Professional Documents
Culture Documents
Ent Sal Sal Ent - 1 - 1: Despl Hot, Real Hot, Intervalo Hot, graf-CC Cold, Real Cold, Intervalo
Ent Sal Sal Ent - 1 - 1: Despl Hot, Real Hot, Intervalo Hot, graf-CC Cold, Real Cold, Intervalo
Ent Sal Sal Ent - 1 - 1: Despl Hot, Real Hot, Intervalo Hot, graf-CC Cold, Real Cold, Intervalo
Tdesplazada (ºC)
Hcold,graf-CC DHintervalo CQNO CQSÍ 180
160
(MW) (MW) (MW) (MW)
140
15 0 3 =Serv. Calor
120
12 3 -3 0 =Pinch 100
9 -9 6 9 80
8 1 5 8 =Serv. Frío 60
40
20
0
0 2 4 6 8 10 12 1
H (MW)
Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 1 2 3 4 5 6 7 8
Q (MW)
Servicio de Frío
Q Tdespl Treal
(MW) (ºC) (ºC)
0 25 20
8 25 20
6 8 10 12 14 16
H (MW)
4 5 6 7 8 9 10
Q (MW)
H1 C1
Tent (ºC)= 100 Tsal (ºC)= 150
Tsal (ºC)= 40 Tent (ºC)= 10
-1 -1
CP (MW K )= 0.2 CP (MW K )= 0.05
Q (MW)= 12 Q (MW)= 7
DTcontr (ºC)= -10 DTcontr (ºC)= 10
Tent,despl (ºC)= 90 Tsal,despl (ºC)= 160
Tsal,despl (ºC)= 30 Tent,despl (ºC)= 20
Tdesplazada (ºC)
Hcold,graf-CC DHintervalo CQNO CQSÍ 180
160
(MW) (MW) (MW) (MW)
140
15.5 0 3.5 =Serv. Calor
120
12 3.5 -3.5 0 =Pinch 100
9 -9 5.5 9 80
8.5 0.5 5 8.5 =Serv. Frío 60
40
20
0
0 2 4 6 8 10 12 14 1
H (MW)
Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 1 2 3 4 5 6 7 8
Q (MW)
Servicio de Frío
Q Tdespl Treal
(MW) (ºC) (ºC)
0 25 20
8.5 25 20
6 8 10 12 14 16 18
H (MW)
4 5 6 7 8 9 10
Q (MW)
H1 H2 H3
Tent (ºC)= 160 50 140
Tsal (ºC)= 40 49.9 110
-1
CP (MW K )= 0.03 50 0.05 CP (MW K-1)=
Q (MW)= 3.6 5 1.5
DTcontr (ºC)= -5 -5 -5
Tent,despl (ºC)= 155 45 135
Tsal,despl (ºC)= 35 44.9 105
180
160
140
=Serv. Calor
120
100
=Pinch 80
=Pinch 60
40
20
0
0 2 4 6 8 10 12 14 16
H (MW)
Tdesplazada (ºC)
=Serv. Frío
200
180
160
140
120
100
80
60
40
20
0
0 1 2 3 4 5 6 7 8 9
Q (MW)
H1 H3
Tent (ºC)= 190 Tsal (ºC)=
Tsal (ºC)= 110 Tent (ºC)=
CP (kW K-1)= 2.5 CP (kW K-1)=
Q (kW)= 200 Q (kW)=
DTcontr (ºC)= -10 DTcontr (ºC)=
Tent,despl (ºC)= 180 Tsal,despl (ºC)=
Tsal,despl (ºC)= 100 Tent,despl (ºC)=
Tdesplazada (ºC)
CP CP DHcold,intervalo Hcold,graf-CC DHintervalo CQNO CQSÍ 200
180
(kW K-1) (kW K-1) (kW) (kW) (kW) (kW) (kW)
160
0 1400 =Serv. Calor 140
0 0 0 1600 0 0 1400 120
20 0 1600 0 1400 -1400 0 =Pinch 100
80
20 0 0 0 -1400 0 =Serv. Frío
60
40
20
0
0 2
Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 2
Servicio de Calor Servicio de Frío
Q Tdespl Treal Q Tdespl Treal
(kW) (ºC) (ºC) (kW) (ºC) (ºC)
0 185 190 0 25 20
1400 185 190 0 25 20
Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 200 400 600 800 10001200 140016001800
H (MW)
Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 200 400 600 800 1000 1200 1400 1600
Q (MW)
H1 H3
Tent (ºC)= 140 Tsal (ºC)=
Tsal (ºC)= 50 Tent (ºC)=
CP (kW K-1)= 20 CP (kW K-1)=
Q (kW)= 1800 Q (kW)=
DTcontr (ºC)= -10 DTcontr (ºC)=
Tent,despl (ºC)= 130 Tsal,despl (ºC)=
Tsal,despl (ºC)= 40 Tent,despl (ºC)=
Tdesplazada (ºC)
140
CP CP DHcold,intervalo Hcold,graf-CC DHintervalo CQNO CQSÍ
120
(kW K-1) (kW K-1) (kW) (kW) (kW) (kW) (kW)
100
0 0 =Serv. Calor
80
0 0 0 1800 0 0 0 =Pinch
60
