Professional Documents
Culture Documents
Excel For Lighting
Excel For Lighting
1 SQUARE LIGHT 01 65
2 FLUORESCENT LIGHT 40
3 SQUARE LIGHT 02 52
4 CEILING FAN 80
5 EXHAUST FAN 80
6 MIRROR LIGHT 15
7 LIGHT SOCKET 100
8 POWER SOCKET 1000
9 GEYSER SOCKET 1500
10 AC SOCKET 2500
BED ROOM 01 BED ROOM 02 GUEST ROOM TOILET 01 TOILET 02
4 4 4 0 0
0 0 0 2 2
0 0 0 0 0
1 1 1 0 0
0 0 0 1 1
0 0 0 0 0
2 3 2 0 0
1 1 1 0 0
0 0 0 1 1
1 1 1 0 0
KITCHEN LIVING ROOM DINING ROOM BALCONY 01 BALCONY 02
3 4 2 0 1
0 0 0 0 0
0 0 0 1 0
0 1 1 0 0
1 0 0 0 0
0 0 0 0 0
2 4 0 0 0
2 0 2 0 0
0 0 0 0 0
0 1 1 0 0
POOJA ROOM UTILITY FOYER MIRROR LIGHT NO. OF UNITS
0 1 1 0 24
0 0 0 0 4
1 0 0 0 2
0 0 1 0 6
0 0 0 0 3
0 0 0 1 1
0 1 1 0 15
0 0 0 0 7
0 0 0 0 2
0 0 0 0 5
0
TOTAL WATTS
1560
160
104
480
240
15
1500
7000
3000
12500
26559
LIGHT CIRCUIT CALCULATION (LCK)
Room Identification : Bed Room 01 & Toilet 01
Light
S.No. Appliances Unit watts
Circuit No.
1 1 SQUARE CFL 65
2 CEILING FAN 80
3 FLUROSCENT LIGHT 40
4 EXHAUST FAN 80
5 LIGHT Socket 100
3 1 SQUARE CFL 65
2 CFL 52
CEILING FAN 80
LIGHT Socket 100
4 1 SQUARE CFL 65
2 CEILING FAN 80
3 LIGHT Socket 100
5 1 SQUARE CFL 65
2 FLUROSCENT LIGHT 40
3 EXHAUST FAN 80
4 LIGHT Socket 100
6 1 SQUARE CFL 65
2 CFL 52
3 CEILING FAN 80
4 LIGHT Socket 100
AC CIRCUIT CALCULATION
Room Identification : Bed Room 01, Bed Room 02, LIVING & DINING R
1 1 AC Socket 2500
2 2 AC Socket 2500
3 3 AC Socket 2500
4 4 AC Socket 2500
IT CALCULATION (LCK)
ion : Bed Room 01 & Toilet 01
No. of luminaries/
Points Total watts
appliances
4 2 260
1 1 80
2 1 80
1 1 80
3 3 300
8 800
tification : Bed Room 02
No. of luminaries/
Points Total watts
appliances
4 4 260
1 1 52
1 1 80
1 1 15
2 2 200
9 607
tion : Guest Room & Balcony
No. of luminaries/
Points Total watts
appliances
4 2 260
1 1 52
1 1 80
2 2 200
6 592
cation : DINING & Balcony
No. of luminaries/
Points Total watts
appliances
5 3 325
1 1 80
1 1 100
5 505
KITCHEN,Toilet 02 & UTILITY
No. of luminaries/
Total watts Points
appliances
4 260 2
2 80 2
2 160 2
2 200 2
700 8
on : LIVING Room & FOYER
No. of luminaries/
Points Total watts
appliances
3 2 195
1 1 52
1 1 80
3 3 300
7 627
UIT CACULATION(PCK)
ion : Bed Room 01 & Toilet 01
No. of Sockets Total watts Points
1 1000 1
1 1500 1
2500 2
n : Bed Room 02 & Guest Room
No. of Sockets Total watts Points
2 2000 2
on : DINING & LIVING Room
No. of Sockets Total watts Points
2 2000 2
tion : KITCHEN& UTILITY
No. of Sockets Total watts Points
1 1000 1
2 2000 2
3000 3
cation : Toilet 02 & FOYER
No. of Sockets Total watts Points
1 1000 1
2 2000 2
3000 3
UIT CALCULATION
01, Bed Room 02, LIVING & DINING Room
No. of luminaries/
Total watts Points
appliances
1 2500 1
1 2500 1
1 2500 1
1 2500 1
S.NO CIRCUITS LOCATION WATTS PHASE
R Y
1 L.C.K.1 BED ROOM 01 & TOILET 01 800 R1 _
P.C.K.1 BED ROOM 01 & TOILET 02 2500 R2 _
A.C.K.1 BED ROOM 01 & TOILET 03 2500 R3 _
R=8699
Y=8500 8853
B=8712
5R R
5Y Y
5B B
PHASE
B
_
_ 8853
_ 6407
2446
_
_
_
_
_
_
_
B1
B2
B3
Y4
B4
B5
1 2 3 4 5 6