Download as pdf or txt
Download as pdf or txt
You are on page 1of 39

Cat Electronic Technician 2019B v1.

0
Product Status Report

1/30/2020 3:07 PM

Product Status Report


Parameter Value
Engine Serial Number ZAR00796
Equipment ID NOT PROGRAMMED
Comments

3516B Engine - Genset #1 (ZAR00796)


Parameter Value
Equipment ID NOT PROGRAMMED
Engine Serial Number ZAR00796
ECM Serial Number 3361B203JP
Personality Module Part Number 3489844-00
Personality Module Release Date MAY09
Personality Module Description GENSET

Logged Diagnostic Codes [Diagnostic Clock = 599 hours] - 3516B Engine - Genset #1
(ZAR00796)
Code Description Occ. First Last
91- 8 Throttle Position Sensor : Abnormal Frequency, 1 599 599
Pulse Width, or Period

Logged Event Codes [Diagnostic Clock = 599 hours] - 3516B Engine - Genset #1 (ZAR00796)
Code Description Occ. First Last
No Logged
Event Codes

Active Diagnostic Codes - 3516B Engine - Genset #1 (ZAR00796)


Code Description
No Active
Diagnostic
Codes

Active Event Codes - 3516B Engine - Genset #1 (ZAR00796)


Code Description
No Active
Event Codes

Current Totals - 3516B Engine - Genset #1 (ZAR00796)


Description Value Unit
Total Time 599 hours
Total Fuel 16734 gal

Configuration - 3516B Engine - Genset #1 (ZAR00796)


Description Value Unit
Equipment ID NOT PROGRAMMED
Engine Serial Number ZAR00796
ECM Serial Number 3361B203JP
Personality Module Part Number 3489844-00
Personality Module Release Date MAY09
Rated Engine Speed 1500 rpm
Fuel Ratio Control Offset 0
Acceleration Delay Time 0 sec
Engine Acceleration Rate 250 rpm/s
Low Idle Speed 900 rpm
Cooldown Speed 900 rpm
Cooldown Duration 0 min
Engine Pre-Lube Duration 0 sec
Engine Pre-Lube System Configuration Automatic
Engine Continuous Pre-Lube Interval 0 min
Crank Duration 0 sec
Maximum Number of Crank Cycles 0
Crank Terminate RPM 400 rpm
Engine Speed Droop 0.0 %
Rated Fuel Position 29.500 mm
Fuel Correction Factor 0 %
Governor Gain Factor #1 26214
Governor Minimum Stability Factor #1 629
Governor Maximum Stability Factor #1 7864
FLS 0
FTS 0
Air Shutoff Disabled
Air Intake Shutoff Detection Installation Unavailable
Status
Ether Control Disabled
Engine Cooling System Config SCAC (Separate Circuit Aftercooled)
Cold Cylinder Cutout Disabled
Direct Fuel Control Mode Disabled
Desired Speed Input Configuration CAN Input
Throttle Air Pressure Sensor Installation Unavailable
Status
Throttle Input Low Idle Duty Cycle Setpoint Unavailable %
Throttle Input High Idle Duty Cycle Setpoint Unavailable %
Secondary Desired Speed Input Not Installed
Configuration
Fuel Enable Input Configuration CAN Input
Secondary Fuel Enable Input Enable Enabled
Status
Coolant Level Sensor Not Installed
Aftercooler Coolant Level Sensor Not Installed
Installation Status
Cat Data Link #2 Identifier Engine Control #1
Inlet Air Temperature Sensor Not Installed
Engine Oil Temperature Sensor Installation Installed
Status
Total Tattletale 3

Monitoring System - 3516B Engine - Genset #1 (ZAR00796)


Description State Trip Point Delay Time
Altitude (atmospheric
pressure)
Moderate Severity (2) On 11.0 psi 0 sec
Engine Overspeed
Least Severe (1) On 1770 rpm 0 sec
Most Severe (3) On 1770 rpm 0 sec
High Aftercooler
Coolant Temperature
Least Severe (1) On 216 Deg F 5 sec
Moderate Severity (2) On 225 Deg F 5 sec
Most Severe (3) On 225 Deg F 5 sec
High Air Filter
Restriction Pressure
Least Severe (1) On 28.1 " H2O 5 sec
Moderate Severity (2) On 28.1 " H2O 5 sec
High Boost Pressure
Least Severe (1) Off 58.0 psi 0 sec
Moderate Severity (2) Off 58.0 psi 0 sec
High Crankcase
Pressure
Least Severe (1) On 8.0 " H2O 3 sec
Moderate Severity (2) On 24.1 " H2O 10 sec
Most Severe (3) On 14.1 " H2O 3 sec
High Engine Coolant
Temperature
Least Severe (1) On 216 Deg F 5 sec
Moderate Severity (2) On 225 Deg F 30 sec
Most Severe (3) On 225 Deg F 5 sec
High Engine Oil Filter
Restriction Pressure
Least Severe (1) On 15 psi 5 sec
High Exhaust
Temperature
Least Severe (1) On 1342 Deg F 5 sec
Moderate Severity (2) On 1342 Deg F 5 sec
High Fuel Filter
Restriction Pressure
Least Severe (1) On 15 psi 5 sec
Low Aftercooler
Coolant Level
Least Severe (1) On None 30 sec
Most Severe (3) Off None 30 sec
Low Coolant Level
Least Severe (1) On None 30 sec
Most Severe (3) Off None 30 sec
Low Engine Coolant
Temperature
Least Severe (1) On 176 Deg F 5 sec
Low Engine Oil
Pressure
Least Severe (1) On None 4 sec
Most Severe (3) On None 9 sec
Low Fuel Pressure
Most Severe (3) On 32 psi 20 sec
Low System Voltage
Least Severe (1) On 20 Volts 10 sec

Injector Codes Calibration - 3516B Engine - Genset #1 (ZAR00796)


Injector Code
Injector 1 2450
Injector 2 9825
Injector 3 1225
Injector 4 6410
Injector 5 3865
Injector 6 1576
Injector 7 5866
Injector 8 4740
Injector 9 7840
Injector 10 7827
Injector 11 6727
Injector 12 9602
Injector 13 6520
Injector 14 1990
Injector 15 7957
Injector 16 5200

EMCP 3.1
Parameter Value
ECM Part Number 3007645-03
ECM Serial Number 3121B055UA
Software Group Part Number 3927385-00
Software Group Release Date MAR2011
Software Group Description L0 9_0 Standard -- English, 2.2.3 Prod,
14December2011

Logged Diagnostic Codes [SHM: 599] - EMCP 3.1


Code Description Occ. SHM First SHM Last RTC First RTC Last
No Logged
Diagnostic
Codes
Logged Event Codes [SHM: 599] - EMCP 3.1
Code Description Occ. SHM First SHM Last RTC First RTC Last
110-17 Engine Coolant 31 0:28:30 598:19:30
Temperature : Low - least
severe (1)
167-17 Charging System 1 0:00:00 0:00:00
Potential : Low - least
severe (1)
168-17 Battery Potential / Power 21 0:00:00 162:13:30
Input #1 : Low - least
severe (1)
190- 1 Engine Speed : Low - 2 1:50:01 1:50:38
most severe (3)
190-17 Engine Speed : Low - 2 1:50:01 1:50:38
least severe (1)
970-31 Engine Auxiliary Engine 30 0:00:00 162:13:30
Shutdown Switch
1664-31 Engine Automatic Start 1 0:00:00 0:00:00
Failed
4007-31 Generator Control not in 27 0:00:00 1:40:30
Automatic

