Product Release Letter

AVEVA Everything3D™ 2.1.0 Fix.6


Partial Fix Release 52541
Windows 7 / Windows 8.1
This letter introduces and describes this release, which is supported on the indicated platform(s).

This Release Contains


A partial release of AVEVA Everything3D™, which upgrades the full release 52421 AVEVA Everything3D™
2.1.0.
The separately licensed products or product components installable from or upgraded by this release are as
follows:
Product Core
Product Code Product Name
Version Version
V00FN201 AVEVA Everything3D™ 2.1.0 1.2.2
V00FN232 AVEVA Catalogue™ 2.1.0 1.2.2

Prerequisite for this Release (Operating System)


A 64 bit operating system is required for the installation of AVEVA Everything3D™ 2.1.0 and for the
visualisation and use of laser data in the application.

 Windows® 7 Professional or Enterprise + Service Pack 1*1.


 Windows Server 2008 R2 + Service Pack 1.
Required Operating System  Windows® 8.1*2.
 Windows Server 2012 R2.
 Microsoft .NET Framework 4.0 (supplied)*3.

Build Operating System  Windows Server 2008 R2 + Service Pack 1.

*1 Please note that a Windows Platform Update (Windows 7 SP1 and Windows Server 2008 R2 SP1) is a pre-requisite for accurate 2D rendering (for
example Text graphics) in the 3D canvas (http://support.microsoft.com/kb/2670838 ).
*2 AVEVA does not support the installation of AVEVA E3D 2.1 software and\or Projects on to disk volumes with Short\8.3 file name format disabled.
Please ensure that Short\8.3 file name format is enabled on all relevant volumes before installation. Please refer to Knowledge Base item 5702 for
further details.
*3 AVEVA E3D 2.1.0 has been tested with Microsoft .NET Framework 4.0 with the following fix: http://www.microsoft.com/en-
us/download/details.aspx?id=3556. This fix is mandatory for the use of the Design in Context Feature.
Microsoft .NET Framework 4.5 Fix 2 has been tested with AVEVA E3D 2.1.0. The fix release is required to ensure the correct visualisation of the
AVEVA E3D Draw 2.1.0 print dialog.

For further information please contact your local AVEVA support office, which can be found at support.aveva.com

This document has been prepared and approved by the following:


Job Title Name
Deputy Head of Product Stephen Burrows
Test Manager Vaseem Jameel
Head of Product Neale Morris
TPS Manager Semra Hamitogullari

File: d52541
Last saved: 6-Oct-2016  Copyright 2016 AVEVA Solutions Limited Page 1 of 37
Product Release Letter
Please note that recommended/supported hardware and software configurations are constantly subject to
review; please consult the AVEVA support web pages for the latest recommendations.

Prerequisite for this Release (Products)


AVEVA Licensing™
 AVEVA Licensing 2.0.0 or later and an appropriate License File.
Notes:
1. AVEVA Everything3D™ does NOT work with AVEVA Flexman.
2. If upgrading from AVEVA Licensing System 1.1.1, please install Fix release 1.1.1.3 in order to correct
an uninstall defect in that release. Once this has been done version 1.1.1.3 can be uninstalled and
replaced with later versions.

AVEVA Client Cache Service™


 To ensure the performance benefits presented by the AVEVA Cache Service, which is installed with
AVEVA Everything3D™, Microsoft Message Queuing (MSMQ) must be enabled. This is achieved using
the Windows Components feature of Windows Control Panel > Add or Remove Programs.
For full details, please refer to the AVEVA Everything3D™ 2.1.0 Installation Guide.

Microsoft® Software
 AVEVA E3D 2.1.0 has been verified with Microsoft® Office 365.
 Microsoft Office 2010 (and later) is required for some functions:
1. Optimum operation of the AVEVA Design Platform GUI requires Arial Unicode MS font, supplied with
Microsoft Office and also with Microsoft Office Visio.
2. Microsoft Office Excel import requires “.NET Programmability Support” enabled when Office is
installed. This can be found under “Advanced customization of applications” and installs the
Microsoft.Office.Interop.Excel.dll; without this, Excel import will not work.
 Microsoft Office Visio 2010 (Standard edition, 32-bit) is required for AVEVA Schematic Model Viewer.

Compatibility

For full compatibility details, and for information about AVEVA E3D 2.1.0 compatibility with any later
versions, please refer to the compatibility matrix.

A full and up to date compatibility matrix can be found at compatibility.aveva.com/matrix.

The following AVEVA products are compatible with AVEVA Everything3D™ 2.1.0.

 AVEVA Administration™ 1.4.0 (Fix Release 4).


Note: This release supersedes all previous AVEVA Administration versions delivered with other AVEVA
products.
 AVEVA Applications Service™ 2.1.0.
Note: For customers who use AVEVA E3D Insight™ 2.1.0: AVEVA Applications Service 2.1.0 or higher
must be used. Earlier versions are incompatible.
 AVEVA Bocad™ 2.2.1 & 2.3.0.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 2 of 37


Product Release Letter
 AVEVA Catalogue™ 2.1.0.
 AVEVA Client Cache Service™ 1.0.5.
 AVEVA Clash Manager™ 14.1.0.
 AVEVA Design Checker™ 1.1.0.
 AVEVA Diagrams™ 14.1.0 (Fix Release 4).
 AVEVA E3D Documentation™ 2.1.0.
 AVEVA Electrical™ 12.1.3 (Fix Release 8).
 AVEVA Engineering™ 14.1.1 (Fix Release 4).
 AVEVA Global Server™ 3.2.1 (Fix Release 1).
Note: Includes separately licensed products AVEVA Global Hub and AVEVA Global Satellite.
 AVEVA Hull & Outfitting™ 12.1.4 & associated products (Fix Release 34).
 AVEVA Instrumentation™ 12.1.3 (Fix Release 6).
 AVEVA Integration Service 1.3.0.
Note: This is the primary route for compatibility with AVEVA P&ID™ 12.1.2 (Fix Release 9). The service
also supports compatibility with AVEVA Electrical™ 12.1.3 and AVEVA Instrumentation™ 12.1.3.
 AVEVA NET Workhub & Dashboard™ 5.0.2 or lower.
 AVEVA PDMS™ 12.1.4 & associated products (Fix Release 34).
 AVEVA PDMS-VPRM Gateway™ 5.6.0.
 AVEVA Plot Utilities™ 12.1.5.
 AVEVA Pipe Stress Interface™ 2.1.0.1
 AVEVA PML Publisher™ 2.2.0
 AVEVA Review™ 12.2.0 (Fix Release 10).
 AVEVA Shared Services™ 3.3.0.
 AVEVA Structural Analysis Interface - SP™ 3.1.0

The following LFM products are compatible with AVEVA Everything3D™ 2.1.0:
 LFM Server™ 4.4.0.

Supersedes
This release supersedes Release 52531– AVEVA Everything3D™ 2.1.0.5.

Install
Please download the release (52541.zip) and run the product install (Folder E3D2106, E3D2.1.0.6.exe)
following the instructions.

Sample Data
Sample projects are available here: AVEVA Everything3D™ - Projects.
The AVEVA sample projects are regularly revised and have been updated with AVEVA E3D – Projects 2.1.0
Fix.4 being released to provide sample data for the Terrain application and Supports features available in the

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 3 of 37


Product Release Letter
AVEVA E3D 2.1.0 Fix.5 release. Please check the AVEVA Support Site (AVEVA Everything3D™ Fix Release
History) frequently for updates.
AVEVA Laser Sample Data 1.1 is available for use with AVEVA E3D 2.1.0 for the purpose of familiarisation
with the extensive laser functionality available, including the new AVEVA HyperBubble™ technology. The
data may be downloaded here: AVEVA Laser Sample Data.

Documentation
The AVEVA E3D 2.1.0 documentation includes the AVEVA Administration, AVEVA Catalogue and AVEVA
Global product user guides.
Documentation is available online so that it may be continually updated and remain current for any new
functionality introduced through the life of the product. AVEVA Documentation 2.1.0 may also be
downloaded separately for local installation here: AVEVA Documentation 2.1.0.

First Release
This product release is first available on the AVEVA support website support.aveva.com as AVEVA
Everything3D™ 2.1.0.6, release number 52541.

List of Enhancements
AVEVA Everything3D™ (E3D™) is the primary 3D design product from AVEVA covering the needs of Plant
industries. The release also introduces the capability to interact with Hull models produced in AVEVA Marine.

