Full - TMG - SB24 Balance - 07102020
Full - TMG - SB24 Balance - 07102020
Presented to
Prepared by
Auttagorn Choonetra
Vibration Inspector
1. Scope of works
2. Overall Data
3. Conclusion
1. Scope of works
APT Hi - Technique CO., LTD. are required for Field Balance SB24 at Thai Malaya Glass, Saraburi.
In this work, I settle procedure for complete this issue by;
- As – Found Vibration Overall and FFT Data Collect to Confirm Machine’s Root Cause
- As-Built Vibration Overall and FFT Data Collect after Done of Field Balance Procedure
2. Overall Data
*Notes: This is Overhung Blower which connects directly to the Motor’s Shaft without pillow block. In
this case, Motor Vibration and Blower Vibration use with the same measuring point and references.
- Overall Vibration referring with ISO 10816 – 3 Group 2 Rigid Base (mm/s RMS)
- G Enveloped Value referring with Bearing Severity Chart from SKF (gE True P-P)
From data records, Motor has over alarm in Danger Limit referring with ISO 10816-3 Group 2
Rigid Base and Bearing Damage in Unacceptable referring with Bearing Severity Chart from SKF.
In FFT Spectrum, there are obviously signs of Damage in Blower’s Unbalance, Mechanical
Looseness and Blower Missalignment. Refer with Bearing Damage Value, Bearing is out of lifetime and
it’s cause of other damage.
With FFT Spectrum, 1X also high in each direction shown unbalance problem and can reduce
vibration value with field balance procedure. But I am recommended to Overhaul and Bearing
Replacement for Long-term Operation.
Balancing Report
Name: TMG_TM24_07102020
Planes: 1
Count of blades: 10
- Overall Vibration referring with ISO 10816 – 3 Group 2 Rigid Base (mm/s RMS)
Overall Value Comparison Between As-Found and As-Built with Field Balance Procedure
- Overall Vibration referring with ISO 10816 – 3 Group 2 Rigid Base (mm/s RMS)
FFT Spectrum Comparison Between As-Found and As-Built with Field Balance Procedure
- DE Horizontal
- DE Axial
- NDE Vertical
From Data Records, After Field Balance Procedure can saw decrease value obviously in DE
Vertical, NDE Horizontal and NDE Vertical. But it still has high vibration referring with ISO Standard.
See in G-Enveloped which referred bearing damage can saw decrease value obviously in DE
Axial. But it is still high and unacceptable value referring with Bearing Severity Chart from SKF
With FFT Spectrum, Field Balance Procedure successfully cut vibration value cause from
unbalance then reduce vibration value in mentioned point. But the root cause of this machine is not
only unbalance but also Mechanical looseness, Misalignment and Unacceptable Bearing Damage.
Recommendation
Auttagorn Choonetra
AUTTAGORN CHOONETRA
has met the experience, training and examination
requirements for conformity to ISO 18436-2 as