Ent Sal Sal Ent - 1 - 1: Despl Hot, Real Hot, Intervalo Hot, graf-CC Cold, Real Cold, Intervalo

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 24

H1 C1

Tent (ºC)= 100 Tsal (ºC)= 150


Tsal (ºC)= 40 Tent (ºC)= 10
-1 -1
CP (MW K )= 0.2 CP (MW K )= 0.05
Q (MW)= 12 Q (MW)= 7
DTcontr (ºC)= -5 DTcontr (ºC)= 5
Tent,despl (ºC)= 95 Tsal,despl (ºC)= 155
Tsal,despl (ºC)= 35 Tent,despl (ºC)= 15

Tdespl Thot, real CP DHhot,intervalo Hhot,graf-CC Tcold, real CP DHcold,intervalo


(ºC) (ºC) (MW K-1) (MW) (MW) (ºC) (MW K-1) (MW)
155 160 150
95 100 0 0 12 90 0.05 3
35 40 0.2 12 0 30 0.05 3
15 20 0 0 10 0.05 1
Servicio de Calor
Q Tdespl Treal
(MW) (ºC) (ºC)
0 175 180
3 175 180

Tdesplazada (ºC)
Hcold,graf-CC DHintervalo CQNO CQSÍ 180
160
(MW) (MW) (MW) (MW)
140
15 0 3 =Serv. Calor
120
12 3 -3 0 =Pinch 100
9 -9 6 9 80
8 1 5 8 =Serv. Frío 60
40
20
0
0 2 4 6 8 10 12 1
H (MW)
Tdesplazada (ºC)

200
180
160
140
120
100
80
60
40
20
0
0 1 2 3 4 5 6 7 8
Q (MW)
Servicio de Frío
Q Tdespl Treal
(MW) (ºC) (ºC)
0 25 20
8 25 20

6 8 10 12 14 16
H (MW)

4 5 6 7 8 9 10
Q (MW)
H1 C1
Tent (ºC)= 100 Tsal (ºC)= 150
Tsal (ºC)= 40 Tent (ºC)= 10
-1 -1
CP (MW K )= 0.2 CP (MW K )= 0.05
Q (MW)= 12 Q (MW)= 7
DTcontr (ºC)= -10 DTcontr (ºC)= 10
Tent,despl (ºC)= 90 Tsal,despl (ºC)= 160
Tsal,despl (ºC)= 30 Tent,despl (ºC)= 20

Tdespl Thot, real CP DHhot,intervalo Hhot,graf-CC Tcold, real CP DHcold,intervalo


(ºC) (ºC) (MW K-1) (MW) (MW) (ºC) (MW K-1) (MW)
160 170 150
90 100 0 0 12 80 0.05 3.5
30 40 0.2 12 0 20 0.05 3
20 30 0 0 10 0.05 0.5
Servicio de Calor
Q Tdespl Treal
(MW) (ºC) (ºC)
0 175 180
3.5 175 180

Tdesplazada (ºC)
Hcold,graf-CC DHintervalo CQNO CQSÍ 180
160
(MW) (MW) (MW) (MW)
140
15.5 0 3.5 =Serv. Calor
120
12 3.5 -3.5 0 =Pinch 100
9 -9 5.5 9 80
8.5 0.5 5 8.5 =Serv. Frío 60
40
20
0
0 2 4 6 8 10 12 14 1
H (MW)
Tdesplazada (ºC)

200
180
160
140
120
100
80
60
40
20
0
0 1 2 3 4 5 6 7 8
Q (MW)
Servicio de Frío
Q Tdespl Treal
(MW) (ºC) (ºC)
0 25 20
8.5 25 20

6 8 10 12 14 16 18
H (MW)

4 5 6 7 8 9 10
Q (MW)
H1 H2 H3
Tent (ºC)= 160 50 140
Tsal (ºC)= 40 49.9 110
-1
CP (MW K )= 0.03 50 0.05 CP (MW K-1)=
Q (MW)= 3.6 5 1.5
DTcontr (ºC)= -5 -5 -5
Tent,despl (ºC)= 155 45 135
Tsal,despl (ºC)= 35 44.9 105