AVEVA E3D 2.1.0 provides a platform to enable lean construction principles to be adopted, increasing quality
and speed of execution throughout the entire project. This is achieved through advanced usability for all
design tasks, improving productivity by utilising latest technologies and best in class User Experience to
enable innovative and ever more efficient project execution processes.

The product includes optimal integration with AVEVA Engineering & Schematics and new innovation with
Laser data, utilising the Living Point Cloud capability of AVEVA HyperBubble™. Powerful 2D drafting also
allows the inclusion of Laser data, driving down the need to remodel existing Digital Assets.

The AVEVA E3D 2.1.0 release includes the following general functional enhancements:

 General Model Interactions e.g. the PowerWheel, PowerCompass and Properties Grid.

 A new Structural application (Sections and Plates).

 A new Supports application.

 Improved integration of Laser Data, including the introduction of the HyperBubble™


technology and the ability to included Laser data in Drawings.

 Integration with AVEVA NET™ through the Design in Context feature.

 Visualisation of Hull Data in Model and Draw modules.

 General Draw Improvements (incl. Hull Symbolic Views).

 Integration with AVEVA E3D Insight™ and the ability to Comment a design.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 4 of 37


Product Release Letter
 Piping Improvements (incl. Integrator & Sloping Pipes).

 Please refer to the AVEVA Everything3D™ 2.1.0 User Bulletin for extensive information on features introduced at
AVEVA E3D 2.1.0.

 Where migrating to AVEVA E3D 2.1 from AVEVA PDMS or Hull & Outfitting 12.1.SP4 please consult the AVEVA
Everything3D™ 2.1.0 Migration & Interoperability Guide for guidance on specific data considerations.

This fix release includes the following functional enhancements:


Trunnion Dimensions in IsoDraft
AVEVA E3D 2.1 Fix.6 introduces a centreline dimension for Elbow Trunnions complete with annotation to
avoid fabrication errors. This has been achieved by a modification to the TRREDU Transfer file.

SpaceMouse Support
This release introduces support for a 3D SpaceMouse®(3Dconnexion) to enable navigation in the 3D View of
the Model and Draw modules (the mouse may only be used for navigation purposes).
Please note: the provided capability is not currently compatible with the 3Dconnexion software 3DxWare®
where settings have been applied for AVEVA E3D 2.1. Users are advised to ensure that any previously set
options are deactivated (as per the default state).

Consolidated from previous fix releases:

AVEVA Everything3D 2.1.0.5, Release No. 52531.

Terrain Application.

AVEVA E3D 2.1 Fix.5 introduces the Terrain application within the Model module. The Terrain tab is prompted
via the selection of Terrain from the Discipline options list and facilitates the definition, modelling and
modification of terrain data.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 5 of 37


Product Release Letter

 AVEVA E3D – Projects 2.1.0 Fix.4 provides sample data for the new Terrain application.

The creation and modification of a Terrain Definition and


associated Terrain Model is guided by an intuitive user
interface that steps the user through the required design
stages.

 Terrain Surface

A terrain surface is imported and created by the Import (IMP) command and is formed by a Terrain
Surface (TRNSUR) with a GENPRI holding the imported geometry.

 The following import formats are supported initially: IGES, STEP, STL and XYZ.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 6 of 37


Product Release Letter
 Terrain Definition

A Terrain Definition (TRNDEF) is used to define a terrain and may be restricted to a specific area of the
imported Terrain Surface by a rectangular restriction (TRNRR). In addition, standard primitives and
negatives (stored below a Terrain Primitive element TRNPRI) can be used to add or remove material
from the terrain model at creation or as a modification.

The resulting Terrain Solid (TRNSLD) is formed from the Terrain Definition with the terrain geometry
stored as a GENPRI.

 Terrain Model

With reference to a Terrain Definition (TRNREF), the Terrain Model (TRNMOD) is used by Model users
during design activity.

Each Terrain Model can be further split by a cell structure that is defined by a collection of dividing
planes obtained from a Reference Grid (REFGRD).

 Terrain Model (Contours)

Terrain Contours are associated to a Terrain Model with sets of contours (TRNCLS) holding groups of
contours (TRNCLG) at the same height.

To enable contours to be added to the Drawlist for a given terrain cell, a terrain curve collection
(TRNCUC) groups all curves that belongs to a cell and in turn contains a terrain curve set (TRNCUS) that
groups all curves defined by a particular contour line set (reference CLSREF points to the contour line
set). A terrain curve (TRNCUR) defines the portion of the contour line group that is within the cell.

 For further detailed information on the forming of a Terrain Definition and Model please refer to the AVEVA E3D
2.1 Terrain User Documentation.

Terrain data and contours may be


incorporated into drawings and intelligently
annotated to form project deliverables.
The representation of contours with inclusive
annotation is supported by a Line Style with a
text string interpretation of the intelligent text
#ELEVAT. Further, the View Visual Style has
been extended to support precision and units.

 For further detailed information on the use of Terrain data in Draw please refer to the AVEVA E3D 2.1 Draw User
Documentation.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 7 of 37


Product Release Letter
User-Defined Trunnions.

User-defined Trunnions may be defined via the Component Selection tab of the Supports Trunnion Data form
in the Paragon module (AVEVA Catalogue 2.1.0). The user is able to pick compatible components and apply
them as possible user selections for items in the make-up of a Trunnion.

Valid components are available in the Components for Trunnion lists and may be set as being active as
required. Items that appear as valid inactive selections are collected by support class from the range of
available components. A default active component exists for each component category and may be changed
via a right-click menu.

On creating a Trunnion type in the model, the user is presented with the support type information in addition
to tabs for each component. The user is able to select a component tab and dynamically change it to one of
the available component options as defined in Paragon.

In the example here the XAC18A tab has been selected and the
Reselect Ancillary Type button clicked to prompt the Ancillary
Selection form. The selections in the prompted form are limited to
the available types as specified in Paragon for this support type at
the given bore.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 8 of 37


Product Release Letter
In regards to administration, the component range for Trunnion Ancillary Components (AC) has been
expanded to include user definable supports (AC500-700 in the MDU project). There are two different classes
of items that can be created:

 User Defined Ancillary Components – AC500 - AC599.

 User Defined plate Components – AC600 - AC700.

The following update requirements are to be considered:

 The new trunnion functionality requires the latest ACP catalogue databases for the supports
application. These are provided in AVEVA Everything3D™ - Projects 2.1.0.4 and above.

 Users wishing to create user defined trunnion ancillary components (AC500 – 700) may need to
upgrade their existing MDU project to include these items.

 The upgrade process can be completed within the Paragon module via the ‘Check Supports
Application Defaults’ tool. It is important, however, that the user updating the MDU database has
appropriate write access to make any changes.

 For further detailed information on the setting and administration of user-defined trunnions please refer to the
AVEVA E3D 2.1 Supports User Documentation.

Carpenter & Patterson – Witch-Hanger Interface.

The Carpenter and Patterson Witch-Hanger interface software is now available for use within the Supports
application in AVEVA Everything3D 2.1.

Use of the software is administered in the Supports Admin Data form within the Paragon module.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 9 of 37


Product Release Letter
Available Hanger types for the interface are presented to the user in the Supports application.

On selection of the Hanger and required model data, the


Support Editor is updated to include a Witch-Hanger
interface button.

The Hanger design can be progressed and completed, with


the Hanger formed in the Supports model.

 For further detailed information please refer to the AVEVA E3D 2.1 Supports User Documentation.

In regards to the setup of the Witch-Hanger interface, specific file paths are set up within a new file called
hangerInterfaceConfiguration.xml in the default AVEVA E3D 2.1 install directory.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 10 of 37


Product Release Letter
Input/output directories are created automatically within the current project and will be stored in a directory
prefixed with the 3 letter project code i.e. <xxx>HID.

 In contrast with older versions of the software there is no longer a need to setup project specific evars within
evars.init for the hanger interface executable file or input/output folders in the project.

AVEVA Everything3D 2.1.0.4, Release No. 52502.


Mining Application.

AVEVA E3D 2.1 Fix.4 introduces the Mining application within the Model module. The Mining tab is prompted
via the selection of Mining from the Discipline options list and allows the creation and modification of mining
conveyors and equipment.

The application enables the user to define,


create and modify Conveyor elements
together with their associated covers and
supporting frames.

