STANDARD FOUNDATIONS FOR METEOROLOGY TOWERS

CARL C. A/S - MET-SERIES - EUROCODE OVERVIEW


Rev. date 16.02.2005

SOIL
Foundation bolts height over concrete = h
Assumption on soil bearing capacity See bolt template drawing.
below foundation level. Future terrain
The following demands are min. requirements. level

200

h
Bad soil conditions:
Sand or gravel: fi > 28°

1200
or clay: Cv > 60 kN/m² 1 3

1500
Filling soil: Density > 16/8 kN/m³
2

1800
Good soil conditions: 4 5
Sand or gravel: fi > 35° 500 6
or clay: Cv > 135 kN/m²
500

Filling soil: Density > 18/10 kN/m³

Ground water level (GWL)


50-100

Type 1: GWL below foundation level 700 CONCRETE CARPET LAYER


Type 2: GWL at terrain VERTICAL SECTION Concrete grade 5 MPa

Soil conditions on site has to be checked


by a geological competent person.
Conditions can be checked visually and DS
compared to those expected in the
neighbourhood.

CONCRETE
The followind demands defines
the concrete:

0,58a
Min. cylinder strength: 30 MPa.
Enviroment class: Moderate
Control class: Normal
Max. gravel size: 32 mm.

0,29a
Min. concrete layer: 50 mm.

A vibrator must be used during concreting.


REINFORCEMENT
a
Only rib bar steel is used. Tower system
Yield stress > 550 N/mm².
Reinforcement is listed in the enclosed form
refering to positions in the drawings.
Reinforcement is tied up in every second cross point.
(no welding on reinforcement).

FOUNDATION BOLTS
Delivered by Carl C. A/S and mounted on PLAN
templet to ensure correct placement.
L1/L3 (GWL below foundation level)
REMARKS
L2/L4 (GWL at terrain)
All measurement are in mm.

Filling around and over the foundation must


take place before tower erection.

The foundation is calculated for loading, similar


to max. utilization of the tower bottom section.
CALCULATION

Loads on top of foundation according to


Eurocode.

TO BE USED AS GUIDING PRINCIPLES ONLY.


STANDARD FOUNDATIONS FOR METEOROLOGY TOWERS
CARL C. A/S - MET-SERIES DIMENSION TABLE
Rev. date 16.02.2005

Bad soil conditions Good soil conditions

Foundation Tower Plate(-GWL) Plate(+GWL) Plate(-GWL) Plate(+GWL) Pedestal Reinforcement


number a (mm) L1(mm) L2(mm) L3(mm) L4(mm) DS(mm) 1 2 3 4
F.MET314 4580 9600 11300 8900 10400 1000 Y16/250 Y25/200 24 Y25 10 Y12
F.MET314,1 4260 9500 11400 8700 10400 1000 Y16/250 Y25/200 24 Y25 10 Y12
F.MET313 3940 8600 10300 7900 9400 1000 Y16/250 Y25/200 20 Y25 10 Y12

F.MET313,1 3620 8400 10000 7700 9100 1000 Y16/250 Y25/200 20 Y25 10 Y12
F.MET312 3300 8200 9700 7500 8900 1000 Y16/250 Y25/200 20 Y25 10 Y12
F.MET312,1 2980 8000 9400 7300 8600 1000 Y16/250 Y25/200 20 Y25 10 Y12
F.MET311 2660 7100 8300 6500 7600 1000 Y16/250 Y25/250 17 Y25 10 Y12
F.MET311,1 2340 6900 8000 6300 7300 1000 Y16/250 Y25/250 17 Y25 10 Y12
F.MET310 2020 6300 7200 5700 6600 1000 Y16/250 Y20/250 14 Y25 10 Y12

F.MET310,1 1900 6200 7200 5600 6600 1000 Y16/250 Y20/250 14 Y25 10 Y12
F.MET309 1780 5500 6300 4900 5700 1000 Y16/250 Y20/250 17 Y20 10 Y12
F.MET309,1 1660 5400 6200 4900 5700 1000 Y16/250 Y20/250 17 Y20 10 Y12
F.MET308 1540 4800 5500 4300 5000 1000 Y16/250 Y20/250 12 Y20 10 Y12
F.MET308,1 1420 4800 5500 4300 5000 1000 Y16/250 Y20/250 12 Y20 10 Y12

