number Range Instruction
Item No. Number Number 1 0~99 Unique number with order
Sign 1 Flag1 Code 1
Sign 2 Flag2 Code 1 Refer to later table
Sign 3 Flag3 Code 1
0: Not Print
1: Print
2: By-weight PLU print
3: By-count PLU print
4: Temporary PLU print
5: Tared PLU print
6: Free PLU print
Print State Print Code 1 0~255 7: Print with sale date
8: Print with packing date
9: Print with shelf date
10: Not 1pcs PLU print
11: Item service charge print
12: Service charge print
13: Taxed PLU print
Other: not defined
Angle Angle Code 1 0~3 Clockwise rotation: Angle*90
Snap to grid Grid Code 1 0~9 1~9: 9 position, 0: default
3~5 Version before V2.03
Font CFont Code 1
0~9 Version after V2.03 and V2.03
X Position S-X 2 0 ~ 65535
Coordinate Start coordinate for print area
Y Positon S-Y 2 0 ~ 65535
Width L-X 2 0 ~ 65535
Coordinate Height and width for print area
Height L-Y 2 0 ~ 65535
Table 5-8 Print format: Print-item code
Flag1 Flag2 Flag3
Code Content Code Content Code Content
0 Readable Flag3 blank means no effect.
0 Barcode
1 Not Readable Followed are the same
1 Item Info 0 X 0 Name ‘X’ in Flag2 means print all
1 1 1 Amount cargo in turn.
2 2 2 Tare If Flag2=3, it means print
3 3 3 First Unit Price the information for the third
4 4 4 Payable Unit Price accumulate cargo’s

53
5 5 5 Price
6 6 6 PLU Number
7 7 7 Class Number
8 8 8 Dept. Number
9 9 9 Index
10 10 10 Item-Code
11 11 11 Sale Date
12 12 12 Sale Time
13 13 13 Package Date
14 14 14 Package Time
15 15 15 Shelf Date
… … 16 Text 1
18 18 17 Text 2
19 19 18 Text 3
20 20 19 Text 4
21 21 20 Text 5
22 22 21 Text 6
23 23 22 Text 7
24 24 23 Gross
25 25 24 Measure Unit
26 26 25 Price Unit
27 27 26 Price without Tax
28 28 27 Tax
29 29 28 Item Service Fee
30 30 29 Tax Rate
31 31 30 PLU No and Name
2 Sale Info 0 Store Name
1 Device Name
2 Device Number
3 Print Date
4 Print Time
5 Add-up Times
6 Total Count
7 Total Weight
8 Total Price
9 Payment
10 Change
11 Rounding Money
12 Unit of Weight
13 Unit of Weight Price
14 Unit of Count
15 Unit of Count Price
16 Unit of Money
17 Device Postil 1
18 Device Postil 2
19 Device Postil 3
20 Device Postil 4
21 Device Postil 5

54
22 Device Postil 6
23 Device Postil 7
24 Device Postil 8
25 FID 0~8 Least Digital
26 SID 0~8 Least Digital
27 Net Price
28 Gross Price
Money of Discount and
29
Rounding
30 Salesman No.
31 Salesman Name
32 Total Price without Tax
33 Total Tax
34 Waiter Number
35 Waiter Name
36 Text of Item Service Fee

37 Text of Service Fee

38 Industry Mark
39 Reserved 4
40 Reserved 5
41 Reserved 6
42 Reserved 7
43 Reserved 8
44 Service Fee
45 Tax of Service Fee
46 Service Fee without Tax
47 Buffer Number
3 Const Text 0~15 0~15 Flag2 is text series number
Outline Flag2 is outline boarder
4 1~24 1~24
Border thickness
0 Area Flag
5 Partition 1 Page Print 0 ~32 0mm~32mm
2 Line Print
5.4.7 Salesman Programme
Example 5-11 Salesman Programme
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
P1 TMSet
Enter programme 【Prog】 〖Prog〗 on.
Step No. Step Info Object
Enter DTSet 【2】 P21 DTSet Dept
Enter salesman programme 【7】 P27 SAL.00 NoSet 0
Enter salesman 10 【1】【0】 P27 SAL.00 NoSet 10
Next 【→】 P27 SAL.01 Name OK-Edit
Edit salesman name Process is omitted.

55
Next 【→】 P27 SAL.02 Pass 0
Edit salesman password
Save editing salesman 【Amend】 P27 SAL.00 NoSet 0 Continue to edit other salesmen.
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 Number 1~99 is the content for users to edit.

5.5 Assistant Data Programme


5.5.1 Steps Select of PLU Programme
Example 5-12 Steps Select of PLU Programme
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter DTAss 【3】 P31 DTSet Sk-PLU
P31 PLU.00 NoSet Prog 0
Enter step selection
【1】 PLU Step Prog or
of PLU prog
Step Info Skip
Select step: ICode 【→】 P31 PLU.01 ICode Prog 0
Default index number is not
Select step: Index Barcode 【→】 P31 PLU.02 Index Skip 1
activated.
Enable step: Index Barcode 【↓】 P31 PLU.02 Index Prog 0 Amend to activation.
Select step: Unit 【→】 P31 PLU.03 Unit Prog 0
Select step: U.Price 【→】 P31 PLU.04 Price Prog 0
Select step: Cost 【→】 P31 PLU.05 Cost Prog 0 Default cost is activated.
Disable step: Cost 【↓】 P31 PLU.05 Cost Skip 1 Amend to not activated.
Save steps selection 【Amend】 P31 DTSet Sk-PLU 0
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 The steps above activate steps Index Barcode and shield steps Cost.And then there is a step to input
index in the programme of P23, but no step to input cost. Select Prog or Skip by pressing【0】\【1】 or
【↑】【
\ ↓】. If Prog is selected, the step is in the programme. If Skip is selected, the step is skiped and
not in programme.
N o t e 2 Amended content would be in effect only in PLU programme and not effective in fast-prog.
5.5.2 Steps Select of PLU Fast Programme
Example 5-13 Steps Select of PLU Fast Programme
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter DTAss 【3】 P31 DTSet Sk-PLU
Enter step selection of 【2】 P32 PLU.00 NoSet Prog 0

56
PLU fast prog PLU Step Prog or
Step Info Skip
Select step: ICode 【→】 P32 PLU.01 ICode Prog 0
Default index number is not
Select step: Index 【→】 P32 PLU.02 Index Skip 1
activated.
Enable step: Index 【↓】 P32 PLU.02 Index Prog 0 Amend to activation.
Select step: Unit 【→】 P32 PLU.03 Unit Prog 0
Select step: U.Price 【→】 P32 PLU.04 Price Prog 0
Select step: Cost 【→】 P32 PLU.05 Cost Prog 0 Default cost is activated.
Disable step: Cost 【↓】 P32 PLU.05 Cost Skip 1 Amend to not activated.
Save steps selection 【Amend】 P32 DTSet Sk-PLU 0
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 The processes are the same as Example 5-12 only if amended contents only work in PLU fast-prog
instead of PLU programme.
5.5.3 Delete Sale Data
When entering the interfaces of delete, users would be requested to receive validate code. Validate code is
9958. Confirm and enter delete process.
Example 5-14 Delete PLU20~30
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter DTAss 【3】 P31 DTSet Sk-PLU
Enter interface of delete 【3】 Input Code 0 Request input validate code .
【9】
【9】 【5】
Input validate code Input Code 9958
【8】
【1】: Dept.,
【2】: Class,
【3】: PLU,
Confirm validate code 【Confirm】 P331 DTSet Delete Dept 【4】: Unit,
【5】: Barcode,
【6】: Print Format
【7】: Salesman.
Select to delete PLU 【3】 Input 2-1 0
【2】【0】
Input start number Input 2–2 0
【Confirm】
【3】【0】
Input end number P333 DTSet Delete PLU
【Confirm】
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 Once confirming to delete object, users shall be requested to input 2 numbers. And system would
delete data objects in the range between the two numbers. If the 2nd number is 0, the object appointed
by 1st number is deleted. If 2nd number is less than 1st number, no object is deleted.

57
5.6 Communication and Data Update
5.6.1 Operations of files in USB flash Disk.
Data edited on PC could transfer by USB flash disk.
The software would create a file in the directory of JHSCALE when exporting a file to USB flash disk.
If users export auto-update file, the form of file is A_xxx.TMS. If the scale has set USB flash disk
auto-update (factory default setting), after switch on, the scale would update the data when system detects the file
in USB flash disk
In P41, press【×】 to select auto-update file A_xxx.TMS, or input number to select numbered files from
A_000.TMS to A_999.TMS (The number is file serial number ). Press【Confirm】to load file data and update the
information in the scale. Or press 【Amend】 to save scale information to appointed file.
Example 5-13 Load Files in USB Flash Disk
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Make sure USB flash disk
Enter Commu 【4】 P41 Commu U-Disk
exists.
Enter operation of
【1】 P41 Commu U-Disk 000
USB flash disk
Input number here to load
numbered file.
Appoint auto-update
【×】 P41 Commu U-Disk XXX Please make sure selected
file
files are in the directory
JHSCALE.
0 0 0 Dw-Data When operation finishes
Load files 【Confirm】 Number of Number of Number Working normally, the state change
Error Data Right Data of Bytes State into finish.
Several seconds 0 … … Finish
Exit 【Confirm】 P41 Commu U-Disk Press any key to quit.
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 If file is loading ends normally, system would change the state into Finish. Normally, the amount of
error commands should be 0.
N o t e 2 If system encounters with invalid files or other serious mistakes, change the state into Error.
N o t e 3 In the state of Finish or Error, press any key to exit. If users want to exit midway, press 【Cancel】.
Example 5-14 Save working data to Files in USB Flash Disk
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter Commu 【4】 P41 Commu U-Disk Make sure USB flash disk

58
exists.
Enter operation of
【1】 P41 Commu U-Disk 000
USB flash disk
Appoint numbered Press 【 × 】 to select
【1】【2】 P41 Commu U-Disk 012
file auto-update file.