 AVEVA E3D – Projects 2.1.0 Fix.3 provides sample data for the new Mining application.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 11 of 37


Product Release Letter

The creation and modification of a Conveyor element is guided by an


intuitive user interface that steps the user through the required
design stages.
The example here illustrates how the user may configure the
Conveyor through the selection, spacing and definition (via diagram
field input) of the supporting Idler elements.
 The Idler Catalogue is based upon CEMA standards (Conveyor
Equipment Manufacturing Assoc.).

Mining equipment, grouped by process area, may be selected as


standard equipment items from the Standard (Equipment) form e.g.
a Banana Screen.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 12 of 37


Product Release Letter
The standard mining equipment is parametrised to allow the specification of equipment based on project
requirements e.g. Chutes of a given dimension.

As required of all Model data, Mining elements may be incorporated into drawings and intelligently
annotated to form project deliverables.

 For further detailed information please refer to the AVEVA E3D 2.1 Mining User Documentation.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 13 of 37


Product Release Letter
Vessel Framework Supports.

This release introduces Vessel Framework Supports to the Supports application in the Model module. The
Vessel Framework Supports are used for supporting pipework associated to Vessels. A default set of Vessel
Framework support templates are supplied with the Supports application (accessed via Supports tab >
Framework gallery).
A user may create Vessel Framework supports using a combination of framework types and ancillaries;
guided throughout the creation process by a series of prompts.

 Some vessel framework supports require the creation of support brackets on the vessel before creation.
In most cases, support brackets can be created as box primitives.

 For further information please refer to the AVEVA E3D 2.1 Supports User Documentation – Section
6.5 Vessel Framework.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 14 of 37


Product Release Letter
To support the introduced Vessel Framework Supports the following standards are available in the Supports
application:

 For further information please refer to the AVEVA Catalogue User Documentation- Section 10.13.19
Vessel Framework Supports for Pipes.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 15 of 37


Product Release Letter
AVEVA Everything3D 2.1.0.3, Release No. 52486.
Multiport Valves.

The IsoDraft module is now able to produce isometrics containing multiport valves and instruments. Such
valves are typically used in the dairy and food industries.

Users should note the generic type is INST to allow multi-connection


reference array.

Multiport Valves are either single, double or triple bodied in a tier of


varying orientation.

As an addition to ACP project MASTER/PIPECATA database a new CATA


/EXAMPLE-GEA-TUCHENHAGEN-CATA has been included with examples of
GEA Tuchenhagen multi-port dairy and food industry valves

To use these or other manufacturer valves/instruments of a similar design,


users should refer to the Isodraft reference manual.

There are 18 SKEY variations available – the below illustrates an example of a Three-Level Multiport Valve.

In regards to P-Points the following should be noted:


 Instrument dials can have a P3 with an unset bore for orienting the dial. This p-point will normally
be positioned perpendicular to the dial face, on the dial axis. A message will be output near the
component showing the orientation of P3.
 P-Point 11 is the Spindle attachment point and its PURP attribute should be set to ‘SPIN’.
 Multiport Valves may have up to 2 flushing/draining connections:
o These must be P-Point 9 and P-Point 10.
o The isometric will only show a symbolic line and a note CONT TO ”name” for each
connection.
o There will be no materials or isometric representation of the branch connection to these
points.

 For further information please refer to the IsoDraft Reference Manual: INST Symbol Keys and Symbol
Key Reference Index.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 16 of 37


Product Release Letter
AVEVA Everything3D 2.1.0.2, Release No. 52472.
AVEVA Bocad Steel Interface.

The AVEVA Bocad Steel Interface is an integral part of AVEVA E3D 2.1. The interface facilitates the transfer
of structural steel data between AVEVA E3D 2.1.0 and AVEVA Bocad Steel (2.1.1 onwards). The interface
makes allowance for the introduction of the new Structural Catalogues at AVEVA E3D 2.1.0 and the use of
GENSEC elements.

The AVEVA Bocad Steel Import and Export tools are located within the Import and Export groups in the
TOOLS tab.

New mapping files have been made available; one for each standard of the new AVEVA E3D 2.1 Structural
Catalogue, to be used with the most recent AVEVA Bocad Catalogue (2.2.1 and 2.3 onwards). These mapping
files are required to be customised where the AVEVA Bocad Catalogue has been altered or a differing
standard has been used in a project.

To aid the mapping process a new tool is available to


create or customise mapping files. The AVEVA
Structural Map File Converter is available from the
AVEVA Bocad Steel Import and Export forms via the
Control menu option Map Converter.

The standard P-lines that exist for the profiles within the new AVEVA E3D 2.1 Structural Catalogue are
sufficient to use the AVEVA Bocad Steel Interface - additional P-lines previously used are no longer required.
It should be noted that within the new Structural Catalogue ANGLE profiles have a new orientation
convention in line with other products in the market. This is managed by an internal orientation mapping
file.

 It is important to note that the AVEVA Bocad Steel Interface provided within AVEVA E3D 2.1 is compatible
with the ‘old’ Profile catalogue and P-lines as long as the specific P-lines have been installed.

In regards to the import process, it should be noted that only GENSECs will be created at import due to SCTN
elements being no longer used by the AVEVA E3D 2.1 Structural application.

 Please refer to the AVEVA E3D 2.1 User Documentation for further information regarding the
administration and use of the AVEVA Bocad Steel Interface in AVEVA E3D 2.1.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 17 of 37


Product Release Letter
AVEVA SDNF Interface.

The AVEVA SDNF interface facilitates the transfer of structural steel data between structural applications
using the SDNF neutral format file. The interface makes allowance for the introduction of the new Structural
Catalogues at AVEVA E3D 2.1 and the use of GENSEC elements for linear structural elements.

This SDNF interface is available in the Import and Export group of the TOOLS Ribbon tab.

A new mapping file format has been introduced (BLOCK). This will increase the speed of search within the
mapping file. As seen with AVEVA Bocad Steel Interface, a new tool is available to create or customise
mapping files with this new format – the AVEVA Structural Map File Converter. The tool is available from
the SDNF Import and Export forms via the Control menu option Map Converter.

 Existing customised mapping files will be required to be updated where the intent is to use the new
AVEVA E3D 2.1 Structural Catalogue. Sample mapping files are provided with the installation.

The standard P-lines existing for profiles in the new AVEVA E3D 2.1 Structural Catalogue are sufficient to use
the SDNF interface. It should be noted that within the new catalogue ANGLE profiles have a new orientation
convention in line with other products in the market. This is managed by the orientation mapping file.

In regards to the import process it should be noted that only GENSECs will be created at import due to SCTN
elements being no longer used by the AVEVA E3D 2.1 Structural application.

 Please refer to the AVEVA E3D 2.1 User Documentation for further information regarding the
administration and use of the AVEVA SDNF Interface in AVEVA E3D 2.1.

AVEVA Everything3D 2.1.0.1, Release No. 52435.


Supports: Creation of Branch Reinforcement Supports (Support Type BR).
This fix release incorporates Branch Reinforcement Supports into the
new AVEVA E3D 2.1 Supports application. The Branch Reinforcement
creation workflow has been aligned with the Supports application
interface and element hierarchy.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 18 of 37


Product Release Letter
List of Fault Corrections
This release includes the following fault corrections:
Incident Defect Product /
Description
number number Module
Title: E3D SLH - Tool Split Rails changes the obstruction List.
Symptoms: Subsequent to using the Split Rails tool the obstruction list is not set
81462 173518 SLH back to the initial value (Default is ALL).
Previous/Known workaround: None.
Solution: Fixed - the previous obstruction list is restored.

Title: Enhancement – Reporting: Using comment capture images in reports


Symptoms: Require ability to use Comment Capture images in reports.
202654 Reporting
Known workaround: -
Solution: A new control "Comment picture box" is added under Aveva controls.

Title: Pipe Creation Form - Available Bore list not refreshing.


Symptoms: On selecting a Specification from the Pipe form, the list of bore sizes
90363 193729 Piping does not refresh and retains the list of bores from the first Specification in the list.
Previous/Known workaround: Set the bore manually.
Solution: Fixed - each time a specification is selected the list of bores is refreshed.

Title: IsoADP - Cont'd labels disappear on Update.


Symptoms: Cont'd labels disappear on Update.
Previous/Known workaround: None.
67645 169767 Draw
Solution: Checks to determine which labels should be kept have been improved to
ensure labels are not removed (unless the component is removed) and their
positions are maintained.

Title: Supports – unable to add additional PIPE, TRAY or HVAC on a Special Support.
Symptoms: Unable to add additional PIPE, TRAY or HVAC on a Special Support.
90266 193512 Supports
Previous/Known workaround: None.
Solution: Fixed.

