Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

Part.

Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 1/34


Overseas Support Team
Start - Up Date Mar. 20009

Annunciator

‹ Revision History
Rev. Prepared Checked Approved
Date Revision Contents
No. by by by
Mar. Harold
0 Release YS Kim DH Kim
2009 Lee
Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 2/34


Overseas Support Team
Start - Up Date Mar. 20009

Index

1. Annunciator ___________________________________________________________ 4
1.1. Description of ANN screen _________________________________________________ 4

2. Operation mode by key inputting __________________________________________ 6

3. Annunciator Mode______________________________________________________ 9
3.1. LCD Initialize ___________________________________________________________ 9

3.2. OS ROM Version check ___________________________________________________ 9

3.3. DSP ROM Version check __________________________________________________ 9

3.4. Floor height measurement operation _______________________________________ 10

3.5. Car call registration _____________________________________________________ 11

3.6. Error TRACE Data read _________________________________________________ 11

3.7. Reset TRACE Data read _________________________________________________ 12

3.8. Statistic Data read_______________________________________________________ 12

3.9. Statistic Data Clear ______________________________________________________ 13

3.10. Non power failure Reset Count read________________________________________ 13

3.11. Emergency stop Trace Data read __________________________________________ 14

3.12. SPEC ROM Read/Write__________________________________________________ 14

3.13. TCD DISPLAY _________________________________________________________ 16

3.14. Error log table __________________________________________________________ 16

3.15. Error log table clear _____________________________________________________ 18

3.16. DSP Memory read_______________________________________________________ 18

3.17. DSP SPEC WRITE ______________________________________________________ 19

3.18. Manual LRT operation. __________________________________________________ 19

3.19. No load point setting _____________________________________________________ 20

3.20. Full load point setting ____________________________________________________ 21

3.21. Time setting mode _______________________________________________________ 22


Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 3/34


Overseas Support Team
Start - Up Date Mar. 20009

3.22. Door condition check ____________________________________________________ 23

3.23. Hall Check mode________________________________________________________ 24

3.24. Car Check mode ________________________________________________________ 25

3.25. POSI(PRS) TEST mode __________________________________________________ 25

3.26. Car load mode __________________________________________________________ 26

3.27. 110% Function test mode _________________________________________________ 27

3.28. 110% Cut Mode ________________________________________________________ 27

3.29. SDS Check Mode _______________________________________________________ 28

3.30. CRT Data Reset Mode ___________________________________________________ 29

4. Trace Data reference Method ____________________________________________ 30


4.1. Mode for Error Log Table reference ________________________________________ 30

4.2. Key function ___________________________________________________________ 30

4.3. Additional Information Flag Table _________________________________________ 32


Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 4/34


Overseas Support Team
Start - Up Date Mar. 20009

1. Annunciator
Function that only reading data is possible at DOC PCB. But for the writing and reading can
be done at DES PCB.
1.1. Description of ANN screen
a. Initial screen of annunciator
Initial screen: When the main power turn on, LCD display will show as below.
C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16
R1 A C D = 0 4 0 8 F L 0 0 %
R2 E 0 0 0 - 0 0 1 0 0 0 0 0 S
R3 1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
R4 K :

b. Row 1: Operation mode, present floor, load weight and speed of elevator.
a) ACD=27(Column1~ 6): Operation Code( ex: 27*Auto operation, 4*Maintenance
Operation, ...) ※ Refer to the MODE Description
b) 01FL (Column 8 ~11): Present floor
c) 00% (Column 13 ~ 16): On stop, present load weight (%) of the elevator.
c. Row 2: When an error occurs, it shows the trouble code of the top-level error, condition of
the operation, output of main signal and direction of elevator.
a) E000 (Column 2 ~ 4): Trouble code of high level error. (TCD No. 1 ~ 255)
031 DC Link Over-voltage 116 POSI(PRS) ON error(LDU)
052 INV reverse running detection 172 SD1U input error
084 R5SY relay ON error 200 CNET LON Comm. Error

b) 00(Column 6 ~ 7): Operation condition of the high level error


01 R5SC Cut 10 Fast Run Cut
02 R5SC Cut possible 20 Safety Drive operation Possible
04 C1ST Cut 40 Rest operation Possible
08 C1ST Cut possible 80 Hall Call Cut Possible

c) 100100 (Column 9 ~ 14): Displays output of main signals.


(a) "1": Means that switch, relay and contactor, etc. is operated.
(b) "0": Means that switch, relay and contactor, etc. is not operated.
(c) Each column means as follows;

C9 R5SY C10 C1ST C11 C1BR C12 C1BS


C13 Door Open Command C14 Door Close Command
Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 5/34


Overseas Support Team
Start - Up Date Mar. 20009

d) S (C16): Displays the present direction of elevator.


- "S": STOP "U": UP "D": DOWN

d. Row 3: Displays input condition of main signal such as switches, relays and contactor, etc.