Active Diagnostic Codes [SHM: 599] - EMCP 3.1


Code Description Occ.
No Active
Diagnostic
Codes

Active Event Codes [SHM: 599] - EMCP 3.1


Code Description Occ.
No Active
Event Codes

Current Totals - EMCP 3.1


Description Value Unit
Total Operating Hours 598.5 hours

Configuration - EMCP 3.1


Description Value Unit
Engine Start Fault Protection Activation 30 sec
Delay Time
Crank Duration 10 sec
Crank Cycle Rest Interval 10 sec
Engine Purge Cycle Time 0 sec
Maximum Number of Crank Cycles 5
Cooldown Duration 5 min
Start Aid Activation Time 0 sec
Crank Alert Activation Time 0 sec
Crank Terminate RPM 400 rpm
Engine Fuel Type Configuration Diesel
Fuel Shutoff Solenoid Type Configuration Energized to Run
Engine Type Configuration Electronic
Engine Controller J1939 Data Link Support Proprietary J1939 Support
Configuration
Engine Cooldown Speed Configuration Rated Speed
Engine Operating State Input Configuration Hardwired Input
Fuel Priming Feature Enable Status Disabled
Engine Forced Idle Feature Enable Status Disabled
Maximum Generator Voltage Output Bias 5 %
Percentage
Generator Nominal Output Voltage 6000 Volts
High Battery Voltage Warning Event 30.0 Volts
Threshold
High Battery Voltage Warning Event 30 sec
Notification Delay Time
High Battery Voltage Shutdown Event 32.0 Volts
Threshold
High Battery Voltage Shutdown Event 2 sec
Notification Delay Time
Low Battery Voltage Warning Event 18.0 Volts
Threshold
Low Battery Voltage Warning Event 10 sec
Notification Delay Time
Low Battery Charging System Voltage 22.0 Volts
Warning Event Threshold
Low Battery Charging System Voltage 30 sec
Warning Event Notification Delay Time
Low Cranking Voltage Warning Event 0.0 Volts
Threshold
Low Cranking Voltage Warning Event 2 sec
Notification Delay Time
Digital Input #1 Active State Configuration High
Digital Input #2 Active State Configuration Low
Digital Input #3 Active State Configuration Low
Digital Input #4 Active State Configuration Low
Digital Input #5 Active State Configuration Low
Digital Input #6 Active State Configuration Low
Digital Selector #1 Source Configuration Input #2
Digital Selector #2 Source Configuration Disabled
Digital Selector #3 Source Configuration Disabled
Digital Selector #4 Source Configuration Input #6
Digital Selector #5 Source Configuration Disabled or Not Installed
Digital Selector #6 Source Configuration Disabled or Not Installed
Digital Selector #7 Source Configuration Disabled or Not Installed
Digital Selector #8 Source Configuration Disabled or Not Installed
Digital Selector #9 Source Configuration Disabled or Not Installed
Digital Selector #10 Source Configuration Disabled or Not Installed
Engine Coolant Temperature Sensor Data Link
Configuration
High Engine Coolant Temperature Warning 216 Deg F
Event Threshold
High Engine Coolant Temperature Warning 2 sec
Event Notification Delay Time
High Engine Coolant Temperature 225 Deg F
Shutdown Event Threshold
High Engine Coolant Temperature 10 sec
Shutdown Event Notification Delay Time
Low Engine Coolant Temperature Warning 70 Deg F
Event Threshold
Low Engine Coolant Temperature Warning 2 sec
Event Notification Delay Time
Engine Coolant Temperature Sensor Map #1
Configuration Code
Engine Oil Pressure Sensor Configuration Data Link
Low Engine Oil Pressure Warning Event 35 psi
Threshold
Low Idle Low Engine Oil Pressure Warning 15 psi
Event Threshold
Low Engine Oil Pressure Warning Event 0 sec
Notification Delay Time
Low Engine Oil Pressure Shutdown Event 30 psi
Threshold
Low Idle Low Engine Oil Pressure 10 psi
Shutdown Event Threshold
Low Engine Oil Pressure Shutdown Event 0 sec
Notification Delay Time
Low Engine Oil Pressure Step Speed 1200 rpm
Engine Oil Pressure Sensor Configuration Map #1
Code
Flywheel Teeth 183
Engine Overspeed Setpoint 1770 rpm
Engine Underspeed Warning Event 1290 rpm
Threshold
Engine Underspeed Warning Event 10.0 sec
Notification Delay Time
Engine Underspeed Shutdown Event 1230 rpm
Threshold
Engine Underspeed Shutdown Event 10.0 sec
Notification Delay Time
Engine Speed Sensor Configuration Sensor
Event Input Function #1 Suspect Custom Event
Parameter Number
Event Input Function #1 Failure Mode Condition Exists
Identifier
Event Input Function #1 Event Notification 10 sec
Delay Time
Event Input Function #1 Active State High
Configuration
Event Input Function #2 Suspect Custom Event
Parameter Number
Event Input Function #2 Failure Mode Condition Exists
Identifier
Event Input Function #2 Event Notification 0 sec
Delay Time
Event Input Function #2 Active State High
Configuration
Event Input Function #3 Suspect Custom Event
Parameter Number
Event Input Function #3 Failure Mode Condition Exists
Identifier
Event Input Function #3 Event Notification 0 sec
Delay Time
Event Input Function #3 Active State High
Configuration
Event Input Function #4 Suspect Battery Charger Failure
Parameter Number
Event Input Function #4 Failure Mode Condition Exists
Identifier
Event Input Function #4 Event Notification 0 sec
Delay Time
Event Input Function #4 Active State High
Configuration
Event Input Function #5 Suspect Disabled or Not Installed
Parameter Number
Event Input Function #5 Failure Mode Disabled or Not Installed
Identifier
Event Input Function #5 Event Notification Disabled or Not Installed sec
Delay Time
Event Input Function #5 Active State Disabled or Not Installed
Configuration
Event Input Function #6 Suspect Disabled or Not Installed
Parameter Number
Event Input Function #6 Failure Mode Disabled or Not Installed
Identifier
Event Input Function #6 Event Notification Disabled or Not Installed sec
Delay Time
Event Input Function #6 Active State Disabled or Not Installed
Configuration
Event Output Function #1 Suspect Engine Oil Pressure
Parameter Number
Event Output Function #1 Trigger Condition **Disabled
Event Output Function #2 Suspect Disabled or Not Installed
Parameter Number
Event Output Function #2 Trigger Condition Disabled or Not Installed
Event Output Function #3 Suspect Disabled or Not Installed
Parameter Number
Event Output Function #3 Trigger Condition Disabled or Not Installed
Event Output Function #4 Suspect Disabled or Not Installed
Parameter Number
Event Output Function #4 Trigger Condition Disabled or Not Installed
Event Output Function #5 Suspect Disabled or Not Installed
Parameter Number
Event Output Function #5 Trigger Condition Disabled or Not Installed
Event Output Function #6 Suspect Disabled or Not Installed
Parameter Number
Event Output Function #6 Trigger Condition Disabled or Not Installed
Event Output Function #7 Suspect Disabled or Not Installed
Parameter Number
Event Output Function #7 Trigger Condition Disabled or Not Installed
Event Output Function #8 Suspect Disabled or Not Installed
Parameter Number
Event Output Function #8 Trigger Condition Disabled or Not Installed
Air Filter Differential Pressure Sensor Activate Warning Condition
Diagnostic Response Configuration
Air Filter Differential Pressure Sensor No
Diagnostic Audible Alert
Air Filter Differential Pressure Sensor No
Diagnostic Breaker #1 Trip
Air Filter Differential Pressure Sensor No
Diagnostic Breaker #2 Trip
Ambient Air Temperature Sensor Activate Warning Condition
Diagnostic Response Configuration
Ambient Air Temperature Sensor No
Diagnostic Audible Alert
Ambient Air Temperature Sensor No
Diagnostic Breaker #1 Trip
Ambient Air Temperature Sensor No
Diagnostic Breaker #2 Trip
Engine Coolant Level Sensor Diagnostic Activate Warning Condition
Response Configuration
Engine Coolant Level Sensor Diagnostic No
Audible Alert
Engine Coolant Level Sensor Diagnostic No
Breaker #1 Trip
Engine Coolant Level Sensor Diagnostic No
Breaker #2 Trip
Engine Coolant Temperature Sensor Activate Warning Condition
Diagnostic Response Configuration
Engine Coolant Temperature Sensor No
Diagnostic Audible Alert
Engine Coolant Temperature Sensor No
Diagnostic Breaker #1 Trip
Engine Coolant Temperature Sensor No
Diagnostic Breaker #2 Trip
Engine Oil Level Sensor Diagnostic Activate Warning Condition
Response Configuration
Engine Oil Level Sensor Diagnostic Audible No
Alert
Engine Oil Level Sensor Diagnostic No
Breaker #1 Trip
Engine Oil Level Sensor Diagnostic No
Breaker #2 Trip
Engine Oil Pressure Sensor Diagnostic Activate Warning Condition
Response Configuration
Engine Oil Pressure Sensor Diagnostic No
Audible Alert
Engine Oil Pressure Sensor Diagnostic No
Breaker #1 Trip
Engine Oil Pressure Sensor Diagnostic No
Breaker #2 Trip
Engine Oil Temperature Sensor Diagnostic Activate Warning Condition
Response Configuration
Engine Oil Temperature Sensor Diagnostic No
Audible Alert
Engine Oil Temperature Sensor Diagnostic No
Breaker #1 Trip
Engine Oil Temperature Sensor Diagnostic No
Breaker #2 Trip
Engine Speed Sensor Diagnostic Activate Hard Shutdown Condition
Response Configuration
Engine Speed Sensor Diagnostic Audible Yes
Alert
Engine Speed Sensor Diagnostic Breaker No
#1 Trip
Engine Speed Sensor Diagnostic Breaker No
#2 Trip
Exhaust Temperature Sensor Diagnostic Activate Warning Condition
Response Configuration
Exhaust Temperature Sensor Diagnostic No
Audible Alert
Exhaust Temperature Sensor Diagnostic No
Breaker #1 Trip
Exhaust Temperature Sensor Diagnostic No
Breaker #2 Trip
Right Exhaust Temperature Sensor Activate Warning Condition
Diagnostic Response Configuration
Right Exhaust Temperature Sensor No
Diagnostic Audible Alert
Right Exhaust Temperature Sensor No