N.O. Tdespl Thot, real CP CP CP DHhot,intervalo Hhot,graf-CC


(ºC) (ºC) (MW K-1) (MW K-1) (MW K-1) (MW) (MW)
1 165.1 170.1
2 165 170 0 0 0 0
3 155 160 0 0 0 0
4 155 160 0 0 0 0 10.1
5 135 140 0.03 0 0 0.6 9.5
6 105 110 0.03 0 0.05 2.4 7.1
7 65 70 0.03 0 0 1.2 5.9
8 45 50 0.03 0 0 0.6 5.3
9 44.9 49.9 0.03 50 0 5.003 0.297
10 35 40 0.03 0 0 0.297 0
C1 C2
Tsal (ºC)= 160.1 150
Tent (ºC)= 160 60 Calientes Frías
-1
CP (MW K )= 50 0.02 (MW) (MW)
Q (MW)= 5 1.8 C. Proceso = 10.1 6.8
DTcontr (ºC)= 5 5 Servicios = 5 8.3
Tsal,despl (ºC)= 165.1 155 Balance = 15.1 15.1
Tent,despl (ºC)= 165 65

Tcold, real CP CP DHcold,intervalo Hcold,graf-CC DHintervalo CQNO CQSÍ


(ºC) (MW K-1) (MW K-1) (MW) (MW) (MW) (MW) (MW)
160.1 15.1 0 5
160 50 0 5 10.1 5 -5 0
150 0 0 0 10.1 0 -5 0
150 0 0 0 10.1 0 -5 0
130 0 0.02 0.4 9.7 -0.2 -4.8 0.2
100 0 0.02 0.6 9.1 -1.8 -3 2
60 0 0.02 0.8 8.3 -0.4 -2.6 2.4
40 0 0 0 -0.6 -2 3
39.9 0 0 0 -5.003 3.003 8.003
30 0 0 0 -0.297 3.3 8.3
Servicio de Calor Servicio de Frío
Q Tdespl Treal Q Tdespl Treal
(MW) (ºC) (ºC) (MW) (ºC) (ºC)
0 175 180 0 25 20
5 175 180 8.3 25 20
Tdesplazada (ºC)

180
160
140
=Serv. Calor
120
100
=Pinch 80
=Pinch 60
40
20
0
0 2 4 6 8 10 12 14 16
H (MW)
Tdesplazada (ºC)

=Serv. Frío
200
180
160
140
120
100
80
60
40
20
0
0 1 2 3 4 5 6 7 8 9
Q (MW)
H1 H3
Tent (ºC)= 190 Tsal (ºC)=
Tsal (ºC)= 110 Tent (ºC)=
CP (kW K-1)= 2.5 CP (kW K-1)=
Q (kW)= 200 Q (kW)=
DTcontr (ºC)= -10 DTcontr (ºC)=
Tent,despl (ºC)= 180 Tsal,despl (ºC)=
Tsal,despl (ºC)= 100 Tent,despl (ºC)=

N.O. Tdespl Thot, real CP CP DHhot,intervalo Hhot,graf-CC Tcold, real


(ºC) (ºC) (kW K-1) (kW K-1) (kW) (kW) (ºC)
1 180 190 170
2 180 190 0 0 0 200 170
3 100 110 2.5 0 200 0 90
4 100 110 2.5 0 0 90
C1 C2
170
90 Calientes Frías
20 (kW) (kW)
1600 C. Proceso = 200 1600
10 Servicios = 1400 0
180 Balance = 1600 1600
100

Tdesplazada (ºC)
CP CP DHcold,intervalo Hcold,graf-CC DHintervalo CQNO CQSÍ 200
180
(kW K-1) (kW K-1) (kW) (kW) (kW) (kW) (kW)
160
0 1400 =Serv. Calor 140
0 0 0 1600 0 0 1400 120
20 0 1600 0 1400 -1400 0 =Pinch 100
80
20 0 0 0 -1400 0 =Serv. Frío
60
40
20
0
0 2

Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 2
Servicio de Calor Servicio de Frío
Q Tdespl Treal Q Tdespl Treal
(kW) (ºC) (ºC) (kW) (ºC) (ºC)
0 185 190 0 25 20
1400 185 190 0 25 20
Tdesplazada (ºC)

200
180
160
140
120
100
80
60
40
20
0
0 200 400 600 800 10001200 140016001800
H (MW)
Tdesplazada (ºC)

200
180
160
140
120
100
80
60
40
20
0
0 200 400 600 800 1000 1200 1400 1600
Q (MW)
H1 H3
Tent (ºC)= 140 Tsal (ºC)=
Tsal (ºC)= 50 Tent (ºC)=
CP (kW K-1)= 20 CP (kW K-1)=
Q (kW)= 1800 Q (kW)=
DTcontr (ºC)= -10 DTcontr (ºC)=
Tent,despl (ºC)= 130 Tsal,despl (ºC)=
Tsal,despl (ºC)= 40 Tent,despl (ºC)=