F.MET307 1300 4100 4800 3800 4400 1000 Y16/250 Y20/250 9 Y20 10 Y12
F.MET306 1150 3300 4000 3100 3600 1000 Y16/250 Y20/250 9 Y16 10 Y12
F.MET305 1000 2700 3300 2600 2900 1000 Y16/250 Y20/250 7 Y16 10 Y12
F.MET304 850 2100 2600 2100 2400 1000 Y16/250 Y20/250 4 Y16 10 Y12
F.MET303 700 2000 2500 2000 2300 1000 Y16/250 Y20/250 4 Y16 10 Y12
F.MET302 550 1500 1800 1500 1800 1000 Y16/250 Y20/250 4 Y16 10 Y12

F.MET301 400 1200 1300 1100 1300 1000 Y16/250 Y20/250 4 Y16 10 Y12

5 Hoops as necessary to support


the top reinforcement layer
6 Hoops Y16/500 mm

REMARKS
All measurement are mm.
The dimensions are valid for a foundation with
max. utilization of the tower bottom section.

TO BE USED AS GUIDING PRINCIPLES ONLY.


Case 018-05
Date 15-06-2005

STANDARD FOUNDATION FOR METEOROLOGY TOWERS


CARL C A/S - MET-SERIES REINFORCEMENT LIST

Foundation Pos. Foundation type L1 Foundation type L2 Foundation type L3 Foundation type L4
number No and Length No and Length No and Length No and Length
type la (mm) type la (mm) type la (mm) type la (mm)
F-MET-314 38 x Y16 9500 45 x Y16 11200 36 x Y16 8800 42 x Y16 10300
F-MET-314.1 38 x Y16 9400 46 x Y16 11300 35 x Y16 8600 42 x Y16 10300
F-MET-313 34 x Y16 8500 41 x Y16 10200 32 x Y16 7800 38 x Y16 9300
F-MET-313.1 34 x Y16 8300 40 x Y16 9900 31 x Y16 7600 36 x Y16 9000
F-MET-312 33 x Y16 8100 39 x Y16 9600 30 x Y16 7400 36 x Y16 8800
F-MET-312.1 32 x Y16 7900 38 x Y16 9300 29 x Y16 7200 34 x Y16 8500
F-MET-311 28 x Y16 7000 33 x Y16 8200 26 x Y16 6400 30 x Y16 7500
F-MET-311.1 28 x Y16 6800 32 x Y16 7900 25 x Y16 6200 29 x Y16 7200
F-MET-310 25 x Y16 6200 29 x Y16 7100 23 x Y16 5600 26 x Y16 6500
F-MET-310.1 25 x Y16 6100 29 x Y16 7100 22 x Y16 5500 26 x Y16 6500
F-MET-309
F-MET-309.1
➀ 22 x Y16
22 x Y16
5400
5300
25 x Y16
25 x Y16
6200
6100
20 x Y16
20 x Y16
4800
4800
23 x Y16
23 x Y16
5600
5600
F-MET-308 19 x Y16 4700 22 x Y16 5400 17 x Y16 4200 20 x Y16 4900
F-MET-308.1 19 x Y16 4700 22 x Y16 5400 17 x Y16 4200 20 x Y16 4900
F-MET-307 16 x Y16 4000 19 x Y16 4700 15 x Y16 3700 18 x Y16 4300
F-MET-306 13 x Y16 3200 16 x Y16 3900 12 x Y16 3000 14 x Y16 3500
F-MET-305 11 x Y16 2600 13 x Y16 3200 10 x Y16 2500 12 x Y16 2800
F-MET-304 8 x Y16 2000 10 x Y16 2500 8 x Y16 2000 10 x Y16 2300
F-MET-303 8 x Y16 1900 10 x Y16 2400 8 x Y16 1900 9 x Y16 2200
F-MET-302 6 x Y16 1400 7 x Y16 1700 6 x Y16 1400 7 x Y16 1700
F-MET-301 5 x Y16 1100 5 x Y16 1200 4 x Y16 1000 5 x Y16 1200

