SHH TYPE CHAIN ELECTRIC HOIST

Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005410 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed


1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ
Visually inspect the ground wire and ground screw,
f.Ground Resistance and use a digital bridge to detect that the resistance 0.020 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω
No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.3 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.2-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-3.2 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 73 75

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Over Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005411 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed


1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between 500 MΩ Passed
the motor lead and the housing is not less than 1.5MΩ
Visually inspect the ground wire and ground screw,
f.Ground Resistance and use a digital bridge to detect that the resistance 0.026 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω
No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.3 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.3 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 73

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test


1.6 slip clutch start work under Passed
Over Load Test load, safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date
TBM SHH2 500/1-16-
51083938 2005412 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed


1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 12.0MΩ Passed
motor lead and the housing is not less than 1.5MΩ

Visually inspect the ground wire and ground screw, and


f.Ground Resistance use a digital bridge to detect that the resistance between 0.019Ω Passed
the ground wire and the housing is not greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.3 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.2 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 73

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load within
1.4 visual inspected less than 200mm Passed
brake decline the rated lifting speed lifting distance),and less than
200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of Over When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift and lift and in static condition in 10 minutes Passed
in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005413 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed


1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between 500 MΩ Passed
the motor lead and the housing is not less than 1.5MΩ
Visually inspect the ground wire and ground screw,
and use a digital bridge to detect that the resistance
f.Ground Resistance 0.020 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω
No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.3 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.2 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 74

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Over Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date
TBM SHH2 500/1-16-
51083938 2005414 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed


1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ
Visually inspect the ground wire and ground screw,
f.Ground Resistance and use a digital bridge to detect that the resistance 0.016 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω
No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.3 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.3 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.2 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 74

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of Over When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date
TBM SHH2 500/1-16-
51083938 2005415 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed


1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ
Visually inspect the ground wire and ground screw,
f.Ground Resistance and use a digital bridge to detect that the resistance 0.019 Ω Passed
between the ground wire and the housing is not greater
than 0.1Ω
No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.3 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 74

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of Over When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005416 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed


1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ
Visually inspect the ground wire and ground screw,
and use a digital bridge to detect that the resistance
f.Ground Resistance 0.022 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω
No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.3 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.3 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.2-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 74

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Over Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date
TBM SHH2 500/1-16-
51083938 2005417 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between 500 MΩ Passed
the motor lead and the housing is not less than 1.5M
Ω
Visually inspect the ground wire and ground screw,
and use a digital bridge to detect that the resistance
f.Ground Resistance 0.025 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 74

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test


1.6 slip clutch start work under Passed
Over Load Test load, safety slip clutch start work

Under the Condition of Rated Voltage, rated


1.7 Dynamic Load Test frequency and 1.1-1.25 times the rated load,winch is lift and in static condition in 10 minutes Passed
able to lift and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005418 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1 d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ

Visually inspect the ground wire and ground screw, and


use a digital bridge to detect that the resistance
f.Ground Resistance 0.019 Ω Passed
between the ground wire and the housing is not greater
than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.2 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 74

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of Over When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005419 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ
Visually inspect the ground wire and ground screw, and
use a digital bridge to detect that the resistance
f.Ground Resistance 0.026 Ω Passed
between the ground wire and the housing is not greater
than 0.1Ω
No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.4-2.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 75 75

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Over Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005420 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ
Visually inspect the ground wire and ground screw,
and use a digital bridge to detect that the resistance
f.Ground Resistance 0.025 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.3 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.3 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.2 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 73

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Over Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005421 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1 d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ

Visually inspect the ground wire and ground screw,


and use a digital bridge to detect that the resistance
f.Ground Resistance 0.019 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.3 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.3 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.2 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 74

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Over Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005422 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1 d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


insulation resistance at room temperature between
e.Insulation 500 MΩ Passed
the motor lead and the housing is not less than 1.5M
Ω
Visually inspect the ground wire and ground screw,
and use a digital bridge to detect that the resistance
f.Ground Resistance 0.019 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.4-1.3 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.3 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.3 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 74

