Basic Characteristicts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Functional Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Maximum Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Solenoids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Maximum Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DG4S2–012A–*–60
DG4S4–01*A–*–60
DG4S4–01*B–*–60
DG4S4–01*F–*–60
DG4S4–01*C–*–60
DG4S4–01*N–*–60
DG4S2–01*N–*–60
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SDG4S4–01*A–*–60
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
PBDG4S*–01**–*–60
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PA*DG4S*–01**–*–60
PA5DG4S*–01**–*–60
SPA5DG4S*–01**–*–60
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
W, WT & WL Models
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
U Models
Mounting Subplates and Bolt Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2
Basic characteristics General description
Max. pressure Up to 250 bar (3600 psi) DG4S* models are direct solenoid Valves are available with AC or DC
dependent on fluid operated, 2-way or 4-way directional wet-armature solenoid(s). Electrical
control valves. Their primary function in a connections to the valve are made in an
Max. flow rates Up to 95 l/min
hydraulic circuit is to direct fluid flow to a electrical wiring housing or by various
(25 USgpm) dependent
work cylinder or to control the direction plug-in devices. A ground terminal is
on spool
of rotation of a hydraulic motor. provided.
Mounting ISO 4401-05/ Port connections are made by mounting
pattern CETOP 5/NFPA-D05 the valve on a manifold or subplate
containing the interface.
Functional symbols
Graphic
Standard N" Models
Symbol A" Models B" Models C" Models F" Models
Spool Detented
Center Spring Offset Spring Centered Spring Centered Spring Offset
Types (No Spring)
Condition
b AB b AB b AB a b AB b AB a
0
PT PT PT PT PT
b AB b AB a b AB
1
PT PT PT
b AB b AB a
11
PT PT
b AB b AB b AB a b AB b AB a
2
PT PT PT PT PT
b AB b AB a b AB
3
PT PT PT
b AB b AB a
31
PT PT
b AB b AB b AB a b AB b AB a
6
PT PT PT PT PT
b AB a AB b AB a
b AB b AB b
7
PT PT PT PT PT
AB b b AB a
8
PT PT
b AB b AB a b AB a
33
PT PT
b AB b AB a
2
(2-way)
PT PT
1 2 3 4 5 6 7 8 9 10 11
4
Drain NOTE
Surges of oil in a common line serving
On 2-way valves, T" is the drain and
these and other valves can be of
must be connected to the tank through a
sufficient magnitude to cause inadvertent
surge-free line, so there will be no back
shifting of these valves. This is
pressure at this port.
particularly critical in the no-spring
detented type valves. Separate tank
lines, or a vented manifold with a
continuous downward path to tank, are
necessary.
Pressure drops
The pressure drop curves give For any other viscosity, the pressure drop
approximate pressure drop (DP) when (DP) will change as follows:
passing 21 cSt (100 SUS) fluid (having
.865 specific gravity) through the Viscosity cSt 14 32 43 54 65 76 86
indicated flow path. (SUS) (75) (150) (200) (250) (300) (350) (400)
% of DP 93 111 119 126 132 137 141
Pressure drop curve reference chart (Approx)
Curve numbers
Spool type For any other specific gravity (G1),
P-A B-T P-B A-T P-T
the pressure drop (DP1) will be
0C/N 2 1 3 1 2
approximately: DP1 = DP (G1/G)
1C 1 2 3 1 -
11C 2 1 2 2 -
2C/N 2 2 3 2 -
3C 3 2 3 1 - FLOW - USgpm
31C 3 1 3 2 -
0 2 6 10 14 18 22 26
6C/N 4 1 4 1 -
7C/N 1 2 1 2 - 20
280
8C 3 4 3 4 6 7
18 260
33C/N 3 2 3 2 - 6
2 way 240
16 5
2A 2 - 7 -
220
PRESSURE DROP - psid
2A-LH 7 - 2 -
PRESSURE DROP - bar
14 200
2N 2 - 2 - 4
12 180
3 160
Pressure drop curve reference chart 10
Curve numbers 140
Spool type 2
P-A B-T P-B A-T 8 120
0A/F 1 2 2 2 100
0A/F-LH 2 2 2 2 6 1
80
1F 1 2 - -
4 60
1F-LH - - 2 2
2A/F 2 2 5 4 40
2
2A/F-LH 4 4 3 2 20
3F 2 1 - - 0 0
3F-LH - - 2 2
0 20 40 60 80 100
6A/F 2 1 6 3
6A/F-LH 4 2 3 2 FLOW - l/min
7A/F 1 2 2 4
7A/F-LH 2 3 2 2
5
Maximum flow data
Maximum recommended flow data is for
AC & DC solenoid valves
AC or DC solenoids at 90% nominal FLOW - USgpm
voltage in a 4-way circuit with cylinder 0 2 6 10 14 18 22 26
ports either looped or blocked and 300
containing 2,5 liter (.66 USgpm) 4000
compressed volume. Reduced
performance may result when certain 250
spools are used in 3-way circuits.
