Healthcare Lighting Fail-Safe

Healthcare Spaces Glossary of Terms


Term Definition Benefit

Fail-Safe Fail-Safe is a leading provider of specialty grade lighting products for the healthcare industry designed to perform in a
wide variety of complex environments. IP64
Dustproof; sealed against low pressure hose down
Dust cannot get into the lighting fixture. Lighting fixture can be cleaned by
spraying it down.
Fail-Safe’s complete family of luminaires are designed to meet the most demanding application needs in all healthcare
spaces including examination rooms, procedure rooms, operating rooms, patient rooms, MRI suites, and behavioral
health rooms. No dust can pass from the plenum to the room through this lighting
IP65 Dustproof; sealed against moderate pressure hose down
fixture. Can be easily cleaned by including hosing down the lighting fixture.

No dust can pass from the plenum to the room through the lighting
IP66 Dustproof; sealed against high pressure hose down fixture. Can be easily cleaned using high pressure
sterilization cleaning.

ISO 5 Fixture is certified for use in sterile cleanroom applications No air can pass through the lighting fixture between the room and the plenum space.

Antimicrobial Paint contains a special additive to prevent bacteria or germs Painting metal surfaces in antimicrobial finishes helps reduce the risk of HAIs (Hospital
Paint from growing and settling on metal surfaces Acquired Infections) in healthcare facilities.

Food safety rating; lighting fixture can be used in food Lighting fixture can be easily wiped clean. Paint is resistant to chipping. Materials used
NSF
processing and preparation areas contain no potentially harmful chemicals.

Ability of the lighting fixture to be easily wiped down without


Wipe Down Fixture is designed for easy cleaning, but not necessarily to the level of an NSF rating.
snags, or risk of cleaner entering the fixture
Examination Procedure Operating Patient MRI Behavioral
Room Room Room Room Suite Health
Applies to operating room lighting fixtures. Lighting fixtures do not create electronic
MIL-STD- Certification for lighting fixtures with limited conducted and
“noise” which could potentially interfere with sensitive
461-G radiated electromagnetic interference
operating room electronics.

2 4 6 8 10 12 Non-Ferrous Not containing any magnetic materials


Lighting fixture contains no steel that could cause interference or interaction with the
magnets used in an MRI machine.

Fail-Safe Healthcare Lighting Fail-Safe Healthcare Lighting 1


Examination Room Examination Room Fail-Safe
Design Light Levels Light Quality Ease of Cleaning
Features
• Moderate-to-high light levels • 80 CRI minimum, 90 CRI • Wipe down design allows easy cleaning of fixtures
• Variable light levels through switching or dimming preferred • Louvers and openings allow places for germs to
• Combined use of general and task lighting • Required to make qualitative hide and thrive so avoid if possible
within space color-based diagnoses • Antimicrobial finishes prevent germs from multiplying
on metal surfaces

Click on products
to learn more

Featured FCB UCL FLD4B (open)


Products
• Open center basket design • Medical undercabinet • Open medical downlight
• Decorative inlays available • Feature loaded - sensor, outlet, and switch • Aesthetics comparable to traditional
• Center basket design aligns with aesthetics downlights
of common spaces • CRI up to 97
• ViviidTuneTM White Tuning Technology

Sizes 1' x 4', 2' x 2', 2' x 4' 1', 2', 3', 4' 4'

Mounting Recessed Troffer Undercabinet Recessed Downlight

UL Location Damp Damp Wet

Max Lumens 7,500 2,400 4,000


Space Typically, the first step in treatment at a medical facility is a visit to an examination room. In an examination room, it is important to not have only sufficient CRI 80, 90 80, 90 80, 90, 97
Overview light but also high quality light to properly evaluate a patient’s condition. Recently, a shift has been made from utilitarian design of examination rooms to
Ease of Cleaning Wipe Down, Antimicrobial Wipe Down, Antimicrobial Wipe Down, Antimicrobial
a more aesthetically appealing layout. As part of this shift, the use of lighting that is visually aligned to common spaces in the facility has become more
prevalent in these rooms. IP Rating – IP63 (UCLV) IP65

NSF Rating – – Standard

2 Fail-Safe Healthcare Lighting Fail-Safe Healthcare Lighting 3


Procedure Room Procedure Room Fail-Safe
Design Light Levels Light Quality Sealed and Gasketed
Features
• High light levels required for performing minor • Minimum of 80 CRI • Room and equipment must be regularly sterilized
procedures • Color quality important in • Properly sealed fixtures aids in routine cleaning
• Proper light distributions needed to avoid glare on patient evaluations • Antimicrobial finish on metal surfaces to prevent
monitors and screens germ reproduction

Click on products
to learn more

Featured ENW SGI FLD6B


Products
• Low glare due to WavestreamTM technology • Sealed center basket design • Easy cleaning with clear full bottom lens
• Easy to clean • Electronics accessible below the • Medium distribution for optical control
• Visual alignment with non-medical spaces ceiling plane