Title: Enhancement – Allow supports on Fixed Length Tube.


Symptoms: Supports on Fixed Length are not shown correctly.
210070 IsoDraft
Previous/Known workaround: None.
Solution: Allow supports on Fixed Length Tube.

Title: SLH Modify Form opened twice - SLH Element disappears.


Symptoms: On opening a SLH Modify form twice, the first modified Stair flight
disappears from the Display (although is created in the database).
81461 173512 SLH
Previous/Known workaround:
Solution: Fixed – the element is not removed from Display on opening a SLH Modify
form twice.
Title: Weld Table with True Type Fonts.
Symptoms: Where using TT Fonts (e.g. Arial) the positioning of text and the related
column frame line is not consistent.
97583 209347 IsoDraft
Previous/Known workaround: None.
Solution: Fixed - the characters are correctly spaced to take account of proportional
fonts.
Title: On adding a Structure element by ADD ONLY then next ADD ONLY fails.
Symptoms: Occurs where a framework is added thus preventing structural
elements below from being added.
210406 Structures
Previous/Known workaround: Remove framework from the Drawlist prior to
addition.
Solution: Fixed.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 19 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: HVAC Detailing Specs required in Project Defaults Directory.
Symptoms: Previously all HVAC Detailing specs are in PDMSDFLTS.
98944 212132 HVAC Previous/Known workaround: Use various PDMSDFLT paths.
Solution: Fixed - now possible to have a HVACADVSPEC sub-directory in the Project
Defaults directory (Example in %XXXDFLTS%/HVACADVSPECS).
Title: Problems creating supports on a pipe which is created in imperial units.
Symptoms: The validation of the newly created support fails due to a bore
mismatch.
99596 213481 Supports
Previous/Known workaround:
Solution: Fixed - the bores are compared correctly and the support is created
successfully given all other parameters are correct.

Title: Units switching from imperial to metric in Supports application.


Symptoms: When creating an ancillary with units set to imperial, the ancillary is
100781 216247 Supports created with metric units.
Previous/Known workaround: Necessary to switch units after creating an ancillary.
Solution: Fixed – original units are respected on creation.

Title: HVAC: Retain Material in Modification.


Symptoms: HVAC Material reset in modification.
97687 209519 HVAC
Previous/Known workaround: None.
Solution: Option added to main HVAC form to retain HVAC Material in modification.

Title: Supports MDS/APPDEFAULTS database updates 33 and 34 had errors.


Symptoms: Failures in updates 33 and 34.
99836 214127 Supports
Previous/Known workaround:
Solution: Fixed.

Title: Supports MDS/APPDEFAULTS Database Update 55 not working.


Symptoms: Update 55 displays in the available updates list but does not update.
99845 214195 Supports
Previous/Known workaround: N/A
Solution: Fixed.

Title: Mining commands error messages


Symptoms: Missing command error messages output when entering the Model
module.
97360 208885 Mining
Previous/Known workaround: Ignore the messages - they do not indicate that the
system will fail to operate correctly.
Solution: Fixed.
Title: Creating a Projection View from a limits-defined View loses Sections.
Symptoms: Creating a projection from a limits defined view (with limits type VSECs)
will cause the original view's VSECs to be deleted, when the 'normal' projection
91932 211443 Draw ribbon option is used.
Previous/Known workaround: None.
Solution: Fixed - Limits defined VSECs now kept as expected within both original
and projected views.

Title: A Draw Collection can not be used as a REME via the DRAWLIST Manager.
Symptoms: A Draw Collection can not be used as a REME via the DRAWLIST
97783 209608 Draw Manager.
Previous/Known workaround:
Solution: Fixed.

Title: SLH Admin Task - No Baseplate possible for Terminator Post.


Symptoms: Not possible to define a baseplate at a Terminator Post.
96918 207656 SLH
Previous/Known workaround:
Solution: Fixed.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 20 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: E3D 2.1 Model SLH Rung Ladder lower FFL.
Symptoms: Selecting FFL for creating a Ladder results in it being created from the
91388 197892 SLH bottom line of the selected element.
Previous/Known workaround:
Solution: Fixed.

Title: VSCAN aborts with database error 10 when the Drawing is outdated.
Symptoms: VSCAN fails.
92196 197969 Draw
Previous/Known workaround: None.
Solution: Fixed - VSCAN now skips elements that have been deleted.

Title: Enhancement - Confirmation message when clicking button "Task List".


Symptoms: Require confirmation message for Standards: create or modify forms.
58172 98916 SLH
Known workaround:
Solution: Fixed - Confirmation message prompted.

Title: Enhancement – Assemblies: Diagram required for Handrail Assemblies.


Symptoms: Diagram required for Handrail Assemblies.
58176 101153 SLH
Known workaround: -
Solution: Fixed - Diagrams introduced in the form.

Title: Enhancement – Auto-tagging GENSECs at midpoint.


Symptoms: Require ability to Auto-tag GENSECs at midpoint.
Previous/Known workaround: Manual movement of labels.
94310 201437 Draw Solution: New fields added to the Auto tagging form: an options list of plines and a
text box to define the proportional distance along pline. If the pline selected is not
valid for an element being tagged, the PKEY remains unset and a warning is added
to the error log.

Title: Ladder - Error message while creating Standards and Defaults Ladder module
Symptoms: ‘Error 24/06/2015 10:23:06 (2,891) An invalid zero direction has been
81293 175605 SLH obtained’ is presented.
Previous/Known workaround: -
Solution: Fixed.

Title: Draw - Scaling of text in graphic entities.


Symptoms: On scaling a (Table) it appears that the text is not scaled.
90428 193824 Draw
Previous/Known workaround:
Solution: Fixed - TEXPs are properly scaled.

Title: Collections and SCOSEL property.


Symptoms: SCOSEL property of GPSET does not report correctly when added as
95477 205494 Everything3D column to search list.
Previous/Known workaround:
Solution: Fixed.

Title: Russian chars are shown in DRAW as '?????'


Symptoms: Font 1 Russian chars are shown in DRAW as '?????'.
95446 204143 Draw
Previous/Known workaround:
Solution: Fixed.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 21 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Intermittent E3D Glitch in Piping/Branch using "SAME" command
Symptoms: On a branch when deleting the CE (eg FLAN, GASK) then using the SAM
or SAME command the software may crash or present an error (107 Invalid
reference). The problem occurs if the CE has the TEXIST attribute set to True. In this
91194 196096 Piping case the element that SAME will try to navigate to is the one that has just been
deleted.
Previous/Known workaround: Set TEXIST flag to false on the CE before deleting it.
Solution: Fixed - the code has been changed to go to the next element before
checking the TEXIST attribute.

Title: Saved view files can be overwritten if requested.


May Symptoms: User requires to overwrite files but error displayed.
199116 Everything3D
92940 Previous/Known workaround: Save to view files with a different name.
Solution: Form now allows existing view image files to be overwritten if requested.

Title: Component Editor form - Clearance uses obstruction volumes to calculate


distance.
Symptoms: Clearance uses obstruction volumes to calculate distance.
94386 201735 Piping Previous/Known workaround: -
Solution: Fixed - component editor now uses alternate syntax to the simple
clearance command. The function now orientates the component then positions
the relevant ppoints by a distance command; removing any obstruction calculation.

Title: Bent leaderlines apply glyphs to bend points.


Symptoms: Bent leaderlines apply glyphs to bend points.
82012 174830 Draw
Previous/Known workaround:
Solution: Fixed - Glyphs will now only appear at each end of the leader line.

Consolidated from previous fix releases:

AVEVA Everything3D 2.1.0.5, Release No. 52531.


Incident Defect Product /
Description
number number Module
Title: Enhancement - UCODE/PCODE selection via Options List rather than direct
input.
Symptoms: On administering a Visual Style Unit and Precision Code via the Visual
57527 97112 Draw Styles Administration form it is required that the options are made available by a
series of options lists rather than direct entry.
Previous/Known workaround: Direct entry to the Properties field.
Solution: UCODE/PCODE selection is now possible via Options List selection.

Title: It is not possible to save column settings for each search.


Symptoms: Column setup is not saved between Searches.
88006 188110 Everything3D
Previous/Known workaround: None.
Solution: Fixed - Column setup now saved.