0 0 0 Up-Data When operation finishes


Save file 【Amend】 normally, the state change
Data Data Number of Working into finish.
Sort Number Saved Data State
Several seconds … … … Finish
Exit 【Confirm】
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 Exporting data to files in USB flash disk may take a lot of time. Please wait.
N o t e 2 Press any key to exit when saving is ended. If users want to exit midway, press 【Cancel】.
Example 5-15 Save sale list to Files in USB Flash Disk
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Make sure USB flash disk
Enter Commu 【4】 P41 Commu U-Disk
exists.
Enter operation of
【1】 P41 Commu U-Disk 000
USB flash disk
Appoint numbered Press 【 × 】 to select
【1】【2】 P41 Commu U-Disk 012
file auto-update file.
【 PLU 】 save the
0 0 0 Up-Data un-uploaded sale list
【F-Prog】+【PLU】 save
Save file 【PLU】
Data Data Number of Working all un-deleted sale
Sort Number Saved Data State list( PC software’s
repeat upload)
Several seconds … … … Finish
Exit 【Confirm】
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 Exporting data to files in USB flash disk may take a lot of time. Please wait.
N o t e 2 Press any key to exit when saving is ended. If users want to exit midway, press 【Cancel】.
5.6.2 Ethernet Monitor Interface
Example 5-16 Enter Ethernet Monitor Interface
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.

59
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Make sure USB flash disk
Enter Commu 【4】 P41 Commu U-Disk
exists.
0 0 0 Dw-Data Ethernet download
Enter Ethernet
【2】 Number of Number of Number Working information and Stat.
monitor interface
Error Data Right Data of Bytes State information
0 0 0 Up-Data Ethernet upload
Transfer upload and
【×】 Data Saved Working information and Stat.
download Data area
number data State information
Press any key to quit. If
Exit 【Cancel】 P42 Commu Ethernet want to exit in the
midway, press 【Cancel】
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 This monitor interface is usually used when the scale is set to not update in real-time on Internet.
5.6.3 RS232 Communications
The interface is similar to ethernet monitor interface. If want to process RS232 communication, must
firstenter this interface

5.7 Hardware Assistant


5.7.1 Validate Code
On the purpose of preventing any misoperation in important operation interfaces, users are requested to input
validate code when entering these operation interfaces. The interface is shown below:
Input Code 0
Validate code of this scale is 9958. When the scale requests to input validate code, users should first make
sure whether this operation interface is the one you intend to enter and understand the meaning of this operation.
Then input validate code and do operations.
5.7.2 Password
Password is the code to obtain the right to operate the scale. And there are 5 passwords in all.
Amend Password type Original
Types Permission
steps password
Admin password Hardware Assistant
200806
(P51)
Please keep it
P511 Admin Sale interface
safe if users
Prog interface
amend it.
Account interface
P512 Sale Sale password Sale interface 0
Program
P513 Prog Prog interface 0
password
Account
P514 Account Account interface 0
password
N o t e 1 That Password is 0 means no passwords needed. Users could set the password to be 0 when
canceling the password.
N o t e 2 Admin password is in a higher level than the other 4 passwords. Users do not need to input any

60
password to enter all interface if admin password is 0 , no matter whether the other passwords are 0.
N o t e 3 If users want to protect Prog interface or Account interface, first change the admin password other
than factory default, then set passwords of corresponding interfaces.
N o t e 4 Spec247’s password hold function can let the device remember the entered password, then, user do
not need to input the same password repeatedly
Example 5-17 Process of Amending Passwords
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter hardware Assistant 【5】 Input Pass 0
Display dashes is the as many
Input admin password …… Input Pass -------
as input numbers.
Confirm password 【Confirm】 P51 HwAss Set-PW
Amend password 【1】 P511 HwAss Set-PW Admin
【1】: admin password
【2】: sale password
【3】: program password
Amend prog password 【3】 Input Pass-1
【4】: account password
【 5 】 : 【 open drawer 】
password
Input password ……【Confirm】 Input Pass-2 -------
Repeat password ……【Confirm】 P513 HwAss Set-PW Prog
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 Input password must match for two times so that password setting can be done.
5.7.3 Recover Factory Default Setting
Example 5-18 Process of Amending Passwords
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter programme 【Prog】 P1 TMSet 〖Prog〗 on.
Enter hardware Assistant 【5】 Input Pass 0
Display dashes is the as many
Input admin password …… Input Pass -------
as input numbers.
Confirm password P51 HwAss Set-PW
Recovery factory default 【2】 P521 HwAss TMS-DF Fac-Set
Here are 4 recovery types:
【1】Scale parameter(P1x)
Select the type to amend 【4】 Input Code 0 【2】default working data
【3】all working data(P2x)
【4】all parameters and data
Input validate code 【9】
【9】【5】 【8】 Input Code 9958

61
Confirm validate code 【Confirm】 P521 HwAss TMS-DF Fac-All
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 Please pay attention to this. Execute recovery 1 or 4, and then passwords would change to factory
default.
N o t e 2 If user amend the Spec irrelevantly, it will make scale do not work regularly, suggest user to
executeP511
N o t e 3 P524 will let the scale recover to factory default state(all user’s data will be deleted)

62
6 Account Operations

6.1 List of Account Interfaces


Entering to Account interface, the scale would enter a calculate process, which first calculate sale records.
Then enter A1 select interface.
Table 6-1 List of Account Interfaces
Menus Menu Prompt Instructions Remarks State
A1 Total Total report
A11 Total Daily Total daily report
A12 Total Monly Total monthly report
A13 Total Qualy Total quarterly report
A14 Total Manly Total manual report
A2 Dept Department report
A21 Dept Daily Department daily report
A22 Dept Monly Department monthly report
A23 Dept Qualy Department quarterly report
A24 Dept Manly Department manual report
A3 Class Class report
A31 Class Daily Class daily report
A32 Class Monly Class monthly report
A33 Class Qualy Class quarterly report
A34 Class Manly Class manual report
A4 PLU PLU report
A41 PLU Daily PLU daily report
A42 PLU Monly PLU monthly report
A43 PLU Qualy PLU quarterly report
A44 PLU Manly PLU manual report
A5 Clear Clear report
A51 Clear Manly Clear current manual report information
A52 Clear All Clear all reports and records information
A53 Clear Stock Clear stock report information
A54 Clear SID Clear SID information, reset to 0
A6 Stock Stock report
A61 Stock Print Stock print
A62 Stock Audit Stock update
A7 List Sale list report
A71 List Print Sale list print
A8 Sales Salesman report
A81 Sales Daily Salesman daily report
A82 Sales Monly Salesman monthly report
A83 Sales Qualy Salesman quarterly report
A84 Sales Manly Salesman manual report

6.2 Operations of Printing Report


6.2.1 Print Total Report
Total reports are divided into total daily report, total monthly report, total quarterly report and total manual

63
report. Each report owns 32 buffer zones (0~31).
Take total daily report as an example: The buffer zone 0 stores total daily report of current day; buffer zone 1
stores total daily report of the last day. The rest may be deduced by analogy. So buffer zone 31 stores total daily
report of the day dating back to 31 days ago.
Total monthly report and total quarterly report works in the same way, storing total report of the last x
months or quarters (x=0~31).
Total manual report would take operation A51 as time point to divide the storage. The buffer zone delays a
position automatically when a report is cleared (That means: Buffer 31 records the information which was stored
in buffer 30. By analogy, buffer 1 record the information which was stored in buffer 0 and information stored in
buffer 0 is cleared. Then start accumulating in buffer 0. ).
When printing total report, system would request to input 2 numbers. And the scale would print total buffer
which is added up with the buffers whose numbers are between the 2 input numbers.
Example 6-1 Print Daily Reports of Today and Yesterday
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
【1】: Total report
【2】: Dept. report
Enter total report 【1】 A11 Total Daily
【3】: Class report
【4】: PLU report
【1】: Daily report
【2】: Monthly report
Enter total daily report 【1】 Input 2–1 0
【3】: Quarterly report
【4】: Manual report
Input start number 【0】 【Confirm】 Input 2–2 0 Start from today.
Input end number 【1】 【Confirm】 … … … … End at yesterday.
Print daily report of today.
A11 Total Daily 0
(Note 4)
Print daily report of yesterday.
A11 Total Daily 1
(Note 4)
A11 Total Daily End of print.
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 If some buffers store no data, these buffers would be skiped off without printing.
N o t e 2 If end number input is 0, system would only print the buffer appointed by start number.
N o t e 3 If end number input is not 0 and less than start number, no buffer would be printed.
N o t e 4 The hints about currently print object may appear on the screen for just a few moment when system
is printing.
6.2.2 Print Department Report
The scale could print report of all departments. Operation steps are similar as Print PLU Report.
Only the step to enter is different and 2 input numbers is the department numbers.

