Coiled Tubing

CALCULOS MINIMOS DE CT
Como Determinar el Stretch debido
al peso en FT

S =0.0567 * (PROF./1000)2

EJEMPLO

S = 0.0567 * (12000 FT / 1000)2

S = 8.1648 FT

“Confidential - For Internal Use Only. © 2005 Halliburton. All Rights Reserved.”
Coiled Tubing

CALCULOS MINIMOS DE CT
Como Determinar MAXIMA TENSION

T = ( OD 2 – ID 2) * 0.7854 * YIELD * SF

T = (1.752 – 1.438 2) * 0.7854 * 80000 * 0.8 =

T = 49997 LBS

“Confidential - For Internal Use Only. © 2005 Halliburton. All Rights Reserved.”