C1 R5SY C5 LDC(PRS) C9 C1ST C13 CDS


C2 24Vdc C6 LDCX C10 C1BR C14 DCLS
C3 UL C7 SDS1D C11 Suppress C15 DOLS
C4 DL C8 SDS1U C12 LDS C16 SES

a) "1": Means that switch, relay and contactors, etc. is operated.


b) "0": Means that switch, relay and contactors, etc. is not operated.

e. ACD MODE

Mode Description Mode Description Mode Description

00 Stop 01 ALP operation 02 Earthquake control door open

03 Failure 04 Maintenance operation 05 Earthquake control finished


Earthquake control slow Bottom floor slow operation
06 Earth quake control 07 operation 08 (SPEC. ROM F/H error)
F height measurement Bottom floor slow operation
09 F/H measurement ready 0A operation 0B (C RAM F/H error)
0C Unused 0D Unused 0E 2nd fire operation
All floors operation after
0F 1st fire operation 10 Arrival operation finished 11 earthquake control
12 Eme. Return Operation 13 Fireman operation 14 Fireman return operation
Rescue arrival operation
15 Rescue arrival Operation 16 Rescue operation 17 finished
18 Rescue return operation 19 Fire operation finished 1A Fire operation
T/M temp detection operation
1B finished 1C TM temp detection operation 1D Unused
Eme Generator driven EME. Generator driven E&I PANEL temp. detection
1E operation finished 1F operation 20 operation finished
E&I PANEL temp. detection
21 operation 22 Rest 23 Standby operation finished

24 ATT operation 25 Semi- auto operation 26 Back-up operation


Air-conditioner water drain LRT operation
27 Auto operation 28 operation 29 (Locked Rotor Test)
※ LRT operation: Whenever system starts newly, this operation will be done automatically.
Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 6/34


Overseas Support Team
Start - Up Date Mar. 20009

2. Operation mode by key inputting

MAIN MODE SUB MODE Resetting


Classification
MAIN MODE KEY Input SUB MODE KEY Input KEY Input
Floor height
A12E(DES) START 3 FFFF
measurement Op.
Input lowest floor call A13E(DES)
Input middle floor call A14E(DES)
Input highest floor call A15E(DES)
Operation
related mode Input lowest floor call A16E(DES)
(Hold)
Input middle floor call
A17E(DES) FFFF
(Hold)
Input highest floor call
A18E(DES)
(Hold)
Input random floor call A19E(DES) xxE -> Floor
A21E(DO+DE) Address INC 0
A22E(DO+DE) Address DEC 8
Address Input xxxxE
Data Read & Write FFFF
Address Re-input BBB
PROTECTION
AAE
release
Data Input xxE
A23E(DO+DE) Item INC 0
TRACE DATA READ
(TRACE when error Item DEC 8
FFFF
occurs Block INC 1
5000h ~ )
Block DEC 9

Memory A24E(DO+DE) Item INC 0


related mode TRACE DATA READ Item DEC 8
(TRACE when reset
FFFF
occurs Block INC 1
4400h ~ )
Block DEC 9
A25E(DO+DE) Item INC 0
Statistics Data read &
Item DEC 8 FFFF
Deletion
Data Deletion CCCC
Statistics Data deletion A26E(DO+DE) Deletion check E FFFF
Reset count without
A27E(DO+DE) FFFF
power failure
A28E(DO+DE) Item INC 0
Emergency stop
TRACE Item DEC 8 FFFF
Data read
Deletion all CCCC
Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 7/34


Overseas Support Team
Start - Up Date Mar. 20009

A31E(DES) Address INC 0


Address DEC 8
Address Input xxxxE
Spec SPEC DATA READ &
FFFF
related mode WRITE A32E(DES) Address Re-input BBB
PROTECTION
AAE
release
Data Input xxE
TABLE INC 0
TCD DISPLAY A41E(DO+DE) FFFF
TABLE DEC 8
TABLE INC 0
TABLE DEC 8
Error First error 1
ERROR LOG DISPLAY A42E(DO+DE)
related mode Last error 9
FFFF
Display mode change C
(Time->Trace)
ERROR LOG CLEAR A43E(DO+DE)
TCD CLEAR A44E(DO+DE)
Address INC 0
Address DEC 8
DSP READ A51E(DES) FFFF
DSP mode Address Input xxxxE
Address Re-input BBB
DSP SPEC WRITE A52E(DES)
NO LOAD POINT SET A61E(DES) xxE FFFF
FULL LOAD POINT
A62E(DES) Load Input xxxE FFFF
SET
Parameter Zero Load point
A64E(DES)
related mode adjustment
HALF LOAD POINT
A65E(DES) Load Input N/A FFFF
SET
Date/Time mode
C
RTC SET A69E(DO+DE) change FFFF
Data Input xxE
OS ROM version check A01E(DO+DE) FFFF
DSP ROM version
A02E(DO+DE) FFFF
check
State check PCB Protection check A03E(DO+DE) FFFF
mode OS ROM version
DEEE
Check in DES PCB
Door condition check A71E(DO+DE) FFFF
Car Load display A86E(DO+DE) FFFF

Device Test Hall Check Mode A82E(DO+DE) FFFF


Mode Car Check Mode A83E(DO+DE) FFFF
Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 8/34