Sizes 1' x 2', 1' x 4', 2' x 2', 2' x 4' 1' x 2', 1' x 4', 2' x 2', 2' x 4' 6"

Mounting Recessed Troffer Recessed Troffer Recessed Downlight

UL Location Wet Location Wet Location (Optional) Wet Location

Max Lumens 6,700 11,500 7,000


Space After or possibly instead of visiting an examination room, a patient will frequently be sent to a procedure room. These rooms are used for minor and minimally CRI 80, 90 80, 90 80, 90, 97
Overview invasive procedures where a local anesthetic may be used, but a general anesthetic is unnecessary. Since the patient is typically conscious, it is important to
Ease of Cleaning Wipe Down Wipe Down, Antimicrobial Wipe Down
maintain visual comfort for the patient while also ensuring sufficiently high light levels to perform procedures.
IP Rating IP66 IP65 IP66

NSF Rating Standard Optional Standard

4 Fail-Safe Healthcare Lighting Fail-Safe Healthcare Lighting 5


Operating Room Operating Room Fail-Safe
Design Light Levels and Quality Sealed and Gasketed Electromagnetic Interference (EMI) Control
Features
• Very high light levels • Prevent air from the plenum • Avoid interference with sensitive electronics
• Optical control needed to to avoid glare on screens space entering into the • Some ORs require MIL-STD-461 compliance
and monitors operating room

• Green LEDs can help with contrast and minimize • Improves ease of cleaning
glare the fixtures

Click on products
to learn more

Featured ORL FLD6B/OR


Products
• Operating room troffer • Downlight designed for operating room
• Green LEDs for glare reduction applications environments

• High lumen output • Certified for EMI control


• Easy to clean
• Light distribution designed to reduce glare

Sizes 1' x 4', 2' x 2', 2' x 4' 6"

Mounting Recessed Troffer Recessed Downlight

UL Location Wet Location Wet Location

Max Lumens 28,000 5,000

CRI 80, 90 80, 90, 87

Ease of Cleaning Wipe Down, Antimicrobial Wipe Down, Antimicrobial


Space In operating rooms, light levels and distributions are key requirements. Bright lights are used to illuminate the space to ensure proper visibility of the patient
Overview for surgeons and other medical staff. In addition, modern surgical suites have numerous monitors and displays so eliminating glare by optimizing the lighting
IP Rating IP66 IP66

layout is of utmost importance. NSF Rating Standard Standard

MIL-STD-461-G Optional Optional

6 Fail-Safe Healthcare Lighting Fail-Safe Healthcare Lighting 7


Patient Room Patient Room Fail-Safe
Design Mounting Location Light Levels Controls
Features
• Light location is determined by • Moderate-to-high light levels • Low voltage control for nurse call systems
the bed’s location • Single fixture needs to peform mulitple functions at • Dimming vs non-dimming
• Wall mount vs ceiling mount widely varied light levels
• Color temperature selectability to maintain patient comfort
• Light levels for every time of day

Click on products
to learn more

Featured MPBL MNAE MAE MCL


Products
• Headwall mounted • Designed to accommodate • Maximum light output from a • Wall mounted chart and
direct/indirect equipment being mounted single above-the-bed troffer night light
• Architectural-style aesthetics directly above the bed • Multi-function: ambient/exam/ • Photocell for nightlight, push
• Multi-function: ambient/exam/ nightlight/reading button for chartlight
nightlight/reading/chart light • Scoop design directs light
• Interface with nurse call only where desired
systems

Sizes 2', 3', 4' 8" x 36", 48", 54", 60" 2' x 2', 2' x 4' Single-Gang

Mounting Surface Wall Recessed Troffer Recessed Troffer Recessed Wall, Junction Box

UL Location Damp Location Wet Location Optional Damp Location Wet Location

Space The patient room is considered one of the most critical areas of a healthcare facility. Patients will typically spend several days in these rooms and it is Max Lumens
UP: 7100 Ambient: 3100 Ambient: 11000
30
Overview Down: 5500" Exam: 3000" Exam: 7000"
important to provide lighting that meets the needs of a variety of patient types. From reading and night lights to bright examination lights during doctor and
nurse visits, lighting in these spaces must fulfill a number of functions. Patients will also spend hours looking at these fixtures so maintaining an aesthetically CRI 80, 90 80, 90 80, 90 TBD
pleasing design and ensuring visual comfort is critical to enhancing patient satisfaction. Ease of Cleaning Wipe Down Wipe Down Wipe Down Wipe Down

IP Rating – – – –

NSF Rating – – – –

8 Fail-Safe Healthcare Lighting Fail-Safe Healthcare Lighting 9


MRI Suite MRI Suite Fail-Safe
Design Light Levels Non-Ferrous Electromagnetic Interference
Features
• Low-to-moderate light levels • Fixtures must be made from • Power supplies must be located outside of the MRI
• Use of decorative fixtures to create soothing non-magnetic materials room shielding area
environment • Incoming DC power must be filtered before entering
the room
• Unfiltered power or AC can cause issues in scan
results

