Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

Energy Ef�iciency

Power Quality

ACTIVE

Modular
Harmonic Mitigation
Solution
Optimize your harmonic compensation efficiency

+
1 3 5 7 9 11

1 3 5 7 9 11 1 3 5 7 9 11
Optimize your harmonic compensation efficiency

~
A
B
C

Uo

U
U/2 wt
0
-U/2
U

Uo

U flow
U/2 wt flow
0
-U/2
U

Uo

U
U/2 wt
0
-U/2
U
400V 400V
Items Items
Sinexcel AHF 005/010/015 Sinexcel AHF 025/035
Sinexcel AHF 005/010/015 Sinexcel
Sinexcel AHF AHF 050/060
025/035 Sinexcel
Sinexcel AHF AHF075/ Sinexcel
050/060 100 Sinexcel
AHF075/ 100AHF 150 Sinexcel AHF 150

System parameters
System parameters
Rated input Rated input 380V/415V(228V~456V)
380V/415V(228V~456V)
Power grid frequency 50/60Hz(range:45Hz~62.5Hz)
Power grid frequency 50/60Hz(range:45Hz~62.5Hz) 50/60Hz(range:45Hz~ 62Hz)
50/60Hz(range:45Hz~ 62Hz)
Parallel quantities Parallel quantities unlimited unlimited
Efficiency Efficiency ≥97% ≥97%
Power grid structure Power grid structure 3P3W, 3P4W 3P3W, 3P4W
CT CT 50/5~10000/5 50/5~10000/5 150/5 ~ 10,000/5 150/5 ~ 10,000/5
Circuit topology Circuit topology 3-level 3-level
Performance indicators
Performance indicators
Rated capacity Rated capacity 5/10/15A 5/10/15A 25A/35A 25A/35A 50A/60A 50A/60A 75A/100A 75A/100A 150A 150A
Harmonic compensation
Harmonic compensation Available Available
Reactive power compensation
Reactive power compensation Available Available
Unbalance compensation
Unbalance compensation Available Available
Control algorithm Control algorithm FFT,Intelligent FFT, and instantaneous
FFT,Intelligent reactive
FFT, and power reactive power
instantaneous
Operation mode Operation mode 12 combination, set12up priority
combination, set up priority
Filtering range Filtering range 2nd to 61th orders 2nd to 61th orders 2nd to 50th orders 2 nd to 50th orders
Filtering order Filtering order 2 to 61 orders 2nd to 61th orders 2 to 50 orders 2nd to 50 th orders
Filtering degree Filtering degree 2 to 61 orders nd th
2 to 61 orders 2 to 50 orders 2nd to 50 th orders
Filter performanceFilter performance >95% >95%
Reaction time Reaction time <15μs <15μs >50μs >50μs
Overall response timeOverall response time 5ms 5ms > 5ms > 5ms
Target power factor Target power factor Adjustable from -1Adjustable
to +1 from -1 to +1
Switching frequency Switching frequency 90KHz 90KHz average 20kHz,maximum
average35kHz
20kHz,maximum 35kHz
Cooling air requirement
Cooling air requirement 44L/Sec 44L/Sec 75L/Sec 75L/Sec 151L/Sec 151L/Sec 300L/Sec 300L/Sec 405L/Sec 405L/Sec
Noise level Noise level > 55dB > 55dB > 56dB > 56dB
Communications and monitoring capabilities
Communications and monitoring capabilities
Communications ports Communications ports RS485 RS485 RS485,and network port(RJ45)Ethernet port
RS485,and
Communications protocols
Communications protocols Modbus Modbus Modbus (RTU),TCP/IP(Ethernet)
Modbus (RTU)
Module display interface
Module display interface WIFI display WIFI display 4.3-inch HMI (mudule), 7-inch
4.3-inch HMIHMI(central monitor),
(module), 7-inch LED
HMI(central monitor), LED

Protection over-voltage
Protection functions functions protection, under-voltage
over-voltage protection,
protection, short-circuit
under-voltage protection,
protection, inverter
short-circuit bridge inverse
protection, protection,
inverter over-compensation
bridge inverse protection, and soprotection,
protection, over-compensation on and so on
monitoring alarm monitoring alarm Available Available
Fault alarm Fault alarm Available, at mostAvailable,
500 alarm at
records
most 500 alarm records
Mechanical properties
Mechanical properties
Mounting type Mounting typeWall-mounted/Rack-mounted
Wall-mounted/Rack-mounted Wall-mounted/Rack-mounted/Cabinet
Wall-mounted/Rack-mounted/Cabinet

440*490*150 440*590*190
440*490*150 440*590*190
440*600*230/500*600*190 500*560*267
500*600*190/440*600*230 500*560*269
400*325*44.5(Rack-mounted) (Rack- mounted) (Rack- mounted)
400*325*44.5(Rack-mounted) (Rack-mounted) (Rack-mounted) (Rack-mounted) (Rack-mounted)
(Rack-mounted) (Rack-mounted)
Dimensions (W x DDimensions
x H)mm (W x D x H) (mm³)
400*44.5*325(Wall-mounted) 440*150*470
400*44.5*325(Wall-mounted) 440*190*617
440*150*470 440*190*610
440*230*625/500*190*584 500*280*557
500*190*584 /440*234*625 500*286*557
(Wall- mounted) (Wall- mounted) (Wall- mounted) (Wall- mounted)
(Wall-mounted) (Wall-mounted) (Wall-mounted) (Wall-mounted)
Net weight Net weight 4.98kg 4.98kg 18kg 18kg 35kg 35kg 36kg 36kg 48kg 48kg
Color ColorBlack/gray/blue/orange/red (sand blast)
Black/gray/blue/orange/red (sand blast) Black Black
Environment requirements
Environment requirements
Altitude Altitude ≤1500 m; Between
≤1500
1500 m
m;to 4000 m, 1500
Between according to GB/T3859.2,
m to 4000 thetopower
m, according decreases
GB/T3859.2, the by 1% for
power every additional
decreases by 1% for100 m. additional 100 m.
every
Ambient temperature
Ambient temperature -20℃~40℃(may derate
-10℃~40℃ ( may
capacity if ambient temperature
derate capacity exceeds
if ambient 45℃)
temperature exceeds 45℃)
Relative humidity Relative humidity 5% to 95%, non-condensing
5% to 95%, non-condensing
Protection class Protection class IP20 IP20
Related qualifications and qualifications
Related standards and standards
Qualifications Qualifications CE, IEEE 61000, CE, IEEE 61000,
Standards compliance
Standards compliance IEEE519、ER G5/4 IEEE519、ER G5/4
We help customer success to reach our success 05/06 sinexcel
Saudi Arabia, Oil&Gas, AHF, Well Head
Germany, Transportation, AHF, Summit Bulk Carrier
China, commercial, AHF, Han Show by Wanda Group and Franco Dragone Entertainment Group

Singapore, commercial, AHF, Marina Bay Financial Center


Australia, industrial, AHF, BHP Billiton Group

United Kingdom, Commercial, AHF, Marks & Spencers


Chile, industrial, food product factory, AHF, Cecinas Llanquihue
New Zealand, Irrigation, AHF, Central Plains Water
Sinexcel AHF application covers Asia, Oceania, Europe, Africa, North America, South America.

You might also like