TEST INSTRUCTIONS

Page 1 von 3
Slewing Bearing Maximum allowable
wear

Procedure: Check Slewing Bearing Wear

Instructions:

1. Set-up crane level on the Outriggers


2. Telescopic Boom completely retracted
3. Measurements should be conducted with recommended counterweight (see Table1)
4. Use Dial Indicator with1/100 mm increments and a magnetic base
5. With boom @ 75° set indicator to zero, boom down to 5°
6. Read displacement according to the indicator
7. Four measurements taken at intervals of 90° slewing position
8. Document your results
9. Record the operating hours
10. Describe crane configuration

Repeat test conducted by Service Department:

11. Attention: When repeat test are conducted the crane must be configured the same as the
original test for comparison purposes
12. Maximum Wear (increased Bearing Play after base measurement) see Table 2

Manufacturer / Type Dial Indicator


Of Slewing Bearing with Magnetic
Base
FAUN Part Number

Serial Number

June 2008
Slewing Bearing Wear Page 2 of 3

Crane Serial Number:

Slewing
Bearing
right
Results: 2

Operating Hours:
front rear
Position 1: 1 3

Position 2:
4
Position 3: left

Position 4:

Crane configuration during test:

Counterweight t

Hookblock t

Folding Jib mounted


On the side of the yes no
Boom

Comments:

Date:

Name / Signature
Slewing Bearing Wear Page 3 of 3

Counterweight to be attached to the crane:

Table 1
ATF 30-2L ATF 40G-2 ATF 45-3 ATF 60-3 ATF 65G-4 ATF 80-4 ATF 90G-4 ATF50G-3
FA 023 FA 040 FA 012 FA 022 FA 031 FA 043 FA 045 FA 042

2,2 t 1,5 t 2,0 t 3,4 t 2.28 t 2,8 t 5,2 t 4,9t

ATF 110G-5 ATF 160G-5 ATF 220G-5 BKF 35-4 / BKF 40-4 HK 40 HK 60
FA 035 FA 029 FA 036 FA 014 / FA 030 FA 039

1,1 t 1,1 t 0t 0t 4,5 t 8,4 t

Table 2
ATF 30-2L ATF 40G-2 ATF 45-3 ATF 60-3 ATF 65G-4 ATF 80-4 ATF 90G-4 ATF50G-3
FA 023 FA 040 FA 012 FA 022 FA 031 FA 043 FA 045 FA 042

1,7 mm 1,7 mm 1,7 mm 2,6 mm 2,6 mm 2,3 mm 2,3 mm 2,0 mm

ATF 110G-5 ATF 160G-5 ATF 220G-5 BKF 35-4 / BKF 40-4 HK 40 HK 60
FA 035 FA 029 FA 036 FA 014 / FA 030 FA 039

2,9 mm 2,9 mm 2,9 mm 1,7 mm 1,7 mm 2,6 mm

Conduct repeat measurements per instructions on Page 1!

Operating Hours Comments:

Position 1

Position 2

Position 3 Date:

Position 4 Name / Signature

Operating Hours Comments::