Paddle Feeder (PF) Stage-1: Function
Paddle Feeder (PF) Stage-1: Function
The Axial Piston Pump Is Equipped with an Electrical Remote Control Adjustment Unit
Complete with Pilot Motor (Servo).This Servo Motor Is Controlled By Means Of A
Reversible Rotary Field. It Changes The Slewing Angle Of The Axial Piston Pump, And
Therefore The Oil Delivery Rate, Which Determine The Rotation (Speed) Of The Oil Motor.
The Remote Control Adjustment Unit Is Fitted With Two Contacts With A Minimum
Conveying Capacity Of 10% And Maximum 100%.
The Contacts Will Open When Actuated By Switching Cam, And Switched Off The Control
To Permit Capacity Adjustment Within 10% - 100% Range.
TRAVEL DRIVE
During Discharging, The RDM Drives With Constant Speed Along The Bunker Slot.
The Travel Drive Powers Both Axils –(All 4 Wheels Are Driven) From A 3ph Reversible
Sq.Cage Induction Motor Through A Fluid Drive Coupling , A Worm Gear Spur Wheel
Reducer And Two Pairs Of Bevel Wheels.
During Operation The Machine Moves Along The Bunker Slot At A Constant Speed And
Automatically Reverses Its Direction Of Travel At The End Of The Bunker By Actuating
The Respective End/Turn Limit Switches.
2
1. The First Contact Closes When The Reversing Pressure Which Is Lower Than The
Switch Off Pressure Is Reached The RDM Stops, Reverses Its Direction Of Travel,
Stops Again After Preset Time And Returns To Its Original Direction.
2. The Second Contact Opens When The Preset Switch Off Pressure Is Reached, And
Switches The RDM Off
3. The Pressure Switch For The Return Filter Will Give A Warming Indication When
The Filter Is Clogged
B) Oil Level- For Oil Level Indication There Are Two Float Switches
1. If Oil Level Drops Significantly Below The Normal Oil Level A Warning Is Given
2. If The Oil Level Continues To Fall I.E. On A Value Below The Minimum
Admissible Level The Machine Is Automatically Switched Off
3) The Servo Motor of Discharge Wheel Drive Must Be On The 10% Minimum Capacity
Control
LOCAL CONTROL
Move The Key Operated Switch To Local Control Position. Acknowledged By Indicator
Lamp After Meeting The Above Condition Activates The Start Button. This Will Cause The
Pump Motor To Start Operating And The Discharge Wheel To Move At Its Minimum Speed
Rate Of10%.This Function Is Displayed By Illumination Of The Machine Running Lamp.
3
1) Stop Button
If Switch Off Occurs Due To Stop Button This Function Displayed By Machine Stop Lamp
Illuminates
FAILURE
2) Over Pressure
In All Cases The Control Motor Of The Adjustment Unit Will Move The Hydraulic Pump To
The 10%Minimum Capacity Contact As Soon As The Pump Motor Is Switched Off
OPERATION
Following The Stop, Before the Next Start Can Be Accomplished The Following Steps Must
Be Done
Pump Positioning Motor Alone Will Start and Drive the Pump Swash Plate until the
Minimum Limit Switch On The Top Of the Pump Is Activated
The Discharge Wheel Can Only Restarted, If the Basic Requirements Are Fulfilled
4
The Instantaneous Discharge Wheel Speed Rate Is Picked Up A Proximity Switch “Actual
Value” With An Output Frequency Proportionate To The DW Rpm-Rate .For Further
Processing These Square –Topped Pulses Are Transferred To An Electronic Pc Card In The
Comptronic Which Converts The Pulses In To A
4-20 Ma Current .This Current Used to Indicate the Capacity in Percentage on the Local
Control Cubic.
If Direction Travel Reversed The Travel Drive Left/Right Switch Must Be Toggled In To
The Defined Direction. The Rdm Comes To Halt And The “Direction Of Travel “Display
Lamp Extingushes after About 5seconds The Other Direction Of Travel Lamp Will Light Up
And The rdm Will Travel Into The Direction Selected. As The Distance of Travel Limited by
Limit switches.The Respective Limit Switches Are Actuated during Automatic reverse Of the
Travel Direction
A Safety Limit Switch Is Provided In Case The Normal Limit Switch Is Over Travelled Due
To A Fault The Travel Drive Of Machine Is Switched Off And Travel Direction Lamp
Extinguishes.
In Order To Restart The Travel Drive The Opposite Direction Of Travel Must First Be Set By
Means Of The Travel Drive L/R Spring Back Switch.This Must Be Followed By Pressing
The “Reset” Button.
5
FAULT INDICATIONS
Warning- Yellow Lamp
Fault Displayed .1) Filter Clogged –Will Not Lead Total Shutdown
HYDRAULICTANK
SPECIFICATION-
Gear Oil-Vg-220
Hydraulic Oil Vg 68
Oil Quantity-550litres
No. of Arms-6
Capacity-200 to 1000tph
Rpm-2.3 To 15.2