Differential Pressure Gauges

To measure differential pressure across all media low


gaseous application.

DBB - Differential Gauge -


with Bourdon Tube Design

Suitable for: - leak detection


- filter protection systems
- closed tank level indicators
- flow measurement
(by measuring drop across orifice plate)

Operating principle
With two separate Bourdon tube elements
High pressure + retained in Bourdon tube
Low pressure - retained in Bourdon tube Common Features

Nominal size 150mm Window


6” Acrylic as standard (safety glass optional)

Case Blow-Out Disc


304 stainless steel Top blow out (compensating optional)

Scale Ranges Mountings


100 kPa to 2500 kPa Pressure entries identified + high pressure - low
or equivalent other units of pressure or vacuum pressure.
Requires mounting by means of rigid tailpipes
Overpressure Safety Direct, surface or panel mountings.
2 x full scale value 250 - 1 000 kPa
1,5 x full scale value - others Wetted Parts
Stainless steel
DCB - Differential Capsule Gauge -
with Capsule Element Design Dail
Aluminium, black lettering on white background
Suitable for: - leak detection
- filter protection Pointer
- low flow Black aluminium adjustable

Operating Principle Process Connections


With retained capsule pressure element ½” BSP male
High pressure + in capsule element ½” NPT male
Low pressure - retained in case
Accuracy
Nominal size 100mm 150mm 100mm & 150mm 1,6% FSD
4” 6”
Temperature Range
O O

Sealing Ambient temperature -25 C to +60 C


O

Nylon Medium temperature to 60 C

Case Weather Protection


Polished 304 stainless steel IP 54

Scale Ring
2,5 kPa to 40 kPa
or equivalent other units of pressure or vacuum

Overpressure Safety
1,5 full scale value to maximum 80 kPa

Parts Number
For the complete part number, consult with your
sales representative when placing an order