SHORT SPAN
L/4 CONTINUOUS
CONC. COVER
L/4
PLAN
RB
RB
RB
SECTION
SCHEDULE OF R.C. SLABS
RB RB SHORT SPAN LONG SPAN
SLAB TOP BARS TOP BARS t (mm) REMARKS
LOCATION BENT BOTTOM BENT BOTTOM
MARK
BARS CONTINUOUS BARS CONT. EXTRA BARS CONTINUOUS BARS CONT. EXTRA
2ND FLOOR S1 10Ø @ 300 10Ø @ 300 --- 10Ø @ 300 --- 10Ø @ 300 --- --- 125 1 - WAY
S2 10Ø @ 300 10Ø @ 300 --- 10Ø @ 300 10Ø @ 300 10Ø @ 300 --- 10Ø @ 300 125 2 - WAY
ROOF BEAM PLAN
SCALE: 1:100 M
SCHEDULE OF COLUMN
BEAM DEPTH
MARK C-1
VARIES
6" CHB
CONC. SLAB H/6
350
SECTION
50
F.F.L.
2-10mmØ RSB
VERIFY
250 X 300
GRAVEL
JOINT REINF.
350
N.G.L.
TIES
VERT.BARS 8 - 16mm Ø
10 mm Ø 10mm Ø LATERAL TIES SPACED @ 1-50mm,
VERTICAL TIES 6-100mm, REST @ 150mm
BARS @
60 MM O.C.
350
H
H/6 C-2
6" RSB
600
MARK
FINISH GRADE LINE
350
JOINT REINF.
@100mm O.C.
SECTION
FOOTING
175
_
as instrument of service, are the intelectual property and documents of the Architect,
7 14
SECTIONAL DETAIL OF RC.
CHECKED BY: whether the object for which they were made is executed or not. It shall be unlawful
ENGR. CRISTY M. MALASAN ADDRESS: for any person to duplicate or make copies of said documents for use in the repetition
STAIR
INSTRUCTOR
PRC REG. NO.: PTR NO.: CTC NO.: HOME ADDRESS: of and for other projects or buildings, whether executed partly or in whole, without the
SAN MIGUEL, GUIMBA, NUEVA ECIJA written consent of the architect or author of the said documents.
DATE:
SCHEDULE OF BEAM
VALIDITY: DATE ISSUED: DATE ISSUED:
TIN: PLACE ISSUED: MAY 12, 2017 PLACE ISSUED: GUIMBA, NUEVA ECIJA DATE APPROVED: