Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

WATER TUBE BOILERS

BAGASSE & MULTYFUEL FOR POWER CO-


GENERATION
1) H.P. Boilers upto 120 TPH at pressure upto 65 Kg / cm2 & Super Heated Temperature upto
500oC  (Also with membrane Wall).
H.P. Steam Boilers on coal, husk, bagasse & bio-gas for co-convention with back pressure
2)
steam for process.
3) Height of Boiler, steam drum, furnace volume, water wall & convention zone bank tubes
ensure efficient circulation & high efficiency. 
4) Design of Furnace volume & arrangement of water wall tubes gives more heating surface in
radiant zone to achieve maximum heat & complete combustion also avoid carry-over
blockage in S.H. Zone. 
5) Variety of fuels & their combustion can be used. (example: Bio-gas & Bagasse also Wood,
Coal, Rice-husk etc., can be effectively burnt individually & in combination) keeping the
steam raising cost very low.
6) Fuel burns in suspension resulting in complete combustion. 
7) Arrangement for quick removal of ash without stopping the boiler provided so that the rate
of the evaporation or working pressure do not stop. 
8) Provision of at temperature controls temperature.
9) Instrument panel & automation ensures safety & efficiency. 
Balance draft achieved through provisions of I.D. & F.D. Fans of requisite capacity along
10)
with secondary air fan.
 

HUT TYPE COMPOSITE BOILER


1) Water wall furnace with shell type fire tube design suitable for multifuel like agrowaste, risk
husk, bagasse, briquette, coal with multi furnace design like stationery, dumping grate,
pulsating grate and fluidized bedded system.
External water wall furnace provided required grate area & volume of fuel, increasing
2)
efficiency.
3) Water cool furnace absorb heat from side wall and radiation losses by brickwork very less.
4) Composite design reduces boiler and installation cost.
Home

Power

ICPL Co-Gen plant generates 28MW power during off-seasonal operation. 11KV generation is
step up to 110KV and connected to nation grid. During off-seasonal operation ICPL exportable
capacity is 26MW & balance for captive utilization. During seasonal operation ICPL Co-Gen
plant generates 23.65MW & exports 16WM surplus power for the nation grid.

 Boiler:
o Make: Thermax Ltd.
o Capacity: 125 TPH
o Working Pr/Temp:  87Kg/CM2 125TPH
o Type: Bi-drum, Natural Circulation, Overfired Trovagrate Boiler.


 Turbine:
o Make: SNM
o Type: Horizontal, Impulse, Multi Stage, Multi Valve, Axial Flow,
Condensing Cum Extraction, Down Exhaust.
o Power:  28MW
o Working Pressure: 85 Kg/CM2
o Working Temperature:  510 Oc
o No. Of Stages: 13

 DM Water Plant:
o 25m3 X 2 Nos. of Reverse Osmosis plant with DM Plant.

 Cooling Water System:


o ULF Microprocessor controlled treatment.