Professional Documents
Culture Documents
Displacement Response To Axial Cycling of Piles Driven in Sand
Displacement Response To Axial Cycling of Piles Driven in Sand
Displacement Response To Axial Cycling of Piles Driven in Sand
A review of the load applied to multi-pile offshore wind turbine foundations is presented, from which the need to
consider the response to axial cyclic loading is emphasised. The paucity of available data on field tests on driven
piles in sand is noted. A comprehensive data set of multiple axial cyclic and static tests conducted on seven
industrial-scale steel pipe-piles at a marine sand site in Dunkerque, France, is re-examined in this paper. The effects of
cycling on axial capacity are interpreted by reference to stable, metastable or unstable zones defined in a normalised
cyclic stability interaction diagram. A detailed analysis is made of the load–displacement and stiffness response
associated with each mode of cycling. It is shown that in all cases the piles’ cyclic stiffnesses show only minor
changes until cyclic failure is approached. The patterns of permanent cyclic strain accumulation are sensitive to the
applied mean and cyclic loading levels. Whereas displacements accumulate rapidly over just a few cycles in the
unstable zone, extended cycling in the stable zone leads to minimal accumulated displacements and constant
transient cyclic displacements.
1
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
comparison with self-weights, leading to multiple modes of axial turbines and conventional oil and gas jackets. For example, tension
and lateral cyclic loading acting on the foundation piles. While is more critical for Case G, of a tripod wind turbine founded in
lateral loading model test data have been reported for monopiles sand, and it could also be with some wind turbine jacket structures
(Leblanc et al., 2010), less guidance is available regarding full- in deeper water.
scale displacement accumulation and stiffness responses under
axial cycling. Jardine et al. (2012) summarised data from field investigations
involving the response to axial cyclic loading of steel piles; they
Jardine et al. (2012) reviewed the potential effects of cyclic noted 14 case histories in clay and only one in silica sands at
loading on offshore piles, and considered how these may be Dunkerque, France, reported by Jardine and Standing (2000,
addressed in practical design. They outlined the indicative ranges 2012). As described by Merritt et al. (2012), cyclic pile behaviour
for cyclic loading components that might apply to the range of under the first few hundred cycles represents the most critical
multiple pile structures listed in Table 1, noting that the loads vary condition to be satisfied in design, and the Jardine and Standing
with platform weight, water depth, metocean environment, and (2000) tests represent the only field study of which the current
structural form. In these examples the worst storm events (100- authors are aware that investigates such behaviour up to 1000 cy-
year return period for oil/gas and 50-year return period for wind cles. More extended tests on sands have been performed in
energy) set the design-critical conditions. Following the cyclic laboratory centrifuges (Puech et al., 2012) and calibration
loading convention in Figure 1, the average ratio of Qcyclic /Qmean chambers (Tsuha et al., 2012), and are planned for a secondary
on the windward side is around 7.8, and that on the leeward is just campaign of full-scale tests at Dunkerque (Puech et al., 2012).
above 1.0, the limiting value for the pile loads to become tensile.
The maximum compressive loads developed on the leeward side, A range of analytical techniques that can be applied in axial
Qmax ¼ Qmean + Qcyclic , usually constitute the critical conventional cyclic design were set out by Jardine et al. (2012), and Merritt et
design case, although this may alter after accounting for cyclic al. (2012) described a practical application to a wind farm
loading effects. Cyclic effects may be more marked for the tensile founded in sand. Both papers emphasise the use of interactive
load cases, but there are broad spreads of ratios between both wind cyclic stability diagrams to guide the assessment of global axial
cyclic load capacity degradation for driven piles, as advocated
Q previously by Karlsrud et al. (1986), Poulos (1988) and Jardine
Cyclic period, T and Standing (2000). These cyclic stability diagrams consider the
interaction effects of cyclic and mean loads (normalised by static
Qmax capacity before cycling) and the number of cycles applied. Such
Qcyclic ! (Qmax " Qmin)/2 interaction diagrams may be zoned to identify a cyclically stable
Qmean ! (Qmax # Qmin)/2
Qcyclic
(S) region where there is no reduction of load capacity after N
cycles, a metastable (MS) area where some reduction of load
capacity occurs after N cycles, and an unstable (US) zone where
Qmean
cyclic failure develops within a small specified number of cycles.
