SNB SMB Pump Catalog PDF

You might also like

Download as pdf
Download as pdf
You are on page 1of 90
SHAKTI PUMPING LIFE SNB & SMB PUMPS SINGLE-STAGE END-SUCTION PUMPS 50 HZ SHAKTI La sao a OUD Meus ae dieu ead CONTENT smenours GENERAL DATA PAGE NO. GENERAL DATA PAGE NO. Applications ‘Curve charts Introduction 1 cure canons 18 Water supply 1 How to read the curve chats 19 Indust pressure boost 1 Isl res Dosing : Performance curve/ Tons! ata trnaton t NB, SMB 22-160. pote) 20-21 NB, SMB 32-160(2 pole 2223 Features and benefits NB, SMB 32-200(2 pale) 24.25 Features anabendits 2 NB, SMB 22-250(2 pol) 26.27 product range NB, SMB 40-125(2 pole) 2829 ‘SNB, SMB 50Hz, 2 Pole 2 ‘SNB, SMB 40-160(2 pole) 30-31 sue sot ae NB, SMB 40-200(2 pale) 32.8 NB, SMB 40-250(2 pale) 3435 dentifieation 'SNB, SMB 50-125(2 pole) 36-37 ‘Type key 4 'SNB, SMB 50-160(2 pole) 38-39 ‘Mechanical shaft seals 4 ‘SNB, SMB 50-200(2 pole) 40-41 Construction NB, SMB 50-250(2 pale) 4243 'SNB Cl Section drawing & Material Specification 5 'SNB, SMB 65-125(2 pole) 44-45 NBS Section drawing & Material Specticaon 5 NB, SMB 65-1600 pole) 46-47 ‘SNB Cl Section drawing & Material Speciation 6 NB, SMB 65:200(2 pole) 48.49 SB SS Section drawing & Material Specification «6 ‘NB, SMB 80-160(2 poe) 5051 Mechanical constuction 7 Mator 3 NB 32-160.1(4 poe) 5253 Prnkin age 8 SNE 32-160(4 pole) 5455 ‘NB 22-200(4 poe) 5657 Operating conditions she a0 125% poe) Sess Purp location 0 'SNB 40-160(4 pole) 60.61 Ambient temperature and attude 10 ne ao 200 or) ose Pumped iquids, 10 'SNB 40-250(4 pole) 64-65 ulema a NB 50-125 pl) sssr ‘Minimum Inlet pressure 12 ‘SNB 50-160(4 pole) 68-69 Calculation of maximum suction lift for waterin ‘SNB 50-200(4 pole) O71 open systems 2 NB 50-250(4 poe) 273 NB 65-125(4 pole) 14.98 Selection of product ‘NB 65-1604 pote) 18-17 ‘Pump size 13 'SNB 65-200(4 pole) 78-79 Efficiency 13 'SNB 80-160(4 pole) 80-81 Matesal 8 'SNB 80-200(4 pole) 82-83 Pumped iiquids Pumped liquids: 14-16 Accessories: Electrical data SNB/ SMB Cl suppar Block se Premium range 50Hz, 2 pole & 4 pole 7 Counter Ranges bad Ceraeirg tris prs elope orator peroneal cgi ee ocege APPLICATION INTRODUCTION The SNB/SMB series Is a mult-purpose pump range sultable for a varity of different applications demanding rellable and costeeficient supply. SNB/SMB pumps are used in four main fields of application: + Water Supply + Industrial pressure boosting + Industrial iquid transfer + Inrigation WATER SUPPLY Besides general water supply in municipal and indus-rial waterworks, the SNB/SMB pumps are used for these specific. applications: ‘Filtration and transfer at waterworks. Pressure boosting in mains Pressure boosting in high-rise buildings, hotels, ete. Pressure boosting in industrial buildings Various swimming bath applications. INDUSTRIAL PRESSURE BOOSTING Pressure boosting in + Industrial washing and cleaning systems + Industrial washdown systems, + Vehicle washing tunnels + Fire protection systems. INDUSTRIAL LIQUID TRANSFER. Liguid transfer in + Cooling and air-conditioning systems (refrigerants) + Boller feed and condensate systems + Aquafarming. + Industrial heating systems + District heating plants, IRRIGATION Irrigation covers these applic + Field irigation (flooding) + Sprinkler irrigation + Drip-eed irrigation, on SHAKTI FEATURES AND BENEFITS menos FEATURES AND BENEFITS ‘SNB/SMB pumps present these features and benefits + Motors are 50 He +The pumps are non-self-oriming single-stage, cen-rifugel_- + SNB/SMB pumps are available with 2 & 4 pole motors. volute pumps with axial suction por, radial discharge port and + SNB pumps are available with Premium range. horizontal shat. + Suction and discharge flanges are PN 10 or PN 16 according Toa great extent the pumps can be adapted to the tO EN 1092-2 requirements of the individual customer. For customized + Dimensions and rated performance are according to EN 733 solutions, please contact Shalt (20 bar) However, pumps with lange dimensions up to and including 1 DN 80 are marked PN 16 and thus suitable for 26 bar ‘SNB/SMB Cl, 50 Hz, 2-pole + The SNB pump is close-coupled with a totally enclosed fan- model | moset | sugernas | "Om cooled standard motor witn main dimensions to IEC and DIN a Standarés = sat +The SMB pump is single shaft monoblock end suction pump oo with a totaly enclosed far-eooled motor : sae + The mechanical shat seal has dimensions according to EN a 12786. sas ‘+ SNB pumps cover the performance range from 7 to 200 m’/hr a ssa and heeds from 3 to 97 m. Motor sizes fallin the 0.25 to 40 — iW range. sa + SMB pumps cover the performance range from 7 to 126 m’/hr = isan an neads from 910.78 m. Motor sizes fallin the 1.5 0 11 KW - a range — + All pumps are dynamically balanced according to 1S0 1940 aa class 6 3 impeles are hydraulically balanced sae + The SNB/SMB product range 's available “Premium range" + a product have IE3 motors : eas + The pumps are ofthe back pul-out design enabiing removal = aa and dismantling of the motor and impeller wthou disturbing : Parsi the pump housing or pipework. Consequents, even the largest = es pumps can be serviced bya single person witha crane, see - = Ft = anes Fig. 1 Back pull-out design = ara PRODUCT RANGE sis ‘The tabies onthe following pages show the complete SNB/SMB: a product rane. The standard ange has been combined on the Sa basis af the following parameters: = sane + Pump housings have discharge flanges from DN 32 to DN 80 : = [sues + Pump housings and motor stools are made of elecroxcoated aoa cast ron. Pump housing also have stainless steel fabricated. : — + Impelers are made of fabricated stainless steel or cast ron or : sa bronze, = ae + Nocirings are made of nortpps & bronze. : a + Shaft seals are BAQE and GQQE, Note mais nelated 1 avalebity of Product range 02 FEATURES AND BENEFITS ‘SNB, 50 Hz, 4-pole Pump €YPE | sw cimodel | Pressure stage PN 16 | P, (HP/iW] SoH, 4-pole 32:160.1 = 05/037 32-160 : : 075/055, 32200 = 10/075 ° ° 35/14 : : 03/0.25, 40-125 o : 05/037 : : 0.75/05 40360 : : 10/075 40-200 - - Ash = = 20/45 : . 3.0/2.2 40-250 = 40/30 soazs : : 075/055 = = 1.0/075 ° ° 35/11 50-160 * = 20/15 . * 3.0/2.2 50-200 - - — a . 40/30 50-250 * = 55/40 5125 . * 1.0/0.75 * * 15/14 1sft 65-160 . . 