Foundation Pos. Foundation type L1 Foundation type L2 Foundation type L3 Foundation type L4
number No and Length No and Length No and Length No and Length
type la (mm) type la (mm) type la (mm) type la (mm)
F-MET-314 48 x Y25 9500 57 x Y25 11200 45 x Y25 8800 52 x Y25 10300
F-MET-314.1 48 x Y25 9400 57 x Y25 11300 44 x Y25 8600 52 x Y25 10300
F-MET-313 43 x Y25 8500 52 x Y25 10200 40 x Y25 7800 47 x Y25 9300
F-MET-313.1 42 x Y25 8300 50 x Y25 9900 39 x Y25 7600 46 x Y25 9000
F-MET-312 41 x Y25 8100 49 x Y25 9600 38 x Y25 7400 45 x Y25 8800
F-MET-312.1 40 x Y25 7900 47 x Y25 9300 37 x Y25 7200 43 x Y25 8500
F-MET-311 28 x Y25 7000 33 x Y25 8200 26 x Y25 6400 30 x Y25 7500
F-MET-311.1 28 x Y25 6800 32 x Y25 7900 25 x Y25 6200 29 x Y25 7200
F-MET-310 25 x Y20 6200 29 x Y20 7100 23 x Y20 5600 26 x Y20 6500
F-MET-310.1 25 x Y20 6100 29 x Y20 7100 22 x Y20 5500 26 x Y20 6500
F-MET-309
F-MET-309.1
② 22 x Y20
22 x Y20
5400
5300
25 x Y20
25 x Y20
6200
6100
20 x Y20
20 x Y20
4800
4800
23 x Y20
23 x Y20
5600
5600
F-MET-308 19 x Y20 4700 22 x Y20 5400 17 x Y20 4200 20 x Y20 4900
F-MET-308.1 19 x Y20 4700 22 x Y20 5400 17 x Y20 4200 20 x Y20 4900
F-MET-307 16 x Y20 4000 19 x Y20 4700 15 x Y20 3700 18 x Y20 4300
F-MET-306 13 x Y20 3200 16 x Y20 3900 12 x Y20 3000 14 x Y20 3500
F-MET-305 11 x Y20 2600 13 x Y20 3200 10 x Y20 2500 12 x Y20 2800
F-MET-304 8 x Y20 2000 10 x Y20 2500 8 x Y20 2000 10 x Y20 2300
F-MET-303 8 x Y20 1900 10 x Y20 2400 8 x Y20 1900 9 x Y20 2200
F-MET-302 6 x Y20 1400 7 x Y20 1700 6 x Y20 1400 7 x Y20 1700
F-MET-301 5 x Y20 1100 5 x Y20 1200 4 x Y20 1000 5 x Y20 1200

Page 1 of 3

TO BE USED AS GUIDING PRINCIPLES ONLY.


