Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

PRISMIC® Power Management Systems

Power without compromise

www.brush.eu
Introducing
BRUSH PRISMIC® PMS
Load Shedding The pressure of maintaining the We’ve been refining the design
high integrity power system that and functionality for over thirty
Generator Auto Dispatch your business depends on has just years, using our experience
been lifted. and expertise, coupled with
System Power & technological advancements, to
Var Control The BRUSH PRISMIC® Power add and improve features.
Management System is an
System Frequency extremely powerful and flexible Our PMS has none of the limitations
electrical power system controller. of generic PLC or off the shelf
& Voltage Control More than that, it’s your guardian equipment modules. Our PMS can
against outages and the ensuing be used with equipment from other
disruption and cost. OEMs, multiple types of generators
or prime movers and other
With a reputation for delivering a associated power system equipment.
reliable and stable power supply
whatever the industry or application PRISMIC® PMS is easy to use too.
PRISMIC® PMS sets the benchmark. Operators interact with a fully
That’s why it’s already the most featured Windows based Human
widely used PMS in the oil and gas Machine Interface (HMI) by using
industry in many parts of the world basic PC skills to navigate through
and is becoming widely used across the comprehensive and simple to
power and utilities sites, data centres, use displays and settings.
LNG terminals and military facilities.
Your operators can quickly become
PRISMIC PMS is designed and
®
familiar with the more challenging
produced by BRUSH, the world’s aspects of generation system
leading independent manufacturer control using the BRUSH power
of generators and associated system simulation and utilising real
equipment. We were one of the first generators at the BRUSH PRISMIC®
companies to use advanced digital training facility.
technology and we continue to
provide innovative solutions to meet
the most demanding specifications.
Each bespoke PRISMIC® PMS is BRUSH PRISMIC® PMS - a superior product with superior benefits
tailored to specific site requirements
• Improves power system security • Reduces the number of
and power system topology, with all
by managing energy requirements, personnel required through the
design data meticulously controlled
using multiple techniques, such automation of many processes.
and recorded.
as load shedding, generator auto
• Improves environmental
starting and load management.
The systems are fully designed and performance by aiding
tested by electrical engineers who • Optimises generator usage to implementation and operation
use real time simulations to fully minimise fuel consumption of DLN/DLE turbine emissions
demonstrate many scenarios which resulting in substantial cost savings. reduction systems.
can’t be easily tested on site. • Proactively highlights potential • Provides a clear visual
issues helping to avoid blackouts. representation of the power
By adopting these methods system, all necessary indications
commissioning time is cut • Minimises disturbance to
and alarm signals.
considerably and down time is operations.
minimised. A fundamental purpose • Automates sequencing of critical
• Accurately controls power
for PRISMIC® PMS is proactive circuit breaker operations reducing
flows and measures system
prevention of blackouts and enabling the risk of human error.
capabilities, rationalises
uninterrupted performance of generator usage and manages • Worldwide presence of BRUSH
critical processes and operations. type of fuel use. service engineers and our technical
support team provide you with
By preventing disturbances, • Comprehensive Training for your
expert advice and assistance when
the PRISMIC® PMS maximises team is available both on site and
you need it.
operational up time and at the BRUSH training facility.
minimises the costs associated • Remotely re-program multiple
• Whenever an event occurs it
with lost production. controllers to accommodate
is locally time stamped to 1ms
changes in the power system.
resolution before being stored or
exported.
Comprehensive functionality
with real flexibility
PRISMIC® PMS has been designed to Generator Set Management/
provide a comprehensive solution for Dispatch:
any industry, location and application,
• Automatic start sequence with low
from oil platforms to financial data
spinning reserve
centres. And we’ve made sure it’s
flexible enough to be tailored to your • Automatic start sequence prior to
specific organisation, to meet your large motor start
exact site requirements. • Automatic stop sequence with high
spinning reserve
Intelligent Load Shedding:
• Manual generator start and stop
• Fast acting initiated by sudden loss sequence initiation from HMI
of generating capability
• Neutral earthing contactor
• Generator gradual overload (automatic and manual)
shedding Data Transfer with External
• Black start Systems:
• Under frequency shedding
A wide range of communication
• Rate of change of frequency Additional Control Options: protocols are available for transfer
shedding • Load start inhibits of data to or from other systems
• Initiated by turbine pre-trip warning such as:
• Load reconnection
such as turbine exhaust over • DCS/SCADA
temperature (T5) • Controlled load reduction (VSD etc)
• IEDs
• Initiated by transformer or • Transformer tap-changer control
interconnector overload and monitoring • Switchgear