2.0/1.5 = 30722 a 30/22 65.200 . a 40/30 : : 55/40 5250 a o 75/55 : a 20/45 80-160 5 5 30722 : : 55/40 80-200 : o 75/55 Note :-* mark is indicated to availabilty of Product range 03 IDENTIFICATION TYPE KEY 'SNB/SMB Example SNB 22-160 2 42 A-F A -BAQE Type range Nominal diameter of discharge port (ON) Nominal impeller lameter [mm Reduced performance ‘Actual impeller diameter [mm Code for pump version (the codes may Be combined} ‘A= Basle version B= Without motor C= Puma housing with feet Code for pipework F=DIN flange Code for materials: A= Fabricated ss/os impeller/Cast ran and n+ pps necksing/ Bronze ron pump housing. wi fab. Code for mechanical shaft seal and rubber pump p MECHANICAL SHAFT SEALS 'SNB/SMB pumpsare available as standard with BAQE and GQQE shaft seals, Other shatt seal variants are available on request. Codes for mechanical shaft seal The positions (1) - (4) cover four pieces of information about the mechanical shaft seal: Example @) 2 4 ‘Shaki ype designation Material, rotating seal face ‘Material, stationary 5 Material, secondary seal and other rubber ‘and composite parts, except the wear ring Position Type A 8 6 D Position Type @ and @ = a Position Type e v ‘Short description of seal O-ring seal with fixed driver Rubber bellows seal Bellows seal, type 8, with reduced seal faces Oring seal, balanced Material ‘Synthetic earbons: ’A Carbon, metalimpregnated (antimony (70 paroved for potable water) ‘Carbon, synthetisresinimpregnated Carbides Silicon carbide Material POM FKM PM oa CONSTRUCTION smenours ‘SNB SECTIONAL VIEW AND MATERIAL SPECIFICATION SNB cl Sectional iow NB Cl Matera Specification AO@MOD om Component Matera eens) 3 [Motor Stoo! IGaST IRON // 7 Jeover Iss Alsi 304 Zi, | Ta [Pan Head Seren [SS Aisi304 a7 Ipirvent Pig lpRONZE 79a |Impeller Key Iss Aisi304 a 20 [Grub Serew [SS AISI 304 |26a,26b,26e| Nut Bolt Washer M.S (HT) Iss asst 204 38 [impeller sss 204/ INBR + PPS 20 |necwing NBR. Psy [Pump Housing [CAST IRON ! 42 [Spring Washer ISS AISI 304 | Si [eouoing shaft asiss-304 = Sia’ [Grub Serew [M.S (HT) | 66 [Washer [ss alsi304 4 67 [Hex Nut Iss ais1304 728 |ORing NBR 75 [suo IMs cam 79__|Hex. Nut lms a7) 705 [shaft Sear age 05a [Spacer for Shaft Seal_[SS AISI304 SNB SS Sectional view SNB SS Material Speciation Pes Conponeat | _Watral 3 [eter sit GASTRON 7 [over $5 A308 Ta__| Pan Head Seren | SSABI304 a7 [Avert Pug aRONZE i9a__[ peter Key $5 A81308 abar20n0=) Nut Bok Washer [WS GUT) =| 38 | inpeler Forested SS ASI a0 i 40, Neckring NBR + PPS | 7a] Pump Homing ae | $8 51 200 — 42 Sonng Washer SS ASI a0 i S14 Coupling shaft ‘AISI $S-304 Sia | Gab Serew MS HT) 6 | Washer SS ASI 308 7 Hes. ut 35 AS81308 72a | Gasket NBR 75 Alen aa SS ASTSOE 73 | Wxcap Not SS A108 305_[ shat Sea BRE 05a | Sacer for Shaf Seal] SS ABT304 Fig Sectional view 05 SHA CONSTRUCTION menos SMB SECTIONAL VIEW AND MATERIAL SPECIFICATION ‘SMB Cl Seetional vow SMB Ci Materia Specification BOOS Tes Component [nat 3 | eto End shits” [CAST RON a7 | Casing Cover ISISS-304 393 impel Key SS A204 20 | Grub Sorew SSAIST308 33 Splsh Ring NOR 34 | oiseal st 38 | npeterFabrented [SS ASTS08 40 | Neckring NBR + PPS “a1__| Pump Housing CASTIRON 42__| Spring Washer [SSaisi04 Si_| Shat wih Rotor [ASI SS-304 66 | Wester SS.AlS1 304 67 | Hex. Nut SS ASI304 72a | oRing NBR 73 | Std Ms tun) 73 | Hex Nak MSC) 405 | shat Sea GAGE 705a_| Spacer for Shah Seal | $5 AISI304 SMB SS Sectional view ‘SMB SS Material Specification Pow Conpenent Material 3_| Motor Ena Shield | CASTIRON 37 | Casing Cover ISISS.304 1¢8_| Impeller Key SS AISI 304 '33__| Splash Ring NBR 34_| o1rseat SID. 38__| impotiorFabricatoa | ss ais 304 40] Neckring NBR + PPS “41_| Pump Housing SSAISI 304 42 __| Spring Washer SSAISI 304 ‘51__| Shaft with Rotor AISISS304 65 | Washer SSAISI 304 67_| Hex Nut SSAISI 304 72a] Gasket NBR 75 _| Hex Bor SS AISI 304 79 | Hex Cap Nat SSalsi 204 305 | Shaft Seat BAQE 1058 _| Spacer for Shat'Seal | SS.AISI30a Fig.