Title: Several HULL parts were not displayed in E3D model module.
Symptoms: Incorrect generation of plates due to arbitrary notch NOT4.
90227 195825 Everything3D
Previous/Known workaround: None.
Solution: Fixed – notch is handled and Hull plate is displayed.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 22 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Properties Form: Parameters.
Symptoms: Modify Properties form is not prompted via the Parameters field of the
90774 195083 Everything3D Properties form.
Previous/Known workaround:
Solution: Fixed – Design Parameters may now be modified.

Title: Marine model cannot be presented properly.


Symptoms: Issue where a tapered endcut has been applied to a stiffener.
93621 200200 Everything3D
Previous/Known workaround: None.
Solution: Fixed – endcut considered correctly.

Title: Dimension attribute values are not scaled once exported to AutoCAD.
Symptoms: Dimension attribute values are not scaled once exported to AutoCAD.
93974 200785 Draw Previous/Known workaround: None.
Solution: Fixed - Dimension and overshoot are scaled once SHEE is exported to
dxf/dwg.

Title: Imperial - Split does not work properly.


Symptoms: Split does not work properly with imperial units. When attempting to
split beams, the command does not complete and the message window reports
94679 202335 Structures
"Splitting method failed".
Previous/Known workaround: None.
Solution: Fixed – able to Split with imperial units.

Title: Router - Different Reporting of Results in E3D2.1


Symptoms: In certain circumstance when using Router in E3D 2.1 the reporting of
95032 203071 Piping the results differ to that experienced in 12.1.SP4.
Previous/Known workaround: Route pipes individually.
Solution: Fixed.

Title: Wrong position of GENPRI between fixes.


Symptoms: Disparity in GENPRI position between fixes.
95099 203213 Everything3D
Previous/Known workaround: None
Solution: Fixed.

Title: PLCL@ and OSHT@ not working correctly in Draw.


Symptoms: Using the PLCL@ command on a DPOI or DPPT, the PLCL cannot be set
to a negative value.
204899 Draw
Previous/Known workaround: None.
Solution: PLCL@ and OSHT@ commands can now be used correctly for both
dimensions and individual dimension points.

Title: ABSI - GENSEC with Spec Ref including special UTF8 Character are not mapped
(import or export).
Symptoms: GENSECs with a Spec Ref including special UTF8 Characters are not
196700 Everything3D mapped (import or export). The issue principally concerns the provided Russian
Standard where the mapping file requires further amendment.
Previous/Known workaround: None.
Solution: Fixed.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 23 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: ABSI - Mis-match in the Chinese mapping file.
Symptoms: The Chinese mapping file requires further amendment to correct
profiles with CatRef CH_WT_S3_WG and to address the incorrectly mapped
196909 Everything3D diameter for Bocad profiles in the following series: CH_ST_S1_WG, CH_ST_S2_WG,
CH_ST_S3_WG, CH_WT_S1_WG and CH_WT_S3_WG.
Previous/Known workaround: None.
Solution: Fixed

Title: Enhancement - Model Reference Check for Hidden Elements.


Symptoms: Requirement to easily view and check hidden annotation.
Previous/Known workaround: n.a.
124077 Draw
Solution: Model reference check can now be applied to hidden elements by using
the new function Hidden Annotation found in the ANNOTATE tab in the ribbon. This
function is applicable to dimensions, grid rulers, and labels.

Title: Enhancement - Additional grips of dimension vertices should be controlled by


the additional grips toggle on the status bar.
Symptoms: -
133347 Draw Previous/Known workaround: Use Vertex Editor Properties Grid to display grips.
Solution: If the additional grips toggle is on in the Draw Status Bar, selecting a
dimension vertex in the vertex editor form will display grips for overshoot and
projection line clearance.

Title: Unable to modify dimension 'H' of Gravity Inclined Take-up.


Symptoms: In regards to the gravity inclined take-up, a user is unable to edit the
dimension 'H' (Vertical Length from Working Position to Take-up) either through the
206846 Mining
Creation or Modification forms.
Previous/Known workaround: None.
Solution: Fixed.

Title: Modify Properties form for standard equipment does not update to CE
selection.
Symptoms: The Modify Properties form prompted from the Standard Equipment
207135 Mining form does not update to match the selected current element.
Previous/Known workaround: The Modify Properties form is correctly updated for
the current element on being prompted via the main application Properties form.
Solution: Fixed.

AVEVA Everything3D 2.1.0.4, Release No. 52502.


Incident Defect Product /
Description
number number Module
Title: Chamfer value for Tread Template Builder not working.
Stairs, Symptoms: Entering a value into the Chamfer field has no bearing on the tread end
49388 78274 Ladders & plates.
Handrails Previous/Known workaround: None.
Solution: Fixed - Chamfer is now implemented for the tread template.

Title: Stair Flight aids for extending stringers not shown.


Stairs,
Symptoms: Omission of aids for Stringer extension.
54519 90793 Ladders &
Previous/Known workaround: None.
Handrails
Solution: Fixed - Aids are now shown for extend bottom through floor.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 24 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module

Title: Handrails – Incorrect positioning of post on stairs with cranked stringers.


Stairs,
Symptoms: -
59707 104428 Ladders &
Previous/Known workaround: None.
Handrails
Solution: Fixed – posts are positioned correctly.

Title: Kilonewton missing from the list of units.


Symptoms: While Newton is available as a unit, Kilonewtons are not.
70625 141944 Everything3D
Previous/Known workaround: Utilise Newtons.
Solution: Fixed – Kilonewtons are now available.

Title: Errors when modifying Handrail or Ladder assemblies.


Stairs,
Symptoms: Error presented on modifying a Ladder or Handrail assembly.
71276 143917 Ladders &
Previous/Known workaround: None.
Handrails
Solution: Fixed.

Title: Corner spacing dependence from BRadi.


Stairs, Symptoms: Where the BRadi property is set to 0, the corner spacing value is
85268 193290 Ladders & ignored.
Handrails Previous/Known workaround: None.
Solution: Fixed.

Title: Hull Graphics - Vitesse Holes in Shell Profiles


Symptoms: Vitesse Holes in Shell Profiles are not shown correctly.
85491 182396 Everything3D Previous/Known workaround: None.
Solution: Fixed - Corrected so geometry is cached in AVEVA Marine 12.1.5 and then
used in AVEVA E3D 2.1.

Title: Not possible to add labels to PIPE elements via the Autotagging process.
Symptoms: -
90492 193989 Draw Previous/Known workaround: Manual labelling or by Autotagging alternative
(owned) element with PIPE annotation via appropriate intelligent text.
Solution: Fixed - PIPEs may now be labelled via the Autotagging process.

Title: Cursor disappears when opening dialog boxes.


Symptoms: When opening some types of dialog box with the cursor over the 3D
canvas, the cursor disappears until the dialog box is closed.
90554 194114 Everything3D Previous/Known workaround: Ensure the cursor is not over the 3D canvas prior to
opening a dialog box.
Solution: Fixed - the common framework is now aware of the cursor state and will
be displayed when a dialog box is opened.

Title: Draw crashes on copy/paste in Browser explorer.


Symptoms: Draw exits on copy/paste in Browser explorer.
92053 197744 Draw Previous/Known workaround: Utilise an alternative copy/paste workflow.
Solution: Fixed – the copy/paste functionality can be used within the Browser
explorer.

Title: Pipe Splitting assemblies get the wrong LSTU.


Symptoms: After splitting a pipe using flanged assemblies the tube can be from a
90742 194618 Piping different specification.
Previous/Known workaround: Select tube after splitting action.
Solution: Fixed.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 25 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module

Title: Whole equipment added when adding within clip box volume.
Symptoms: Part of equipment added - leading to graphical selection issues.
91298 196275 Equipment Previous/Known workaround: Add whole equipment using Model Explorer.
Solution: Fixed – where part of an Equipment is within the clip volume it is replaced
by the owning Equipment.

Title: On prompting the Login form, the MDB is restored to the previous selection.
Symptoms: When a user is logging in and MDB selection is not the last action, the
90440 193842 Everything3D MDB may be restored automatically to the chosen MDB in the previous session.
Previous/Known workaround: -
Solution: Fixed.

Title: Autotagging: Removing redundant label may destroy local tagging definition.
Symptoms: On removing redundant Tags the referenced GLAB is deleted – the local
90493 193992 Draw rule defined is thereafter lost.
Previous/Known workaround: None.
Solution: Fixed.

Title: User Autoname options.