Diagnostic Breaker #1 Trip
Right Exhaust Temperature Sensor No
Diagnostic Breaker #2 Trip
Left Exhaust Temperature Sensor Activate Warning Condition
Diagnostic Response Configuration
Left Exhaust Temperature Sensor No
Diagnostic Audible Alert
Left Exhaust Temperature Sensor No
Diagnostic Breaker #1 Trip
Left Exhaust Temperature Sensor No
Diagnostic Breaker #2 Trip
Fire Extinguisher Pressure Sensor Activate Warning Condition
Diagnostic Response Configuration
Fire Extinguisher Pressure Sensor Audible No
Alert
Fire Extinguisher Pressure Sensor Breaker No
#1 Trip
Fire Extinguisher Pressure Sensor Breaker No
#2 Trip
Fuel Filter Differential Pressure Sensor Activate Warning Condition
Diagnostic Response Configuration
Fuel Filter Differential Pressure Sensor No
Diagnostic Audible Alert
Fuel Filter Differential Pressure Sensor No
Diagnostic Breaker #1 Trip
Fuel Filter Differential Pressure Sensor No
Diagnostic Breaker #2 Trip
Fuel Level Sensor Diagnostic Response Activate Warning Condition
Configuration
Fuel Level Sensor Diagnostic Audible Alert No
Fuel Level Sensor Diagnostic Breaker #1 No
Trip
Fuel Level Sensor Diagnostic Breaker #2 No
Trip
External Tank Fuel Level Sensor Activate Warning Condition
Diagnostic Response Configuration
External Tank Fuel Level Sensor No
Diagnostic Audible Alert
External Tank Fuel Level Sensor No
Diagnostic Breaker #1 Trip
External Tank Fuel Level Sensor No
Diagnostic Breaker #2 Trip
Generator Bearing #1 Temperature Sensor Activate Warning Condition
Diagnostic Response Configuration
Generator Bearing #1 Temperature Sensor No
Diagnostic Audible Alert
Generator Bearing #1 Temperature Sensor No
Diagnostic Breaker #1 Trip
Generator Bearing #1 Temperature Sensor No
Diagnostic Breaker #2 Trip
Generator Output Sensing System Activate Warning Condition
Diagnostic Response Configuration
Generator Output Sensing System Yes
Diagnostic Audible Alert
Generator Output Sensing System No
Diagnostic Breaker #1 Trip
Generator Output Sensing System No
Diagnostic Breaker #2 Trip
Engine Oil Filter Differential Pressure Activate Warning Condition
Sensor Diagnostic Response Config
Engine Oil Filter Differential Pressure No
Sensor Diagnostic Audible Alert
Engine Oil Filter Differential Pressure No
Sensor Diagnostic Breaker #1 Trip
Engine Oil Filter Differential Pressure No
Sensor Diagnostic Breaker #2 Trip
Primary Data Link Diagnostic Response Activate Warning Condition
Configuration
Primary Data Link Diagnostic Audible Alert No
Primary Data Link Diagnostic Breaker #1 No
Trip
Primary Data Link Diagnostic Breaker #2 No
Trip
Starting Air Pressure Sensor Diagnostic Activate Warning Condition
Response Configuration
Starting Air Pressure Sensor Diagnostic No
Audible Alert
Starting Air Pressure Sensor Diagnostic No
Breaker #1 Trip
Starting Air Pressure Sensor Diagnostic No
Breaker #2 Trip
Battery Charger Failure Diagnostic Activate Warning Condition
Response Configuration
Battery Charger Failure Diagnostic Audible Yes
Alert
Engine Controller Not Responding Activate Warning Condition
Diagnostic Response Configuration
Engine Controller Not Responding No
Diagnostic Audible Alert
Engine Controller Not Responding No
Diagnostic Breaker #1 Trip
Engine Controller Not Responding No
Diagnostic Breaker #2 Trip
Air Damper Closed Event Response Hard Shutdown & Active Only
Configuration Condition
Air Damper Closed Event Audible Alert Yes
High Air Filter Differential Pressure Activate Warning Condition
Warning Event Response Configuration
High Air Filter Differential Pressure Yes
Warning Event Audible Alert
High Air Filter Differential Pressure No
Warning Event Breaker #1 Trip
High Air Filter Differential Pressure No
Warning Event Breaker #2 Trip
High Air Filter Differential Pressure Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Air Filter Differential Pressure Yes
Shutdown Event Audible Alert
High Air Filter Differential Pressure No
Shutdown Event Breaker #1 Trip
High Air Filter Differential Pressure No
Shutdown Event Breaker #2 Trip
Low Air Filter Differential Pressure Warning Activate Warning Condition
Event Response Configuration
Low Air Filter Differential Pressure Warning Yes
Event Audible Alert
Low Air Filter Differential Pressure Warning No
Event Breaker #1 Trip
Low Air Filter Differential Pressure Warning No
Event Breaker #2 Trip
Low Air Filter Differential Pressure Warning Yes
Event Fault Protection Timer
Low Air Filter Differential Pressure Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Low Air Filter Differential Pressure Yes
Shutdown Event Audible Alert
Low Air Filter Differential Pressure No
Shutdown Event Breaker #1 Trip
Low Air Filter Differential Pressure No
Shutdown Event Breaker #2 Trip
Low Air Filter Differential Pressure Yes
Shutdown Event Fault Protection Timer
Emergency Stop Activated Event Activate Hard Shutdown Condition
Response Configuration
Emergency Stop Activated Event Audible Yes
Alert
Emergency Stop Activated Event Breaker No
#1 Trip
Emergency Stop Activated Event Breaker No
#2 Trip
High Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
High Engine Coolant Level Warning Event Yes
Audible Alert
High Engine Coolant Level Warning Event No
Breaker #1 Trip
High Engine Coolant Level Warning Event No
Breaker #2 Trip
High Engine Coolant Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Coolant Level Shutdown Yes
Event Audible Alert
High Engine Coolant Level Shutdown No
Event Breaker #1 Trip
High Engine Coolant Level Shutdown No
Event Breaker #2 Trip
Low Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Coolant Level Warning Event Yes
Audible Alert
Low Engine Coolant Level Warning Event No
Breaker #1 Trip
Low Engine Coolant Level Warning Event No
Breaker #2 Trip
Low Engine Coolant Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Coolant Level Shutdown Event Yes
Audible Alert
Low Engine Coolant Level Shutdown Event No
Breaker #1 Trip
Low Engine Coolant Level Shutdown Event No
Breaker #2 Trip
High Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Coolant Temperature Warning Yes
Event Audible Alert
High Engine Coolant Temperature Warning No
Event Breaker #1 Trip
High Engine Coolant Temperature Warning No
Event Breaker #2 Trip
High Engine Coolant Temperature Warning Yes
Event Fault Protection Timer
High Engine Coolant Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Engine Coolant Temperature Yes
Shutdown Event Audible Alert
High Engine Coolant Temperature No
Shutdown Event Breaker #1 Trip
High Engine Coolant Temperature No
Shutdown Event Breaker #2 Trip
High Engine Coolant Temperature Yes
Shutdown Event Fault Protection Timer
Low Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
Low Engine Coolant Temperature Warning Yes
Event Audible Alert
Low Engine Coolant Temperature Warning No
Event Breaker #1 Trip
Low Engine Coolant Temperature Warning No
Event Breaker #2 Trip
Low Engine Coolant Temperature Warning No
Event Fault Protection Timer
Engine Failure To Start Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Failure To Start Shutdown Event Yes
Audible Alert
Engine Failure To Start Shutdown Event No
Breaker #1 Trip
Engine Failure To Start Shutdown Event No
Breaker #2 Trip
High Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
High Engine Oil Level Warning Event Yes
Audible Alert
High Engine Oil Level Warning Event No
Breaker #1 Trip
High Engine Oil Level Warning Event No
Breaker #2 Trip
High Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Engine Oil Level Shutdown Event Yes
Audible Alert
High Engine Oil Level Shutdown Event No
Breaker #1 Trip
High Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Level Warning Event Yes
Audible Alert
Low Engine Oil Level Warning Event No
Breaker #1 Trip
Low Engine Oil Level Warning Event No
Breaker #2 Trip
Low Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Level Shutdown Event Yes
Audible Alert
Low Engine Oil Level Shutdown Event No
Breaker #1 Trip
Low Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Pressure Warning Event Yes
Audible Alert
Low Engine Oil Pressure Warning Event No
Breaker #1 Trip
Low Engine Oil Pressure Warning Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Yes
Fault Protection Timer
Low Engine Oil Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Pressure Shutdown Event Yes
Audible Alert
Low Engine Oil Pressure Shutdown Event No
Breaker #1 Trip
Low Engine Oil Pressure Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Shutdown Event Yes
Fault Protection Timer
High Engine Oil Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Oil Temperature Warning Yes
Event Audible Alert
High Engine Oil Temperature Warning No
Event Breaker #1 Trip
High Engine Oil Temperature Warning No
Event Breaker #2 Trip
High Engine Oil Temperature Warning No
Event Fault Protection Timer
High Engine Oil Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Oil Temperature Shutdown Yes
Event Audible Alert
High Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
High Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
High Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Low Engine Oil Temperature Warning Activate Warning Condition
Event Response Configuration
Low Engine Oil Temperature Warning Yes
Event Audible Alert
Low Engine Oil Temperature Warning No
Event Breaker #1 Trip
Low Engine Oil Temperature Warning No
Event Breaker #2 Trip
Low Engine Oil Temperature Warning Yes
Event Fault Protection Timer