-6 Sectional view CONSTRUCTION MECHANICAL CONSTRUCTION Purp Housing The volute type pump housing is made of east iron and fabricated stainless steel and has axial suction port and radial discharge port. Flange connection dimensions are in accordance with EN 1092-2, The bottom of the pump housing cl incorporates a drain plug. The discharge port has a pressure gauge tapping. Fig- 6 Pump housing cast iron and fabricated ss 'SNB Motor stool and cover The cover is provided with a manual air vent screw for the venting of the pump housing and the shaft seal chamber, {An O-ring/gasket forms the seal between caver and pump housing. Coupling guards ae fted tothe motor stoo The flange sizeof the motor stools according to IEC 60034 for SNB model. NB Shaft/Couping The stainless steel shaft is 628, 638 mm. The coupling end of the shaft is cylindrical and has two drilled holes for the set screws of the coupling + Fig- 7 Shaft and coupling SNB pump 07 FEATURES AND BENEFITS Impeller The impeller is made from fabricated technology whichis ight weight which inerease the pump efficiency. The impeller is closed and has double-curved blades with smooth surfaces ensuring high efficiency. Fig. 8 Fabricated Impeller SNB, SMB pump Allimpellors are dynamically and hydraulically bal-anced. The hydraulical balancing compensates for axial thrust. The direction of rotation of the impeller is clockwise when viewed from the motor fan. Ifa certain duty point is required, pumps with reduced impeller diameter are available on request, ‘SMB Casing cover and motor/ pump bracket Motot/pump bracket assemble with motor body, Shaft seals fitted with casing cover. An O-ring or gasket for ms the seal between casing cover and pump housing. Shaft seal The shaft seal is an unbalanced, mechanical shaft seal with dimensions according to EN 12756. The seal faces are of carbon/silicon carbide. The code of the standard version is BAQE or GQQE. We recommend BAQE for high-temperature applications. The BAQE seal is not suitable for liquids contair-ing abrasive particles as ths will wear down the carbon face of the seal, We recommend GQQE for cooling applications involvingthe risk of precipitation on the seal faces. Flanges The suction and discharge flanges of SNB, SMB pumps are according to EN 1092-2, PN 10 or PN 16. For size and number of holes, see the table below: ‘Nonnal Diameter (OND st» nets) eo Ry] 3 80 «~~~ 150) 700 n© [a 150200 = 024001095145 _—160_380 240285 o, Ds 480 765185200220, EE) ee SAMS ado 4x94 Od BD Bes BS Surface treatment The cast iron parts of SNB, SMB pumps are electro-coated. Electto-coating includes: 1. Alkaline cleaning 2. Pre-treatment with zine phosphate coating 3. Cathodic electro-coating (epoxy) 4, Curing of paint flm at 200-250°C. The colour code of the finished product is NCS 8000/RAL 9005. 