Overseas Support Team
Start - Up Date Mar. 20009

Device Test PRS measurement UP operation UP Switch


mode mode A85E(DES) FFFF
DN operation DN Switch
PTM check A86E(DES) Current PTM input FFFF
110% Function test
A87E(DES) Testing Load Input (%) xxE FFFF
mode
SDS Test (UP) 3
SDS Test mode A89E(DES) FFFF
SDS Test (DN) 7
Other mode LCD INITIALIZE DOC+DES Input ‘0’ over 4 times FFFF
LRT operation A54E Start 3 FFFF
110% Cut mode A88E(DES)
CRT Data reset A90E(DOC+DES)
Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 9/34


Overseas Support Team
Start - Up Date Mar. 20009

3. Annunciator Mode

3.1. LCD Initialize


a. Preparation
a) Checking of software version for annunciator
b) Set the S/W 3 to the DOA ‘ON’ position after connecting between DOA-100 and DOC-120.
b. Screen check
Press the '0' over 4 times and then LCD will be displayed within 3 sec.

3.2. OS ROM Version check


a. Screen check
a) Check the Ver. No and Date at Row 4 after input A01E.
C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16
R1 A C D = 2 7 [ 8 5 ] 5 0 %
R2 E 0 0 0 - 0 0 1 0 0 0 0 0 S
R3 1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
R4 V 0 1 . 0 0 9 9 / 0 7 / 1 5

b) Ex) Version 1.0, creation date is July 15th 1999.


c) Auto-reset about 2.5 sec later

3.3. DSP ROM Version check


a. Screen check
a) Check the Ver. No and Date at Row 4 after input A02E.
A C D = 2 7 [ 5 ] 5 0 %
E 0 0 0 - 0 0 1 0 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
V O 3 . 0 0 9 9 . 0 7
b) Ex) Version 3.00, creation date is July.1999.
c) Auto-reset about 2.5 sec later.
Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 10/34


Overseas Support Team
Start - Up Date Mar. 20009

3.4. Floor height measurement operation


a. Preparation
Check if the E.STOP switch on E&I panel is ‘Off’ position.
b. Screen check
a) Verify that ACD = 09 after inputting "A12E" and press '3'. (This is maintained until
bottom Floor DL S/W is inputted.)
A C D = 0 9 0 0 F L 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
W E n a b l e K :
b) When ‘W Enable’ is displayed, Check if the S/W2 on DOC PCB to ‘Write’. Then FHM
MD is displayed on LCD.
c) When the car has reached the bottom floor and stopped by DL switch, press button #3,
the floor height measuring command.
d) The LCD screen state is as follows;
A C D = 0 A [ 0 F ] 1 5 M
E 0 0 0 - 0 0 1 0 0 0 0 U
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
F H M S T K :
e) When floor height measuring operation has started, FHM ST displays in row 4.
f) The car will travel until UL switch operates.
g) When floor height measuring has completed, LCD screen state is;
A C D = 0 A [ 1 6 ] 5 0 %
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
F H M P A S S K :
h) If FHM is successful, FHM PASS will display.

b. Observances
a) Enter 'FFFF' to clear the floor height measuring operation mode.
b) LCD Screen State is as follows;
A C D = 2 7 [ 1 6 ] 5 0 %
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
K :
c) ACD=27 will display in automatic mode.
d) If FHM has failed, the screen will be;
Part. Annunciator
MUSE ED Elevator Ctrl. No. MUSE ED-SR-02-0

FOD Page 11/34


Overseas Support Team
Start - Up Date Mar. 20009

A C D = 0 9 [ ] 0 0 M
E 0 0 0 - 0 0 1 0 0 0 0 S
1 1 0 0 1 1 0 0 0 0 1 1 1 0 1
F H M F A I L K :
e) FHM Fail, which means floor height measuring has failure, will display.
f) The car will return to the bottom floor automatically.

3.5. Car call registration


a. Screen check
After inputting ‘A19E’, check if ‘CALL’ is displayed at 4th row.
b. Call
To make a service for 12th floor, key in ‘12E’ with decimal value.

3.6. Error TRACE Data read


a. Screen check
a) "TRC X-Y" will be displayed after input A23E
X : Traced Total Block No. Y : Present Block No.
Screen of A23E

A C D = 0 3 [ F ] 5 0 %
E 0 0 0 - 0 0 1 0 0 0 0 S
Item No. 0 0 : 5 0 0 0 = 0 8 2 4 1 6 2 2
T R C 5 3 0- 1 K :
Address

Total Block No. Traced Block No.

b) To read the higher Item No., input '0'. For the lower, input '8'
ex) If you input '0' two times on A23E initial screen, indicates as below. (Address will be
increase 4 per one)
c) LCD Screen
A C D = 0 3 [ F ] 5 0 %
E 0 0 0 - 0 0 1 0 0 0 0 S
0 2 : 5 0 0 8 = 0 0 0 0 0 0 9 1
T R C 3 - 1 K :
d) The displayed data and address are Hexadecimal value.
e) To read the higher block No., input '0'. For the lower, input '8'
ex) If you input '1' one time on A23E initial screen, indicates as below. (Address will be