• Multiple or dynamic load • Protection relays


Powerful Human Machine
priority tables Interface (HMI): • Motor control centres
• Step load limiting • HMIs provide improved control and • Generator and turbine controllers
visualisation of the electrical power
Control of Voltage, Frequency, system Options for Increased Integrity:
Power, Mvar/Power Factor:
• Multiple networked workstations • Single location redundant master
• Power system frequency and can be fitted locally in control control modules – providing a local
voltage control panels and/or desk mounted hot standby
• Power sharing (MW and Mvar • Comprehensive trending and event • Multiple location redundant master
• Grid and interconnector power recording facilities are included control modules – autonomous
target control (MW, Mvar and PF) controllers take control of the
• HMIs can be used for operators to respective power system sections
• Individual generator baseload initiate commands for any required if the communications network is
target control (MW, Mvar and PF PMS functionality such as: divided
• Group set-point target (MW, Mvar - Generator starting and stopping
• Redundant input/output modules
and PF) - Busbar synchronising
• Redundant communication
• DLN/DLE operating modes - Opening/closing of circuit channels
• Voltage boosting facility breakers
- Multiple language HMI options
• Generator capability de-rating
are available
Power, speed, control
& versatility
Intelligent Load Shedding Generator Set Management/ • Active and reactive power levels
PRISMIC® PMS provides extremely Dispatch are fully controlled with power
rapid intelligent load shedding to shared evenly between all the
• The versatility of PRISMIC® PMS
prevent blackouts, which means generators or controlled to
enables it to interact with any
operational uptime is maximised specified target levels
manufacturer’s engine/ turbine
and disturbances to sensitive loads
and generator control systems, • Several modes of operation are
are minimised. Fast acting load
controlling any size of engine or available for each generator
shedding can be initiated in less than
generator. such as power factor control and
10ms and intelligent load shedding
reactive power control, baseload
algorithms ensure that only the • Generators can be manually
control etc
minimum number of load feeders started and stopped from the HMI
are tripped minimising disruption to • PRISMIC® PMS can actively control
• Generators can be automatically
operations. power factor and import/export of
started and stopped on load
power from a grid/utility network
demand
Load priority assignments are or another interconnected power
easily adjusted by operators using • Fuel types used for turbines can be generation system
the HMI software, or automatically controlled or monitored
• We use a real time closed loop
using intelligent algorithms, to suit • DLN/DLE emissions reduction simulation package to test
individual plant operational needs. functionality can be supervised by real scenarios in a controlled
PRISMIC® PMS environment. This simulation
Controlled load reduction is also package is also available for onsite
possible to avoid the need for load Load Start Inhibit training.
shedding, for example by reducing When the power generation system
thruster pitch. spinning reserve is low PRISMIC® Other Control Features
PMS is able to prevent additional Our flexible approach and extensive
Gradual overload, under frequency loads from being connected to the knowledge of designing Power
and rate of change of frequency load system. The HMI clearly displays all Management Systems allows us
shedding functions are also provided loads that are inhibited. to easily implement your custom
to protect the power system from a requirements.
cascade failure and blackout. Control of Voltage, Frequency,
• Circuit breakers, bus-ties and load
Power, Mvar/Power Factor
feeders can be both monitored
PRISMIC® PMS can be configured to
and controlled from the HMI
control system parameters to meet
demand requirements to satisfy • Control of neutral earthing
various combinations of operational resistors is available, as well as tap-
needs such as minimum energy changer control of transformers
usage, export or import of system
• PRISMIC® PMS can be configured
power as required by energy trading
to synchronise groups of
contracts or operation at particular
generators across bus-couplers
levels to ensure minimum emissions.
and interconnectors
• Steady state voltage and frequency
of the power system are accurately
controlled

Extremely rapid Intelligent load Shedding.