O Time Tsuha et al. (2012) proposed quantitative definitions for the three
Qmin zones when reporting model pile tests in silica sand. They also
provided insights into the interface shear behaviour and sand
Figure 1. Load–controlled axial cycling illustrated (Tsuha et al., mass response to cyclic pile loading. Jardine and Standing (2012)
2012) applied a similar scheme in interpretation of their field tests at
Dunkerque (Figure 2). Stable cyclic responses were associated
Jacket code, location and type Water depth: m Leeward Qcyc /Qmean Windward Qcyc /Qmean
2
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
Qcyclic /QT
Qcyclic /QT
13
24 Set 3
MS 206 0·4 Metastable
0·4 9 1 N
$221 27 f !
10
3 0
$200 Nf !
S 345 100
Set 2 0·2 0
0·2
$1000
Set 1 Stable
0 0
"0·2 0 0·2 0·4 0·6 0·8 1·0 0 0·2 0·4 0·6 0·8 1·0
Qmean /QT Qmean /QT
Figure 2. Axial cyclic interaction diagram for full-scale pile tests in Figure 3. Illustration of potential cyclic effects for WSD FoS ¼ 1.5
Dunkerque silica marine sands (Jardine and Standing, 2012) design conditions compared with Dunkerque contours of stable,
metastable and unstable condition in normalised cyclic interaction
diagram
3
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
have been reported by Jardine and Standing (2000, 2012), and sands’ particle size distributions (PSD) are shown in Figure 7,
Jardine et al. (2006) reported the piles’ remarkable static tension and other index properties are given in Table 2. Summary
capacity–time trends. Chow (1997) reported static and cyclic tests observations are given in Table 3 regarding the site-specific
at the same site with the ICP (Imperial College pile) pile, which laboratory characterisation reported by Chow (1997), supplemen-
carries pore pressure sensors. The pore pressures showed a fully ted by extensive advanced laboratory testing by Kuwano (1999).
drained response. Although this is also expected at field scale with Jardine et al. (2005b) showed that the piles’ static load–displace-
large piles in clean sands, partially drained behaviour might apply ment characteristics can be reproduced with reasonable accuracy
in lower-permeability deposits, as may be checked by inspecting by non-linear finite-element analyses based on
piezocone data and applying consolidation analyses.
(a) the non-linear laboratory stiffness data
3. Test site (b) local shaft stress distributions assessed through the ICP
Jardine et al. (2006) and Jardine and Standing (2012) detailed the procedures (incorporating allowance for pile–soil interface
test piles’ layout plan (Figure 4), pile tension testing set-up slip, as described by Jardine et al., 2005a)
(Figure 5), and geotechnical profiling, which included multiple (c) allowance for the pile ageing behaviour.
cone penetrometer test (CPT), DMT and seismic soundings as
well as extensive laboratory tests on samples from a 26 m deep 4. Scaling of tests
borehole. The site profile (Figure 6) consists of 3 m of hydraulic Any application of the cyclic pile test results should consider
marine sand fill overlying an extensive depth of Flandrian marine how they may scale to the problem in hand. The key points to
sand deposited over three local transgressions between 2100 and consider are the pile slenderness ratio L/D, and the effective axial
900 years BP (Sommé, 1969). The Dunkerque profile includes an stiffness of the piles compared with the shear stiffness of the soil
organic layer between 7.6 m and 8.2 m, associated with sea-level mass. The pile stiffness depends on the steel modulus, the pile
transgressions, and two further, deeper organic bands. The CPT wall thickness (t ) and outside diameter. Pile C1 had an L/D # 22,
qc tip resistances vary with depth between 10 and 35 MPa, whereas R1 to R6 had L/D # 42. The latter L/D value is typical
averaging around 21 MPa over the 19 m pile lengths. The ground- of many offshore jacket piles, but lower values are typical for
water table was reported at 4 m, showing no tidal variations. The monopiles and possibly for multi-pile wind turbine structures. All
the test piles had D/t ratios of 33.8 over most of their embedded
lengths, which may be typical of jacket structures, but are low for
N wind turbine installations (Jardine, 2008; Merritt et al., 2012).