64
6.2.3 Print Class Report
The scale could print reports of all Classes. Operation steps are similar as Print PLU Report.
Only the step to enter is different and 2 input numbers is the class numbers.steps
6.2.4 Print PLU Report
The scale could print PLU reports whose number is less than 1000.
When printing PLU reports, system would orderly print those PLU reports whose serial numbers is between
the 2 input numbers as well as the 2 input numbers.
Example 6-2 Print PLU Daily Reports with the Numbers from 10 to 20
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
【1】: Total report
【2】: Dept. report
Enter PLU report. 【4】 A41 PLU Daily
【3】: Class report
【4】: PLU report
【1】: Daily report
【2】: Monthly report
Enter PLU daily report 【1】 Input 2–1 0
【3】: Quarterly report
【4】: Manual report
【1】【0】
Input start number Input 2–2 0 Start from PLU10.
【Confirm】
【2】【0】
Input end number … … … … End to PLU20.
【Confirm】
10 Print Print daily report of PLU10.
11 Print Print daily report of PLU11.
… Print
End of print.
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 If some buffers store no data, these buffers would be skiped off without printing
N o t e 2 If end number input is 0, system would only print the buffer appointed by start number.
N o t e 3 If end number input is not 0 and less than start number, no buffer would be printed.

6.3 Clear Report Information


6.3.1 Clear Report Information Manually
The information in manual reports would not be cleared automatically unless users enter A51 (clear current
manual report) interface to clear it. After this operation, manual reports of all departments, classes and PLU would
be cleared, and total manual report would delay its serial number.

65
Example 6-3 Clear Information in Manual Report
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
Enter clear report 【5】 A51 Clear Manly
Clear manual report 【1】 ---- ----- ------ ------- Wait a few seconds.
A51 Clear Manly
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
6.3.2 Clear All Reports and Records Information
Example 6-4 Clear All Reports and Records Information
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
Enter clear report 【5】 A51 Clear Manly
Clear manual report 【2】 Input Code 0 Input validate code.
【9】【9】【5】
Input validate code
【8】
Confirm validate code 【Confirm】 ---- ----- ------ -------
A52 Clear All
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 This operation would clear the records of all deals. And it’s irreversible. Please operate it carefully.
6.3.3 Clear stock information
Example 6-5 Clear stock information
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
Enter clear report 【5】 A51 Clear Manly
Clear manual
【3】 Input Code 0 Input validate code.
report
Input validate code 【9】
【9】【5】 【8】
Confirm validate
【Confirm】 ---- ----- ------ -------
code
A53 Clear Stock
Return to sale
【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
mode
N o t e 1 This operation would clear stock report. And it’s irreversible. Please operate it carefully.

66
6.3.4 Reposition SID information
Example 6-6 Clear manual report
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
Enter clear report 【5】 A51 Clear Manly
Clear manual
【4】 ---- ----- ------ ------- Wait a few seconds.
report
A54 Clear SID
Return to sale
【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
mode

6.4 Stock Management


6.4.1 Stock Management
A6’s stock report and A44’s manual PLU report are choiceable( by Spec141) .
Stock report only support first 1000 saved PLU, if the real input PLU number >1000, the partial PLU can
notprocess stock management
6.4.2 Stcok Print
When print stock report, it will clue to input 2 digits, scale will in turn print the stock report those PLU
reports whose serial numbers is between the 2 input numbers as well as the 2 input numbers.
Example 6-7 Print stock Reports with the Numbers from 10 to 20
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
Enter stock
【6】 A61 Stock Print
management
Enter stock print 【1】 Input 2–1 0
【1】【0】
Input start number Input 2–2 0 Start from PLU10.
【Confirm】
【2】【0】
Input end number … … … … End to PLU20.
【Confirm】
10 Print Print stock report of PLU10.
11 Print Print stock report of PLU11.
… Print ……
End of print.
Return to sale
【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
mode
N o t e 1 If some stock reports store no data, these buffers would be skiped off without printing
N o t e 2 If end number input is 0, system would only print the buffer appointed by start number.

67
N o t e 3 If end number input is not 0 and less than start number, no buffer would be printed.
6.4.3 Stock Audit
Example 6-8 Amend PLU10 stock to 100
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
Enter stock
【6】 A61 Stock Print
management
Enter stock print 【2】 Input PLU-no 0
A61 pcs 0 10
Pcs means default count unit.
【1】【0】
Enter PLU number Present When PLU is for weight, default
【Confirm】 Stock unit PLUnumber
stock stockunit is scale’s unit kg
Enter stock 【Amend】: amend stock to input
【1】
【0】【0】 A61 pcs 100 10
quantity 100 number
【Confirm】: add input number to
Amend to the stock
【Amend】 A61 pcs 100 10
imput number 【F-Prog】+【Confirm】: reduce
input number from stock
Return to sale
【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
mode
N o t e 1 Use【F-Prog】+【PLU】 can amend the stock unit, make the weight PLU also with count stock.
Generally do not suggest user use this function. Detailed refer to Spec142

6.5 List Print


6.5.1 Sale Log
When user sale in sale interface, sale data will be recorded. This recorded data is source of all account
modes’ Stat. Date. Device has about 6000~10000 location according to different device’s configure. When the
log is being over capability, device will delete oldest log according to FIFO rule.
6.5.2 List Print
Example 6-9 Intraday List Print
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
Enter stock
【7】 A71 List Print
management
Last window display the
Enter stock print 【1】 A71 List Print 20 location number used by
intraday
Start print 【Confirm】 1 Print Print first unit’s record

68
2 Print Print second unit’s record
… Print ……
Print finished
Return to sale
【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on
mode
Example 6-10 Appointed Time Period List Print
Display
Operations Keys Weight/ Change/ Single/ Remarks
Tare
Count U.Price Total
『Sale Idle』 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on.
Enter Account 【Account】 A1 Total 〖Account〗 on.
Enter stock
【7】 A71 List Print
management
Last window display the
Enter stock print 【1】 A71 List Print 20 location number used by
intraday
Enter time period 【×】 Input Time-1
2009 01 01 00 00 00 W-4
Enter start time 【…】
【Confirm】 … …… …… ……
Input Time-2
2009 01 01 23 59 59 W-4
Enter finish time 【…】
【Confirm】 … …… …… ……
Last window display the
A71 List Print 30 location number used by
appointed time period
Start print 【Confirm】 1 Print Print first unit’s record
2 Print Print second unit’s record
… Print ……
End print
Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on

69
7 Appendix

7.1 Reference Table For Errors and Its Instructions


Number Alarm instructions Methods to handle
E0.00 Alarms for measurements
Weight is not stable when the scale Make sure there is no heavy goods on the tray and the tray
E0.01
start-up. is stable. If scale still warns, the sensor may go wrong.
Make sure there is no heavy goods on the tray and the tray
E0.02 Exceed the allowed start-up zero range is on the bracket, If scale still warns, the sensor may go
wrong.
E1.00 Alarms for operations
E1.01 Prog data is invalid. Input valid data again.
Input passwords of 2 times to amend Re-amend password, and make sure 2 times input are the
E1.02
password are different same.
E1.03 The selected print format do not exist Set print format again
The sale whose sell price is 0 is forbidden. Refer to
E1.10 Sale at 0 price is forbidden.
Spec070.
Total price or grand total price of sold goods exceeds the
E1.11 Exceed the largest sale price.
largest sale price.
E1.12 Need to return to zero point Return to weight zero before sale. Refer to Spec069.
E1.13 Exceed accumulative limit The accumulative times are over buffer accumulat limit
There is data in buffer and cannot print Print the data in buffers first. Then print this sale or switch
E1.14
in single. to other buffers.
No cashing mode, cannot executethe
E1.15 The scale is set to be no cashing mode. Refer to Spec060.
cashing operation.
Cashing mode with zero change Execute cashing operation afer inputing payment amount.
E1.16
default is forbidden. Refer to Spec060.
E1.17 Payment is less than sale price. Charge enough money which is larger than sale price.
System cannot execute accumulative Before accumulative operations, system needs to exit lock
E1.18
operations while locking PLU. PLU (or auto mode) first.
System cannot switch buffers into
Operate in current buffern, or exit lock PLU (or auto
E1.19 buffer with accumulation while
mode).
locking PLU.
Not allow no weigh sale for weight
E1.20 Refer to Spec071.
goods
E1.21 Less than smallest sale weight Weight needs to be larger than smallest sale weight.
E1.22 Larger than largest sale weight Weight needs to be smaller than largest sale weight.
Discounted U.Price has to be less than
E1.23
discount lower limit.
Discounted in allowed range, or amend the allowed range.
Discounted U.Price has to be higher
E1.24
than discount upper limit.
E1.25 Discount is forbidden. Refer to Spec110
E1.26 Manual weight entry is forbidden Refer to Spec077
Manual weight entry failed for weight
E1.27 Take off goods, or press 【Zero】
is not zero.