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test


1.6 slip clutch start work under Passed
Over Load Test load, safety slip clutch start work

Under the Condition of Rated Voltage, rated


1.7 Dynamic Load Test frequency and 1.1-1.25 times the rated load,winch is lift and in static condition in 10 minutes Passed
able to lift and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005423 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1 d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ

Visually inspect the ground wire and ground screw,


and use a digital bridge to detect that the resistance
f.Ground Resistance 0.020 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.3 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.3 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.3 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 72

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Over Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005424 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1 d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between 500 MΩ Passed
the motor lead and the housing is not less than 1.5MΩ

Visually inspect the ground wire and ground screw,


and use a digital bridge to detect that the resistance
f.Ground Resistance 0.019 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 72

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of Over When 1.3-1.6 times the nominal weight of the test
1.6 slip clutch start work under Passed
Load Test load, safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift lift and in static condition in 10 minutes Passed
and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005425 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1 d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


e.Insulation insulation resistance at room temperature between the 500 MΩ Passed
motor lead and the housing is not less than 1.5MΩ

Visually inspect the ground wire and ground screw, and


use a digital bridge to detect that the resistance
f.Ground Resistance 0.020 Ω Passed
between the ground wire and the housing is not greater
than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.3 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.3 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.2 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 75

Rated voltage,rated frequency and nominal weight,the


b.The distance of decline should be less than v/100(v=1 minute load
1.4 visual inspected less than 200mm Passed
brake decline within the rated lifting speed lifting distance),and less
than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test load,
1.6 slip clutch start work under Passed
Over Load Test safety slip clutch start work

Under the Condition of Rated Voltage, rated frequency


1.7 Dynamic Load Test and 1.1-1.25 times the rated load,winch is able to lift and lift and in static condition in 10 minutes Passed
in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005426 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1 d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


insulation resistance at room temperature between
e.Insulation 500 MΩ Passed
the motor lead and the housing is not less than 1.5M
Ω
Visually inspect the ground wire and ground screw,
and use a digital bridge to detect that the resistance
f.Ground Resistance 0.012 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.3 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.4-1.3 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.3 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.4-2.2 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.2 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 74

Rated voltage,rated frequency and nominal


b.The distance of weight,the decline should be less than v/100(v=1
1.4 visual inspected less than 200mm Passed
brake decline minute load within the rated lifting speed lifting
distance),and less than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of Over When 1.3-1.6 times the nominal weight of the test
1.6 slip clutch start work under Passed
Load Test load, safety slip clutch start work

Under the Condition of Rated Voltage, rated


1.7 Dynamic Load Test frequency and 1.1-1.25 times the rated load,winch is lift and in static condition in 10 minutes Passed
able to lift and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005427 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1 d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check that the


insulation resistance at room temperature between
e.Insulation 500 MΩ Passed
the motor lead and the housing is not less than
1.5MΩ
Visually inspect the ground wire and ground screw,
and use a digital bridge to detect that the resistance
f.Ground Resistance 0.025 Ω Passed
between the ground wire and the housing is not
greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.3 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.1 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.2 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 73

Rated voltage,rated frequency and nominal


b.The distance of weight,the decline should be less than v/100(v=1
1.4 visual inspected less than 200mm Passed
brake decline minute load within the rated lifting speed lifting
distance),and less than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the test


1.6 slip clutch start work under Passed
Over Load Test load, safety slip clutch start work

Under the Condition of Rated Voltage, rated


1.7 Dynamic Load Test frequency and 1.1-1.25 times the rated load,winch is lift and in static condition in 10 minutes Passed
able to lift and in static condition in 10 minutes

Limit Bezel Can Reset with the Chain after the Limit
1.8 Limit Bezel limit bezel can reset Passed
Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005428 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

d.Sign and Notice available and complete complete and available Passed
1.1

Use an insulation resistance meter to check that


the insulation resistance at room temperature
e.Insulation 500 MΩ Passed
between the motor lead and the housing is not
less than 1.5MΩ