The Dunkerque conditions may be typical for southern North Sea
R3 R6
sites, but greater stiffness can be expected at denser sand sites,
where qc values exceed 50 MPa.
A A
CPT R5-6 In cases where the pile make-up and soil stiffness characteristics
CPT R2-3 JP1 are clearly different, the global cyclic stability diagrams can be
CPT GP1.B reformulated to consider local cyclic degradation processes
through a cyclic T–z approach, as summarised for example by
Insitut R5
Puech et al. (2012) and applied to the Dunkerque case by Atkins
R2
Pasteur Consultants Ltd (2000) using an approach such as that outlined in
the ICP design procedures (Jardine et al., 2005a), and detailed in
B CPT C1 B Jardine and Standing (2012).
C1
CPT R4-5
5. Test programme
CPT R1-2
The cyclic testing programme performed is detailed in Table 4.
Note that only static tests were performed on pile R1. Pile-head
R1 R4
loads were controlled by an automated hydraulic system and
beam arrangement supplied by Precision Measurement and Con-
trol (PMC) Ltd of Teesside UK (Jardine et al., 2006). The loads
applied were measured through a high-quality load cell, and
displacements were monitored by four LVDTs fixed to reference
beams supported by steel poles driven at least 3 m away from the
0 2 4 8 12 m
reaction system (Figure 5). The axial cyclic loading was con-
Figure 4. Plan showing layout of test and reaction piles and CPTs trolled by a regulator that imposed near-sinusoidal waves with
from GOPAL project in Dunkerque, France (after Jardine and maxima and minima that could be controlled to within $5 kN
Standing, 2012) over long-duration tests. The cyclic rates ranged between 1 and
2 min per cycle, depending on the pile response.
4
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
PMC
tension
head
400 mm
500 t
914 % 419 hydraulic
5·3 m long jack and
L-beam load cell 400 mm
914 mm
914 mm
1400 mm
6m%1m
ground 200 mm
panel
Displacement
and reference 500 mm
Levelled
system
sand
6m
(a)
Tension
head Load-
spreading
beams
914 % 419
6m 5·3 m long
L-beam
Displacement
and reference
system
6m
(b)
The test code sequence given in Table 4 refers to the testing loads are termed ‘one-way’, and tests where cycles ranged from
phase (of which there were three), the pile identifier (e.g. R2), tension to compression are referred to as ‘two-way’; tension loads
and then the test type (CY ¼ cyclic, T ¼ static tension) and and upward displacement responses are taken as positive through-
number of tests for the respective pile. No cycling was conducted out. Definitions relating to cyclic loading are shown in Figure 1.
in phase 1. The cyclic programme was organised into two Reference static tension tests to failure (T) were conducted after
campaigns: phase 2, October–November 1998; and phase 3, April most of the cyclic tests. These were performed to assess the
1999. The load-controlled tests involving only tensile pile-head effects of the applied axial cyclic loading on the operational static
5
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
4 GWL
Dense with shell fragments
6 (Flandrian sand)
8 Organic layer
shell fragments
12 (Flandrian sand)
14
16
18
22
24
Sand
tension (shaft) capacity. The static tests similarly served to isolate
Silt Gravel
Fine Medium Coarse any effects of previous (static or cyclic) loading phases from the
100
90 current axial cyclic behaviour. Table 5 summarises the load test
80 capacities.
% finer by weight
70
60
50
6. Results and interpretation
40 6.1 Cyclic failure criteria
30 Following Tsuha et al. (2012) and Jardine and Standing (2012),
20
the axial cycling displacement responses are classified as stable,
10
metastable or unstable, applying the following criteria.
0
0·01 0·1 1 10
Particle size: mm
(a) Stable (S): Low and stabilising accumulated axial
Figure 7. Particle size distributions envelope of Dunkerque sand displacements that remain below 0.01D and show slow rates
(after Jardine and Standing, 2000) of change (< 1 mm/1000 cycles) up to N > 1000 without
causing any loss of operational static shaft capacity.