System Overview

DCS HISTORIAN

REMOTE
MONITORING

FIREWALL
PMS PMS SIMULATOR TIME
WORKSTATION WORKSTATION SYNCHRONISATION
SERVER

FIREWALL
PANEL HMI

CONTROLLER

ETHERNET
VARIOUS
SUBSTATION
OPTICAL /
NETWORK
SERIAL /
ETHERNET
NETWORKS

HARDWIRED I/O’S

T T T GRID GAS / DIESEL


ENGINE

G G G G

M M M
PRISMIC® PMS Features
Voltage control

Frequency control

Watts control

Engine and Generator Control VAr control

Grid target (Watts & Vars & PF)

Group target (Watts & Vars)

Generator targets (Watts & Vars & PF)


Gradual shedding
Under frequency shedding
Multiple level under frequency shedding
Rate of change of frequency shedding
Load Shedding Transformer overload protection
Interconnector overload protection
Load shed test facilities
Grid import limit
Generator breaker (on opening)
Generator protection (on operation)
Pre-trip warning (on alarm)
Turbine temperature HiHi (on alarm)
Interconnector/bus coupler fault
Transformer fault
Fast Acting Load Shedding Fast shed test
Multiple priority shed tables
Dynamic priority shed tables
IEC61850 GOOSE - trip input to shed output <10ms
Hardwired - trip input to shed output <40ms
Mixture of IEC61850 GOOSE and hardwired - trip input to shed outputs <40ms
Low spinning reserve
To replace set that has failed to start or synchronise
To replace set with pre-trip warning
Generator Starting Manual via HMI
Manual confirmation
Via DCS/SCADA
High spinning reserve
Generator/turbine warning
Generator Stopping Manual via HMI
Via DCS/SCADA
Real time deterministic Ethernet
Serial DCS/SCADA link
Ethernet DCS/SCADA
Serial IED interface

Communications Ethernet IED interface


OPC gateway
IEC61850 MMS Client, GOOSE Publisher and subscriber (Editions 1 and 2)
Time synchronisation
Multiple autonomous masters if comms fails
High speed HMI data refresh rate and trending (selectable down to 100ms)
High resolution event logging (1ms)
Ethernet PMS to HMI link

HMI Serial PMS to HMI link


Touch screen HMI
Multiple alarm priorities
Multi-language support
Group/multi set synchronising
Tap changer control
Enhanced dry low NOX control
Load start inhibit
Voltage boost for large motor start
Load reconnect
Manual circuit breaker control
Miscellaneous Black start
System training simulator
Temperature compensation
Dead bus check and closure
CB discrepancy monitoring and associated safe mode
Dual fuel compensation
Engine load cycling
BRUSH UK BRUSH CZ
Falcon Works Edvarda Beneše 564/39
Nottingham Road Doudlevce
Loughborough 301 00 Plzeň
Leicestershire Czech Republic
LE11 1EX T: +420 378 210 628
United Kingdom
T: +44 1509 611 511
BRUSH Americas
601 Braddock Avenue
Turtle Creek
BRUSH Transformers
Pittsburgh
Falcon Works
Pennsylvania 15145
Nottingham Road
USA
Loughborough
T: +1 412 829 7500
Leicestershire
LE11 1EX
United Kingdom
BRUSH NL
T: +44 1509 611 511
Riverside Offices, 5th Floor, Building II
Schaardijk 372
2909 LA Capelle aan den Ijssel
BRUSH Switchgear
The Netherlands
Unit 3
T: +31 103 123000
Blackwood Business Park
Newport Road
Blackwood
BRUSH Switchgear Australia
South Wales
Unit 6, 256 Leitchs Road
NP12 2XH
Brendale
United Kingdom
QLD. 4500
T: +44 (0) 1495 223 001
Australia
T: +61 7 3888 2333

BRU14081/11/19 www.brush.eu

You might also like