Case 018-05
Date 15-06-2005

STANDARD FOUNDATION FOR METEOROLOGY TOWERS


CARL C A/S - MET-SERIES REINFORCEMENT LIST

Foundation Pos. Foundation type L1 Foundation type L2 Foundation type L3 Foundation type L4
number No and Height No and Height No and Height No and height
type ha (mm) type ha (mm) type ha (mm) type ha (mm)
F-MET-314 24 x Y25 1825 24 x Y25 1825 24 x Y25 1825 24 x Y25 1825
F-MET-314.1 24 x Y25 1825 24 x Y25 1825 24 x Y25 1825 24 x Y25 1825
F-MET-313 20 x Y25 1825 20 x Y25 1825 20 x Y25 1825 20 x Y25 1825
F-MET-313.1 20 x Y25 1825 20 x Y25 1825 20 x Y25 1825 20 x Y25 1825
F-MET-312 20 x Y25 1825 20 x Y25 1825 20 x Y25 1825 20 x Y25 1825
F-MET-312.1 20 x Y25 1825 20 x Y25 1825 20 x Y25 1825 20 x Y25 1825
F-MET-311 17 x Y25 1825 17 x Y25 1825 17 x Y25 1825 17 x Y25 1825
F-MET-311.1 17 x Y25 1825 17 x Y25 1825 17 x Y25 1825 17 x Y25 1825
F-MET-310 14 x Y25 1825 14 x Y25 1825 14 x Y25 1825 14 x Y25 1825
F-MET-310.1 14 x Y25 1825 14 x Y25 1825 14 x Y25 1825 14 x Y25 1825
F-MET-309
F-MET-309.1
③ 17 x Y20
17 x Y20
1825
1825
17 x Y20
17 x Y20
1825
1825
17 x Y20
17 x Y20
1825
1825
17 x Y20
17 x Y20
1825
1825
F-MET-308 12 x Y20 1825 12 x Y20 1825 12 x Y20 1825 12 x Y20 1825
F-MET-308.1 12 x Y20 1825 12 x Y20 1825 12 x Y20 1825 12 x Y20 1825
F-MET-307 9 x Y20 1825 9 x Y20 1825 9 x Y20 1825 9 x Y20 1825
F-MET-306 9 x Y16 1825 9 x Y16 1825 9 x Y16 1825 9 x Y16 1825
F-MET-305 7 x Y16 1825 7 x Y16 1825 7 x Y16 1825 7 x Y16 1825
F-MET-304 4 x Y16 1825 4 x Y16 1825 4 x Y16 1825 4 x Y16 1825
F-MET-303 4 x Y16 1825 4 x Y16 1825 4 x Y16 1825 4 x Y16 1825
F-MET-302 4 x Y16 1825 4 x Y16 1825 4 x Y16 1825 4 x Y16 1825
F-MET-301 4 x Y16 1825 4 x Y16 1825 4 x Y16 1825 4 x Y16 1825

Foundation Pos. Foundation type L1 Foundation type L2 Foundation type L3 Foundation type L4
number No and Width No and Width No and Width No and Width
type ba (mm) type ba (mm) type ba (mm) type ba (mm)
F-MET-314 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-314.1 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-313 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-313.1 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-312 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-312.1 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-311 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-311.1 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-310 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-310.1 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-309
F-MET-309.1
④ 10 x Y12
10 x Y12
880
880
10 x Y12
10 x Y12
880
880
10 x Y12
10 x Y12
880
880
10 x Y12
10 x Y12
880
880
F-MET-308 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-308.1 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-307 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-306 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-305 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-304 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-303 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-302 10 x Y12 880 10 x Y12 880 10 x Y12 880 10 x Y12 880
F-MET-301 10 x Y12 880 10 x Y12 881 10 x Y12 882 10 x Y12 883

Page 2 of 3

TO BE USED AS GUIDING PRINCIPLES ONLY.


