Ciclo Di Verniciatura: Painting Cycle

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Doc. No.

TSA018
CICLO DI VERNICIATURA
Painting Cycle Sh 1 of 1

TECHNICAL PROPERTIES See attached technical sheet

Oil and grease to be removed with a suitable detergent.


The entire area to be high pressure fresh water washed in order to remove salts and other
contamination.
PREPARAZIONE SUPERFICIE
When the surface is dry the entire area is to be blast cleaned to min. Sa 2 ½
Surface preparation
(ISO 8501-1:1988)
After abrasive blasting the testing of soluble salts is mandatory and the maximum acceptable
limit shall be 20mg/m2

DESCRIZIONE DEL CICLO / Cycle description

Minimum Nominal Dry film


COAT PAINTING TYPE thickness
MNDFT (µm)

Primer TSA Thermal spray aluminium grade 1350 99.5% aluminium Min. 300 µm

Finish Silicone aluminium Min. 25 µm

TOTAL Minimum Nominal Dry film thickness MNDFT (µm) Min. 325 µm

FINAL COLOUR Aluminium

CONTROLLI RICHIESTI / Inspection Requirements


SURFACE ROUGHNESS CHECK SHALL BE MEASURED BY REPLICA TAPE IN ACCORDANCE WITH ISO 8503-5; SHALL BE MADE AT LEAST
ONCE PER 100 m2 OF PREPARED SURFACE
CONTROLLO DELLA RUGOSITÀ DELLA SUPERFICIE CON METODO REPLICA TAPE IN ACCORDO ALLA ISO 8503-5; DEVE ESSERE FATTO
ALMENO UNA VOLTA PER 100 m2 DELLA SUPERFICIE PREPARATA.
DUST LEVELS SHALL BE CHECKED AT LEAST ONCE PER 100 m2 OF PREPARED SURFACE; THE DUST LEVEL OF THE BLAST CLEANED
SURFACE AT THE TIME OF COATING SHALL NOT EXCEED QUANTITY RATING 1 IN ACCORDANCE WITH ISO 8502-3
IL LIVELLO DELLA POLVERE SARÀ CONTROLLATO ALMENO UNA VOLTA PER 100 m2 DI SUPERFICIE PREPARATA; IL LIVELLO DI POLVERE
AL MOMENTO DI RIVESTIMENTO NON DEVE ESSERE MAGGIORE DEL RATING 1 IN ACCORDO ALLA ISO 8502-3

THE LEVEL OF SALTS CONTAMINATION SHALL BE TESTED AT LEAST ONCE PER 100 m2 OF PREPARED SURFACE; THE MAXIMUM TOTAL
ALLOWABLE SOLUBLE SALTS LEVEL ON THE SURFACE SHALL NOT EXCEED 20 mg/ m 2 AND SHALL BE MEASURED IN ACCORDANCE
WITH ISO 8502-6 AND ISO 8502-9
Il LIVELLO DI CONTAMINZAZIONE DEI SALI DEVE ESSERE TESTATO ALMENO PER 100 m2 DI SUPERFICIE PREPARATA; IL LIVELLO MASSIMO
ACCETTATO NON DEVE SUPERARE I 20 mg/ m2 E DEVE ESSERE MISURATA IN ACCORDO ALLA ISO 8502-6 E ISO 8502-9

REMARK

Painting cycle applicable on gearbox and hand wheel

Q.A.
Q. A.
0 03.05.2017 S.Frazzi Invio per approvazione / Issue for approval
M.Barbetta

Rev: Date: Prepared: Approved: Description: