S-21 - Connection Details

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NOTES

1. All dimensions are in Feet & Inches unless


otherwise stated.
2. Do not scale from this drawing use
figured dimensions only.
3. All reinforcement steel strengths
designated on drawings to conform with
ASTM A615/A615M or equivalent as
follows:
T - High tensile steel,ASTM grade 60
(fy = 420MPa) .
R - Mild steel,ASTM grade 40

W14 x 48/
(fy = 280MPa).
4. Concrete cover to reinforcement to be as
follows:
Foundations - 50mm above conc.

W8 x 35
blinding.
1"

Ground Beams - 50mm;75mm on soil


surface.
5. Rebar laps shall be provided where
applicable to suit construction logistics.
Minimum steel reinforcement lap lengths:
10mmØ=500mm.
12mmØ=600mm.
16mmØ=750mm.
20mmØ=910mm.
2" 312" 2" 6. All structural drawings to be verified with
Architectural details. Any discrepancies
to be brought to the attention of the

1 16"
7 Engineer.
7. Contractor to verify all dimensions
prior to construction.

8. All concrete to be supplied and


installed in accordance with American

2"
Concrete Institute ACI 318 Building
Code Requirements for Structural
Concrete or other equivalent and

212"
approved standard.
9. Concrete shall be mechanically
compacted in the approved manner.

512"
10. Methodology of curing concrete to be
approved by the supervising Engineer.
11. All rebars in block work to be
inspected before grouting and to be free
of debris, loose mortar etc.

2# 58" Thk. plate welded to 1-1/4"Ø A325 bolts


column flange using 8mm Thk.

1'-912"
612"
fillet weld and to column web
6mm arc fillet weld

212"
512"
1" Thk. Gr.50 end plate welded
to beam flange using CJP

2"
groove weld and 6mm arc fillet
weld to column web

W12 x 35
712"

ENDPLATE DETAIL 'D-D'

D
W14 x 48/
W8 x 35

- W12x26/W12x30 BEAM TO W12x35 BEAM


SHEAR CONNECTION DETAIL -

JOB TITLE:
DRAWING TITLE: DWG NO: CONSULTANT

CIVPRO ENGINEERING RENOVATION TO HEAD OFFICES CONNECTION DETAILS S-21


LIMITED LOT#M2, CENTURY DRIVE, ETECK
T
:el 8(64
89
)10-809 TRINCITY INDUSTRIAL PARK, MACOYA. JOB NO.: ----- DRAWN: NS
E
:mlai civprott@gmail.com DATE: 11.10.20 CHECKED: NmS A 11.10.20 FIRST ISSUE NmS
CLIENT: BARAD
H
AOLD
N
IG
L
S
TD
SCALE: AS SHOWN DESIGN: NmS ISSUE DATE DESCRIPTION INIT. ISSUE DATE DESCRIPTION INIT.