Case 018-05
Date 15-06-2005

STANDARD FOUNDATION FOR METEOROLOGY TOWERS


CARL C A/S - MET-SERIES REINFORCEMENT LIST

Foundation Pos. Foundation type L1 Foundation type L2 Foundation type L3 Foundation type L4
number No and Height No and Height No and Height No and Height
type sa (mm) type sa (mm) type sa (mm) type sa (mm)
F-MET-314 46 x Y12 310 64 x Y12 310 40 x Y12 310 54 x Y12 310
F-MET-314.1 45 x Y12 310 65 x Y12 310 38 x Y12 310 54 x Y12 310
F-MET-313 37 x Y12 310 53 x Y12 310 31 x Y12 310 44 x Y12 310
F-MET-313.1 35 x Y12 310 50 x Y12 310 30 x Y12 310 41 x Y12 310
F-MET-312 34 x Y12 310 47 x Y12 310 28 x Y12 310 40 x Y12 310
F-MET-312.1 32 x Y12 310 44 x Y12 310 27 x Y12 310 37 x Y12 310
F-MET-311 25 x Y12 310 34 x Y12 310 21 x Y12 310 29 x Y12 310
F-MET-311.1 24 x Y12 310 32 x Y12 310 20 x Y12 310 27 x Y12 310
F-MET-310 20 x Y12 310 26 x Y12 310 16 x Y12 310 22 x Y12 310
F-MET-310.1 19 x Y12 310 26 x Y12 310 16 x Y12 310 22 x Y12 310
F-MET-309
F-MET-309.1
⑤ 15 x Y12
15 x Y12
310
310
20 x Y12
19 x Y12
310
310
12 x Y12
12 x Y12
310
310
16 x Y12
16 x Y12
310
310
F-MET-308 12 x Y12 310 15 x Y12 310 9 x Y12 310 13 x Y12 310
F-MET-308.1 12 x Y12 310 15 x Y12 310 9 x Y12 310 13 x Y12 310
F-MET-307 8 x Y12 310 12 x Y12 310 7 x Y12 310 10 x Y12 310
F-MET-306 5 x Y12 310 8 x Y12 310 5 x Y12 310 6 x Y12 310
F-MET-305 4 x Y12 310 5 x Y12 310 3 x Y12 310 4 x Y12 310
F-MET-304 2 x Y12 310 3 x Y12 310 2 x Y12 310 3 x Y12 310
F-MET-303 2 x Y12 310 3 x Y12 310 2 x Y12 310 3 x Y12 310
F-MET-302 1 x Y12 310 2 x Y12 310 1 x Y12 310 2 x Y12 310
F-MET-301 1 x Y12 310 1 x Y12 310 1 x Y12 310 1 x Y12 310

Foundation Pos. Foundation type L1 Foundation type L2 Foundation type L3 Foundation type L4
number No and Height No and Height No and Height No and Height
type sa (mm) type sa (mm) type sa (mm) type sa (mm)
F-MET-314 72 x Y16 310 88 x Y16 310 68 x Y16 310 80 x Y16 310
F-MET-314.1 72 x Y16 310 88 x Y16 310 64 x Y16 310 80 x Y16 310
F-MET-313 64 x Y16 310 80 x Y16 310 60 x Y16 310 72 x Y16 310
F-MET-313.1 64 x Y16 310 76 x Y16 310 56 x Y16 310 68 x Y16 310
F-MET-312 60 x Y16 310 72 x Y16 310 56 x Y16 310 68 x Y16 310
F-MET-312.1 60 x Y16 310 72 x Y16 310 56 x Y16 310 64 x Y16 310
F-MET-311 52 x Y16 310 64 x Y16 310 48 x Y16 310 56 x Y16 310
F-MET-311.1 52 x Y16 310 60 x Y16 310 48 x Y16 310 56 x Y16 310
F-MET-310 48 x Y16 310 52 x Y16 310 40 x Y16 310 48 x Y16 310
F-MET-310.1 44 x Y16 310 52 x Y16 310 40 x Y16 310 48 x Y16 310
F-MET-309
F-MET-309.1
⑥ 40 x Y16
40 x Y16
310
310
48 x Y16
44 x Y16
310
310
36 x Y16
36 x Y16
310
310
40 x Y16
40 x Y16
310
310
F-MET-308 36 x Y16 310 40 x Y16 310 32 x Y16 310 36 x Y16 310
F-MET-308.1 36 x Y16 310 40 x Y16 310 32 x Y16 310 36 x Y16 310
F-MET-307 28 x Y16 310 36 x Y16 310 28 x Y16 310 32 x Y16 310
F-MET-306 24 x Y16 310 28 x Y16 310 20 x Y16 310 24 x Y16 310
F-MET-305 16 x Y16 310 24 x Y16 310 16 x Y16 310 20 x Y16 310
F-MET-304 12 x Y16 310 16 x Y16 310 12 x Y16 310 16 x Y16 310
F-MET-303 12 x Y16 310 16 x Y16 310 12 x Y16 310 16 x Y16 310
F-MET-302 8 x Y16 310 12 x Y16 310 8 x Y16 310 12 x Y16 310
F-MET-301 4 x Y16 310 8 x Y16 310 4 x Y16 310 8 x Y16 310