Low Engine Oil Temperature Shutdown Disable Condition
Event Response Configuration
Low Engine Oil Temperature Shutdown No
Event Audible Alert
Low Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
Low Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
Low Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Unexpected Engine Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Unexpected Engine Shutdown Event Yes
Audible Alert
Unexpected Engine Shutdown Event No
Breaker #1 Trip
Unexpected Engine Shutdown Event No
Breaker #2 Trip
Engine Overspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Overspeed Shutdown Event Yes
Audible Alert
Engine Overspeed Shutdown Event No
Breaker #1 Trip
Engine Overspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Warning Event Activate Warning Condition
Response Configuration
Engine Underspeed Warning Event Audible Yes
Alert
Engine Underspeed Warning Event No
Breaker #1 Trip
Engine Underspeed Warning Event No
Breaker #2 Trip
Engine Underspeed Warning Event Fault Yes
Protection Timer
Engine Underspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Underspeed Shutdown Event Yes
Audible Alert
Engine Underspeed Shutdown Event No
Breaker #1 Trip
Engine Underspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Shutdown Event Fault Yes
Protection Timer
High Exhaust Temperature Warning Event Activate Warning Condition
Response Configuration
High Exhaust Temperature Warning Event Yes
Audible Alert
High Exhaust Temperature Warning Event No
Breaker #1 Trip
High Exhaust Temperature Warning Event No
Breaker #2 Trip
High Exhaust Temperature Warning Event No
Fault Protection Timer
High Exhaust Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Exhaust Temperature Shutdown Yes
Event Audible Alert
High Exhaust Temperature Shutdown No
Event Breaker #1 Trip
High Exhaust Temperature Shutdown No
Event Breaker #2 Trip
High Exhaust Temperature Shutdown No
Event Fault Protection Timer
Low Exhaust Temperature Warning Event Activate Warning Condition
Response Configuration
Low Exhaust Temperature Warning Event Yes
Audible Alert
Low Exhaust Temperature Warning Event No
Breaker #1 Trip
Low Exhaust Temperature Warning Event No
Breaker #2 Trip
Low Exhaust Temperature Warning Event Yes
Fault Protection Timer
Low Exhaust Temperature Shutdown Event Disable Condition
Response Configuration
Low Exhaust Temperature Shutdown Event No
Audible Alert
Low Exhaust Temperature Shutdown Event No
Breaker #1 Trip
Low Exhaust Temperature Shutdown Event No
Breaker #2 Trip
Low Exhaust Temperature Shutdown Event Yes
Fault Protection Timer
High Right Exhaust Temperature Warning Activate Warning Condition
Event Response Configuration
High Right Exhaust Temperature Warning Yes
Event Audible Alert
High Right Exhaust Temperature Warning No
Event Breaker #1 Trip
High Right Exhaust Temperature Warning No
Event Breaker #2 Trip
High Right Exhaust Temperature Warning No
Event Fault Protection Timer
High Right Exhaust Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Right Exhaust Temperature Shutdown Yes
Event Audible Alert
High Right Exhaust Temperature Shutdown No
Event Breaker #1 Trip
High Right Exhaust Temperature Shutdown No
Event Breaker #2 Trip
High Right Exhaust Temperature Shutdown No
Event Fault Protection Timer
Low Right Exhaust Temperature Warning Activate Warning Condition
Event Response Configuration
Low Right Exhaust Temperature Warning Yes
Event Audible Alert
Low Right Exhaust Temperature Warning No
Event Breaker #1 Trip
Low Right Exhaust Temperature Warning No
Event Breaker #2 Trip
Low Right Exhaust Temperature Warning Yes
Event Fault Protection Timer
Low Right Exhaust Temperature Shutdown Disable Condition
Event Response Configuration
Low Right Exhaust Temperature Shutdown No
Event Audible Alert
Low Right Exhaust Temperature Shutdown No
Event Breaker #1 Trip
Low Right Exhaust Temperature Shutdown No
Event Breaker #2 Trip
Low Right Exhaust Temperature Shutdown No
Event Fault Protection Timer
High Left Exhaust Temperature Warning Activate Warning Condition
Event Response Configuration
High Left Exhaust Temperature Warning Yes
Event Audible Alert
High Left Exhaust Temperature Warning No
Event Breaker #1 Trip
High Left Exhaust Temperature Warning No
Event Breaker #2 Trip
High Left Exhaust Temperature Warning No
Event Fault Protection Timer
High Left Exhaust Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Left Exhaust Temperature Shutdown Yes
Event Audible Alert
High Left Exhaust Temperature Shutdown No
Event Breaker #1 Trip
High Left Exhaust Temperature Shutdown No
Event Breaker #2 Trip
High Left Exhaust Temperature Shutdown No
Event Fault Protection Timer
Low Left Exhaust Temperature Warning Activate Warning Condition
Event Response Configuration
Low Left Exhaust Temperature Warning Yes
Event Audible Alert
Low Left Exhaust Temperature Warning No
Event Breaker #1 Trip
Low Left Exhaust Temperature Warning No
Event Breaker #2 Trip
Low Left Exhaust Temperature Warning Yes
Event Fault Protection Timer
Low Left Exhaust Temperature Shutdown Disable Condition
Event Response Configuration
Low Left Exhaust Temperature Shutdown No
Event Audible Alert
Low Left Exhaust Temperature Shutdown No
Event Breaker #1 Trip
Low Left Exhaust Temperature Shutdown No
Event Breaker #2 Trip
Low Left Exhaust Temperature Shutdown No
Event Fault Protection Timer
High Fuel Filter Differential Pressure Activate Warning Condition
Warning Event Response Configuration
High Fuel Filter Differential Pressure Yes
Warning Event Audible Alert
High Fuel Filter Differential Pressure No
Warning Event Breaker #1 Trip
High Fuel Filter Differential Pressure No
Warning Event Breaker #2 Trip
High Fuel Filter Differential Pressure Activate Hard Shutdown Condition
Shutdown Event Response Config
High Fuel Filter Differential Pressure Yes
Shutdown Event Audible Alert
High Fuel Filter Differential Pressure No
Shutdown Event Breaker #1 Trip
High Fuel Filter Differential Pressure No
Shutdown Event Breaker #2 Trip
Low Fuel Filter Differential Pressure Activate Warning Condition
Warning Event Response Configuration
Low Fuel Filter Differential Pressure Yes
Warning Event Audible Alert
Low Fuel Filter Differential Pressure No
Warning Event Breaker #1 Trip
Low Fuel Filter Differential Pressure No
Warning Event Breaker #2 Trip
Low Fuel Filter Differential Pressure Yes
Warning Event Fault Protection Timer
Low Fuel Filter Differential Pressure Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Low Fuel Filter Differential Pressure Yes
Shutdown Event Audible Alert
Low Fuel Filter Differential Pressure No
Shutdown Event Breaker #1 Trip
Low Fuel Filter Differential Pressure No
Shutdown Event Breaker #2 Trip
Low Fuel Filter Differential Pressure Yes
Shutdown Event Fault Protection Timer
High Fuel Level Warning Event Response Activate Warning Condition
Configuration
High Fuel Level Warning Event Audible Yes
Alert
High Fuel Level Warning Event Breaker #1 No
Trip
High Fuel Level Warning Event Breaker #2 No
Trip
High Fuel Level Shutdown Event Response Activate Hard Shutdown Condition
Configuration
High Fuel Level Shutdown Event Audible Yes
Alert
High Fuel Level Shutdown Event Breaker No
#1 Trip
High Fuel Level Shutdown Event Breaker No
#2 Trip
Low Fuel Level Warning Event Response Activate Warning Condition
Configuration
Low Fuel Level Warning Event Audible Yes
Alert
Low Fuel Level Warning Event Breaker #1 No
Trip
Low Fuel Level Warning Event Breaker #2 No
Trip
Low Fuel Level Shutdown Event Response Activate Hard Shutdown Condition
Configuration
Low Fuel Level Shutdown Event Audible Yes
Alert
Low Fuel Level Shutdown Event Breaker No
#1 Trip
Low Fuel Level Shutdown Event Breaker No
#2 Trip
External Tank High Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank High Fuel Level Warning Yes
Event Audible Alert
External Tank High Fuel Level Warning No
Event Breaker #1 Trip
External Tank High Fuel Level Warning No
Event Breaker #2 Trip
External Tank High Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank High Fuel Level Shutdown Yes
Event Audible Alert
External Tank High Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank High Fuel Level Shutdown No
Event Breaker #2 Trip
External Tank Low Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank Low Fuel Level Warning Yes
Event Audible Alert
External Tank Low Fuel Level Warning No
Event Breaker #1 Trip
External Tank Low Fuel Level Warning No
Event Breaker #2 Trip
External Tank Low Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank Low Fuel Level Shutdown Yes
Event Audible Alert
External Tank Low Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank Low Fuel Level Shutdown No
Event Breaker #2 Trip
Fuel Leak Event Response Configuration Activate Warning Condition
Fuel Leak Event Audible Alert Yes
Fuel Leak Event Breaker #1 Trip No
Fuel Leak Event Breaker #2 Trip No
High Engine Oil Filter Differential Pressure Activate Warning Condition
Warning Event Response Config
High Engine Oil Filter Differential Pressure Yes
Warning Event Audible Alert
High Engine Oil Filter Differential Pressure No
Warning Event Breaker #1 Trip
High Engine Oil Filter Differential Pressure No
Warning Event Breaker #2 Trip
High Engine Oil Filter Differential Pressure Activate Hard Shutdown Condition
Shutdown Event Response Config
High Engine Oil Filter Differential Pressure Yes
Shutdown Event Audible Alert