Symptoms: A User is unable to locally switch on/off Autonaming rules.
Previous/Known workaround: Copy complete system naming rules file to user
87508 186609 Everything3D
directory.
Solution: Fixed – User local Autoname options have been combined with system
Autoname rules.

Title: NSBC Detail Plots not produced.


Symptoms: Error received – ‘(64,332) LDIMENSION 1 of ... : Dimension direction
90855 194877 Piping parallel to View direction.’
Previous/Known workaround: None.
Solution: Fixed.

Title: ‘Not all bypass loops are closed’ error for coincident Trunnions.
Symptoms: Cluttered Text.
92647 198616 Supports
Previous/Known workaround: Separate trunnions by 2mm.
Solution: Fixed.

Title: Unable to Penetrate using an UDET.


Symptoms: Equipment Penetration does not work when using an UDET.
93196 199497 Everything3D
Previous/Known workaround: None.
Solution: Fixed - Equipment penetration fixed to recognise an UDET of EQUI.

Title: DOUBLEBACK PIPE error for Trunnions.


Symptoms: Isometric fails with DOUBLEBACK PIPE error.
90200 193300 Supports
Previous/Known workaround: None.
Solution: Fixed.

Title: Failure in connecting Head or Tail to another Head or Tail.


Symptoms: Failure experienced due to operation requiring continuous p-point list
94721 202459 Piping without gap.
Previous/Known workaround: None.
Solution: Fixed.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 26 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module

Title: Management of NAPPFLAG for Fitting during SCTN to GENSEC conversion.


Symptoms: Negative NBOX used to represent a hole in SCTN did not cut owning
181831 Structures GENSEC.
Previous/Known workaround: Set NAPPFLAG -1 to NAPPFLAG 2.
Solution: Fixed - NAPPFLAG set during conversion.

Title: Improved Performance of the Piping Component Editor Form


Symptoms: Lag on switching between component types within the component
93617 201317 Piping editor form.
Previous/Known workaround: None
Solution: Fixed – improved performance of the form.

Title: TUBI and ROD elements not required on reorder hierarchy form.
Symptoms: Unnecessary elements within form.
93704 200287 Piping
Previous/Known workaround: None.
Solution: Fixed - TUBI and Rod not shown on reorder hierarchy form.

Title: Model Editor Selection Issue.


Symptoms: Unable to multi-select in model edit mode using ctrl + left mouse
94525 202476 Everything3D button.
Previous/Known workaround: Able to use ctrl + right mouse button.
Solution: Fixed.

Title: ABSI: Question mark symbols are appearing in Bocad if we provide Unicode
characters in Project header and User Data.
Symptoms: Substitute symbols (question mark) are visible in AVEVA Bocad where
Unicode characters are used in the project header or user data.
196401 ABSI
Previous/Known workaround: In order to exchange Unicode characters in AVEVA
Bocad Steel files, a user may edit the BocadUni.map file to replace ENCODING:ASCII
to ENCODING:UTF8BOM.
Solution: Fixed.

Title: TEXP - LHEI and CHEI query incorrect for ByStyle.


Symptoms: LHEI and CHEI query incorrect for ByStyle.
190060 Draw Previous/Known workaround: CHEITX is the Draw property to be used - for
consistency there was a need for an enhancement for a new equivalent 'LHEITX'.
Solution: New attribute LHEITX can be used to query LHEI.

AVEVA Everything3D 2.1.0.3, Release No. 52486.


Incident Defect Product /
Description
number number Module
Title: View limits button should be activated when a view is selected in canvas or
using the Explorer.
Symptoms: The View limits button only activated on making a view the Current
86790 185142 Draw Element. In canvas selection did not cause the button to activate.
Previous/Known workaround: Utilise Current Element.
Solution: The current selection is now used to activate button and populate the
form.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 27 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Error on exporting Sheet with an incorrect dimension to DWG.
Symptoms: If a Sheet has at least one dimension with an invalid direction, e.g.
direction that is equal to direction of view, an error is presented “Severe serialization
87267 186131 Draw error occurred, operation aborted” on exporting to DWG.
Previous / Known workaround: Correction to dimension direction.
Solution: Fixed – LDIMs with incorrect direction are considered and handled in the
export.

Title: Label Grip invisible when leader line is set to off.


Symptoms: Grip becomes invisible where leader line is off (attribute Lleader eq false)
88357 190039 Draw on General and Symbolic labels.
Previous / Known workaround: None.
Solution: Fixed – grips are no longer invisible for identified scenario.

Title: Enhancement - Customisation support for Revision Control Snapshot


Capability.
Solution: The PmlRevisionControl object provides access to creating snapshots for
revisions and graphically displaying or comparing revisions. Like with the DRAW
Graphical User Interface, the snapshots are created and stored as an ARCHIV element
beneath the REVI.

Note that the PmlRevisionControl object only operates on the Sheet that is currently
active and displayed in the canvas.

import 'Aveva.Pdms.SDInteraction.UI'
using namespace 'Aveva.Pdms.SDInteraction.UI.Gui.RevisionControl'
- 190229 Draw !revisions = object PmlRevisionControl()

Methods:
COMPAREREVISIONS(STRING, STRING)'
COMPAREREVISIONS(ANY, ANY)'
CREATESNAPSHOT(STRING)'
CREATESNAPSHOT(ANY)'
DISPLAYREVISION(STRING)'
DISPLAYREVISION(ANY)'
HASSNAPSHOT(STRING)'
HASSNAPSHOT(ANY)'

Please see the Draw Reference Manual for more information.


Title: Fatal Error opening sheet when 'units numeric dist' used.
Symptoms: Fatal Error opening sheet when 'units numeric dist' used.
88820 190466 Draw
Previous / Known workaround: None.
Solution: Fixed – error is no longer presented for given scenario.

Title: Changing Rotation angle to 90 degrees causes problems with limits volume box
& Section plane Grips.
Symptoms: The 3D View in Draw does not currently respect an applied View rotation
angle.
83826 178445 Draw
Previous / Known workaround: The Edit in 3D View button is disabled where a View
Rotation angle is not equal to zero.
Solution: Fixed – 3D View can now be used for Views where the View Rotation angle
is not equal to zero.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 28 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Enhancement - PML access to element selection using the Draw browser.
Symptoms: It was not possible to use the Draw browser from PML to return a
selected element.
81449 179250 Draw Solution: There is a new PML object PmlItemOpen which has several methods that
can be used to show the Draw browser for different element types. The methods can
take an argument providing an initial location for the browser, such as a library. The
name of the selected element will be returned to the PML as a String.

Title: Equipment- Selecting view direction with PowerCompass exits primitive


creation command.
Symptoms: While creating the primitive, selecting a view direction using the
87269 186147 Everything3D
PowerCompass will exit the command.
Previous / Known workaround: Set view direction by alternative methods.
Solution: Fixed – PowerCompass may be used to set view direction.

Title: Enhancement - Provide PML access to the entities selected in the 2D canvas
Symptoms: Currently there is no PML access to the 2D canvas selection as the
existing Selection object only operates on the 3D view.
Known workaround: Use of the ID syntax.
Solution: The new CanvasSelection object has been provided that is more generic
than the Selection object and allows the user to interact with the graphical selections
set for the current document in both 2D and 3D. For example it provides PML access
to the selection in both the 2D Draw canvas and the 3D canvas in Model and Draw.
Note that it only operates in graphical mode, not in TTY mode.

Unlike the Selection object, the CanvasSelection object allows PML access to the 2D
canvas. This does not replace the Selection object for 3D which continues to provide
more specialist and powerful access to the selection set in the 3D canvas.

70001 140179 Draw import 'aveva.interaction.generic'


using namespace 'Aveva.Interaction.Generic.Tools.Selection'
!canvas = object canvasselection()

Methods:
.canvasselection()
Creates an empty CanvasSelection object
.getselection()
Returns all the elements currently selected in the canvas as an ARRAY of DBREFs
.add(DBREF)
Selects the passed element if it corresponds to an entity
.remove(DBREF)
Deselects the passed element if it corresponds to an entity selected in the canvas
.clear()
Deselects all entities selected in the canvas

Title: Graphics Performance while manipulating Laser Data and creating Assemblies
with Laser Data in View.
Symptoms: Reduced graphical performance on manipulating laser data.
90314 193680 Everything3D
Previous / Known workaround: Remove laser data from 3D view.
Solution: Fixed - improved performance of graphical rendering with laser data in the
View.

Title: 3D view appears stretched across multiple monitors.