70
Number Alarm instructions Methods to handle
E1.28 T-Sale is forbidden Refer to Spec076
Sale of Weight PLU or count PLU is
E1.29 Refer to Spec075
forbidden.
Selected PLU haveconflict with special sale mode, select
E1.30 Can not enter special sale mode
again
Working on forced auto printing after
E1.31 Finish printing of current PLU.
zero-return. PLU Quiting is forbidden.
Transfer sale buffer is forbidden under Press 【 Confirm 】 or 【 Cancell 】 exit the accumulate
E1.32
accumulate mode mode,then go on transfer
E1.33 Transfer sale mode forbidden Refer to Spec079
Confirm the scanned PLU have been edited, interior
E1.34 The scanned barcode can not be parsed
barcode format station right
E1.35 Tare renew function forbidden Must turn over tare, then go for tare
E1.36 Salesman is not exist Login with exist personel
E1.37 Salesman’s password can not be 0 Login with personel whose password is not 0
E1.38 Service charge is forbidden Open the function at Spec307
E1.5x Custom Product Alarm E1.50~E1.59
E2.01 Forbid F-Prog of PLU Refer to Spec080.
E2.02 Forbid F-Prog of PLU shortcut keys Refer to Spec081.
E2.03 Forbid F-Prog of Spec data parameters Refer to Spec082.
E2.04 Forbid Re-print Refer to Spec065.
Menu quiting via pressing 【 Sale 】
E2.05 Quit the menu by press【Cancel】some times.
【Prog】【Account】 is forbidden.
E2.06 A44 report forbidden Refer to Spec141.
E2.07 A6 report forbidden Refer to Spec141.
E2.09 Illegal reboot Refer to Spec138.
E6.00 Alarms for peripheral
E6.10 PTR: Print sensor calibrate wrong Do calibrate operation with Ethernet Printer
Take away the printed label paper. If the alarm still
E6.11 PTR: Gap paper is not taken away.
warns, do calibrate operation with Ethernet Printer
E6.12 PTR: Print mouth is not closed tight. Install the paper and close mouth.
E6.13 PTR: Printer is working. Please wait for a few seconds and try again.
E6.14 PTR: Lack of plain paper Reinstall plain paper or the paper type cannot match.
Reinstall label paper or the paper type cannot match. If
E6.15 PTR: Lack of gap paper the alarm still warns, do calibrate operation with
Ethernet Printer
The paper type cannot match and change the type to plain
PTR: The printer cannot find the gap
E6.16 paper or reinstall gap label paper. If the alarm still
intervals.
warns, do calibrate operation with Ethernet Printer
PTR: The printer cannot find gap Label paper is used up or paper type cannot match with
E6.17
alignment positions. set paper type. Please reinstall label paper.
PTR: The printer is overheated and it
E6.18 Please wait for a few seconds and try again.
needs to cool down.

71
Number Alarm instructions Methods to handle
PTR: There is no response of the The printer may not be connected or in the state that the
E6.19
printer. printer could not print.
Printer process do not follow general time order and finish
E6.20 PTR: Print sensor calibrate wrong
the working, unknown print error
E6.21 PTR: Communication Error Checkup the Ethernet cable
E7.00 Alarms for hardwares
Please confirm that no keys are pressed.
In this interface, the last window display pressed keys. 8-5
Some keys are pressed when the scale means the key in 8th column from the left and 5th row from
E7.01
starts. the top is pressed.
In this interface, the second window displays the
calibrated times.
Refer to chapter 1.5.5 Abnormity of Gap Paper Print to
E7.10 Print sensor calibrate wrong
calibrate again
Take away the printed label paper. If there is still alarm
E7.11 Gap paper is not taken away. this problem, do as the way in chapter 1.5.5 Abnormity
of Gap Paper Print to detect.
E7.12 Print mouth is not closed tight. Install the paper and close mouth.
E7.13 Printer is working. Please wait for a few seconds and try again.
E7.14 Lack of plain paper Reinstall plain paper or the paper type cannot match.
Reinstall label paper or the paper type cannot match. If
E7.15 Lack of gap paper there is still alarm this problem, do as the way in
chapter 1.5.5 Abnormity of Gap Paper Print to detect.
The paper type cannot match and change the type to plain
paper or reinstall gap label paper. If there is still alarm
E7.16 The scale cannot find the gap intervals.
this problem, do as the way in chapter 1.5.5 Abnormity
of Gap Paper Print to detect.
The scale cannot find gap alignment Label paper is used up or paper type cannot match with
E7.17
positions. set paper type. Please reinstall label paper.
The printer is overheated and it needs
E7.18 Please wait for a few seconds and try again.
to cool down.
The printer may not be connected or in the state that the
E7.19 There is no response of the printer.
printer could not print.
Printer process do not follow general time order and finish
E7.20 The printer over time
the working, unknown print error
E7.23 PDS calibration failed, ignore PDS Try reclibrate, this failure will not effect general use
Enter Account interface. Calculate reports and then clear
E7.30 Alarm for full storage of deals records.
the reports.
Time module error, if scale work for years, then it means
E7.40 Time error
to change the battery on main board
E7.50 Harware error Inside examine and repair code, if restart again andagain,
E7.51 but still exist this question, need return to factory for
E7.52 repair

72
Number Alarm instructions Methods to handle
E7.53
E7.54 Font file check error Download font from Software again.
E7.61 No MAC device Please ask Service for MAC file.
Wire-Network module do not exist or If no wire-network module in present scheme, please
E7.62
working irregular close the network module (Set Spec043=0) .
Wireless-Network module do not exist If no wireless-network module in present scheme, please
E7.63
or working irregular choose wire-network module (Set Spec050=0) .
E7.70 AD work irregular or loadcell irregular Confirm loadcell install right
If device is working with battery, please charge it first.
E7.81 DC power is too low If user confirm that power is right, please set Spec235=1
to close the power detect module
If device is working with battery, it means battery is not
match with the device.
E7.82 DC power is too high
If user confirm that power is right, please set Spec235=1
to close the power detect module
E8.00 Alarms for communications
Please confirm that the scale used owns U-Disk port. If it
USB flash disk port do not connect
E8.11 owns, and this alarm cannot be cleared after several times’
with the scale.
reboot, please use the guarantee.
Please confirm that USB-Disk is correctly inserted with
two condition:
1. USB-Disk is formatted in FAT12/16/32. NTFS is not
E8.12 USB flash disk does not exist.
supported by device.
2. USB-Disk is bootloaded as FDD. HDD/ZIP are not
supported by device.
The file in USB flash disk does not
E8.13 Confirm that appointed files are inside of USB flash disk.
exist.

7.2 Definitions of Spec data parameters


Default values are different via different version. Value list blow is cfor reference only.
No. Content Range Remarks Default Permission
0 means not to print, 1~99 are to print in appoint
0 Bill 1: Item Print Format 0~99 1 0
Print formats.
0 means not to print, 1~99 are to print in appoint
1 Bill 1: Item Barcode Format 0~99 2 0
barcode formats.
0~
2 Bill 1: Item Barcode flag 20 0
9999999
3 Bill 1: Item Print Times 0~99 1 1
4 Bill 1: Item Print Reverse 0~1 0: No Reverse, 1: Print 180°Reversed 0 1
0 means not to print, 1~99 are to print in appoint
5 Bill 1: Sum Print Format 0~99 4 0
Print formats.

73
No. Content Range Remarks Default Permission
0 means not to print, 1~99 are to print in appoint
6 Bill 1: Sum Barcode Format 0~99 7 0
barcode formats.
0~ 209999
7 Bill 1: Sum Barcode Flag 0
9999999 9
8 Bill 1: Sum Item Print Times 0~99 1 1
9 Bill 1: Sum Print Reverse 0~1 0: No Reverse, 1: Print 180°Reversed 0 1
10 Bill 2: Item Print Format 0~99 0 1
11 Bill 2: Item Barcode Format 0~99 0 1
0~
12 Bill 2: Item Barcode Flag 0 1
9999999
13 Bill 2: Item Print Times 0~99 For the second-class Print formats, ordinary 0 1
14 Bill 2: Item Print Reverse 0~1 users won’t use them. 0 1
15 Bill 2: Sum Print Format 0~99 Please don’t amend them in normal conditions. 0 1
16 Bill 2: Sum Barcode Format 0~99 0 1
0~
17 Bill 2 Sum Barcode Flag 0 1
9999999
18 Bill 2: Sum Item Print Times 0~99 0 1
19 Bill 2: Sum Print Reverse 0~1 0 1
20 Print Speed Slow Down 0~99 Reduced % of paper speed 0 1
21 Paper Type 0~1 0: Plain Paper, 1: Gap Paper. 1 0
22 Gray Level of Gap Paper 0~15 0 is lightest, 9 is darkest. The print lighter, the 5 0
23 Gray Level of Plain Paper 0~15 damage to print header smaller. 5 0
Plain Paper: Interval of Each
24 0~99 0 0
Print Unit of setting number is mm.
25 Plain Paper: Cut-off Position 0~99 35 0
Plain Paper: Pre-feed Unit of setting number is dot.
26 0~1999 16 0
Distance Device is reverse feed if number > 1000
27 Wide of Report Printing 0~99 Unit of setting number is mm. 50 0
28 Font for Report Print 0~2 1 1
Continuously print appointed time will enter
29 Heat Protect 0~30 5 1
over-heat protect, Please don’t amend it.
Hardware properties. Please don’t amend them
30 Feed Sensor Position 0~255 180 1
without the guidance of professionals.
Narrow Bar Dot Number of
31 0~9 0 1
Barcode
0 for Default
Wide Bar Dot Number of
32 0~19 0 1
Barcode
Font of Barcode readable
33 0~2 0 1
character
Weighing's Anti-shake while Hardware property, Please don’t amend them
34 0~19 3 1
Printing without the guidance of professionals.
35 Auto New Line Mode 0~1 0: Forbidden; 1: Allowed 0 1
0: No frame; 1: Up and down frame;
36 ITF25 frame mode 0~2 1 1
2: Around frame
37 ITF25 frame width 0~31 Frame dots 8 1