2.656 84 8 8 19.9 75
6
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
K0 consolidated undrained (CK0 U) triaxial stress path tests (K0 ¼ 0.35), ID ¼ ,75% Compression $9p ¼ 378 Kuwano
Extension $9p ¼ 358 (1999)
Critical state $9cs ¼ 328
K0 consolidated undrained (CK0 U) triaxial stress path tests (K0 ¼ 0.35), shear modulus at Gcompression ¼ 111 MPa Kuwano
"s ¼ 0.005%, ID ¼ ,75% Gextension ¼ 230 MPa (1999)
Sand direct shear tests, # n9 ¼ 40–300 kPa $9cs ¼ 31.18 Kuwano
$9p ¼ 39.48 (1999)
Sand–mild steel interface (Rcla ¼ 9.8 !m) direct shear test !9p ¼ 30.88
!9cv ¼ 26.88
Aged sand–stainless steel interface (Rcla ¼ 9.8 !m) direct shear tests, 63 days’ ageing !9p ¼ 31.08 Chow (1997)
!9cv ¼ 27.58
No change of either !9cv or !9p with ageing. Creep densification, increased shear stiffness and stronger dilation with ageing supposedly from
microstructural rearrangement of the sand grains and their contacts.
(b) Metastable (MS): Axial displacements accumulate that increase to . 1 mm/10 cycles. Shaft capacity degradation
(0.01D , accumulated displacements < 0.1D) at moderate is potentially very significant.
rates (1 mm/1000 cycles , rates < 1 mm/10 cycles),
potentially leading to some degradation of the operational The cyclic tests are reported and analysed with reference to the
static shaft capacity, but not causing failure within 100 cycles. cyclic stability interaction diagram shown in Figure 2 from
(c) Unstable (US): Cyclic failure within 100 cycles, involving Jardine and Standing (2012). The static tension capacities varied
either accumulated permanent cyclic displacements . 0.1D with time and cyclic loading history. The reference QT values
or rates of accumulation of permanent cyclic displacements employed in Figure 2 are those applying at the time of testing.
7
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
to be small in sands, and the pile-loading cases are mapped into N!0 1 2...
Qmax
cyclic stability zones, which are assigned to conform broadly to
Pile-head load: kN
Qmin
The 14 load-controlled axial cyclic tests gave a range of d
outcomes, with one stable loading (set 1), four metastable
loading (set 2) and nine unstable loading (set 3) responses
Displacement: mm
indicated in Figure 2. In analysing the cyclic loading data,
displacements have been assessed in two ways. The permanent Figure 8. Illustration of stiffness and displacement parameters
accumulated cyclic displacement, shown as a in Figure 8, is used in analyses
cumulative, usually increasing with the number of cycles. It is
measured with respect to the Qmax point of the first cycle (see
Figures 1 and 8). The second measure of displacement, d, is the axial cyclic stiffness (defined in Figure 8) responses, permanent
transient cyclic displacement that occurs for each cycle, and accumulated cyclic displacements and the transient cyclic dis-
which may increase with cycling, especially under metastable placements evolved with number of cycles during cyclic loading
and unstable loading conditions. Analyses of how the piles’ are now presented.
8
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
6.2 Pile axial cyclic stiffness common to but stiffer than the lower ultimate capacity 19 m long
Figure 9 plots load–displacement results from slow, maintained- pile R1, which is stiffer than the shorter (10 m long) pile C1.