5 0 450 1350 -1350 1350 1350
40
5 0 0 0 1350 1350 =Serv. Frío
20
0
Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 2
Servicio de Calor Servicio de Frío
Q Tdespl Treal Q Tdespl Treal
(kW) (ºC) (ºC) (kW) (ºC) (ºC)
0 185 190 0 25 20
0 185 190 1350 25 20
Tdesplazada (ºC)
140
120
100
80
60
40
20
0
H (MW)
Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 200 400 600 800 1000 1200 1400 1600
Q (MW)
H1 H3
Tent (ºC)= 190 140 Tsal (ºC)=
Tsal (ºC)= 110 50 Tent (ºC)=
CP (kW K-1)= 2.5 20 CP (kW K-1)=
Q (kW)= 200 1800 Q (kW)=
DTcontr (ºC)= -10 -10 DTcontr (ºC)=
Tent,despl (ºC)= 180 130 Tsal,despl (ºC)=
Tsal,despl (ºC)= 100 40 Tent,despl (ºC)=
Tdesplazada (ºC)
CP CP DHcold,intervalo Hcold,graf-CC DHintervalo CQNO CQSÍ 200
180
(kW K-1) (kW K-1) (kW) (kW) (kW) (kW) (kW)
160
0 950 =Serv. Calor 140
0 0 0 2950 0 0 950 120
20 0 1000 1950 875 -875 75 100
80
20 0 0 1950 0 -875 75
60
20 5 750 1200 75 -950 0 40
20 5 0 1200 0 -950 0 =Pinch 20
0 5 300 900 -900 -50 900 0
0
0 5 0 0 -50 900 =Serv. Frío
Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 1
Servicio de Calor Servicio de Frío
Q Tdespl Treal Q Tdespl Treal
(kW) (ºC) (ºC) (kW) (ºC) (ºC)
0 185 190 0 25 20
950 185 190 900 25 20
Tdesplazada (ºC)
200
A
180
Serv Calor (kW)= 1400
160
140 Serv Frío (kW)= 0
120
100
80
60
40
20
0
0 500 1000 1500 2000 2500 3000 3500
H (MW)
Tdesplazada (ºC)
200
180
160
140
120
100
80
60
40
20
0
0 100 200 300 400 500 600 700 800 900 1000
Q (MW)
B A y B indep. A+B Pagas de másAhorro
0 1400 950 47% 32%
1350 1350 900 50% 33%
GCC Gases del Horno
Q Tdespl Q
(MW) (ºC) (MW)
9 360 9
7.6 310 0
8 230 -0.37380192
4.8 210 -1.20766773
5.8 190
0 190
1 170
7.6 150
3 60
Tdesplazada (ºC)
Qproceso (MW)= 9
400 QCh (MW)= 1.20766773
350
QFuel (MW)= 10.2076677
300
h= 88.17%
250
200
150
100
50
0
-50
-2 0 2 4 6 8 10
Q (MW)
ases del Horno
Tdespl Treal
(ºC) (ºC)
1755 1800 Metano Metano
190 235 T (ºC) =
125 170 Fase =
-20 25 TRef (ºC) =
Fase Ref. =
M Cp xi ni
(g mol-1) (J mol-1 K-1) (mol mol-1) (kmol)
CH4 = 16 CH4 = 1 100
O2 = 32 34.95 O2 = 0 0
N2 = 28 33.03 N2 = 0 0
CO2 = 44 54.15 CO2 = 0 0
H2O = 18 42.75 H2O = 0 0
Suma = 1
Calculos = 100
Masa (kg) = 1600
Entalía (kJ) =
Estamos metiend
procedemos a ca
hemos metido re
La temperatura a
cantidad de exce
100.288871
0 1608.33105
64836232.2 1466778.16
balance
umple el balance por lo que aplicaremos solver, por que lo que En nuestro balance to
upuesto antes no era lo correcto. Modidicaremos el caudal de aire deberia salirnos 0. Lo
e nuestra casilla verde nos de 0, para que así se cumpla el balance. cambiar ahora es la c
er el cambio le damos a datos y a analisis de hipotesis, buscar metano para hacer ce
. En definir celda la que no nos sale 0; que es lo que queremos sale negativo lo hacem
ndo la cantidad de aire que metemos. , modificando las dos
modificado antes la c
los de aire haciendo 0
componentes de los b
solver con la azul cam
cantidad de metano c
agregamos que el bal
UE
GIA
as chimenea
1segundo
Qproceso(kj)
9000 10921989.6
Multiplicamos por 1000 para el cambio de unidades