74
No. Content Range Remarks Default Permission
ITF25 left and right blank
38 0~31 Left and right blank dots 20 1
width
Unit of setting number is dot.
39 Gap Paper: Pre-feed Distance 0~1999 0 0
Device is reverse feed if number > 1000
0~ They are used to distinguish more than one
40 Device Number 0 0
9999999 scale. And they can be printed.
0: 300, 1: 600, 2: 1200, 3: 2400, 4: 4800, 5:
41 RS232 Baud Rate 0~9 5 0
9600, 6: 19200, 7: 38400, 8: 57600, 9: 115200.
42 USB flash disk Auto Update 0~1 0: No Update, 1: Auto Update 1 0
43 Ethernet Mode 0~2 0: Disable; 1: Server Mode; 2: Client Mode 1 0
0: do not try connect again
44 Ethernet Auto Re-connect 0~65535 1~65535: Device will try to connect with PC 0 0
each appointed second
Ethernet Auto Reboot if 0: Disable, only reset change Ethernet config.
45 0~1 1 1
Configure Changed 1: Enable, Ethernet config apply immediately.
0: Default wait 2s; 1~99: wait0.1s--9.9s.
Latency Time of USB Suggest clients keep the default set. If some
46 0~99 0 1
Linking U-disk start slowly, you can try to change the
waiting time for longer
47 USB Power Always ON 0~1 1: Enable 0 1
Single overtime seconds, over 5 times overtime,
48 Ethernet Overtime Interval 0~31 10 1
Ethernet will disconnect
0: Device Operation Only
49 Password Authorization 0~1 0 1
1: Communication Operation Allowed
50 Ethernet Type (Need Reset) 0~1 0: Wire-Network; 1: Wireless-Network 0 1
51 Security Mode 0~2 0: No Security; 1: WEP; 2: WPA/WPA2 1 1
52 Security Option 0~1 0: Open System; 1: Shared Key 1 1
0: FCC; 1: IC; 2: ETSI; 3: Spain; 4: France; 5:
53 Domain Type 0~6 2 1
JapanA; 6: JapanB
57 RS232 POS Protocol 0~99 Refer to POS Protocol File 0 1
59 Sale Log Auto Save 0~1 1: Sale Log Auto Save to USB-Disk in Account 0 1
0: No Cashing Mode,
1: Cashing Mode With Zero Change Default, No
Display For Zero Change,
60 Cashing Mode 0~3 1 0
2: Cashing Mode With Zero Change Default,
Always Display For Zero Change,
3: Cashing Mode Without Zero Change Default.
61 Drawer In Sale Operation 0~3 0: Not Open Drawer, 1: Open Drawer 1, 3 0
2: Open Drawer 2, 3: Open Drawer 1 and 2.
62 Press【Drawer】in Sale 0~3 For general scale, only drawer 1 is valid, if user 3 0
have double drawer request, please contact us.
63 Press【Drawer】in Prog 0~3 The added drawer password only limit the 3 0
【Drawer】operation, open the drawer while
64 Press【Drawer】in Account 0~3 3 0
printing is not limited

75
No. Content Range Remarks Default Permission
0: Reprint Forbidden
1: Print One Piece of Bill 1
65 Reprint 0~4 2: Print One Piece of Bill 2 3 1
3: Print Each Piece of Bill 1 and 2
4: Print Bill 1 and 2 as Sale Operation
0: Push Any Key For Exit,
66 Change Display Exit 0~99 0 0
1~99: Auto Quit Exit Specified Second
0: Forbidden, 1: Input Value Tare,
67 Number Tare 0~2 0 0
2: Floating-point Value Tare.
0: Forbidden, No Resume Tare
1: Update If Current Tare Is Zero, No Resume Tare
2. Update if PLU Tare Is Not Zero, No Resume Tare
3. Always Update PLU Tare, No Resume Tare
68 PLU Tare 0~7 1 0
4: Forbidden, Resume Tare
5: Update If Current Tare Is Zero, Resume Tare
6. Update if PLU Tare Is Not Zero, Resume Tare
7. Always Update PLU Tare, Resume Tare
0: Always need Zero-Return;
69 Zero-Return For Weight Sale 0~2 1: Zero-Return is need if Weight Changed; 1 0
2: No Zero-Return need, Print "*" before weight
70 Allowed Zero Purchase 0~1 0: Forbid; 1: Allow 0 1
0: Forbid;
No Weigh Sale for Weight
71 0~2 1: Allowed, 1 pc only 0 0
PLU
2: Allowed, multi pcs allowed
Clear Sale Buffer if Press
72 0~1 0: Not clear, 1: Clear. 0 0
【Sale】
0: Forbid,
Think【T-Sale】As【U.Price
73 0~1 1: Allow. Convert the input U.Price unit from 0 0
Convert】
T-Sale Unit to Scale unit.
74 Return of Goods 0~1 0: Forbid, 1: Allow. 0 0
0: No forbidden; 1: Weight PLU forbidden;
75 PLU forbidden 0~3 0 1
2: Count PLU forbidden; 3: All PLU forbidden.
0: No forbidden;
T-Sale PLU transfer 1: T-Sale Weight PLU forbidden;
76 0~3 0 1
forbidden 2: T-Sale Count PLU forbidden;
3: All T-Sale PLU forbidden;
77 Manual Weight Entry 0~3 0: Disable, 1-3: Enable 0 0
0: Auto mode forbidden
1: Swith to batch print mode
【Auto mode】Get into
78 0~4 2: Swith to prepack print mode 2 0
Special Sale Mode
3: Swith to lock PLU mode
4: Swith to auto print mode
79 Sale mode select 0~1 0: Forbid, 1: Allow. 1 0
80 PLU Fast-Prog 0~1 0: Forbid, 1: Allow. 1 0
81 ScPLU Fast-Prog 0~1 0: Forbid, 1: Allow. 1 0
82 Spec Fast-Prog 0~1 0: Forbid, 1: Allow. 1 0

76
No. Content Range Remarks Default Permission
0: Forbid;
1: long press【-@】 change PLU saved unit price
Unit Price Fast-Prog
83 0~3 2: press【-@】change PLU default unit price 1 1
【-@】 or 【@Price】
3: press【-@】change PLU default unit price, long
press to enter PLUsaved name edit menu
Wait several seconds after pressing the key to set
Stable Waiting: Set Zero
85 0~99 zero. If it’s stable in time, execute setting zero. If 20 0
(Each 10 for 1 Second)
not stable, error beep would sound.
Wait several seconds after pressing accumulative
Stable Waiting: Sale
86 0~99 or print in sale. If it’s stable in time, execute sale. 20 0
(Each 10 for 1 Second)
If not stable, error beep would sound.
0: Disable
1: Use dummy PLU, when try to transfer one do
not exist PLU, device will use this PLU
87 Dummy PLU 0~1 number or other PLU item empty way to 0 1
transfer a dummy PLU. For example::
PLU156 do not exist, when transfer, you will
get a cargo name PLU-0156 ‘s PLU.
0: Disable
1: use dummy ScPLU, if one shout cut key have
been edited, then when it is transferred, scale
88 Dummy ScPLU 0~1 0 1
will transfer PLU according to its short cut
code. 【SC1】refer to PLU101, 【Shift】 【SC1】
refer to PLU201. Etc.
Step-skip of PLU Fast-Prog 0: Disable;
89 0~1 1 1
Equal to PLU Prog 1: Enable, P331 and P332 do same effect
Calculating Account Allow the scale to calculate report data in
90 0~1 1 1
Backgroud background. Suggest clients do not edit this item
91 Log record function 0~1 0: Enable, 1: Disable 0 1
0: use old version, PLU is 10~5999
92 Dummy PLU number 0~1 1: PLU is 1~9999999, temporary PLU number 1 1
decided by Spec093 and 096
Dummy number for 0~ 999999
93 1
Temporary weight PLU 9999999 9
Dummy number for 0~ 999999
94 1
Temporary count PLU 9999999 8
Refer to Spec092
Dummy number for Service 0~ 999999
95 1
Charge PLU 9999999 7
Dummy number for Discount 0~ 999999
96 1
& Rounding PLU 9999999 6
0: Forbidden; 1: Allow use number index
97 Index barcode from keyboard 0~2 1 1
2: Allow use number and character index
Single count deal: discount 0: Not Record
98 sum and rounding 0~5 1: Independent Record Discount, No Rounding 3 1
sum’smanage 2: Separate Record Discount, No Rounding

77
No. Content Range Remarks Default Permission
3: Independent Record Discount and Rounding
Accumulate deal: discount
4: Independent Record Discount, Separate
99 sum and rounding 0~5 3 1
Record Rounding
sum’smanage
5: Separate Record Discount and Rounding
0, Common Rounding For Redundancy Digit
1, Common Rounding For Last Digit
Rounding Method for Single 2, Common Rounding For Last 2 Digits
100 0~1 0 0
Total Price 3, Banker's Rounding For Redundancy Digit
4, Banker's Rounding For Last Digit
5, Banker's Rounding For Last 2 Digits
6, Rounding Down For Redundancy Digit
7, Rounding Down For Last Digit
Rounding Method for Sum 8, Rounding Down For Last 2 Digits
101 0~11 0 0
Tota Pricel 9, Rounding to 0/5 For Last Digit
10, Rounding to 0/5 For Last 2 Digits
11, Rounding to 0/5 For Last 3 Digits
102 Print with accumulated data 0~1 0: Enable, 1: Disable 0 1
Equal Reparation of Tare, 0: No Reparation; 1: Tare=Gross-Net;
103 0~3 3 1
Net and Gross 2: Net=Gross-Tare; 3: Gross=Net+Tare
0: YYYY.MM.DD; 1: YY.MM.DD
104 Date Type 0~5 2: MM/DD/YY; 3: MM-DD-YY 0 1
4: DD/MM/YY; 5: DD-MM-YY
0: Using PLU setting
1: Shelf Printing based-on Spec106 if PLU Do
105 Shelf Day Print 0~2 0 0
not set Shelf Day
2: Shelf Printing based-on Spec106
Shelf life days after intraday.
106 Shelf Days 0~999 0 0
0 means only for intraday
107 Number of Sale Buffers 0~99 0: maximum allowed buffer 0 0
Number of Maximum
108 0~65535 0: maximum allowed accumulate 0 0
Accumulate
109 Divide Operation of U.Price 0~1 0: Normal Operation; 1: Divide Operation 0 Not open
0, All Allowed
1, Forbidden U.Price Discount
110 Manual Discount: Forbidden 0~3 0 1
2, Forbidden T.Price Discount
3, Forbidden All Discount
0: no lower limit, discount freely;
Manual Discount: 1~99: Take the percent of U.Price as the lower
111 Lower Limit 0~255 limit of the discount. 0 0
(Percent Number) 100~255: Don’t allow the price after manual
discount is lower than original U.Price.
0: no upper limit, discount freely;
Manual Discount: 1~100: Don’t allow the price after manual
112 Upper Limit 0~255 discount is higher than original U.Price. 0 0
(Percent Number) 101~255: Take the percent of U.Price as the
upper limit of the discount.

78
No. Content Range Remarks Default Permission
113 Percent Discount Arithmetic 0~1 0: Subtracter, 1: Addition 0 1
0: Manual input number
114 Auto Percent Discount Rate 0~99 0 1
1~99: Discount with this number
0: No Auto Discount
1: Price Lock if Auto Discount Is Effective
115 Auto Discount: Price Lock 0~3 2: Price Lock If Auto Discount Is Setting 1 1
3: Price Lock for All PLU
Price Discount disable when price is tracking.
0: No global tax rate
1: Default is exclude Tax with Excluded Rate
116 Global Tax Sort 0~3 1 0
2: Default is include Tax with Excluded Rate
3: Defaultx with included Rate
117 Global tax rate(‱) 0~9999 0.01% tax rate, for 17%, need input 1700 1 0
0: Manual;
118 Amend mode in sale 0~2 1: Record and clear 0 1
2: Not record and clear
0: Not checkout, ignore reduncdance information
119 Scanner checkout 0~2 1: Checkout, ignore reduncdance information 2 1
2: Checkout, not ignore reduncdance information
0: Do nothing
1: Deal with External Barcode (Index mode)
120 Bar code match calculation 0~3 3 1
2: Deal with Internal Barcode (Code mode)
3: Deal with all mode
0: Search user PLU
121 Deal method with code=0 0~2 1: Deal with By-Weight T-Sale PLU 1 1
2: Deal with By-Count T-Sale PLU
Group 1 interior bar code format, if Spec122=0,
122 Internal Barcode 1: Format 0~99 device auto use Spec1 and Spec2 as Group 1 0 0
interior bar code format
Internal Barcode 1: Flag 0~
123 0 0
Number 9999999
124 Internal Barcode 2: Format 0~99 Group 2 interior bar code format 0 1
Internal Barcode 2: Flag 0~
125 0 1
Number 9999999
126 Internal Barcode 3: Format 0~99 Group 3 interior bar code format 0 1
Internal Barcode 3: Flag 0~
127 0 1
Number 9999999
128 Internal Barcode 4: Format 0~99 Group 4 interior bar code format 0 1
Internal Barcode 4: Flag 0~
129 0 1
Number 9999999
Total Price Masked before 0: Not enable
130 0~1 0 1
Printing 1: Enable. Total Price only displays after printing
0: Not enable.
Auto Printing after 1: Auto record after Zero-return. Can press
131 0~4 0 1
Zero-return 【Cancel】to exit, do not record after exit
2: Forced auto record after Zero-return. Force

79
No. Content Range Remarks Default Permission
operator to print the trade or take record.
3: Auto Printing after Zero-return. Can press
【Cancel】to exit, do not record after exit
4: Forced Auto Printing after Zero-return. Force
operator to print the trade or take record.
Accu Mode: Transferring
132 0~1 0 1
PLU by Key Input
Accu Mode: Transferring 0: Disable
133 0~1 1 1
PLU by External Barcode 1: Enable
Accu Mode: Transferring
134 0~1 1 1
PLU by Internal Barcode
0: No salesman mode, log in with salesman 0.
1: Login V1~V4 with Salesman 1~4, No
password
2: Password Enable, V1~V4 by Same Salesman
135 Salesman mode 0~5 3: Password Enable, V1~V4 by Different Salesman 1 0
4: Password Enable, V1~V4 by Same Salesman,
Pass=0 Salesman Cannot login
5: Password Enable, V1~V4 by Different
Salesman, Pass=0 Salesman Cannot login
0: Disable
136 Waiter Mode 0~2 1: Enable, Forbidden dummy personnel 0 1
2: Enable, Allowed dummy personnel
0: Always clear; 1: Memory last one
137 Waiter Memory Mode 0~2 0 1
2: Memory in buffer
138 Right of Default Salesman 0~65535 Please use software 0 1
139 EAN/UCC CRC 0~1 0: Standard, 1: Non-standard 0 1
0: Disable; 1: Half day clear(12:00 and 0:00)
2: Each day clear; 3: Each Saturday clear
140 SID auto clear 0~6 2 1
4: Each Monday clear; 5:Each month clear
6: Each quarter clear
0: Disable(A44 Report Enable)
141 Stock report 0~1 1 1
1: Enable(A44 Report Disable)
0: Only PLU's Unit Allowed
1: Default By-Weight Unit and By-Count Unit
142 Stock change unit mode 0~2 1 1
Allowed
2: All System Unit Allowed
0: Print as number
143 FID/SID Print Mode 0~9 6 1
1~9: Print in specified length with ’#’
144 Each Item has Indentify FID 0~1 0: Forbidden; 1: Enable. 0 1
+1: Print Picture 1; +2: Print global text 0
145 Print extra info in report 0~65535 0 1
+4: Print global text 1; +8……
150 0~255 192 0
When Spec153 is 0, device will connect to
151 0~255 168 0
Scale’s Ethernet IP network by DHCP. Otherwise use appointed IP
152 0~255 0 0
to connect the network
153 0~255 0 0

80
No. Content Range Remarks Default Permission
154 0~255 0 0
155 0~255 When the network under clients 0 0
PC’s Ethernet IP
156 0~255 state( Spec043=2) , appoint PC’s IP. 0 0
157 0~255 0 0
158 0~255 192 0
159 0~255 168 0
Scale’s Ethernet gateway Getway: not use DHCP to connect to network
160 0~255 0 0
161 0~255 1 0
162 0~255 255 0
163 0~255 255 0
Scale’s Ethernet mask Getway: not use DHCP to connect to network
164 0~255 255 0
165 0~255 0 0
166 Scale’s server port 0~65535 33581 1
Do not change such setting unless there are
167 Scale’s clients port 0~65535 33582 1
expert! Irrelevant change will make the network
168 Scale’s UDP local port 0~65535 33583 1
do not work
169 Scale’s UDP remote port 0~65535 33584 1
170 0~255 8 0
171 0~255 8 0
Primary DNS Primary DNS for dns analysis
172 0~255 8 0
173 0~255 8 0
Display and Printing of 0: Dot’.’;
180 0~1 0 2
Radix Point 1: Comma’,’
0: Not printing; 1: Dot’.’;
181 Printing of Kilocharacter 0~3 0 2
2: Comma’,’ 3: Quotation Mark’ '’
182 Display of Kilocharacter 0~1 0: Not display; 1: Display based on Spec181 0 2
185 Unit Printing of Weight 0~1 0: No printing; 1: Printing 0 1
186 Unit Priting of Unit Price 0~1 0: No printing; 1: Printing 0 1
187 Unit Priting of Money 0~1 0: No printing; 1: Printing 0 1
188 Unit Price Length 0~6 0: Use System Length; 1~6: Specified Length 0 1
189 Total Price Length 0~7 0: Use System Length; 1~7: Specified Length 0 1
5-Windows Scale: 0: Auto Fix
190 3 1
PLU Name Display 1: Font 1 Display
0~3
5-Windows Scale: 2: Font 0 Display
191 3 1
AD-Message display 3: 2-Line Mode
5-Windows Scale: 0: Display Time; 1~3: Reserved
192 0~23 3 1
Display in Idle Mode 4~23: Global String data of Scale (0~19)
5-Windows Scale: 0: Display Accumulation Information
193 3 1
Display in accumulated mode 1: Display AD-Message
5-Windows Scale:
194 0~7 0 1
PLU Info Text Source 1 0: PLU Name
5-Windows Scale: 1~7: Text1~7
195 0~7 0 1
PLU Info Text Source 2
Decimal Point of Count In
196 0~5 Similar as spec208 3 1
Barcode Print
197 Fast Track of Weighing 0~4 0: Default level, 1~4: the bigger, the faster 0 1