load, first-time tension tests for seven of the piles driven at
Dunkerque (i.e. tests 2.C1.T2, 1.R1.T1, 3.R2.T1, 2.R3.T1, The stiffness response under cycling is considered using the
2.R4.T1, 2.R5.T1 and 2.R6.T1 from Table 5). The initial maxi- variables defined in Figure 8. Note that different cyclic stiffness
mum reference secant stiffness kRef ¼ ˜Q/˜s is defined by values kl or ku may develop on the loading and unloading paths
considering the first load step applied (defined as QRef ), which of cyclic loading respectively. The loading cyclic stiffness values,
was 100 kN for C1 and 200 kN for R1 to R6. As noted by Jardine kl , are considered first in relation to the reference stiffness kRef ,
et al. (2005b), the piles’ load–displacement behaviour is highly as shown in Figure 11(a) (stable and metastable tests) and Figure
non-linear. In Figure 10 the piles’ secant stiffness non-linearity, 12(a) (unstable tests) to examine the evolution of the piles’
assessed from the first-time tension loading tests shown in Figure stiffness under axial cycling. Figures 11(b) and 12(b) show the
9, is represented by plotting the stiffnesses ratio, k/kRef , against same data, but with the kl values normalised by the loading
the ratio Q/QRef : Piles R2 to R6 (19 m long) show trends
1·0
3500
Ref. stiffness C1
3000 0·8
Tensile pile head load: kN
R1 Stable test
2500 R2 All other metastable tests
R3* Data not logged for
2000 Qcyc ! 0·34QT
R4* 0·6 the first 34 cycles
1500 R5*
kl /kRef
R6
1000
0·4 Qcyc ! 0·3QT
500
1·0
0·8 Stable test
0·6
R1
0·4
0·4
S 3.R4.CY6; Qcyc ! 0·2QT
MS 2.R3.CY2; Qcyc ! 0·3QT
0·2 R2–R6 0·2 MS 2.R4.CY2; Qcyc ! 0·34QT
MS 2.R5.CY2; Qcyc ! 0·3QT
MS 3.R6.CY6; Qcyc ! 0·42QT
C1 0
0 1 10 100 1000
0 5 10 15 20 Cycles, N
Q /QRef (b)
Figure 10. Stiffness degradation of piles assessed from the first- Figure 11. Axial cyclic loading stiffness (kl ) responses normalised
time axial static monotonic tension loadings normalised by the in terms of (a) kRef and (b) k N¼1 , plotted against number of cycles
reference stiffnesses plotted against load normalised by QRef for stable and metastable loading tests
9
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
1·0 US 3.R2.CY2 (0·40) US 2.R6.CY2 (0·36) applied in the cycle, the smaller the initial secant stiffness). The
US 2.R3.CY3 (0·46) US 2.R6.CY4 (0·36)
US 2.R4.CY4 (0·44) US 2.C1.CY3 (0·74)
two tests where cycling is applied at 0.3QT (MS 2.R3.CY2 and
US 2.R5.CY3 (0·35) US 2.C1.CY4 (0·72) MS 2.R5.CY2) follow roughly the same path, except that there is
US 2.C1.CY5 (0·66) some scatter in the early data of the latter test. The initial
0·8
normalised stiffness for the stable loading test where the cycling
All unstable tests is applied at 0.2QT (S 3.R4.CY6) is in fact slightly lower than the
0·6 value for the Qcyclic ¼ 0.3QT tests. It can be seen that continued
cycling leads to only a marginal stiffness decrease (12%) over
kl /kRef
US 3.R2.CY2 (0·40) US 2.R6.CY2 (0·36) The loading stiffness (kl ) degradation trends for the unstable tests
US 2.R3.CY3 (0·46) US 2.R6.CY4 (0·36)
US 2.R4.CY4 (0·44) US 2.C1.CY3 (0·74) (Set 3 in Figure 2) are shown in Figures 12(a) and 12(b). By
1·2
US 2.R5.CY3 (0·35) US 2.C1.CY4 (0·72) definition, all of these tests underwent cyclic failure and sudden
US 2.C1.CY5 (0·66)
stiffness degradation before reaching 100 cycles. However, those
1·0 piles that survived for longer than a few cycles retained their
All unstable tests
initial stiffness values until within a few cycles of final failure.