N.O. Tdespl Thot, real CP CP DHhot,intervalo Hhot,graf-CC Tcold, real


(ºC) (ºC) (kW K-1) (kW K-1) (kW) (kW) (ºC)
1 130 140 120
2 130 140 0 0 0 1800 120
3 40 50 20 0 1800 0 30
4 40 50 20 0 0 30
C1 C2
120
30 Calientes Frías
5 (kW) (kW)
450 C. Proceso = 1800 450
10 Servicios = 0 1350
130 Balance = 1800 1800
40

Tdesplazada (ºC)
140
CP CP DHcold,intervalo Hcold,graf-CC DHintervalo CQNO CQSÍ
120
(kW K-1) (kW K-1) (kW) (kW) (kW) (kW) (kW)
100
0 0 =Serv. Calor
80
0 0 0 1800 0 0 0 =Pinch
60
5 0 450 1350 -1350 1350 1350
40
5 0 0 0 1350 1350 =Serv. Frío
20
0

Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 2
Servicio de Calor Servicio de Frío
Q Tdespl Treal Q Tdespl Treal
(kW) (ºC) (ºC) (kW) (ºC) (ºC)
0 185 190 0 25 20
0 185 190 1350 25 20
Tdesplazada (ºC)

140
120
100
80
60
40
20
0

H (MW)
Tdesplazada (ºC)

200
180
160
140
120
100
80
60
40
20
0
0 200 400 600 800 1000 1200 1400 1600
Q (MW)
H1 H3
Tent (ºC)= 190 140 Tsal (ºC)=
Tsal (ºC)= 110 50 Tent (ºC)=
CP (kW K-1)= 2.5 20 CP (kW K-1)=
Q (kW)= 200 1800 Q (kW)=
DTcontr (ºC)= -10 -10 DTcontr (ºC)=
Tent,despl (ºC)= 180 130 Tsal,despl (ºC)=
Tsal,despl (ºC)= 100 40 Tent,despl (ºC)=

N.O. Tdespl Thot, real CP CP DHhot,intervalo Hhot,graf-CC Tcold, real


(ºC) (ºC) (kW K-1) (kW K-1) (kW) (kW) (ºC)
1 180 190 170
2 180 190 0 0 0 2000 170
3 130 140 2.5 0 125 1875 120
4 130 140 2.5 0 0 1875 120
5 100 110 2.5 20 675 1200 90
6 100 110 2.5 20 0 1200 90
7 40 50 0 20 1200 0 30
8 40 50 0 20 0 30
C1 C2
170 120
90 30 Calientes Frías
20 5 (kW) (kW)
1600 450 C. Proceso = 2000 2050
10 10 Servicios = 950 900
180 130 Balance = 2950 2950
100 40

Tdesplazada (ºC)
CP CP DHcold,intervalo Hcold,graf-CC DHintervalo CQNO CQSÍ 200
180
(kW K-1) (kW K-1) (kW) (kW) (kW) (kW) (kW)
160
0 950 =Serv. Calor 140
0 0 0 2950 0 0 950 120
20 0 1000 1950 875 -875 75 100
80
20 0 0 1950 0 -875 75
60
20 5 750 1200 75 -950 0 40
20 5 0 1200 0 -950 0 =Pinch 20
0 5 300 900 -900 -50 900 0
0
0 5 0 0 -50 900 =Serv. Frío

Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 1
Servicio de Calor Servicio de Frío
Q Tdespl Treal Q Tdespl Treal
(kW) (ºC) (ºC) (kW) (ºC) (ºC)
0 185 190 0 25 20
950 185 190 900 25 20
Tdesplazada (ºC)

200
A
180
Serv Calor (kW)= 1400
160
140 Serv Frío (kW)= 0
120
100
80
60
40
20
0
0 500 1000 1500 2000 2500 3000 3500
H (MW)
Tdesplazada (ºC)

200
180
160
140
120
100
80
60
40
20
0
0 100 200 300 400 500 600 700 800 900 1000
Q (MW)
B A y B indep. A+B Pagas de másAhorro
0 1400 950 47% 32%
1350 1350 900 50% 33%
GCC Gases del Horno
Q Tdespl Q
(MW) (ºC) (MW)
9 360 9
7.6 310 0
8 230 -0.37380192
4.8 210 -1.20766773
5.8 190
0 190
1 170
7.6 150
3 60
Tdesplazada (ºC)

