Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

AIRTRADE SYSTEMS PTE LTD

No. 4, TUAS AVE 3, SINGAPORE 639404


TEL: (65) 62621672, FAX: (65) 62621673, EMAIL: peterchan@airtrade.com.sg, Website: www.airtrade.com.sg

CERT NO: 160169


Company's Name : Keppel Fels Ltd TECHNICAL SPECIFICATION Our Ref No : ATS/F/60718/ca-R1
Attention : Mr. Steven Tan Date : 17/7/2013
Project : Hison Turbulence Fans For M-411 From : Peter Chan / Celia Ang

Tag No. Space Served Type Keppel Fels Requirement Airtrade Specification Est
Item No.

Sound Level, SPL @1m


Capacity SPWG Size SPL Fan Fan Motor Power Fan Dia Qty. Motor
Remarks
CFM inch inch @1m Brand Model Speed BkW Rating Supply mm

silencer

silencer
F.L.C.

break-
w/o
c/w

out
dB(A) rpm kW V/Ph/Hz
AMP

TF- IP-55, 50°C amb. Temp. Cl. F ins.


1 Engine Room Circulation 12,000 0.1 36 83 Hison 900-6-a2(4)-12° 1200 0.55 1.1 480/3/60 900 4 67 - 42 2.4
1A/B/C/D 230VAC space heater

IP-55, 50°C amb. Temp. Cl. F ins.


2 TF-2A/B Mud Pump Room Circulation 12,000 0.1 36 83 Hison 900-6-a2(4)-12° 1200 0.55 1.1 480/3/60 900 2 67 - 42 2.4
230VAC space heater

Eexde IIB T4 , Zone 1, IP-56


3 TF-3A/B Drill Floor Circulation 12,000 0.1 36 83 Hison 900-6-a2(4)-12° 1200 0.55 1.1 480/3/60 900 2 67 - 42 2.95 motor; 230 VAC space heater .
SRC type casing

Remarks : Above price quoted is subject to 7% GST.


: Above fan brand: Hison
: Above fan country of origin: Australia/Singapore.
: Above quote does not include spare parts.
: All axial fan blades are of adjustable aluminium types impeller.
: Above axial fans casing quoted shall be mild steel material unless otherwise specified, hot dipped galvanised finished.
: Above axial fans above shall have direct flange except for dia. 450mm & below shall have rolled steel integral flange.
: Above axial fans shall have mininum 125mm x 125mm to a maximum 400mm x 400mm inspection hole to reach motor shaft and blades assembly.
: Sound level data given are based on Q2 directivity at 1m distance in accordance to ISO5136-1990 test method.
: Inspection & test requirement shall include factory acceptance test (FAT) on fans , test on electric motors, vibration, sound
& temperature measurement. Vibration level shall not exceed 3mm/s.
: Fans with ex-proof motor shall be of Spark Resistance Construction (SRC) which consist of anti-spark rings around the path of impeller & motor shaft.
: The performance ratings of Hison fans have been establised by test carried and in accordance with BS 848-Part 1-1980.

1 of 2
AIRTRADE SYSTEMS PTE LTD
No. 4, TUAS AVE 3, SINGAPORE 639404
TEL: (65) 62621672, FAX: (65) 62621673, EMAIL: peterchan@airtrade.com.sg, Website: www.airtrade.com.sg

CERT NO: 160169


Company's Name : Keppel Fels Ltd TECHNICAL SPECIFICATION Our Ref No : ATS/F/60718/ca-R1
Attention : Mr. Steven Tan Date : 17/7/2013
Project : Hison Turbulence Fans For M-411 From : Peter Chan / Celia Ang

Tag No. Space Served Type Keppel Fels Requirement Airtrade Specification Est
Item No.

Sound Level, SPL @1m


Capacity SPWG Size SPL Fan Fan Motor Power Fan Dia Qty. Motor
Remarks
CFM inch inch @1m Brand Model Speed BkW Rating Supply mm

silencer

silencer
F.L.C.

break-
w/o
c/w

out
dB(A) rpm kW V/Ph/Hz
AMP

Motor : All TEFC motor shall be of Manufacturer standard frame, IP55, Class F insulated with 50°C ambient temperature, with 1.15 safety factor
: and 230/1/60 space heater suitable for marine duty.
: Motors of 25kw and above shall complete with motor thermistor / thermometer as per manufacturer's standard.
: Ex-proof motors shall be of Eexde IIB T4 rated
: All 2-speed motors shall be of Dual Winding type.
: IP56 junction box & Ex'e' junction box shall be mounted on fan exterior for standard fans and fans with exproof motor respectively.
: Motors shall be equipped with junction boxes & cable gland (CMP type). Gland size to be confirmed when cable details are furnished.
: Motors certificate shall be provided during final documentation.
: Motors shall be "CMG", make or equal for safe area motors and "AEG" motor or equal for Explosion proof motors.

Deviations : Above fans quoted complies only to relevant rules & regulations where applicable as an equipment of itself and does not include the Rules
: & Regulations & Norm of The Republic of Kazakhstan .
: Compliance to sertification to ROK rules and regulations if applicable, is not included.
: Equipment supply does not include compliance to criteria of system requirements on design and engineering.

Delivery : Approximately 18 to 20 weeks upon receipt of order.


Terms : 30 days from date of our invoice.
Validity : 90 days from date of our quotation.

We trust the above is acceptable and look forward to your esteemed order.

Best Regards,
Peter Chan

2 of 2