Sun Fire V210 Server


This rack-optimized server sets the standard for all-in-one
solutions with comprehensive, industry-leading features
packed into a 1RU package at PC pricing.

< Superior Performance Combined with Industry-Leading Functionality


Standard with everything a customer could want, the Sun Fire™ V210 is the ultimate
high-density, rack-optimized server. Powered by up to two 1.34-GHz UltraSPARC® IIIi
processors in a compact, 1U form factor, the Sun Fire V210 server is a true all-in-one solution. Four
auto-negotiating Gigabit Ethernet ports provide multiple connectivity for high-speed, highband-
width networking.

Key Feature Highlights


The first server with a low-cost integrated SSL option on the motherboard, the Sun Fire V210
• Rack-optimized, 1RU/25-in.- server provides fast, secure Web transactions without sacrificing CPU cycles or a PCI slot.
depth design
Hotswappable, front-accessible SCSI disks make the Sun Fire V210 reliable and easy to maintain,
• Up to 2 x 1.34-GHz processors service, and upgrade. The standard System Configuration Card and serviceability features enable
• 32 GB memory capacity quick upgrades and repairs, while the unit's Sun Advanced Lights Out Manager (ALOM) provides
• Up to 2 x 73/146-GB, hot-swap, remote management to a large number of servers from virtually anywhere on the network.
UltraSCSI disks
• One full-length PCI slot
(64-bit/66-MHz) Sun Fire V210 Server Specifications
• Single power supply Processor Options Network One 10Base-T Ethernet
• Four integrated Gigabit Ethernet ports Processor One or two 1.34-GHz Management
UltraSPARC IIIi
• SSL encryption daughtercard that Serial Management One TIA/EIA-232-F (RJ45) port
Architecture 64 bit, 4-way superscalar
plugs onto the system mother board SPARC® V9 Serial Port One TIA/EIA-232-F asynchro-
nous (DB9)
• Comes with SolarisTM Operating System, Cache 64 KB data, 32 KB
remote management, Sun Java TM
instructiotion, and 1 MB SCSI One Ultra160SCSI multimode
Enterprise System software, and (SE/LVD)
integrated L2
a variety of I/O connectivity– USB Two OHCI-1.0-compliant
all standard Main Memory interfaces,supporting dual
4 DIMM slots per processor, speedsof 12 and 1.5
registered DDR-1 SDRAM Mbits/sec. each
(PC2100) 128 bit + ECC data Expansion Bus One 64-bit 33/66-MHz, 3.3V,
bus system configurations full-length slot (PCI 2.2-com
from 512 MB to 16GB pliant)

Standard/Integrated Interfaces System Front-accessible for transfer


of Configuration system configuration infor
Network Four 10/100/1000Base-T mation,including host ID
Ethernet readerand card (removable)
Security Optional Hardware
Cryptographic Module,
offering security protocol
acceleration via a
daughtercard
2 Datasheet Sun Fire V210 Server On the Web sun.com/v210

Mass Storage and Media Web and Application Services


Internal Disk Up to two hot-swap • Sun Java System Application
TM

Get the details.


Ultra160SCSI 73/146-GB disks. Server Enterprise Edition 8.
Mixing of drives is permitted 2005Q1 Learn more about the Sun Fire V210 –
in the combinations: • Sun Java System Message
TM

a feature-rich, ready-to-deploy, 1U server


1 x 73-GB Queue 3 2005Q1 Enterprise
1 x 146-GB Edition for Web serving, security applications,
1 x 73-GB & 1 x 146-GB • Sun Java System Web Server
TM

technical computing, and other network


6.1 Service Pack 4 2005Q1
Internal DVD One Slimline ATAPI DVD-ROM services – by visiting: sun.com/V210
(optional)
Portal Services
External Disk Sun StorEdge S1 array*
TM
• Sun JavaTM System Portal
Sun StorEdge 3310 SCSI array* Server 6 2005Q1
Sun StorEdge 3120 SCSI array* • Sun Java System Portal Server
TM
Regulation (meets or exceeds the following
Sun StorEdge 3510 FCAL array Mobile Access 6 2005Q1 requirements)
Sun StorEdge 3511 FCAL array • Sun Java System Portal Server
TM
Safety IEC60950, UL/CSA60950,
Sun StorEdge 3520 FCAL array Secure Remote Access 6 2005Q1 EN60950
Sun StorEdge 5310 FCAL array
Communication and RFI/EMI FCC Class A, Part 15 47 CFR,
Sun StorEdge 9990, 9985, 9980,
Collaboration Services EN55022, CISPR 22
9970, 9960, 9910 series
• Sun Java System Messaging
TM