Slight variations are seen in the sharpness of the onsets to failure
0·8
under similar cyclic loading levels, perhaps as a result of the
complex testing sequences. Stiffness degradation can be seen
kl /kN!1
0·6 more clearly in Figure 12(b), where the loading stiffness kl values
are normalised by the initial cyclic stiffness k N ¼1 :
Figure 11(a) shows the results from the stable and metastable 6.3 Permanent accumulated cyclic displacements
axial cycling tests (sets 1 and 2 in Figure 2), with the Qcyclic value The permanent accumulated cyclic pile-head displacements for
for each test marked in the legend. For the metastable loading the stable and metastable loading tests are shown in Figure 14,
tests, the initial normalised stiffness values (i.e. kl /kRef at N ¼ 1) and Figure 15 refers to the unstable loading tests. Also shown in
clearly reduce as Qcyclic increases, as expected given the piles’ Figures 14 and 15 are reference lines relating to the rate of
non-linear static response (the greater the proportion of QT accumulated displacements – that is, 1 mm/100 cycles and 1 mm/
10
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
ku /kRef
ku /kRef
0·4 0·4
ku /kN!1
0·6 0·6
US 3.R2.CY2
0·4 0·4 US 2.R3.CY3
S 3.R4.CY6; Qcyc ! 0·2QT US 2.R4.CY4
US 2.R5.CY3
MS 2.R3.CY2; Qcyc ! 0·3QT US 2.R6.CY2
0·2 MS 2.R4.CY2; Qcyc ! 0·34QT 0·2 US 2.R6.CY4
MS 2.R5.CY2; Qcyc ! 0·3QT US 2.C1.CY3
MS 3.R6.CY6; Qcyc ! 0·42QT US 2.C1.CY4
US 2.C1.CY5
0 0
1 10 100 1000 1 10 100
Cycles, N Cycles, N
(c) (d)
10 cycles. The rate of permanent accumulated displacements for accumulated displacement rates . 1 mm/100 cycles, and did not
the tests can be compared with the slopes of the two reference fail before cycling was halted after N ¼ 200 cycles. Quick static
lines at any value of N. Low and stable permanent accumulated check tests on these piles indicated only minor losses in shaft
displacements were observed in the only stable loading test capacity due to cycling. The other two metastable loading cyclic
(3.R4.CY6), with averaged displacement rates , 0.1 mm over the tests, 2.R5.CY2 and 3.R6.CY6, continued until cyclic failure
first 100 cycles falling to negligible or even negative rates over occurred. The rates of permanent accumulated displacements in
the final few hundred cycles. The static tension capacity test 2.R5.CY2 were initially high (. 1 mm/10 cycles) but then re-
(3.R4.T7) performed after this stable cyclic series showed a gain duced, before increasing again to . 1 mm/10 cycles as cyclic
of 24.5% in peak tension capacity (with reference to test failure approached. However, 3.R6.CY6 started with slow rates
3.R4.T5, which defined the pre-test tension capacity). The that increased sharply to . 1 mm/10 cycles before a sudden and
metastable loading tests showed a range of possible behaviours. brittle cyclic failure. The loading applied in tests 2.R5.CY2 and
Tests 2.R3.CY2 and 2.R4.CY2 developed steady permanent 3.R6.CY6 resulted in a metastable response, as given by the
11
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
30
S 3.R4.CY6 were performed on pile C1. Test 2.C1.CY3 initially led to
MS 2.R3.CY2 settlements that increased to a maximum after 15 cycles. This is
MS 2.R4.CY2
MS 2.R5.CY2 1 mm/10 cycles because initially the compression load applied to the head of the
MS 3.R6.CY6 pile (,%600 kN) was greater than the tension load (,500 kN). It
had been intended to apply equal compression and tension loads
20 of $600 kN, and so after cycle N ¼ 15 cycling stopped for
40 minutes while the load control was adjusted (Jardine and
Standing, 2012). Once this was rectified, the pile started to pull
a: mm
s
test
out progressively soon after cycling restarted, leading to displace-
ble
Data not logged 20 h of rest, exceeded the accumulated displacement rate failure
m
1
for first 34 cycles criterion in two cycles, and accumulated displacements grew
Stable test to . 0.1D after 12 cycles, when the test was halted. An overall
0 loss in static shaft tensile capacity of 39% accumulated between
1 10 100 1000
Cycles, N the initial and final quick static reference tests (2.C1.T2 compared
with 2.C1.T6). The unstable one-way loading test 2.R4.CY4 also
Figure 14. Permanent accumulated cyclic displacements for stable failed on its first cycle, with accumulated displacements ap-
and metastable loading tests proaching 0.1D after three cycles. Other unstable one-way
loading tests developed excessive permanent accumulated cyclic
displacement rates at comparably early stages, such as 3.R2.CY2
US 3.R2.CY2 US 2.R3.CY3 US 2.C1.CY3 and 2.R3.CY3, where the permanent accumulated displacements
US 2.R4.CY4 US 2.R5.CY3 US 2.C1.CY4 grew towards 0.1D. Quick static tension tests proved shaft
US 2.R6.CY2 US 2.R6.CY4 US 2.C1.CY5
capacity degradations of 48% and 17% for R2 and R3 respec-
50 tively. More gradual failures were observed under one-way
loading in tests 2.R5.CY3 and 2.R6.CY4, where instability was
indicated from the 16th cycle by the rates of permanent cyclic
40
displacement climbing rapidly and increasing towards the dis-
placement limit after 28 and 27 cycles respectively. The reference
30 static tests bracketing the latter tests implied degradations in shaft
capacity . 16%.