81
No. Content Range Remarks Default Permission
198 Delay of Zero Judgement 0~19 4 1
100ms per one
199 Delay of Stable Judgement 0~19 0 1
200 Decimal Point: Tare 0~3 In default state, decimal digits of tare. 3 1
201 Decimal Point: Weight 0~3 In default state, decimal digits of weight. 3 1
202 Decimal Point: U.Price 0~5 In default state, decimal digits of U.Price. 2 1
203 Decimal Point: T.Price 0~5 In default state, decimal digits of T.Price. 2 1
204 Decimal Point Fix: Tare 0~1 Fix display decimal point according to Spec200 0 1
205 Decimal Point Fix: Weight 0~1 Fix display decimal point according to Spec201 0 1
Fix display decimal point according to Spec202
206 Decimal Point Fix: U.Price 0~3 0: No Fix; 1: Fix for Discount; 3 1
2: Fix for PLU Call Out; 3: Always Fix.
Fix display decimal point according to Spec203.
207 Decimal Point Fix: T.Price 0~2 0: No Fix; 1: Fix based on Spec100; 1 1
2: Common rounding before fix based on Spec100
Decimal Point of Weight In For number 1.533, if number here is 2, print 153
208 0~5 3 1
Barcode Print when print barcode. If number here is 3, print
1533. The rest may be deduced by analogy.
Decimal Point of Money In
209 0~5 Generally suggest Spec208=Spec201, 2 1
Barcode Print
Spec209=Spec203
0, 1, 2: System Default;
210 T-Sale Unit 0~8 3: kg Unit; 4: g Unit; 0 1
5: ton Unit; 6: lb Unit;
7: 500g Unit; 8: 100g Unit;
211 System U.Price Unit 0~8 There are some relations among 3 units. 0 1
Relations are a little different in different
212 System Weight Unit 0~8 editions because the measuring systems are 3 1
different in different countries.
0: 10g, 3000
TM-30A 1: 5g/10g, 6000/3000
30kg 2: 2g/5g, 15000/6000
3: 1g/2g, 30000/15000
0: 5g, 3000
TM-15A 1: 2g/5g, 7500/3000
15kg 2: 1g/2g, 15000/7500
3: 0.5g/1g, 30000/15000
213 Weight Precision 0~3 1 1
0: 2g, 3000
TM-6A 1: 1g/2g, 6000/3000
6kg 2: 0.5g/1g, 12000/6000
3: 0.2g/0.5g, 30000/12000
Only precisions of unit kg are listed here. Other
units may be a little different. When users use
precisions of 2 or 3, weight print would display
“*” which means it’s only for industrial use.
0: Non-input PLU is by-weight as default
214 Default measure sort 0~1 0 1
1: Non-input PLU is by-count as default
215 Maxium Overflow Degree 0~99 Degree number, there is no limit if number is 0. 9 1

82
No. Content Range Remarks Default Permission
216 Maxium Underflow Degree 0~99 9 1
217 Minium Sale Degree 0~99 4 1
218 Zero Tracking Degree 0~99999 Unit is: e/10 0 2
219 Tare Range 0~99 0 2
220 Range of the Initial Zero 0~99 9 2
Range of the Single Manual
221 0~99 Percentage number. No limit if number is 0. 2 2
Zero
Range of the Accumulative
222 0~99 2 2
Manual Zero
223 Zero Flag Range 0~99 4 2
224 Zero Tracking Range 0~99 Inter-code 5 2
225 Stable Flag Range 0~99 6 2
226 Tare can Overrun Capacity 1 0~1 0: Forbidden; 1: Allowed 0 1
227 Tare Update 0~1 0: Forbidden; 1: Allowed 1 1
Price Convert betweent 0: Allowed; 1: Only Default Weight Allowed
228 0~2 0 1
Different Weight Unit 2: Forbidden
0: Forbidden; 1: Long Press to Switch;
229 Weight Switch 0~2 1 1
2: Single Press to Switch
230 AD Anti-shake while printing 0~7 Hardware parameter 2 1
231 Zero forbidden in PLU Mode 0~1 0: Zero is allowed; 1: Zero is forbidden 0 1
0: Always based on low capability
232 Floating-point of weight 0~2 1: Based on current capability, low is priority 0 1
2: Based on current capability, high is priority
Zero back is necessary for 0: No need
233 0~1 0 1
fast weight unit switch 1: Need
234 Degrees of Zero back 0~31 Judgement Value of Zero back 0 1
235 Power Detect Module 0~1 0: Enable; 1: Disable 0 1
236 Print in Battery Mode 0~1 0: Print; 1: Not print 0 1
237 Interval of Key Scanner 0~4 Hardware parameter 1 1
238 Anti-shake of Key Scanner 0~4 Hardware parameter 1 1
239 Time for open drawer 0~9999 0~9999ms. Default 100ms 100 1
244 Ignore PBS Sensor 0~1 Use to oblige elimate error E7.12 0 1
245 Ignore PDS Sensor 0~1 Use to oblige elimate error E7.11 0 1
246 Ignore PPS Sensor 0~1 Use to oblige elimate error E7.14 0 1
Password is memoried and no need to input
again once it is input. Memory is cleared on
restart or parameter amend.
247 Password hold function 0~3 0: Not hold any password 0 1
1: Only hold drawer password
2: Hold all password except admin password
3: Hold all password
PLU Text Mode: 0: Default
249 PLU Text Length ≈ 0~4 1: 256 Bytes Mode; 2: 512 Bytes Mode 0 1
Total Length-150 3: 1024 Bytes Mode; 4: 2048 Bytes Mode

83
No. Content Range Remarks Default Permission
No-Accumulation Mode
0: Disable this mode
250 【Accu】is Doing Same 0~1 0 1
1: Enable this mode
Operation as【Print】
0: Disable discount menu
251 Discount Menu of Unit Price 0~4 1: Enable, default mode is based on【Key】 0 1
2: Enable, default mode is PERCENT mode
252 Discount Menu of Total Price 0~4 3: Enable, default mode is MINUS mode 0 1
4: Enable, default mode is FIX mode
Call PLU by “Item-Code” 0: Based on PLU number
253 0~1 0 1
when Press 【PLU】 1: Based on PLU Item-Code
0: Disable; 1: Enable in idle mode
254 Auto【PLU】Function 0~3 0 1
2: Enable in PLU mode; 3: Enable in all mode
0: Disable
255 Digit number for auto【PLU】 0~7 0 1
1~7:Auto【PLU】after digtals number inputted
256 Pre-Print Function 0~1 0: Disable; 1: Enable 1 1
Need Admin Password In 0: Normal; +1: Sale; +2: Prog
260 0~31 0 1
Certain Mode +4: Account; +8:【Drawer】; +16: Unit Price
By-Weight PLU Forbidden in 0: Normal
261 +1: Batch Print, 0 1
Certain Mode
0~15 +2:PrePack,
By-Count PLU Forbidden in +4:Lock PLU,
262 0 1
Certain Mode +8:Auto Print
Call PLU automatically in 0~99999 In idle status, device will call specified PLU
263 0 1
Idle status 99 automatically
AUTO MODE transaction +1: Batch Print; +2: Prepack;
264 0~15 0 1
record as “Auto”, not “Sale” +4: Lock PLU; +8: Auto Print
265 Date Print Mode:Month 0~1 0: Digits; 1: Two Characters 0 1
266 Date Display Mode 0~1 0: Default; 1: Using Spec104 and 265 0 1
267 Fast Switch with Weight Unit 0~1 0: Default; 1: Forbidden Non-Standard 0 1
268 Auto Tare Lock 0~1 0: Default; 1: Auto Lock 1 1
269 Print Forbidden 0~1 1: Forbidden Print Model 0 1
0: Disable; 1: Enable if No PLU;
270 Weight Display Hidden 0~2 0 1
2: Enable if No Unit Price
271 Auto Upgrade 0~1 0: Disable; 1: Enable 0 1
0: Mid-Track;
272 Filter Mode 0~2 1: Multi-Average; 0 1
2: Suited-Average
0~99999 999999
274 Maximum PLU Number 0 Means no limit 1
99 4
275 Uniscribe Script 0~2 0: Disable, 1: RTL in LTR, 2: LTR in RTL 0 1
0: Normal; 1: Batch Print; 2: PrePack; 3: Lock
277 Default Working Mode 0~2 0 1
PLU; 4: Auto Print.
278 Hangup Bill Print Format 0~99 0: default; 1~99: specified print format 0 1