High Engine Oil Filter Differential Pressure No
Shutdown Event Breaker #1 Trip
High Engine Oil Filter Differential Pressure No
Shutdown Event Breaker #2 Trip
Low Engine Oil Filter Differential Pressure Activate Warning Condition
Warning Event Response Config
Low Engine Oil Filter Differential Pressure Yes
Warning Event Audible Alert
Low Engine Oil Filter Differential Pressure No
Warning Event Breaker #1 Trip
Low Engine Oil Filter Differential Pressure No
Warning Event Breaker #2 Trip
Low Engine Oil Filter Differential Pressure Yes
Warning Fault Protection Timer
Low Engine Oil Filter Differential Pressure Activate Hard Shutdown Condition
Shutdown Event Response Config
Low Engine Oil Filter Differential Pressure Yes
Shutdown Event Audible Alert
Low Engine Oil Filter Differential Pressure No
Shutdown Event Breaker #1 Trip
Low Engine Oil Filter Differential Pressure No
Shutdown Event Breaker #2 Trip
Low Engine Oil Filter Differential Pressure Yes
Shutdown Fault Protection Timer
High Starting Air Pressure Warning Event Activate Warning Condition
Response Configuration
High Starting Air Pressure Warning Event Yes
Audible Alert
High Starting Air Pressure Warning Event No
Breaker #1 Trip
High Starting Air Pressure Warning Event No
Breaker #2 Trip
High Starting Air Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Starting Air Pressure Shutdown Event Yes
Audible Alert
High Starting Air Pressure Shutdown Event No
Breaker #1 Trip
High Starting Air Pressure Shutdown Event No
Breaker #2 Trip
Low Starting Air Pressure Warning Event Activate Warning Condition
Response Configuration
Low Starting Air Pressure Warning Event Yes
Audible Alert
Low Starting Air Pressure Warning Event No
Breaker #1 Trip
Low Starting Air Pressure Warning Event No
Breaker #2 Trip
Low Starting Air Pressure Warning Event Yes
Fault Protection Timer
Low Starting Air Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Starting Air Pressure Shutdown Event Yes
Audible Alert
Low Starting Air Pressure Shutdown Event No
Breaker #1 Trip
Low Starting Air Pressure Shutdown Event No
Breaker #2 Trip
Low Starting Air Pressure Shutdown Event Yes
Fault Protection Timer
High Gas Pressure Warning Event Activate Warning Condition
Response Configuration
High Gas Pressure Warning Event Audible Yes
Alert
High Gas Pressure Warning Event Breaker No
#1 Trip
High Gas Pressure Warning Event Breaker No
#2 Trip
High Gas Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Gas Pressure Shutdown Event Yes
Audible Alert
High Gas Pressure Shutdown Event No
Breaker #1 Trip
High Gas Pressure Shutdown Event No
Breaker #2 Trip
Low Gas Pressure Warning Event Activate Warning Condition
Response Configuration
Low Gas Pressure Warning Event Audible Yes
Alert
Low Gas Pressure Warning Event Breaker No
#1 Trip
Low Gas Pressure Warning Event Breaker No
#2 Trip
Low Gas Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Gas Pressure Shutdown Event Yes
Audible Alert
Low Gas Pressure Shutdown Event No
Breaker #1 Trip
Low Gas Pressure Shutdown Event No
Breaker #2 Trip
Engine Intake Manifold Charge Activate Hard Shutdown Condition
Combustion Event Response Configuration
Engine Intake Manifold Charge Yes
Combustion Event Audible Alert
Engine Intake Manifold Charge No
Combustion Event Loss of Utility
Engine Intake Manifold Charge No
Combustion Event Breaker #1 Trip
Engine Intake Manifold Charge No
Combustion Event Breaker #2 Trip
Engine Intake Manifold Charge No
Combustion Event Fault Protection Timer
High Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
High Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
High Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Warning Event Fault Protection Timer
High Generator Bearing #1 Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Generator Bearing #1 Temperature Yes
Shutdown Event Audible Alert
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Low Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
Low Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
Low Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
Low Generator Bearing #1 Temperature Yes
Warning Event Fault Protection Timer
Low Generator Bearing #1 Temperature Disable Condition
Shutdown Event Response Configuration
Low Generator Bearing #1 Temperature No
Shutdown Event Audible Alert
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Earth Fault Event Response Configuration Activate Hard Shutdown Condition
Earth Fault Event Audible Alert Yes
Earth Fault Event Breaker #1 Trip No
Earth Fault Event Breaker #2 Trip No
Generator Winding #1 High Temperature Activate Warning Condition
Warning Event Response Configuration
Generator Winding #1 High Temperature Yes
Warning Event Audible Alert
Generator Winding #1 High Temperature No
Warning Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Warning Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Warning Event Fault Protection Timer
Generator Winding #2 High Temperature Activate Warning Condition
Warning Event Response Configuration
Generator Winding #2 High Temperature Yes
Warning Event Audible Alert
Generator Winding #2 High Temperature No
Warning Event Breaker #1 Trip
Generator Winding #2 High Temperature No
Warning Event Breaker #2 Trip
Generator Winding #2 High Temperature No
Warning Event Fault Protection Timer
Generator Winding #3 High Temperature Activate Warning Condition
Warning Event Response Configuration
Generator Winding #3 High Temperature Yes
Warning Event Audible Alert
Generator Winding #3 High Temperature No
Warning Event Breaker #1 Trip
Generator Winding #3 High Temperature No
Warning Event Breaker #2 Trip
Generator Winding #3 High Temperature No
Warning Event Fault Protection Timer
Generator Winding #1 High Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Generator Winding #1 High Temperature Yes
Shutdown Event Audible Alert
Generator Winding #1 High Temperature No
Shutdown Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Shutdown Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Shutdown Event Fault Protection Timer
Generator Winding #2 High Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Generator Winding #2 High Temperature Yes
Shutdown Event Audible Alert
Generator Winding #2 High Temperature No
Shutdown Event Breaker #1 Trip
Generator Winding #2 High Temperature No
Shutdown Event Breaker #2 Trip
Generator Winding #2 High Temperature No
Shutdown Event Fault Protection Timer
Generator Winding #3 High Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Generator Winding #3 High Temperature Yes
Shutdown Event Audible Alert
Generator Winding #3 High Temperature No
Shutdown Event Breaker #1 Trip
Generator Winding #3 High Temperature No
Shutdown Event Breaker #2 Trip
Generator Winding #3 High Temperature No
Shutdown Event Fault Protection Timer
Generator High Power Warning Event Activate Warning Condition
Response Configuration
Generator High Power Warning Event Yes
Audible Alert
Generator High Power Warning Event No
Breaker #1 Trip
Generator High Power Warning Event No
Breaker #2 Trip
High Ambient Air Temperature Warning Activate Warning Condition
Event Response Configuration
High Ambient Air Temperature Warning Yes
Event Audible Alert
High Ambient Air Temperature Warning No
Event Breaker #1 Trip
High Ambient Air Temperature Warning No
Event Breaker #2 Trip
High Ambient Air Temperature Warning No
Event Fault Protection Timer
High Ambient Air Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Ambient Air Temperature Shutdown Yes
Event Audible Alert
High Ambient Air Temperature Shutdown No
Event Breaker #1 Trip
High Ambient Air Temperature Shutdown No
Event Breaker #2 Trip
High Ambient Air Temperature Shutdown No
Event Fault Protection Timer
Low Ambient Air Temperature Warning Activate Warning Condition
Event Response Configuration
Low Ambient Air Temperature Warning Yes
Event Audible Alert
Low Ambient Air Temperature Warning No
Event Breaker #1 Trip
Low Ambient Air Temperature Warning No
Event Breaker #2 Trip
Low Ambient Air Temperature Shutdown Disable Condition
Event Response Configuration
Low Ambient Air Temperature Shutdown No
Event Audible Alert
Low Ambient Air Temperature Shutdown No
Event Breaker #1 Trip
Low Ambient Air Temperature Shutdown No
Event Breaker #2 Trip
Automatic Transfer Switch In Normal Active Only Condition
Position Event Response Configuration
Automatic Transfer Switch In Normal No
Position Event Audible Alert
Automatic Transfer Switch In Emergency Active Only Condition
Position Event Response Config
Automatic Transfer Switch In Emergency No
Position Event Audible Alert
High Battery Voltage Warning Event Activate Warning Condition
Response Configuration
High Battery Voltage Warning Event Yes
Audible Alert
High Battery Voltage Warning Event No
Breaker #1 Trip
High Battery Voltage Warning Event No
Breaker #2 Trip
High Battery Voltage Shutdown Event Activate Soft Shutdown Condition
Response Configuration
High Battery Voltage Shutdown Event Yes
Audible Alert
High Battery Voltage Shutdown Event No
Breaker #1 Trip
High Battery Voltage Shutdown Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Disable Condition
Response Configuration
Low Battery Voltage Warning Event Yes
Audible Alert
Low Battery Voltage Warning Event No
Breaker #1 Trip
Low Battery Voltage Warning Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Fault No
Protection Timer
Low Battery Charging System Voltage Disable Condition