a: mm
12
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
1·0 1·0
10%D
2%D
0·8 0·8
"0·10 46·18 "3·97
0·2%D 2·0%D US
2·39 30·66
0·6 0·6
US
Qcyclic /QT
Qcyclic /QT
1·38 6·01
0·02%D 0·18 MS 0·47
MS 0·23 0·42
0·4 0·4 0·33 17·0
0·08 1·11 33·78 0·2%D
0·20 1·71
0·76 0·58
S 0·02%D
0·2 0·02 0·2
0·05
S
0 0
"0·2 0 0·2 0·4 0·6 0·8 1·0 "0·2 0 0·2 0·4 0·6 0·8 1·0
Qmean /QT Qmean /QT
(a) (b)
1·0 1·0
10%D
0·8 0·8
4·51
US US
0·6 0·6
Qcyclic /QT
Qcyclic /QT
2%D 40·1
MS 2%D MS 3·52
0·4 0·80 0·4
34·13 11·74
5·88
0·2%D 1·47
S 3·21 S 4·23
0·2%D
0·2 0·11 0·2 0·20
0·02%D 0·02%D
0 0
"0·2 0 0·2 0·4 0·6 0·8 1·0 "0·2 0 0·2 0·4 0·6 0·8 1·0
Qmean /QT Qmean /QT
(c) 1·0 (d)
1·0
0·8 0·8
US US
0·6 0·6
Qcyclic /QT
Qcyclic /QT
MS 10·95 MS
0·4 0·4
2%D 19·62 2%D
8·61 13·35
S 7·72 S
0·2%D 0·2%D
0·2 0·21 0·2
0·32
0·02%D 0·02%D
0 0
"0·2 0 0·2 0·4 0·6 0·8 1·0 "0·2 0 0·2 0·4 0·6 0·8 1·0
Qmean /QT Qmean /QT
(e) (f)
13
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
0·6
d/D: %
Qcyclic /QT
2
Data not logged
0·4 for the first 34 cycles
0·2
0 1
50
0 100
0 150 , N
0·2 200 cles
0·4
Qm 0·6 250 Cy
ean /Q 0·8 0
T
1·0 300 1 10 100 1000
Cycles, N
(c)
Figure 17. 3D plot for permanent accumulated cyclic Figure 18. Transient cyclic displacements for stable and
displacements equivalent to (a) 0.02%D, (b) 0.2%D and (c) 2%D metastable tests
14
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
10
transient cyclic displacements. Metastable tests showed
US 3.R2.CY2 (0·40) US 2.R6.CY4 (0·44)
