CONTACT THERMOMETERS No.

TD66E

Acc.

Series 34 and 35 Date 29-11-10

EC 10001 with remote indication Page 1(1)

GENERAL: AKM contact thermometers Series 34 for oil temperature and Series 35
for winding temperature can be fitted with precision potentiometers for
remote indication. The resistance characteristic of the potentiometer
gives a relationship between the indicated temperature on the thermo-
meter and the resistance of the potentiometer corresponding to that of
conventional resistance thermometers.
This gives several advantages over the conventional method with a
separate resistance thermometer: e.g. lower cost, no errors due to
different time constants etc.

TECHNICAL DATA: Housing: The potentiometer is mounted inside


the instrument, well protected.
Connections: According to TD 34.
Current: Max. 20 mA.
Accuracy:
(Related to local indication
excl. conn. lead wire error) ± 1,5 °C for Pt 100 ohms at 0 °C
± 3 °C for Cu 10 ohms at 25 °C
Ambient temperature: Min. –40°C max. +70°C.
Mechanical life: Meets BEBS-T2. Section XXVIII:
F2.1(a) requirement (min. 1000 hours
vibration test at 100 Hz and 0.2 to 0.25
mm vertical amplitude).
Breakdown test
voltage to earth: 2000 V, 50 Hz, 60 s.

TYPES: Corresponding to
resistance element: Pt 100 ohms at 0°C acc. to DIN IEC 751.
Cu 10 ohms at 25°C acc. to IEEE 119.

Qualitrol LLC. An ISO 9001 system Phone +46 8447 5460


certified company. Information subject Fax +46 8604 6810
to change without notice. Email akminfo@qualitrolcorp.com