Click on products
to learn more

Featured MRI-R6DNLT CV-LEL


Products
• Non-ferrous downlight • Decorative imagery fixtures
• Remote drivers capable of powering up to • Designed to mount on wall or ceiling
15 fixtures • Luminous scenery ceilings relax patients

Sizes 6" 2' x 2', 2' x 4' Various

Mounting Recessed Downlight Recessed Grid Surface Wall

UL Location Damp Damp Damp

Max Lumens 1,800 N/A N/A


Space
MRI (Magnetic Resonance Imaging) rooms use large magnets to create a magnetic field which can be analyzed to generate an image of the body or its parts.
Overview CRI 80 N/A N/A
As a result, any fixtures used in an MRI suite must be made using non-magntic components and generate no EMI (Electromagnetic Interference) from their
electrical components. It is important to provide a comforting and visually pleasing environment for patients as they undergo MRI scanning. Ease of Cleaning Wipe Down Wipe Down Wipe Down

Non-Ferrous Standard Optional Optional

Remote Driver Up to 15 fixtures 100W 1-per fixture

10 Fail-Safe Healthcare Lighting Fail-Safe Healthcare Lighting 11


Behavioral Health Behavioral Health Fail-Safe
Design Self-Harm Resistance Mounting Type Aesthetics
Features
• Lenses should be made of polycarbonate • Surface and wall mounted • Matte paint finishes that are less harsh vs. gloss finishes
and fasteners should be tamperproof fixtures present an increased maintain the look and feel of a healthcare facility while
• Edges and sides should be sloped to avoid risk of self harm by patients still keeping patient well being in mind
ligature points • Ceilings are typically sheetrock, • Fixtures providing visual alignment to non behavioral
requiring either integrally products is preferred to aid in patient well being
flanged fixtures or drywall kits

Click on products
to learn more

Featured FWL FCZ ENV FLD6B


Products
• Wall mounted high abuse behavioral health • Sealed center basket • Full bottom lens creates • Bottom trim ring
bedlight fixture tamper-resistant fixture resistant to abuse
• Steel construction and polycarbonate lens • Optics designed to create • Ligature resistant design • Trim ring on fixture
designed to withstand frequent abuse a relaxing mood for • Easy to clean prevents patient access
• Sloped sides create a ligature resistant design patients
• Architectural-style
• Matte finishes and diffuse optics create a • Polycarbonate lenses aesthetics
soothing environment withstand abuse

Sizes 18”, 24”, 48” 1' x 4', 2' x 2', 2' x 4' 1' x 2', 1' x 4', 2' x 2', 2' x 4' 6"

Mounting Surface Wall Recessed Troffer Recessed Troffer Recessed Downlight

UL Location Damp Location Wet Location Wet Location Wet Location

Max Lumens 6,000 7,500 6,100 7,000

Space CRI 80, 90 80, 90 80, 90 80, 90, 97


Lighting in behavioral or mental health facilities must perform all the functions of general ambient and specialized healthcare light fixtures while withstanding
Overview the high levels of physical abuse that can occur in these environments. Unfortunately, some patients may also attempt to engage in self-harm while residing in Ease of Cleaning Wipe Down, Antimicrobial Wipe Down, Antimicrobial Wipe Down Wipe Down, Antimicrobial
these facilities and light fixtures must be designed to resist these attempts by patients. While it is important for fixtures to be robust in design, they must also Lens Thickness Up to 0.250" Up to 0.250" 0.250" 0.250"
be visually comforting to patients. Use of institutional or correctional looking fixtures can be detrimental to patient well being.
IP Rating – IP65 IP66 IP66

NSF Rating – Standard Standard Standard

12 Fail-Safe Healthcare Lighting Fail-Safe Healthcare Lighting 13


Lighting Product Lines Controls Product Lines
Ametrix Fifth Light Technology
AtLite Greengate
Corelite iLight (International Only)
Ephesus iLumin
Fail-Safe Zero 88
Halo
Halo Commercial Connected Lighting Systems
Invue Distributed Low-Voltage Power
io HALO Home
Iris iLumin Plus
Lumark LumaWatt Pro
Lumière WaveLinx
McGraw-Edison Trellix
Metalux
MWS
Neo-Ray
Portfolio
RSA
Shaper
Streetworks
Sure-Lites

Cooper Lighting Solutions


1121 Highway 74 South
Peachtree City, GA 30269 Cooper Lighting Solutions is a
P: 770-486-4800 registered trademark.
www.eaton.com/lighting
All other trademarks are property
Canada Sales © 2020 Cooper Lighting Solutions of their respective owners.
5925 McLaughlin Road All Rights Reserved
Mississauga, Ontario L5R 1B8 Printed in USA Product availability, specifications,
P: 905-501-3000 Publication No. BR519046EN and compliances are subject to
F: 905-501-3172 January 22, 2020 9:45 AM change without notice.