Symptoms: Distorted 3D view when stretched across multiple screens.
89529 191699 Everything3D Previous/Known workaround: None.
Solution: Fixed - Multiple monitors taken into account when setting maximum 3D
view size.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 29 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Forms slower to show when laser data used.
Symptoms: Forms slower to show when laser data used.
90527 194068 Everything3D
Previous/Known workaround: Loading faster on second prompting of form.
Solution: Fixed – laser data no longer rendered for form ‘mini views’.

Title: GENPRI positions displayed in an incorrect location.


Symptoms: The position of imported Equipment (in AVEVA PDMS 12.1.4) is visually
92717 198673 Everything3D incorrect in position when viewed in AVEVA E3D2.1.
Previous / Known workaround: None.
Solution: Fixed – transformations are applied correctly.

Title: Enhancement - Unfill HVAC function.


Previous / Known workaround: Manual operation.
- 158241 HVAC
Solution: Provision of a new Unfill button within the HVAC user interface (and the
original Apply button has been renamed Fill).

Title: Stairs with Pitch Validation Value default - problem with configurations.
Symptoms: When a Stair Flight is modelled using a default where the pitch validation
Stairs, value is used to calculate the optimum stair rather than the pitch angle,
86848 185242 Ladders & configurations which meet the required default validation value are highlighted
Handrails amber (with a warning that they DO NOT meet the optimum pitch validation value).
Previous / Known workaround: None.
Solution: Fixed.

Title: Stairs using validation value show acceptable configurations as unavailable.


Stairs,
Symptoms: Acceptable configurations shown as unavailable.
87606 186888 Ladders &
Previous / Known workaround: None.
Handrails
Solution: Fixed – all required configurations are now available.

Title: Walls & Floors - Setting elevation by selecting ref grid.


Symptoms: Clicking the elevation labels in Reference Grids does not set the
81154 172871 Structures elevation.
Previous / Known workaround: The user must click the grid plane lines of the grid.
Solution: Fixed – now able to select grid labels to set the elevation.

Title: Walls & Floors - Connections > Tidy > Joints form deletes JLDATUs
Symptoms: Connections > Tidy > Joints form deletes JLDATUs.
91773 197206 Structures
Previous / Known workaround: -
Solution: Fixed – tidy function applies to only Joint of Walls e.g. STWALL

Title: E3D Insight crashes/loops.


Symptoms: When trying to display a panel containing profiles with endcut type 104,
91093 195439
E3D Insight the system stops responding.
91095 195447
Previous/Known workaround: None.
Solution: Fixed.

Title: Piping component editor - Branch Name does not fit


Symptoms: Long branch names can overlap onto two lines if the name length is
around 30 characters but the overlap is overwritten by the spec gadget.
Previous/Known workaround: None.
90259 193493 Piping
Solution: The branch name field width has been increased to handle approximately
36 characters on a single line. It will accommodate the maximum of 50 characters on
two lines with no overlap. The spec name field width has been increased by a similar
amount.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 30 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Piping - Presentation of the Surface Treatment Report
Symptoms: Currently the user has to manually drag each column to make the entries
87042 185650 Piping visible.
Previous / Known workaround: Manually drag each column to desired position.
Solution: Fixed – default width increased.

Title: Enhancement - Filter on the Field List


83450 178315 Reports Previous / Known workaround: None.
Solution: Now able to apply a filter on the Field List and Parameter.

Title: Define Route - Pick the entry and exit points.


Symptoms: When creating a cable and using the define route option, application
currently attempts to select the two closest cableways for entry and exit points. This
does not work as expected because this does not consider the interference class of
86057 183586 Cable
the cableways with respect to the cable.
Previous / Known workaround: -
Solution: Fixed – user is able to pick the entry and exit points to populate the cable
branch entry form

AVEVA Everything3D 2.1.0.2, Release No. 52472.


Incident Defect Product /
Description
number number Module
Title: Cannot enter AVEVA E3D 2.1.
Symptoms: Error presented on failure to find the product executables within the
C:\Program\ file path.
88503 189490 Everything3D
Previous / Known workaround: Install AVEVA E3D 2.1 to a location without a space
in the file path.
Solution: Fixed.

Title: Insufficient brackets for expressions.


Symptoms: The textural form of expressions containing a mix of /, * do not always
have sufficient brackets to maintain the meaning of the expression.
190964 Everything3D
Previous / Known workaround: It is only the textural output which is affected,
internally the expression will evaluate correctly.
Solution: Fixed.

Title: System & Session Data.


Symptoms: For a ‘general’ E3D user, the Databases in an MDB are re-ordered so that
RW Databases are placed first in the list of current Databases in the MDB.
88515 189666 Everything3D Previous / Known workaround: Manipulate the MDB order to suit the current user
session requirements.
Solution: Databases defined dynamically in a dbset will be in reference number
order. Databases in the MDB retain the order they were assigned in Admin.

Title: Migration - Text and Symbol mirror on applying a negative Scale.


Symptoms: When applying a -1 to the XSCALE, the Symbol and inclusive Text
elements mirrors.
190054 Draw
Previous / Known workaround: None for described workflow.
Solution: On applying a negative scale the symbol will mirror but the text will remain
correctly orientated.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 31 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module

Title: Vertex Editor – Database Element Name cannot be modified.


Symptoms: Changing the DDNM for a DPPT in the Vertices Editor is not saved.
190189 Draw
Previous / Known workaround: Use canvas selection workflow.
Solution: Fixed.

Title: New labels inherit LAYE justification and alignment overriding template.
Symptoms: When creating new labels from PML (or auto-tagging), the default tends
to be incorrectly JUST LEFT and ALIGN BBODY.
Previous / Known workaround: Manual modification.
189224 Draw
Solution: Default values for Alignment and Justification attributes on LAYE and SLAB
elements are set to ‘By Template’. Note: that when creating new LAYE elements from
the Autotagging form values are overwritten by the default file PDMSUI\dflts\dra-
gen-taglay. This file is customisable by the user.

Title: New pseudo attribute required to determine if a GENSEC is a tapered profile.


Symptoms: Missing attribute.
89705 192120 Catalogue
Previous / Known workaround: None.
Solution: LTAPER attribute added.

Title: Length of GENSEC doesn't include the cut when a negative is inside.
Symptoms: The length of GENSEC doesn't include the cut when a negative is inside.
184280 Structures
Previous / Known workaround: None.
Solution: TCTL now accounts for negative primitives for straight GENSECS.

Title: Split command will not split GENSECs where not created in plane of member.
Symptoms: When attempting to split a GENSEC with another GENSEC when the
GENSECs have not been created in the plane in which they lay, the split does not
88572 189582 Structures work.
Previous / Known workaround: None.
Solution: Fixed.

Title: Error in Bracing Gap functionality.


Symptoms: When attempting to modify bracing gaps in the instance there are no gap
88361 189165 Structures reference elements an error is displayed.
Previous / Known workaround: None.
Solution: Fixed.

Title: Require current radius to be displayed when changing a curved GENSEC radius.
Symptoms: Current radius feedback is not shown.
86764 185072 Structures
Previous / Known workaround: Reference to Properties Grid.
Solution: Fixed – feedback provided.

Title: Curved GENSECS – no feedback when inputting an invalid radius


Symptoms: When using the grips to enter a radius for a curved GENSEC, if an
excessive radius to fit the GENSEC is entered, no warning is presented to the user
86765 185073 Structures
informing the user the entered value is invalid.
Previous / Known workaround: -
Solution: Fixed – invalid values can no longer be input.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 32 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module

Title: Require a Repeat option for the Mitre command.


Symptoms: Enhancement request.
162030 Structures Previous / Known workaround: -
Solution: Repeat mode now available via the Context Editor menu for the Mitre
command.

Title: Mitre operation - option to connect mitred ends.


Symptoms: Enhancement request.
174697 Structures Previous / Known workaround: -
Solution: Connection option added to Mitre command and may be selected by the
user (not default mode).

Title: Detail mode initial rise stairs have incorrect length extension / landing panels.
Symptoms: When an initial rise configuration stair flight is created which has an
Stairs,
extension and/or a landing, the panels on the extension and landing are not allowing
87415 186456 Ladders &
for a tread overlap.
Handrails
Previous / Known workaround: -
Solution: Fixed.

Title: Stair Flight - Rise position altered while modifying Detail Mode Stair flight with
Initial Rise configuration.
Stairs,
Symptoms: It has been observed that Rise Above\Below tread alters while modifying
186751 Ladders &
Stair flight.
Handrails
Previous / Known workaround: None.
Solution: Fixed – check has been added.

