Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 12

TYPE OF SCG Failure Reason

1) t310-Expiry

2) synchReconfigFailure-SCG

3) randomAccessProblem

4) rlc-MaxNumRetx

5) srb3-IntegrityFailure

6) scg-reconfigFailure

SCG/MCG failure handling


Abhijeet Kumar5G No Comment

05
JUL
SHARE

SCG/MCG failure handling
Abhijeet Kumar5G No Comment

05
JUL
SHARE





 RLF is declared separately for the MCG and for the SCG
 If radio link failure is detected for MCG, the UE initiates the RRC connection re-
establishment procedure
The following SCG failure cases are supported:
– SCG RLF;

– SN change failure;

– For EN-DC, NGEN-DC and NR-DC, SCG configuration failure (only for messages on SRB3);
– For EN-DC, NGEN-DC and NR-DC, SCG RRC integrity check failure (on SRB3).

 Upon SCG failure the UE suspends SCG transmissions for all radio bearers and reports
the SCG Failure Information to the MN, instead of triggering re-establishment.
 In all SCG failure cases, the UE maintains the current measurement configurations from
both the MN and the SN and the UE continues measurements based on the configuration
from the MN and the SN if possible. The SN measurements configured to be routed via the
MN will continue to be reported after the SCG failure
 The UE includes in the SCG Failure Information message the measurement results
available according to the current measurement configuration of both the MN and the SN.
The MN handles the SCG Failure Information message and may decide to keep, change, or
release the SN/SCG. In all the cases, the measurement results according to the SN
configuration and the SCG failure type may be forwarded to the old SN and/or to the new
SN.

SCG failure information

SCGfailureInformation
 The purpose of this procedure is to inform E-UTRAN or NR MN about an SCG failure
the UE has experienced i.e.
 SCG radio link failure, failure of SCG reconfiguration with sync, SCG configuration
failure for RRC message on SRB3 and SCG integrity check failure
How we can identify SCGFailureInformation from 3GPP specs

SCGFailureInformation

The SCGFailureInformation message is used to provide information regarding NR SCG failures


detected by the UE.

Signalling radio bearer: SRB1

RLC-SAP: AM

Logical channel: DCCH

Direction: UE to Network

TYPE OF SCG Failure Reason

1. t310-Expiry
2. synchReconfigFailure-SCG
3. randomAccessProblem
4. rlc-MaxNumRetx
5. srb3-IntegrityFailure
6. scg-reconfigFailure
SCGFailureInformationNR

failureType- Any allowed t310-Expiry, OR randomAccessProblem, OR rlc-MaxNumRetx, OR synchRe


r15 value OR scg-reconfigFailure, OR srb3-IntegrityFailure

Time
start stop expiry
r

For T304 of MCG,


handover from NR
handover, initiate t
reestablishment pro
Upon reception of
Upon successful completion of random handover to NR, pe
RRCReconfiguration message
t304 access on the corresponding SpCell For defined in the spec
including
T304 of SCG, upon SCG release for the source RAT
reconfigurationWithSync
inform network abo
reconfiguration wit
initiating the SCG
procedure as specif

If the T310 is kept


Upon receiving N311 consecutive in-sync security is not activ
Upon detecting physical layer indications from lower layers for the SpCell, RRC_IDLE else: in
problems for the SpCell i.e. upon upon receiving RRCReconfiguration with connection re-estab
t310 receiving N310 consecutive out- reconfigurationWithSync for that cell group, procedure. If the T
ofsync indications from lower and upon initiating the connection re- Inform E-UTRAN/
layers. establishment procedure. Upon SCG release, radio link failure by
if the T310 is kept in SCG. failure information
specified in 5.7.3.

How to improve scg failure in


network.

RLC-Config
The IE RLC-Config is used to specify the RLC configuration of SRBs and DRBs.

 srb3-IntegrityFailure
UE initiates transmission of the SCGFailureInformationNR message due to SRB3 integrity
check failure

 scg-reconfigFailure
UE initiates transmission of the SCGFailureInformationNR message due to Reconfiguration
failure of NR RRC reconfiguration message.

During the SCG failure , UE also report the available measurement result under
I(measResultFreqListNR-r15 and measResultSCG

You might also like