84
No. Content Range Remarks Default Permission
0: Forbidden;
1: Only hangup bill can be load once;
279 Hangup and Loadback 0~3 0 1
2: Only hangup bill can be load, no times limit;
3: All bill can be load
280 Salesman authorization 0~1 0: Forbidden; 1: Enable 0 1
282 Payment Operation Forbidden 0~63 0: all enable, 1~63: Please use software 0 1
0: Disable; 1: Record Priced Operation;
283 Record of Unconfirmed Data 0~2 1 1
2: Record Priced/Weighted Operation
287 non-VIP Discount Off 0~99 Percent-Off 0 1
288 VIP Default Discount Off 0~99 0:Same as Spec287, 1~99: Specified Percent Off 0 1
Other Transaction Print
289 0~99 0: Default; 1~99: Specified Pritn Format 0 1
Format
290 Log Text 1 0~14 (Need Special Firmware Version) 0 1
291 Log Text 2 0~14 0: Blank; 1: PLU Name; 2~8: PLU Text1-7; 0 1
292 Log Text 3 0~14 9: Item Code; 10: Index Barcode; 0 1
293 Log Text 4 0~14 11~14: Custom Info 1~4 0 1
0: Auto Clear Custom Info1~4;
294 Keep Custom Info 0~15 +1:Keep Custom Info 1; +2:Keep Custom Info 2 0 1
+4:Keep Custom Info 3; +8:Keep Custom Info 4
297 Second Currency Exchange xxx Please use software 0 1
298 Second Currency Decimal Dot 0~5 Decimal dot position 0 1
0: Default; 1: desk scale;
299 Default stable arithmetic 0~3 0 1
2: platform scale; 3 hanging scale
0: Forbidden
300 Item Service Fee 0~2 1: Allowed, not collect total percent again 0 1
1: Allow, collect total percent again
Item Service Fee: Default 0: Unit price mode; 1: Total price mode;
301 0~2 0 1
Method 2: Percent mode
0: Manual call, manual input price
1: Manual call, manual input percent
Total Service Fee: Input 2: Manual call, take auto price
302 0~5 0 1
Method 3: Manual call, take auto percent
4: Auto call, take auto price
5: Auto call, take auto percent
Under price mode, auto account according to
Total Service Fee: Auto 0~
303 price decimal point 0 1
collect based number 9999999
Under pecent mode: unit is ‱
Service Fee: Percent 0: Based on price before tax
304 0~1 0 1
Collection based Number 1: Based on price after tax
0: No global tax rate
1: Default is exclude Tax with Excluded Rate
305 Tax Sort of Service Fee 0~3 0 1
2: Default is include Tax with Excluded Rate
3: Defaultx with included Rate
306 Tax Rate of Service Fee (‱)0~9999 0.01% tax rate, for 17%, need input 1700 0 1
307 Service Fee Permission 0~1 0: Forbidden, 1: Allowed 1 1
308 Service Fee Re-Input 0~1 0: Forbidden, 1: Allowed 1 1

85
No. Content Range Remarks Default Permission
340 Dot matrix LCD’s contrast 0~7 6 1
Do not change these settings.
341 Dot matrix LCD’s brightness 0~31 7 1
(PTR, parameters setting for network printer)
0 means print according to bill 1 format (once
350 PTR: Item print format 0~99 using bill 1 format, the barcode format and 0 0
signals are all according to bill 1)
351 PTR: Item barcode format 0~99 0 0
0~
352 PTR: Item barcode flag 0 0
9999999
353 PTR: Item print Times 0~99 1 1
354 PTR: Item print Reverse 0~1 0: No Reverse, 1: Print 180°Reversed 0 1
0 means print according to bill 1 format (once
355 PTR: Sum Print Format 0~99 using bill 1 format, the barcode format and 0 0
signals are all according to bill 1)
356 PTR: Sum Barcode Format 0~99 0 0
0~
357 PTR: Sum Barcode Flag 0 0
9999999
358 PTR: Sum Item Print Times 0~99 1 1
359 PTR: Sum Item Print Rol 0~1 0: No Reverse, 1: Print 180°Reversed 0 1
0: Disable
1: Enable, wait till printing finished
360 PTR: network print function 0~3 1 1
2: Enable, wait till printing started
3: Enable, wait till data sending finished
0: No operation
1: Online/offline clew
2: Online/offline clew, alarm when there is no
361 PTR: printer status clew 0~3 1 1
rating printing
3: Online/offline clew, error when there is no
rating printing
PTR: rating number for
362 0~20 Alarm or error if less than rating number 0 1
printer
363 PTR: check interval 0~65535 Unit: second, default for 10s 0 1
364 0~255 0 0
365 0~255 0 0
PTR’s IP: No.1
366 0~255 0 0
367 0~255 0 0
368 0~255 0 0
369 0~255 0 0
PTR’s IP: No.2
370 0~255 0 0
371 0~255 0 0
372 0~255 0 0
373 0~255 0 0
PTR’s IP: No.3
374 0~255 0 0
375 0~255 0 0
376 PTR: Server Socket 0~65535 33591 1

86
No. Content Range Remarks Default Permission
377 PTR: Client Socket 0~65535 Do not change such setting unless there are 33592 1
378 PTR: UDP Local Socket 0~65535 expert! Irrelevant change will make the network 33593 1
379 PTR: UDP Remote Socket 0~65535 printer do not work 33594 1
400 PTR: Print speed decrease 0~99 Reduced % of paper feed speed 0 1
401 PTR: Paper Type 0~1 0: Plain Paper, 1: Gap Paper. 0 0
PTR: Gray Level of Gap
402 0~9 0 is lightest, 9 is darkest. The print color lighter, 7 0
Paper
the damage to print header smaller. Suggest
PTR: Gray Level of Plain
403 0~9 users use lighter grey level. 7 0
Paper
PTR: Plain Paper: Interval of
404 0~99 0 0
Each Print Set the unit of number is mm.
PTR: Plain Paper: Cut-off 0 means use default set
405 0~99 0 0
Position
PTR: Plain Paper: Pre-feed Unit of setting number is dot.
406 0~1999 0 0
Distance Device is reverse feed if number > 1000
407 PTR: Paper width 0~99 0 0
408 PTR: Default font 0~2 1 1
Continuously print appointed time will enter
PTR: Printer over-heat
409 0~30 over-heat protect, Please don’t amend them 0 1
protect
without the guidance of professionals.
Hardware properties. Please don’t amend them
410 PTR: Feed Sensor Position 0~255 180 1
without the guidance of professionals.
PTR: Point numbers for
411 narrow bar in barcode 0~9 0 1
0 for default set, Please don’t amend them
printing
without the guidance of professionals.
PTR: Point numbers for wide
412 0~19 0 1
bar in barcode printing
PTR: Readable character
413 0~2 0 1
fonts in barcode printing
415 PTR: Auto new line mode 0~1 0: One line mode; 1: Auto new line mode 0 1
PTR: ITF25 barcode frame 0: No frame; 1: Up and Down frame;
416 0~2 1 1
mode 2: Around frame
PTR: ITF25 barcode frame
417 0~31 Frame dots 8 1
width
PTR: ITF25 barcode left and
418 0~31 Left and right blank dots 20 1
right blank width
PTR: Gap Paper: Pre-feed Unit of setting number is dot.
419 0~1999 0 0
Distance Device is reverse feed if number > 1000
420 PTR: Ignore PBS Sensor 0~1 Use to force remove error E6.12 0 1
421 PTR: Ignore PDS Sensor 0~1 Use to force remove error E6.11 0 1
422 PTR: Ignore PPS Sensor 0~1 Use to force remove error E6.14 0 1
450 PDF417: Checksum Level 0~9 0~8: Fix level; 9: System default level 9 1
451 PDF417: Columns Number 0~30 0: Auto sizing, 1~30: Fix number 0 1
452 PDF417: Rows Number 0~90 0~2: Auto sizing, 3~90: Fix number 0 1
453 PDF417: Bar Width 0~6 0: Default 3 0 1
454 PDF417: Bar Height 0~18 0: Default 6 0 1

87
No. Content Range Remarks Default Permission
455 QR: Check Level 0~3 1 1
456 QR: Version 0~31 QR Minimum Version 0 1
457 QR: Bar Size 0~6 0: Default=3 0 1
480 Custom Version Reserved
~499 Spec

7.3 Definitions of String data paremeters


Number Hint Text content Default print format
0 ShopN Store Name Print: header center
1 ScaleN Device Name Not use
2 MnyPre Prefix of Money Unit
3 MnySuf Suffix of Money Unit
4 Strg-1 Bill text 1 Print: header center
5 Strg-2 Bill text 2 Print: header left
6 Strg-3 Bill text 3 Print: header center
7 Strg-4 Bill text 4 Print: header left
8 Strg-5 Bill text 5 Print: end center
9 Strg-6 Bill text 6 Print: end left
10 Strg-7 Bill text 7 Print: end center
11 Strg-8 Bill text 8 Print: end left
12 Spst-1 Special text 1 Reserved
13 Spst-2 Special text 2 Reserved
14 Ind-MK Industry Mark Industry Mark
15 W-SSID Wireless SSID Wireless SSID
16 W-PASS Wireless Password Wireless Password
17 Spst-6 Special text 6 Reserved
18 Spst-7 Special text 7 Reserved
19 Spst-8 Special text 8 Reserved

7.4 Definitions of Shortcut Function Key


1 Number:0 2 Number:1 3 Number:2 4 Number:3 5 Number:4 6 Number:5
7 Number:6 8 Number:7 9 Number:8 10 Number:9 11 Number:00 12 Clear
13 Cancel 14 Accu/Confirm 15 Cash/Print 16 PLU 17 F-Prog 18 V1
19 V2 20 V3 21 V4 22 Amend 23 × 24 Feed
25 SetZero 26 SetTare 27 Sale 28 Prog 29 Account 30 Time
31 -% 32 -Num 33 @Price 34 TSale 35 CashBox 38 Manual Weight
39 Paper Type 40 Pre/Re Print 41 Shift 44 Print2 45 CCard 46 MoveDot
47 U.W. Sample 48 Weight Accu 49 Division 50 UnitChange 51 Lock Tare 52 Auto Mode
53 Normal Mode 54 Batch Mode 55 PrePack Mode 56 LockPLU Mode 57 AutoPrint Mode 58 Service Fee
59 ←V→ 60 Mode 62 On/Off 63 PayOther-0 64 PayOther-1 65 PayOther-2
66 VIP 67 Other Transactions 76 Custom Info 1 77 Custom Info 2 78 Custom Info 3 79 Custom Info 4

88

You might also like