Title: Stair Flight using default with pitch validation presents warning.
Symptoms: When modelling a stair flight which is using a Default where the pitch
Stairs, validation rather than angle is used to calculate the stair, a warning message is
87605 186886 Ladders & displayed when picking the required configurations.
Handrails Previous / Known workaround: Issue reproducible for the pitch Validation Value in
the range of 600 to 660.
Solution: Fixed.

Title: Initial Rise Stair Flights - pitch value incorrectly rounded


Stairs,
Symptoms: None.
81224 173027 Ladders &
Previous / Known workaround: None.
Handrails
Solution: Fixed.

AVEVA Everything3D 2.1.0.1, Release No. 52435.


Incident Defect Product /
Description
number number Module
Title: Search Performance when applying a PML expression.
Symptoms: A search under the World element with element Type set to [ALL] and
the free filter expression set to not(unset(description) has a negative performance
- 176965 Everything3D impact.
Previous / Known workaround: Recommended that such searches are avoided.
Solution: Fixed - improved performance of message window when receiving errors
from search.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 33 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module

Title: Open item browser dialog is slow to appear with large projects.
Symptoms: Open item browser dialog is slow to appear.
Previous / Known workaround: None.
Solution: The open and admin hierarchy browse dialogs, as well as all 'create
element' dialogs, now start up faster as the database is read as and when the
- 178093 Draw hierarchy is expanded. To support this development element name searches in the
browser are based upon a database name search. Note that the search finds any
elements of the appropriate type with a name containing the search fragment
anywhere in the name, as before. However, searching for elements with a name
beginning with a search fragment is faster and can be performed by prefixing the
search text with a forward slash '/' to indicate this is the start of the name.

Title: Element Selection browser dialogs should hide empty libraries.


Symptoms: Certain browser dialogs targeted at element selection display empty
directories and allow element creation which is inappropriate to the workflow.
Previous / Known workaround: None.
- 185795 Draw Solution: Browser dialogs targeted at element selection (as opposed to 'create' or
'picture file open'), now disallow the 'New' option either via the top left hand button
or via right click. In addition, these dialogs will only show hierarchy containing existing
elements of the required search types (this improves performance and allows
elements to be found more easily).

Title: Error presented when using check support in Clasher where the Supports
application is not loaded
- 185520 Supports Symptoms: Error: Aborted !!findSupports.addPickedElement(!this.re turn[1], FALSE)
Previous / Known workaround: Open Support application prior to clashing.
Solution: Fixed.

Title: Exception when setting an ENDATU POSL attribute using the Properties Grid.
Symptoms: Exception experienced on the system attempting to find the plines for
187619 Everything3D the ENDATU.
Previous / Known workaround: Set attribute via the command window.
Solution: Fixed – system checks ENDATU owner for a list of allowed Plines.

Title: Incorrect Isometric for a Pipe containing a PIPCA connection at a TEE where
Hyper Plant is on and weld numbers from Database.
- 186032 IsoDraft Symptoms: Incorrect Isometric for described scenario.
Known workaround: None.
Solution: Fixed.
Title: The default bend selection form does not reload available bending machines.
Symptoms: Available bending machines are not reloaded on opening the default
bend radius form and an error occurs when a wall thickness cannot be obtained.
Previous / Known workaround: Restart E3D to reload the bending machines but no
- 187009 Piping workaround for described wall thickness error.
Solution: Fixed - the form now reloads the available bending machines each time the
form is opened. The form also handles the case where a wall thickness cannot be
obtained.

Title: Updated Samples.zip omitted from E3D 2.1 install.


Symptoms: As described.
- 187013 Everything3D
Previous / Known workaround: None.
Solution: Fixed – updated Sample.zip delivered with fix release.
Title: Creating a SYTM under a VSI Template causes an Error Message.
Symptoms: The error only occurs if the VSI Library is created using the right-click
83881 178524 Draw menu option rather than clicking the 'create' button.
Previous / Known workaround: Utilise the ‘create’ button to create the VSI Library.
Solution: Fixed – no error received.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 34 of 37


Product Release Letter
Incident Defect Product /
Description
number number Module
Title: Intelligent Text - unable to open a bracket directly after a closing bracket.
Symptoms: Unable to open a bracket directly after a closing bracket
61674 112168 Draw Previous / Known workaround: Insert and then remove a <space> between bracket
characters.
Solution: Fixed.

Title: Compound joints (SCTN > SNOD > SCOJ > SUBJ) are omitted during SCTN to
GENSEC conversion
- 181832 Structures Symptoms: As described above.
Previous / Known workaround: -
Solution: Fixed.

Title: Location of a View on a RSO cannot be changed.


Symptoms: After creating a view in an RSO plane, if the view is copied, the location
86862 185278 Draw in the Properties Grid cannot be changed to another RSO location.
Previous / Known workaround: None.
Solution: Fixed - it is now possible to change Location definition.

Title: Revision Form - unable to expand Text Column.


Symptoms: Unable to expand the Rev By Text field.
- 190049 Draw
Previous / Known workaround: None.
Solution: Fixed - all columns can now be resized as required.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 35 of 37


Product Release Letter
PRODUCT QUALITY STATEMENT
The development, maintenance and testing of AVEVA Solutions’ software products is carried out in
accordance with the AVEVA Quality Management System lifecycle processes and this document includes a
summary of the testing carried out on this release and a list of significant defects known to exist at the time
of release.

Development Testing
Developers have carried out unit testing of each enhancement and/or fix in the development environment
to verify that any new functionalities have been correctly implemented and identified defects have been
corrected.
Regression tests have been run in the development environment to verify that enhancements and/or fixes
have not adversely affected the integrity of the product.

System Testing
Independent system testing has been carried out on this product, as released, to verify that it installs
correctly in all supported configurations that any new functionalities have been correctly implemented and
identified defects have been corrected.

Acceptance Testing
AVEVA’s Training and Product Support group is satisfied that the System Testing for this release is sufficient
to assure product quality.
Any exceptions found during Acceptance Testing or after release will be reported in the Product Release
Latest Update Note on AVEVA's support web site http://downloads.aveva.com/52541/w52541.pdf.

Exceptions – Significant Defects and Recommended Workarounds


AVEVA intends to fix the defects listed below in a fix release or service pack as soon as reasonably possible.
 Pipe Fabrication utilities are not included in the first release of AVEVA E3D 2.1.0. Functions linked to Pipe
Fabrication are displayed in the user interface but are greyed out.

 Laser. The Box and Cylinder primitives (only) are fully compatible with the Highlight and Mask laser data
features. The Box primitive (only) is fully compatible with the forming of a Demolition package volume.

 Supports (TFS-183921). It is not currently possible to set the Support joint justification to a Pline of the
Column.

 3D View Selection (TFS-174778). Pipes with no component cannot be selected via a window selection in
the 3D View.

 Install (TFS-186636). AVEVA E3D 2.1 currently does not support a Project installed on a Windows 8.1 D:\
partition where the file path contains spaces. The issue is linked to the install of AVEVA E3D 2.1 to a
volume with 8dot3naming disabled referencing projects installed to a volume with 8dot3naming enabled.
An installation error is presented on first running AVEVA E3D 2.1 and on subsequent occasions the login
form is presented but without Project tiles for selection.

 Terrain (TFS-200037). A Line Style with a Text String (TXTSRI) defined does not export correctly to DXF,
DGN or PLOT formats. This prevents the export of contour annotation to these formats.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 36 of 37


Product Release Letter
Interoperability with AVEVA PDMS / Hull & Outfitting 12.1.SP4.
 Hull Projects. Spaces in Project pathnames should be avoided for AVEVA Marine (Hull) 12.1.SP4 data
being used within AVEVA E3D 2.1.

 AVEVA Global. All extract database FLUSH and ISSUE commands must be undertaken from within AVEVA
E3D 2.1 when accessing a globalised project with both AVEVA PDMS / Hull & Outfitting 12.1.SP4 and
AVEVA E3D 2.1.

For the latest list of exceptions and other updates, please see the Product Release Latest Update Note on
AVEVA's support web site http://downloads.aveva.com/52541/w52541.pdf.

Please refer also to the Product Release Latest Update Note for the original full release,
http://downloads.aveva.com/52421/w52421.pdf.

d52541 6-Oct-16  Copyright 2016 AVEVA Solutions Limited Page 37 of 37

You might also like