PRESSURE - psi
PRESSURE - bar
3000
200
6 4 2
Maximum flow chart reference 150
3 2000
Model Spool type Curve number 1
5
AC DC 100
A 0 1 1
2 2 2 1000
6 3 3 50
7 2 2
B/C 0 1 1
0 0
1 6 6
11 6 6 0 20 40 60 80 100
2 1 1 FLOW - l/min
3 2 2
31 2 2
6 2 2
AC & DC solenoid valves
7 1 1 FLOW - USgpm
8 4 8 0 2 6 10 14 18 22 26
33 1 1 300
F 0 1 1
4000
1 5 5
2 1 1 250
PRESSURE - bar
3 1 7
PRESSURE - psi
6 1 7 3000
7 1 1 200
N 0 1 1
2 1 1 150 7 2000
6 1 1
8
7 2 2
33 1 1 100
2-way
A 1000
2 5 5
N 50
2 3 3
0 0
0 20 40 60 80 100
FLOW - l/min
Seals/fluids Application
Special F3 seals are required for use
recommendations
with phosphate ester type fluids or their Filtration...............ISO 4406 Code 18/15
blends. Standard seals are suitable for
use with water glycol, water-in-oil Operating temp......20_ to 50_C (70_ to 120_F)
emulsion fluids, HWBF (95% maximum Fluid viscosity.......16 - 51 cSt (75-250 SUS)
water content), and petroleum oil.
6
Installation dimensions in mm (inches)
3rd angle
Applicable models projection
97,7
(3.85) Sol. `b'
69,5
89,4 (2.73)
36,1
(3.52)
(1.42)
Applicable models
DG4S4-01*C-*-60 Spring centered D
DG4S4-01*N-*-60 No spring detented
DG4S2-01*N-*-60 No spring detented
318,4 DC " models
(12.54) AC" models 241,2
159,2 DC " models (9.50)
(6.27) 120,6 AC" models
(4.75)
97,7
(3.85)
89,4 Sol `b' Sol. `a'
(3.52)
69,3
(2.73)
7
Applicable models
SDG4S4-01*A-*-60 Spring offset
Right hand model shown
Sol. `b'
89,4
(3.52)
69,5
(2.73)
45,3
L" models Manual 190± 0.38
(1.78) 90,5
actuator (.075 ± .015)
(3.56)
46,0
(1.81)
23,0 1,6
(.91) 10,3 (.06)
10,3
(.41) (.41) 16,7
23,8 23,8 (.66)
(.94) (.94)
8
4 leads approx. 178 mm (7.00") long. White leads are connected to solenoid 'a'
and black leads are connected to solenoid 'b'. (See diagram plate) For type 8"
spool and left hand models, conduit connection location is reversed.
Applicable models
PBDG4S*-01 *-*-60 Clearance required to remove
female receptacle
20,2
Stripped and (.80) 63,5
twisted wire (2.50)
12,7
(.50)
WARNING
Warning
plate G
9
Applicable models
PA*DG4S*W/LW-01*A-*-60
PA*DG4S*W/LW-01*B-*-60
PA*DG4S*W/LW-01*F-*-60
PA5DG4S4W/LW-01*C-*-60
PA5DG4S4W/LW-01*N-*-60
SPA5DG4S4W/LW-01*A-*-60
103,5
65,4
14,2 (4.08)
(2.58)
32,7 (.56)
(1.29)
Warning
.8750-16 WARNING
Electrical power tag G
UN-2A Thd. must be disconnected
before removing or
replacing plug
Wiring decal
25,4
Hex 137,4
(1.00)
(5.41)
129,0
(5.08)
104,3
(4.11)
W" models
LW" models [
Electrical connection is over solenoid on [ Receptacle will be prewired directly to the D For models with monitor switch, wires
single solenoid models, and over b" terminals on the solenoid indicator light to be supplied and connected by
solenoid on dual solenoid models. See package. (For exception see note D"). customer.
diagram plate for b" solenoid location.
Electrical rating 600 volts, 3 pole, 10 Receptacle will be prewired to the
amps and 5 pole, 8 amps. The female solenoid eyelets. The connection will be
portable plug to be furnished by made via No. 6 screws and nuts
customer. insulated with black electrical tape. (For
G Warning exception see note D").
Electrical power must be
disconnected before removing
or replacing this receptacle.
10
W, WT & LW models
D For models with monitor switch, The housing can be rotated 180_ if the
wires to be supplied and connected by connection is required on the opposite
customer. end. This connection will readily accept
common electrical quick disconnect
assemblies on the market. The wiring
housing is available with all options.
.5000 NPTF
Dryseal thread
65,4 LW" models D
(2.58)
W/WT" models
32,7
(1.29)
129,0
(5.08)
104,3 137,4
(4.11) (5.41)
DG4S*-W-01 DG4S*-LW-01
A drilled hole is provided for a customer's Lights are on" when there is voltage
no. 8 self tapping screw which will permit across the solenoids.
a ground wire to be secured to the pilot
valve body. (Not shown on this drawing).
The wiring housing has a cast hole 3
which also permits securing a ground
wire with customer's no. 8 self tapping
screw. Units can be series grounded if
desired. The DG4S*-01 pilot valve
bodies have
a cast ground symbol" adjacent to the
drilled hole.
11
U models
120,6 78,5
(4.75) AC" models (3.09)
159,2 89,4
(6.27) (3.52)
DC " models
Plug connector
(Order separately)
(ISO4400/DIN 43650)
51 22,5 D
Cable diameter range Ø6-10mm (0.24-0.40) (2.01) (.88)
Wire section range Ø,5-1,5mm 2 (0.0008-0.0023in2)
Teminals Screw type
27
Type of protection IEC144 class IP65, when plugs are fitted correctly to (1.06)
the valves with the interface seals (suppplied with plugs)
in place.
Seal
M3 1,5
thread (.06)
30,5 5,5
(1.20) (.22)
Connector can be positioned at 90_ Voltage Gray - Black -
Receptacle (AC or DC) 26,5
intervals on valve by re-assembling A" sol. B" sol.
(1.04)
contact holder into appropriate Without
710776 710775
position inside connector housing. lights
27,5
12-24 977467 977466 (1.08)
Connectors with and without indicator With
100-125 977469 977468
lights are available (Order separately): lights
200-240 977471 977470
12
Mounting Subplates and Bolt Kits
13