08 SHA FEATURES AND BENEFITS Test pressure Pressure testing of the pump housing was made with +20°C (~ +68°F) water containing corrosion inhibitor. Pressure Stage —_0verating Pressure _—CTestpressure___ ee PN 10 to Tas 3 PN 16 16 1624 2A MOTOR The motor is a totally enclosed, fan-cooled standard motor with main dimensions according to IEC and DIN standards. The tables on the following pages show the motors used for SNB model [As appears from the tables you can choose between + premium range with IE3 motors for SNB Pumps, Premium range including IES motors 2pole motors SOHz Output P Frame Size 7 w MGSO 2.0 15) SMG90 30 22 SMG 100 40 30 SMG 100 5S a0 SMG 132 75 55 SMG 132 10.0 75 SMG 160 15.0 Lo SMG 160, 20.0 15.0 SMG 160 25.0 185 SMG 180 30.0 22.0 SMG 200 40.0 30.0 SMG 200 50.0 37.0 Premium range including IES motors —__* Frame Size a SMG TL 0.25 SMG 7, 037 SMG 80 055 SMG 80 O75 SMG 90 SMG 90 SMG 100 SMG 112 SMG 132 SHAKTI OPERATING CONDITIONS Pump location The pump is designed for installation in a non-aggres-sive and non-explosive atmosphere. The relative alr humidity must not exceed 95%. ‘Ambient temperature and altitude The ambient temperature and the installation altitude are important factors for the motor fe, as they affect the life of the bearings and the insulation system. The instalation altitude isthe height ofthe installation site above sea evel. the ambient smperature exceeds the recommended maximum ambient temperature or maximum altitude above sea level, see fig 9, the ‘motor must not be fully loaded due to the low density and consequently low cooling effect of the air In such cases, it may be necessary o use a motor witha higher output. P2 4 100 90 80 70 60 50 20 25 30 35 40 45 50 55 60 65 70 75 80 tre] yo00 2250 3500 4750 m Fig.-9 Maximum motor output in relation to ambient temperature and altitude Example A pump with a 2.2 kW IE3 SMG motor: If the pump is installed 4750 m above sea level, the motor must not be loaded ‘more than 88 % of rated output. At an ambient temperature of 70 °C, the motor must not be loaded more that 88 % of rated output. f the pump is installed 4750 m above sea level at an ambient temperature of 70°C, the motor must not be loaded more than 88 % x 88 % equal to 77.4 % of the rated output Pumped iquid ‘SNK pumps are suitable for pumpingclean, thin, nonaggressive and non-explosive liquids, not containing any solid particles, ‘The effect of viscosity on centrifugal pump performance viscous liquid affects a centrifugal pump in several ways, ‘+The power consumption will be increased, I, e,a larger motor is required. + Head, flow rate and pump efficiency will be reduced ‘The effect of high density on centifugal pump performance A high density liquid only affects the power consumption of a centrifugal pump. + The head, flow rate and pump efficiency will remain unchanged. + The power consumption will increase at a ratio corresponding to the inerease in density. A liquid with a specific gravity of 1.2 will thus require a 20% larger power input. + An oversize motor wil often be required, ‘Shakti can help you select the right pump for liquids with viscosity/density diferent from those of water. 20 OPERATING CONDITIONS us guid temperatures The SNB, SMB pump range covers the temperature range from -25*C (~ -13°F) to #140°C (-+284°F). The permissible liquid temperature depends on the mechanical shaft seal type and pump type. See also table below. Relationship between mechanical shaft seals and temperature Mechanical Operating Maximum operating shaft seal temperature pressure [oa] BAQE Wote 20°C Tebar GQQE 125°C to 190°C 6 bar BQBE O°Cto HAO"C 6 bar BQQE. =25°C to 190°C ‘6 bar BQQV}) 0°61 190° 6 bar BBQE Oto H120°C 6 bar BAQV) (O°6 10 +90°C 6 bar aqqvy) =20°C 9 +90°C 6 bar BAQE and GQQE are standard shaft seals. The remaining shaft seal combinations in thelist re available for custom built pumps. 