Immunity EN55024
Sun Storage D240 media tray*
Server 6 2005Q1
* Indicates support for direct attachment Certifications
• Sun Java System Calendar
TM

to server external SCSI port Safety cULus Mark, TUV GS Mark, CE


Server 6 2005Q1
Mark, S-Mark, CCC, GOST
External Tape Sun StorEdge DAT 72 Tape • Sun Java System Instant
TM

Sun StorEdge L8 Tape Autoloader Messaging 7 2005Q1 EMC CE Mark (93/68/EEC), FCC
(Solaris 8 & 9, LT02 & SDLT320) authorized Class A, ICES, VCCI,
Availability Services
Sun StorEdge L25 BSMI, CTICK, MIC, CCC, GOST
• Sun Cluster 3.1 9/04
TM

(Solaris 9 only, LT02)


• Sun Cluster Agents for Sun ONE TM
RoHS Restriction of Hazardous
Sun StorEdge L100 Substances – RoHS compliant
Services (Web, App, Directory,
(Solaris 9 only, LT02) configurations available
Messaging and Calendar
Sun StorEdge L500
Servers and Message Queue) Dimensions and Weight
Software * Sun Cluster is not currently supported
Chassis 43.2mm (1.7 in.) H x 425mm
Operating Solaris 10 beginning with on Solaris 10, but has been loaded for
System release 03/05; Solaris 9 beginning (16.73 in.) W x 635mm (25 in.) D
evaluation on other instances of Solaris
with release 12/03; Solaris 8 Weight 12 kg (26.4 lb.) fully configured;
Operating Environment versions 8 and 9.
beginning with release HW 15.6 kg (34.31 lb.) with rack-
07/03. Requires mandatory patch mount rails and cable
109885-15 Power Supplies
management arm
One
Languages C/C++, FORTRAN, Sun Java TM

Enclosure Fits into a standard 19-in.-wide


programming language; all Maximum DC output 320 W rack. Four-post rack kit
other standard Sun-supported adjustable between 720mm
languages Environment and 925mm
Networking ONC , NFS, TCP/IP, SunLink ,
TM TM

AC power 90 - 264 V AC (47 - 63 Hz)


OSI, MHS, IPX /SPX TM
Key Applications
Operating 5˚ C to 40˚ C (41˚ F to 104˚F), Web Server
Management Sun Management Center
TM

Sun SNMP Agent Temperature 10% to 90% relativehumidity, Security


Sun N1 System Manager noncondensing, 27˚ C max. Application Development
Advanced Lights Out wet bulb Portal Gateway
Management (ALOM) Grid Engine
Sun Net Connect Nonoperating -40˚ C to 65˚ C (-40˚ F to 149˚ F),
Sun Update Connection Temperature up to 93% relative humidity, Technical Computing
noncondensing, 38˚ C max.
Sun Java Enterprise Included with the Sun Fire V210 wet bulb
System server Software is a 90-day
evaluation license for: Altitude Up to 3000m, maximum
Network Identity Services ambient temperature is
• Sun Java System Directory
TM derated by 2˚ C per 500m
Server 5 2005Q1 above 500m
• Sun Java System Access
TM

manager 6 2005Q1 Altitude Up to 12,000m


• Sun Java System Directory
TM (Nonoperating)
Proxy Server 5 2005Q1 Acoustic Noise Less than 7.3B sound power
in ambient temperature of up
to 24˚ C

Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA Phone 1-650-960-1300 or 1-800-555-9SUN Web sun.com
©2006 Sun Microsystems, Inc. All right reserved Sun, Sun Microsystems, the Sun logo, Sun SPARC, Solaris, IPX, Java, ONC, Sun Fire, Sun StorEdge, SunLink, and Sun VTS are trademarks or registered trademarks of Sun
Microsystems, Inc. in the United States and other countries.
02/06 SunWin# 367476