Warning Event Response Configuration
Low Battery Charging System Voltage No
Warning Event Audible Alert
Low Battery Charging System Voltage No
Warning Event Breaker #1 Trip
Low Battery Charging System Voltage No
Warning Event Breaker #2 Trip
Low Battery Charging System Voltage No
Warning Event Fault Protection Timer
Engine In Cooldown Event Response Active Only Condition
Configuration
Engine In Cooldown Event Audible Alert No
Engine Speed-Generator Output Freq Activate Warning Condition
Mismatch Warning Event Response Config
Engine Speed-Generator Output Freq Yes
Mismatch Warning Event Audible Alert
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #1 Trip
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #2 Trip
High Fire Extinguisher Pressure Warning Activate Warning Condition
Event Response Configuration
High Fire Extinguisher Pressure Warning Yes
Event Audible Alert
High Fire Extinguisher Pressure Warning No
Event Breaker #1 Trip
High Fire Extinguisher Pressure Warning No
Event Breaker #2 Trip
High Fire Extinguisher Pressure Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Fire Extinguisher Pressure Shutdown Yes
Event Audible Alert
High Fire Extinguisher Pressure Shutdown No
Event Breaker #1 Trip
High Fire Extinguisher Pressure Shutdown No
Event Breaker #2 Trip
Low Fire Extinguisher Pressure Warning Activate Warning Condition
Event Response Configuration
Low Fire Extinguisher Pressure Warning Yes
Event Audible Alert
Low Fire Extinguisher Pressure Warning No
Event Breaker #1 Trip
Low Fire Extinguisher Pressure Warning No
Event Breaker #2 Trip
Low Fire Extinguisher Pressure Warning No
Event Fault Protection Timer
Low Fire Extinguisher Pressure Shutdown Activate Hard Shutdown Condition
Event Response Configuration
Low Fire Extinguisher Pressure Shutdown Yes
Event Audible Alert
Low Fire Extinguisher Pressure Shutdown No
Event Breaker #1 Trip
Low Fire Extinguisher Pressure Shutdown No
Event Breaker #2 Trip
Low Fire Extinguisher Pressure Shutdown No
Event Fault Protection Timer
Generator Control Not in Automatic Disable Condition
Warning Event Response Configuration
Generator Control Not in Automatic No
Warning Event Audible Alert
Generator Breaker Locked Out Warning Warning & Active Only Condition
Event Response Configuration
Generator Breaker Locked Out Warning Yes
Event Audible Alert
Generator Breaker Locked Out Warning No
Event Breaker #1 Trip
Generator Breaker Locked Out Warning No
Event Breaker #2 Trip
Utility Breaker Locked Out Warning Event Warning & Active Only Condition
Response Configuration
Utility Breaker Locked Out Warning Event Yes
Audible Alert
Utility Breaker Locked Out Warning Event No
Breaker #1 Trip
Utility Breaker Locked Out Warning Event No
Breaker #2 Trip
Earth Leakage Event Response Activate Hard Shutdown Condition
Configuration
Earth Leakage Event Audible Alert Yes
Earth Leakage Event Breaker #1 Trip No
Earth Leakage Event Breaker #2 Trip No
Emergency Power System Supplying Load Warning & Active Only Condition
Event Response Configuration
Emergency Power System Supplying Load No
Event Audible Alert
Low Cranking Voltage Warning Event Disable Condition
Response Configuration
Low Cranking Voltage Warning Event No
Audible Alert
Low Cranking Voltage Warning Event No
Breaker #1 Trip
Low Cranking Voltage Warning Event No
Breaker #2 Trip
Custom Event #1 High Warning Event Activate Warning Condition
Response Configuration
Custom Event #1 High Warning Event Yes
Audible Alert
Custom Event #1 High Warning Event No
Breaker #1 Trip
Custom Event #1 High Warning Event No
Breaker #2 Trip
Custom Event #1 High Warning Event No
Fault Protection Timer
Custom Event #1 High Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #1 High Shutdown Event Yes
Audible Alert
Custom Event #1 High Shutdown Event No
Breaker #1 Trip
Custom Event #1 High Shutdown Event No
Breaker #2 Trip
Custom Event #1 High Shutdown Event No
Fault Protection Timer
Custom Event #1 Low Warning Event Activate Warning Condition
Response Configuration
Custom Event #1 Low Warning Event Yes
Audible Alert
Custom Event #1 Low Warning Event No
Breaker #1 Trip
Custom Event #1 Low Warning Event No
Breaker #2 Trip
Custom Event #1 Low Warning Event Fault No
Protection Timer
Custom Event #1 Low Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #1 Low Shutdown Event Yes
Audible Alert
Custom Event #1 Low Shutdown Event No
Breaker #1 Trip
Custom Event #1 Low Shutdown Event No
Breaker #2 Trip
Custom Event #1 Low Shutdown Event No
Fault Protection Timer
Custom Event #1 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #1 Condition Exists Event No
Audible Alert
Custom Event #1 Condition Exists Event No
Loss of Utility
Custom Event #1 Condition Exists Event No
Breaker #1 Trip
Custom Event #1 Condition Exists Event No
Breaker #2 Trip
Custom Event #1 Condition Exists Event No
Fault Protection Timer
Custom Event #2 High Warning Event Activate Warning Condition
Response Configuration
Custom Event #2 High Warning Event Yes
Audible Alert
Custom Event #2 High Warning Event No
Breaker #1 Trip
Custom Event #2 High Warning Event No
Breaker #2 Trip
Custom Event #2 High Warning Event No
Fault Protection Timer
Custom Event #2 High Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #2 High Shutdown Audible Yes
Alert
Custom Event #2 High Shutdown Breaker No
#1 Trip
Custom Event #2 High Shutdown Breaker No
#2 Trip
Custom Event #2 High Shutdown Fault No
Protection Timer
Custom Event #2 Low Warning Event Activate Warning Condition
Response Configuration
Custom Event #2 Low Warning Audible Yes
Alert
Custom Event #2 Low Warning Breaker #1 No
Trip
Custom Event #2 Low Warning Breaker #2 No
Trip
Custom Event #2 Low Warning Fault No
Protection Timer
Custom Event #2 Low Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #2 Low Shutdown Event Yes
Audible Alert
Custom Event #2 Low Shutdown Event No
Breaker #1 Trip
Custom Event #2 Low Shutdown Event No
Breaker #2 Trip
Custom Event #2 Low Shutdown Event No
Fault Protection Timer
Custom Event #2 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #2 Condition Exists Event No
Audible Alert
Custom Event #2 Condition Exists Event No
Loss of Utility
Custom Event #2 Condition Exists Event No
Breaker #1 Trip
Custom Event #2 Condition Exists Event No
Breaker #2 Trip
Custom Event #2 Condition Exists Event No
Fault Protection Timer
Custom Event #3 High Warning Event Activate Warning Condition
Response Configuration
Custom Event #3 High Warning Event Yes
Audible Alert
Custom Event #3 High Warning Event No
Breaker #1 Trip
Custom Event #3 High Warning Event No
Breaker #2 Trip
Custom Event #3 High Warning Event No
Fault Protection Timer
Custom Event #3 High Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #3 High Shutdown Event Yes
Audible Alert
Custom Event #3 High Shutdown Event No
Breaker #1 Trip
Custom Event #3 High Shutdown Event No
Breaker #2 Trip
Custom Event #3 High Shutdown Event No
Fault Protection Timer
Custom Event #3 Low Warning Event Activate Warning Condition
Response Configuration
Custom Event #3 Low Warning Event Yes
Audible Alert
Custom Event #3 Low Warning Event No
Breaker #1 Trip
Custom Event #3 Low Warning Event No
Breaker #2 Trip
Custom Event #3 Low Warning Event Fault No
Protection Timer
Custom Event #3 Low Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #3 Low Shutdown Event Yes
Audible Alert
Custom Event #3 Low Shutdown Event No
Breaker #1 Trip
Custom Event #3 Low Shutdown Event No
Breaker #2 Trip
Custom Event #3 Low Shutdown Event No
Fault Protection Timer
Custom Event #3 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #3 Condition Exists Event No
Audible Alert
Custom Event #3 Condition Exists Event No
Loss of Utility
Custom Event #3 Condition Exists Event No
Breaker #1 Trip
Custom Event #3 Condition Exists Event No
Breaker #2 Trip
Custom Event #3 Condition Exists Event No
Fault Protection Timer
Custom Event #4 High Warning Event Activate Warning Condition
Response Configuration
Custom Event #4 High Warning Event Yes
Audible Alert
Custom Event #4 High Warning Event No
Breaker #1 Trip
Custom Event #4 High Warning Event No
Breaker #2 Trip
Custom Event #4 High Warning Event No
Fault Protection Timer
Custom Event #4 High Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #4 High Shutdown Event Yes
Audible Alert
Custom Event #4 High Shutdown Event No
Breaker #1 Trip
Custom Event #4 High Shutdown Event No
Breaker #2 Trip
Custom Event #4 High Shutdown Event No
Fault Protection Timer
Custom Event #4 Low Warning Event Activate Warning Condition
Response Configuration
Custom Event #4 Low Warning Event Yes
Audible Alert
Custom Event #4 Low Warning Event No
Breaker #1 Trip
Custom Event #4 Low Warning Event No
Breaker #2 Trip
Custom Event #4 Low Warning Event Fault No
Protection Timer
Custom Event #4 Low Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #4 Low Shutdown Event Yes
Audible Alert
Custom Event #4 Low Shutdown Event No
Breaker #1 Trip
Custom Event #4 Low Shutdown Event No
Breaker #2 Trip
Custom Event #4 Low Shutdown Event No
Fault Protection Timer
Custom Event #4 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #4 Condition Exists Event No
Audible Alert
Custom Event #4 Condition Exists Event No
Loss of Utility
Custom Event #4 Condition Exists Event No
Breaker #1 Trip
Custom Event #4 Condition Exists Event No
Breaker #2 Trip
Custom Event #4 Condition Exists Event No
Fault Protection Timer
Custom Event #5 High Warning Event Activate Warning Condition
Response Configuration
Custom Event #5 High Warning Event Yes
Audible Alert
Custom Event #5 High Warning Event No
Breaker #1 Trip
Custom Event #5 High Warning Event No
Breaker #2 Trip
Custom Event #5 High Warning Event No
Fault Protection Timer
Custom Event #5 High Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #5 High Shutdown Event Yes
Audible Alert
Custom Event #5 High Shutdown Event No
Breaker #1 Trip
Custom Event #5 High Shutdown Event No
Breaker #2 Trip
Custom Event #5 High Shutdown Event No
Fault Protection Timer
Custom Event #5 Low Warning Event Activate Warning Condition
Response Configuration
Custom Event #5 Low Warning Event Yes
Audible Alert
Custom Event #5 Low Warning Event No
Breaker #1 Trip
Custom Event #5 Low Warning Event No
Breaker #2 Trip
Custom Event #5 Low Warning Event Fault No
Protection Timer
Custom Event #5 Low Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #5 Low Shutdown Event Yes
Audible Alert
Custom Event #5 Low Shutdown Event No
Breaker #1 Trip
Custom Event #5 Low Shutdown Event No
Breaker #2 Trip
Custom Event #5 Low Shutdown Event No
Fault Protection Timer
Custom Event #5 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #5 Condition Exists Event No
Audible Alert
Custom Event #5 Condition Exists Event No
Loss of Utility
Custom Event #5 Condition Exists Event No
Breaker #1 Trip
Custom Event #5 Condition Exists Event No
Breaker #2 Trip
Custom Event #5 Condition Exists Event No
Fault Protection Timer
Custom Event #6 High Warning Event Activate Warning Condition
Response Configuration
Custom Event #6 High Warning Event Yes
Audible Alert
Custom Event #6 High Warning Event No
Breaker #1 Trip
Custom Event #6 High Warning Event No
Breaker #2 Trip
Custom Event #6 High Warning Event No
Fault Protection Timer
Custom Event #6 High Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #6 High Shutdown Event Yes
Audible Alert
Custom Event #6 High Shutdown Event No
Breaker #1 Trip
Custom Event #6 High Shutdown Event No
Breaker #2 Trip
Custom Event #6 High Shutdown Event No
Fault Protection Timer
Custom Event #6 Low Warning Event Activate Warning Condition
Response Configuration
Custom Event #6 Low Warning Event Yes
Audible Alert
Custom Event #6 Low Warning Event No
Breaker #1 Trip
Custom Event #6 Low Warning Event No
Breaker #2 Trip
Custom Event #6 Low Warning Event Fault No
Protection Timer
Custom Event #6 Low Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #6 Low Shutdown Event Yes
Audible Alert
Custom Event #6 Low Shutdown Event No
Breaker #1 Trip
Custom Event #6 Low Shutdown Event No
Breaker #2 Trip
Custom Event #6 Low Shutdown Event No
Fault Protection Timer
Custom Event #6 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #6 Condition Exists Event No
Audible Alert
Custom Event #6 Condition Exists Event No
Loss of Utility
Custom Event #6 Condition Exists Event No
Breaker #1 Trip
Custom Event #6 Condition Exists Event No
Breaker #2 Trip
Custom Event #6 Condition Exists Event No
Fault Protection Timer
Custom Event #7 High Warning Event Activate Warning Condition
Response Configuration
Custom Event #7 High Warning Event Yes
Audible Alert
Custom Event #7 High Warning Event No
Breaker #1 Trip
Custom Event #7 High Warning Event No
Breaker #2 Trip
Custom Event #7 High Warning Event No
Fault Protection Timer
Custom Event #7 High Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #7 High Shutdown Event Yes
Audible Alert
Custom Event #7 High Shutdown Event No
Breaker #1 Trip
Custom Event #7 High Shutdown Event No
Breaker #2 Trip
Custom Event #7 High Shutdown Event No
Fault Protection Timer
Custom Event #7 Low Warning Event Activate Warning Condition
Response Configuration
Custom Event #7 Low Warning Event Yes
Audible Alert
Custom Event #7 Low Warning Event No
Breaker #1 Trip
Custom Event #7 Low Warning Event No
Breaker #2 Trip
Custom Event #7 Low Warning Event Fault No
Protection Timer
Custom Event #7 Low Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #7 Low Shutdown Event Yes
Audible Alert
Custom Event #7 Low Shutdown Event No
Breaker #1 Trip
Custom Event #7 Low Shutdown Event No
Breaker #2 Trip
Custom Event #7 Low Shutdown Event No
Fault Protection Timer
Custom Event #7 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #7 Condition Exists Event No
Audible Alert
Custom Event #7 Condition Exists Event No
Loss of Utility
Custom Event #7 Condition Exists Event No
Breaker #1 Trip
Custom Event #7 Condition Exists Event No
Breaker #2 Trip
Custom Event #7 Condition Exists Event No
Fault Protection Timer
Custom Event #8 High Warning Event Activate Warning Condition
Response Configuration
Custom Event #8 High Warning Event Yes
Audible Alert
Custom Event #8 High Warning Event No
Breaker #1 Trip
Custom Event #8 High Warning Event No
Breaker #2 Trip
Custom Event #8 High Warning Event No
Fault Protection Timer
Custom Event #8 High Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #8 High Shutdown Event Yes
Audible Alert
Custom Event #8 High Shutdown Event No
Breaker #1 Trip
Custom Event #8 High Shutdown Event No
Breaker #2 Trip
Custom Event #8 High Shutdown Event No
Fault Protection Timer
Custom Event #8 Low Warning Event Activate Warning Condition
Response Configuration
Custom Event #8 Low Warning Event Yes
Audible Alert
Custom Event #8 Low Warning Event No
Breaker #1 Trip
Custom Event #8 Low Warning Event No
Breaker #2 Trip
Custom Event #8 Low Warning Event Fault No
Protection Timer
Custom Event #8 Low Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #8 Low Shutdown Event Yes
Audible Alert
Custom Event #8 Low Shutdown Event No
Breaker #1 Trip
Custom Event #8 Low Shutdown Event No
Breaker #2 Trip
Custom Event #8 Low Shutdown Event No
Fault Protection Timer
Custom Event #8 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #8 Condition Exists Event No
Audible Alert
Custom Event #8 Condition Exists Event No
Loss of Utility
Custom Event #8 Condition Exists Event No
Breaker #1 Trip
Custom Event #8 Condition Exists Event No
Breaker #2 Trip
Custom Event #8 Condition Exists Event No
Fault Protection Timer
Event Warning Condition Response Auto Enabled
Reset Enable Status
Event Audible Alert Response Auto Reset Enabled
Enable Status
Event Loss Of Utility Response Auto Reset Enabled
Enable Status
Event Breaker #1 Trip Response Auto Enabled
Reset Enable Status
Event Breaker #2 Trip Response Auto Enabled
Reset Enable Status
Generator Connection Configuration Wye (or Star) Connection
Generator Potential Transformer Primary 7200 Volts
Winding Rating
Generator Potential Transformer 240 Volts
Secondary Winding Rating
Generator Current Transformer Primary 300 Amps
Winding Rating
Generator Current Transformer Secondary 5 Amps
Winding Rating
Number of Generator Poles 4 Poles
Generator Rated Frequency 50 Hz
Generator Rated Voltage 6000 Volts
Generator Rated Power 1820 kW
Generator Rated Apparent Power 2275 kVA
Maximum Engine Speed Bias 400 rpm
Generator Nominal Output Frequency 50.0 Hz
Electronic Control Module Reduced Power Disabled
Mode Enable Status
Electronic Control Module Reduced Power 30 min
Mode Delay Time
Relay Output #1 Active State Configuration High
Relay Output #2 Active State Configuration High
Relay Output #3 Active State Configuration High
Relay Output #4 Active State Configuration High
Relay Output #5 Active State Configuration High
Relay Output #6 Active State Configuration High
Programmable Trip Point Function #1 Disabled or Not Installed
Trigger Condition
Programmable Trip Point Function #1 Disabled or Not Installed %
Percentage Threshold
Programmable Trip Point Function #1 Disabled or Not Installed %
Hysteresis Percentage
Programmable Trip Point Function #1 Trip Disabled or Not Installed sec
Activation Delay Time
Programmable Trip Point Function #1 Trip Disabled or Not Installed sec
Deactivation Delay Time
Programmable Trip Point Function #2 Disabled or Not Installed
Trigger Condition
Programmable Trip Point Function #2 Disabled or Not Installed %
Percentage Threshold
Programmable Trip Point Function #2 Disabled or Not Installed %
Hysteresis Percentage
Programmable Trip Point Function #2 Trip Disabled or Not Installed sec
Activation Delay Time
Programmable Trip Point Function #2 Trip Disabled or Not Installed sec
Deactivation Delay Time
Programmable Trip Point Function #3 Disabled or Not Installed
Trigger Condition
Programmable Trip Point Function #3 Disabled or Not Installed %
Percentage Threshold
Programmable Trip Point Function #3 Disabled or Not Installed %
Hysteresis Percentage
Programmable Trip Point Function #3 Trip Disabled or Not Installed sec
Activation Delay Time
Programmable Trip Point Function #3 Trip Disabled or Not Installed sec
Deactivation Delay Time
Programmable Trip Point Function #4 Disabled or Not Installed
Trigger Condition
Programmable Trip Point Function #4 Disabled or Not Installed %
Percentage Threshold
Programmable Trip Point Function #4 Disabled or Not Installed %
Hysteresis Percentage
Programmable Trip Point Function #4 Trip Disabled or Not Installed sec
Activation Delay Time
Programmable Trip Point Function #4 Trip Disabled or Not Installed sec
Deactivation Delay Time
Engine Serial Number Not Programmed
Display Pressure Units Configuration psi
Display Temperature Units Configuration Degrees Centigrade (Celsius)
Display Volume Units Configuration liters