1) _The maximum temperature for FKM rubber is 80°C (~176°F) in liquids containing water. For liquids not containing water, such as pure oll, he seal faces of the mechanical shatt seal are the temperature limiting factor. Mechanical shaft seals with EPOM are primarily suitable for water. Ifthe water contains oi! or if chemicals or other liquids than water are pumped, you may have to replace tne rubber parts of the mechanical shaft seal FRM Mechanical shaft seals with FM (ox) rubber have excellent resistance against oll and a range of chemicals, (Carbon/silicon carbide Mechanical shaft seals with carbon/silicon carbide (xAQx) seal faces have a wide range of applications and are especially suitable if there is risk of dry running and/or if the temperature is high. These mechanical shaft seals are not suitable for liquids containing abrasive particles as the carbon parts will be worn. At tem-peratures below O°C (-+32°F) corrosion inhibitors containingabrasive particles will usually be added tothe pumped liquid, and xAQx seals willthus nat be suitable. Silicon carbide/sliconcarbide Mechanical shaft seals with silicon carbide/stlicon car-bide (xQQx) seal faces also have a very wide range of applications. These seals are very resistant to abrasive particles and well suited at quid temperatures up to +90°C (-+194°F). At higher temperatures the reduced lubricating properties ofthe pumped liquid may cause noise problems and limit the lfe of the seal faces i OPERATING CONDITIONS INLET PRESSURE ‘Maximum inlet pressure The actual inlet pressure + pressure when the pump is running against a closed valve must always be lower than the ‘maximum permissible operating pressure. The minimum inlet pressure must be according to the NPSH curve+ a safety margin of atleast 0.5 m ~ 1.66 fest + correction for vapour pressure. It is, however, advisable to calculate the inlet pressure i ‘The liquid temperature is high The flow rate is considerably higher than the pump's rated flow rate The pump is operating in an open system with suction it The liquid is sucked through long pipes. The inlet conaitions are poor The operating pressure is low, Calculation of maximum suction lift for water In open systems my HY Toavoid cavitation, make sure that there is a minimum pressure on the suction coy im side of the pump. The maximum suetion lft ‘Hin metres head can be $50. calculatedas folows: 45 culatedas fll 45 H= pbx 10.2 - NPSH- H.-H, ~H, wre 30 pb = Barometric pressure in bar. (Barometric pressure can be set to 1 1904 95 bar). In closed systems, p, indicates the system pressure in bar. NPSH = Net Positive Suction Head in metres head. (To be read from the 1207-20 NPSH curve atthe highest flow the pump will be delivering). 16 H, = Friction loss in suction pipe in metres head. (At the highest flow the 10 pump will be delivering.) % H, = Vapour pressure in metres head. (To be read from the vapour 100-410 pressure scale "H," depends on the liquid temperature 'T,”). 