9 US 2.R3.CY3 (0·46) US 2.R6.CY2 (0·36) intermediate behaviour.
US 2.R4.CY4 (0·38) US 2.C1.CY3 (0·74) ( f ) The axial cyclic load–displacement responses described in
8 US 2.R5.CY3 (0·35) US 2.C1.CY4 (0·72) this paper have important implications for soil–structure
US 2.C1.CY5 (0·66)
interaction analyses of wind turbines, and add to those made
7
regarding axial cyclic capacity reported by Atkins
6 Consultants Ltd (2000) and Merritt et al. (2012).
d/D: %
5 Acknowledgements
The above research was funded by the EU (through the GOPAL
4
project) and Health and Safety Executive (HSE) of the UK. The
3 authors gratefully acknowledge the Port Autonome de Dunkerque
for providing the test site, and the contributions from Mr Eric
2 Parker of D’Appolonia (Italy). In situ testing was performed by
the Building Research Establishment of Garston, UK, and
1
Simecsol from Dunkerque, France. Laboratory soil testing was
0
performed by former colleagues at Imperial College: Dr Fiona
1 10 100 Chow, Dr Reiko Kuwano and Mr Tim Connolly. The field testing
Cycles, N was conducted in conjunction with Precision Monitoring Control
Ltd of Teesside, UK. The first author has been supported by the
Figure 19. Transient cyclic displacements for unstable tests
Commonwealth Scholarship Commission during the writing of
this paper at Imperial College.
15
Geotechnical Engineering Displacement response to axial cycling of
piles driven in sand
Rimoy, Jardine and Standing
Design Methods for Driven Piles in Sands and Clays. Merritt AS, Schroeder FC, Jardine RJ et al. (2012) Development
Thomas Telford, London, UK. of pile design methodology for an offshore wind farm in the
Jardine RJ, Standing JR and Kovacevic N (2005b) Lessons learned North Sea. Proceedings of the 7th International Conference
from full-scale observations and the practical application of on Offshore Site Investigation and Geotechnics, London, UK,
advanced testing and modelling. Keynote paper. Proceedings pp. 439–447.
of the International Symposium on Deformation Parker EJ, Jardine RJ, Standing JR and Xavier J (1999) Jet
Characteristics of Geomaterials, Lyon. Balkema, Rotterdam, grouting to improve offshore pile capacity. Proceedings of the
the Netherlands, vol. 2, pp. 201–245. Offshore Technology Conference, Houston, TX, USA, OTC
Jardine RJ, Standing JR and Chow FC (2006) Some observations 10828, vol. 1, pp. 415 – 420.
of the effects of time on the capacity of piles driven in sand. Poulos HG (1988) Cyclic stability diagram for axially loaded
Géotechnique 56(4): 227–244. piles. Journal of Geotechnical and Geoenvironmental
Jardine RJ, Puech A and Andersen KH (2012) Cyclic loading of Engineering 114(8): 877–895.
offshore piles: potential effects and practical design. Puech A, Canou J, Bernardini C et al. (2012) Solcyp: a four-year
Proceedings of the 7th International Conference on Offshore JIP on the behaviour of piles under cyclic loading.
Site Investigation and Geotechnics, London, UK. Proceedings of the 7th International Conference on Offshore
Julio RMH (2009) Comportement des pieux et des groupes de pieux Site Investigation and Geotechnics, London, UK, pp. 263–270.
sous chargement latéral cyclique. Thèse de doctorat, Ecole Seidel M (2007) Jacket substructures for the REpower 5M wind
Nationale des Ponts et Chaussées, Paris, France (in French). turbine. Proceedings of the European Offshore Wind
Karlsrud K, Nadim F and Haugen T (1986) Piles in clay under Conference, Berlin, Germany. See http://www.marc-seidel.de/
cyclic axial loading: field tests and computational modelling. papers/seidel_EOW_2007.pdf (accessed 12/12/2012).
Proceedings of the 3rd International Conference on Sommé J (1969) La plaine maritime. Annales, Société Geologique
Numerical Methods in Offshore Piling, Nantes, France, pp. du Nord 89(1): 117–126 (in French).
165–190. Thomas S (1990) Geotechnical Investigation of UK Test Sites for
Kuwano R (1999) The Stiffness and Yielding Anisotropy of Sand. the Foundations of Offshore Structures. Department of
PhD thesis, Imperial College London, London, UK. Energy, HMSO, London, UK, OTH Report 89 294.
Leblanc C, Houlsby GT and Byrne BW (2010) Response of stiff Tsuha CHC, Foray PY, Jardine RJ et al. (2012) Behaviour of
piles in sand to long-term cyclic lateral loading. displacement piles in sand under cyclic axial loading. Soils
Géotechnique 60(2): 79–90. and Foundations 52(3): 393–410.
16