Visually inspect the ground wire and ground


screw, and use a digital bridge to detect that the
f.Ground Resistance 0.016 Ω Passed
resistance between the ground wire and the
housing is not greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.2 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 73 73

Rated voltage,rated frequency and nominal


b.The distance of weight,the decline should be less than
1.4 visual inspected less than 200mm Passed
brake decline v/100(v=1 minute load within the rated lifting
speed lifting distance),and less than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the


1.6 slip clutch start work under Passed
Over Load Test test load, safety slip clutch start work

Under the Condition of Rated Voltage, rated


frequency and 1.1-1.25 times the rated
1.7 Dynamic Load Test lift and in static condition in 10 minutes Passed
load,winch is able to lift and in static condition
in 10 minutes
Limit Bezel Can Reset with the Chain after the
1.8 Limit Bezel limit bezel can reset Passed
Limit Touched off
SHH TYPE CHAIN ELECTRIC HOIST
Customer:Suzlon
ZHEJIANG SHUANGNIAO MACHINERY CO.,LTD.(TBM)
PARTS:SHH2 500/1-16-150M 400V 50HZ Winch for Suzlon S111 WIND TURBINE
TEST REPORT
SAP Code Description Serial No. PO.No. GRN.No. Quantity No. Inspection Date

TBM SHH2 500/1-16-


51083938 2005429 5300010161 1 20.May,2020
150M

Check Points Standard Specifications Observation Result

a.Visual Inspection surface of powder-coated No Damage Passed

b.Hook hook flexibility under 360 rotation Flexible Passed

c.Lifting Chain case of disjointed or stuck No Passed

1.1
d.Sign and Notice available and complete complete and available Passed

Use an insulation resistance meter to check


that the insulation resistance at room
e.Insulation 500 MΩ Passed
temperature between the motor lead and the
housing is not less than 1.5MΩ
Visually inspect the ground wire and ground
screw, and use a digital bridge to detect that
f.Ground Resistance 0.018 Ω Passed
the resistance between the ground wire and
the housing is not greater than 0.1Ω

No-Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 1.3-1.2 U1 1/V / I1 1/A /


1.2 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 1.3-1.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 1.3-1.2 U3 3/V / I3 3/A /

Rated Load Test U FAST Voltage I FAST UP-DOWN U SLOW Voltage I SLOW UP-DOWN Passed

U1/V 400 I1/A 3.3-2.1 U1 1/V / I1 1/A /


1.3 Voltage and Current
Values Recorded(Up U2/V 400 I2/A 3.3-2.2 U2 2/V / I2 2/A / Passed
and Down)
U3/V 400 I3/A 3.3-2.1 U3 3/V / I3 3/A /

Load less than 1T,noise level<82dB; move up move down


a.Noise Test Passed
greater than 1T,noise level<85dB; 74 73

Rated voltage,rated frequency and nominal


b.The distance of weight,the decline should be less than
1.4 visual inspected less than 200mm Passed
brake decline v/100(v=1 minute load within the rated lifting
speed lifting distance),and less than 200MM.

c.Motor Running Operation in Normal and Any Noise in normal operation without noise Passed

d.Gearbox Normal Operation and Noise Level in normal operation without noise Passed

1.5 Voltage drop test Under 90% of Rated voltage,three times Lift lift three times in the air Passed

Performance of When 1.3-1.6 times the nominal weight of the


1.6 slip clutch start work under Passed
Over Load Test test load, safety slip clutch start work

Under the Condition of Rated Voltage, rated


frequency and 1.1-1.25 times the rated
1.7 Dynamic Load Test lift and in static condition in 10 minutes Passed
load,winch is able to lift and in static condition
in 10 minutes
Limit Bezel Can Reset with the Chain after the
1.8 Limit Bezel limit bezel can reset Passed
Limit Touched off

You might also like