Digital Voltage Regulator


Parameter Value
ECM Part Number 3147755-00
ECM Serial Number 34816053GD
Software Group Part Number 3184763-01
Software Group Release Date NOV2007
Software Group Description Regulator Software

Logged Diagnostic Codes [SHM: 599] - Digital Voltage Regulator


Code Description Occ. SHM First SHM Last RTC First RTC Last
No Logged
Diagnostic
Codes

Logged Event Codes [SHM: 599] - Digital Voltage Regulator


Code Description Occ. SHM First SHM Last RTC First RTC Last
611- 0 System Diagnostic Code 24 1:24:00 2:00:00 1/1/2000 1/1/2000
#1 : High - most severe 12:00:19 12:00:09
(3) AM AM
2456-17 Generator Total Reactive 99 57:15:00 435:36:00 1/1/2000 1/12/2000
Power : Low - least 12:50:49 9:20:25 AM
severe (1) AM

Active Diagnostic Codes [SHM: 599] - Digital Voltage Regulator


Code Description Occ.
No Active
Diagnostic
Codes
Active Event Codes [SHM: 599] - Digital Voltage Regulator
Code Description Occ.
No Active
Event Codes

Configuration - Digital Voltage Regulator


Description Value Unit
Voltage Regulator Power Input Frequency 200 Hz
Configuration
Potential Transformer Primary Winding 6000 Volts
Rating
Potential Transformer Secondary Winding 400 Volts
Rating
Current Transformer Primary Winding 300 Amps
Rating
Current Transformer Secondary Winding 5 Amps
Rating
Generator Connection Configuration Three Phase
Generator Rated Frequency 50 Hz
Generator Rated Voltage 6000 Volts
Generator Rated Current 208 Amps
Voltage Regulator Loss of Sensing 2.0 sec
Shutdown Event Notification Delay Time
Generator Rotating Diode Monitor 2.0 Amps
Shutdown Event Current Threshold
Generator Reverse VAr Shutdown Event 10 %
Percentage Threshold
Generator Reverse VAr Shutdown Event 3.0 sec
Notification Delay Time
Generator Reverse VAr Shutdown Event Activate Warning Condition
Response Configuration
Generator Over Voltage Shutdown Event 135 %
Percentage Threshold
Generator Over Voltage Shutdown Event 2 sec
Notification Delay Time
Generator Over Voltage Shutdown Event Activate Warning Condition
Response Configuration
Generator Under Voltage Shutdown Event 60 %
Percentage Threshold
Generator Under Voltage Shutdown Event 30 sec
Notification Delay Time
Generator Under Voltage Shutdown Event Activate Warning Condition
Response Configuration
Voltage Regulator Over Excitation 12.0 Amps
Shutdown Event Threshold
Voltage Regulator Over Excitation 10.0 sec
Shutdown Event Notification Delay Time
Voltage Regulator Over Excitation Definite Time
Shutdown Event Notification Delay Type
Voltage Regulator Fault Reset Switch Activate Warning Condition
Diagnostic Response Configuration
Generator Nominal Output Voltage 6000 Volts
Voltage Regulator Corner (Knee) 49.8 Hz
Frequency
Voltage Regulator Deviation From Corner 5.0 Hz
(Knee) Frequency
Voltage Regulator Volts/Hz Slope 1 2.0 V/Hz
Voltage Regulator Volts/Hz Slope 2 2.0 V/Hz
Voltage Regulator Minimum Voltage 50.0 %
Setpoint Percentage
Voltage Regulator Minimum Frequency 33.0 Hz
Threshold
Voltage Regulator Maximum Droop 0.0 %
Percentage
Voltage Regulator Voltage (IR) 0.0 %
Compensation Percentage
Voltage Regulator Starting Time 5.0 sec
Voltage Regulator Starting Voltage Percent 10.0 %
Voltage Regulator Noise Filter Time 0.00 sec
Constant
Voltage Regulation Proportional Gain 20.00 %
Percentage
Voltage Regulation Integral Gain 60.00 %
Percentage
Voltage Regulation Derivative Gain 3.00 %
Percentage
Voltage Regulator Gain Setting Selection 7
Number
Voltage Regulator Gain Setting Type User Defined
Configuration
Voltage Regulator Loop Gain Percentage 5.00 %
Maximum Generator Voltage Output Bias 15 %
Percentage Setpoint
Desired Voltage Input Configuration Invalid Data
Generator Nominal Output Power Factor 1.00
Voltage Regulator Nominal Reactive Power 0.0 %
Percentage
Generator Power Factor Controller Loop 0.30 %
Gain Percentage
Generator Power Factor Controller Integral 0.50 %
Gain Percentage
Voltage Regulator Load Compensation Off
Type Configuration
Voltage Regulator Power Factor/VAr Reactive Power
Controller Mode Selection
Voltage Regulator Desired Power Factor Lagging
Configuration
Generator VAr Controller Loop Gain 0.25 %
Percentage
Generator VAr Controller Integral Gain 0.50 %
Percentage
VAr / Power Factor Control Input Invalid Data
Configuration

You might also like