Qproceso (MW)= 9
400 QCh (MW)= 1.20766773
350
QFuel (MW)= 10.2076677
300
h= 88.17%
250
200
150
100
50
0
-50
-2 0 2 4 6 8 10
Q (MW)
ases del Horno
Tdespl Treal
(ºC) (ºC)
1755 1800 Metano Metano
190 235 T (ºC) =
125 170 Fase =
-20 25 TRef (ºC) =
Fase Ref. =
M Cp xi ni
(g mol-1) (J mol-1 K-1) (mol mol-1) (kmol)
CH4 = 16 CH4 = 1 100
O2 = 32 34.95 O2 = 0 0
N2 = 28 33.03 N2 = 0 0
CO2 = 44 54.15 CO2 = 0 0
H2O = 18 42.75 H2O = 0 0

Suma = 1
Calculos = 100
Masa (kg) = 1600
Entalía (kJ) =

Estamos metiend
procedemos a ca
hemos metido re

Nos piden que calculemos esa


cantidad para que nos den
9000kJ

La temperatura a
cantidad de exce

2)Ahora añadimos la parte de gas de chimenea para hacer el segundo


Metano Aire Aire Aire G.Comb G.Comb G.Comb
25 T (ºC) = 25 T (ºC) = 1800
GAS Fase = GAS XL Fase = GAS
25 TRef (ºC) = 25 (mol mol-1) TRef (ºC) = 25
GAS Fase Ref. = GAS 100% Fase Ref. = GAS
Hi xi ni Hi ni xi ni Hi
(kJ) (mol mol-1) (kmol) (kJ) coef. esteq. (mol mol-1) (kmol) (kJ)
0 0 0 0 -1 0 0
0 0.21 0.06066296 0 -2 -199.939337 -12403487
0 0.79 0.22820826 0 0 0.22820826 13379.451
0 0 0 0 1 100 9611625
0 0 0 0 2 200 15176250
Metemos un poco mas
de lo que nos reacciona
1 100.288871
0.28887122
8.3310459 1608.33105
0 0 12397767.8
entalpia salida
exceso de aire -0.99969669 -99.9696685 %
No se cumple el balance por lo que
hemos supuesto antes no era lo corr
Estamos metiendo una cantidad de exceso de aire, para que nuestra casilla verde nos d
procedemos a calcular que cantidad de exceso de aire Para hacer el cambio le damos a dat
hemos metido referido al estequiometrico. objetivo. En definir celda la que no n
cambiando la cantidad de aire que m

La temperatura adiabatica de llama dependera de la


cantidad de exceso de aire que metamos.

menea para hacer el segundo balance y calcular lo que nos piden


CAMBIAMOS LAS UNIDADES PARA QUE
COINCIDAN EN EL BALANCE DE ENERGIA
(KJ/MOL) (J/MOL)
∆Hreaccion 772.34 772340 Gas chimenea gas chime Gas chimenea
T (ºC) = 235
Base de cálculo = 1 s Fase = GAS
Ch (235 ºC)
TRef (ºC) = 25
9000 kJ Fase Ref. = GAS
Balances G (1800 ºC) xi ni Hi
(mol mol-1) (kmol) (kJ)
0 0
-199.939337 -1467454.76
A (25 ºC) 0.22820826 1582.92096
100 1137150
M (25ºC) 200 1795500

100.288871

0 1608.33105
64836232.2 1466778.16
balance

umple el balance por lo que aplicaremos solver, por que lo que En nuestro balance to
upuesto antes no era lo correcto. Modidicaremos el caudal de aire deberia salirnos 0. Lo
e nuestra casilla verde nos de 0, para que así se cumpla el balance. cambiar ahora es la c
er el cambio le damos a datos y a analisis de hipotesis, buscar metano para hacer ce
. En definir celda la que no nos sale 0; que es lo que queremos sale negativo lo hacem
ndo la cantidad de aire que metemos. , modificando las dos
modificado antes la c
los de aire haciendo 0
componentes de los b
solver con la azul cam
cantidad de metano c
agregamos que el bal
UE
GIA

as chimenea

1segundo
Qproceso(kj)

Los que salen son los de la chimenea

9000 10921989.6
Multiplicamos por 1000 para el cambio de unidades

En nuestro balance total la casilla azul


deberia salirnos 0. Lo que queremos
cambiar ahora es la cantidad que entra de
metano para hacer cero esta casilla. Si
sale negativo lo hacemosocn solver mejor
, modificando las dos casillas que hemos
modificado antes la cantidad de metano y
los de aire haciendo 0 las dos
componentes de los balances. Hacemos
solver con la azul cambiando tanto la
cantidad de metano como la de aire y
agregamos que el balance 1 siga siendo 0