80 H, = Safety margin = minimum 0.5 metres head. Ifthe *H? calgulated is TO Positive, the pump can operate ata suction it of maximum "1" $0 metres head, 80 Ifthe "H" calculated is negative, an inlet pressure of minimum "H" metres 40 head is required, 70430 il e020 Ht 18 = 50. Oo 10 nl 40408 08 He s0t04 1 03 ~ T 2495 " 10. oa Pb ' ' 5 Hy rt Fig- 11 Relation betwoen liquid temperature Fig- 10 Schematic view of open system with SNB pump ‘and vapour pressure 12 SELECTION OF PRODUCT PUMP SIZE Selection of pump size should be based on: + Required flow and pressure at the drav-off point + Pressure loss as a result of height cifferences ‘+ Friction lass in the pipework It may be necessary to account for pressure loss in connection with long pipes, bends or valves, ete. + Best efficiency at the estimated duty point. EFFICIENCY Ityou expect the pump to always operate in the same duty point, select a pump which is operating in a duty point corresponding to the best efficiency of the pump. In case of controlled operation or varying consumption, select a pump whose best efficiency falls within the duty range covering the greater part of the duty time. MATERIAL The material variant should be selected on the basis of the liquid to be pumped, see List of pumped liquids page 13 13 PUMPED LIQUIDS PUMPED LIQUIDS ‘Maximum inlet pressure We recommend SNB, SMB pumps for thin, clean and non-aggressive, nomexplosive liquids, not containing solid particles or fibres. The liquid must not attack the pump materials chemically or mechanically. Ifyou pump liquids with a density and/or viscosity higher than that of water, use motors with correspondingly higher outputs, see “Pumped liquids” page 10, The mechanical shaft seal must be suitable for the liquid Water in heating and ventilating systems often contains additives to prevent negative effects such as system corrosion or calcareous deposits. f you want to use the pump for such liquids and ifthe temperature is above 80°C, use special shaft seals to avoid erystallization/precipitation between the seal faces. Liquid temperature: -25°C to +140°C. For heating systems, the water quality should meet VDI 2035. LUst of pumped quis ‘The list on the following pages gives an oveview of lig-uids which may typically be pumped by SNB, SMB pumps. The list states the recommenced shaft seals. Other shaft seals may be applicable, but we consider those stated in the lst to be the best eholees. The lists intended as a general guide only, and it can-not replace actual testing of pumped liquids and pump materials under specific working conditions. However, use the list with some caution as factors such as: + Concentration of the pumped liquid + liquid temperature + Prossure ‘may affect the chemical resistance of a specific pump version, Legend for notes inthe I ‘A May contain additives or impurities that may cause shaft seal problems. B The density and/or viscosity aiffer from that of water. Consider this when caleulating motor and pump performance. C The liquid must be oxygen-free (anaerobic). D__ Risk of chrystalization /precipitation in shaft seal E Due to the poor lubricating properties of the quid, dry running should be avoided. F The pumped liquid is easily ignited, G_The pumped liquid is flammable. H Insoluble in water. |The shaft seal rubber parts must be replaced with FAM rubber. J. The pump should run continuously to prevent discoloration of poo! ties, K Pump life may be reduced. SHA PUMPED LIQUIDS menos Pumped liquids Notes ‘Additional information Shaft seal Water Eg Baae Groundwater BAQE? >e90% BAGE! Boiler feed water <+120°C BAQE: DC -aTe Base District heating water <+120"C BAQE aC -140S OBE 00% Baae Condensate C= 120 BAQE 20-140 BOBE Softened water c 80" Book >90°C BAQE Brackish water aL pH>6.5, +40°C, 1000 ppm Cr BaGE ‘Sea water ae pH >6.5, +20°C, 20000 ppm Cr Baae ‘Swimming pool water aK pH>6.5, 40°C, 150 ppm Cr BaGE Cooling and eating lubricant Al Baav Coolants Ethylene gyeal 3D 750°C, 60% BQaEIGAGE Giycorne(alyeara BD 750°C, 60% BaaEIGAQE "yarocarbon based B.DFGI +50°C, 100% Baavicaay Poiassum aceiate De FEC, 5% BOGEISGGE Potassium formate B.D.C +50°C, 50% BQQEIGOGE Propylene giyeol BD BQQEGOGE Brine-sodium chloride B.D.C TOE BOQEIGOGE Brine-caleium nlonde BDC 350. 30% BaQE/GOGE Ethyl aleahol BDF aC BAQE Methyl aleahok- cooing BDF! id BAQE Fuels Diesel a EGA! 20°C, 100% BAQV Tet fo EGHI 20°C, 100% BAQV Kerosene) FEGHA 20°C, 100% BAG Naphia F.GHI 220°C, 100% BAG Peto GHAI 20°C. 100% BAG Mineral oils Cade of AB GI 20°C, 100% saav Mineral ubrcaing al 8.0.6 BAQVBQG Synthetic ols Silicone ol BH BAGETBGOE Synthetic lubricating a BGA BAQVIBGGV 1 SHAKTI PUMPED LIQUIDS Pumped liquids Notes ‘Additional information ‘Shaft seal Vegetable oils Corn of BLA BAQVIBGQV Olive oi BLA 806 BAQVIBQQV Peanut of BLA BAQVIBQQV. Rape seed ol 0.8, BAQVIBQGV Soya oll BLA BAQVIBQQV Cleaning ‘Soap (salts af fatly acs) ARO =80°S BOGE (BaQv), ‘kaline degreasing agent AH.) 00°C BOGE (BAQV) Organic solvents Isopropyl alcohol EG =60"C BAQE: Propyl alcohol RG =60°C BAQE, ‘Oxidants Hydrogen peroxide mn) 50 50 50) = om Miz mia mi waz 3 mm) 12 160) 360 360 A mn 189 195) 395 254 K mm) mia maa ia wa? 8 ml 140 120) TSNe mn 251 290) 290 320 8 mm 330 a3 a3 561 svscioara c mm) 60 136 136 08 P men 250 300) 300 350 TETWT- APR) | — Ika 76 30) 760 GROSS WT. APXT | — tka 35 100 170) L mn] 498) 572 572 64 up c1 AIA c mmm) Tar 21a 21a 375 NET WT. (APR _[ — tke ar 64 64 127 GROSS WT. (APXT [| thal 65 74 74 136) NOTE: For require of SNB/SMB SS gd, please contact to shalt 25 PERFORMANCE CURVE ‘SNB/SMB 32-250 (2 POLE) Lea ‘SNB/ SMB 32-250 2Pole, 50 Hz 180 9906:2012 Grade 38 Recommended suction x delivery pipe size [kW/H.P] 12.0/15.0 : 50x50mm [kW / HP] 15.0/20.0 : 50x50mm 26 PERFORMANCE TABLE ‘SNB/SMB 32-250 (2 POLE) Pump type 32-250 Matortipe High Eff. Motor ‘SMMG 160 SMG 160 P2 uw] 11/15 15/20 PN. par] 16 16 DNS mm} 50) 50, DNA [mm 32, 32 a Imm) 100 100 na. Imm 225 225 hd Imm] 180) 180 Ss axi9 x19 Sd axi9 x49 AD. [mm] 233 238) COMMON DATA GL [mm 162 162, ‘SNB/SMB Cl 2 [mm 178 178 mL Imm) 125) 125 m2 Imm 95 35 nd Imm] 320 320) n2. [mm 250 250) b [mm 65 65. st [mm Maz Miz i [mm 160) 160 A Imm} 254 254 K [mm] Maz Maz 5 Imm] 210) 210) LSNB Imm 342) 342) 1B mm 561, 561, NB cI DATA c [mm 108 108 P. [mm 350 350) NET WT. (APX) ke] 165 175 (GROSS WT. (APX) ke) 7s 187 L Tm] 688 : ss ci DATA c Imm 115) 7 NET WT. (APX) kel 132 7 (GROSS WT. (APX) ke) 142 i NOTE: For require of SNB/SMB SS gad, please contact to shakt PERFORMANCE CURVE ‘SNB/SMB 40-125 (2 POLE) wey "ab oNB/ SMB 40-125 7 a ole 20 Ne [-} a }s0 9808-2012 rade 38 | Recommended suction x delivery pipe size [kW / HP] 1.5/2.0 65x65 mm. ew / HP) 2.2/3.0, 65x65 mm 28 PERFORMANCE TABLE ‘SNB/SMB 40-125 (2 POLE) Pump type 40-125 Motor ype High Ef Motor ‘SMG ‘sMa90 Pp (kwh 15/2 22/3 PN, bar] 26 i DNS mm 65 5, DNA mm 40, 40 a mm 0 80 h2 {mm 140) 140 hi mm 112 412 ‘Ss 4x19) 4x9) Sd 4x19) 4x19) COMMON DATA AD imml 141 160 ‘SNB/SMB Cl Gt mm 115 115 G2 {mm 118) 118 im mm 100) 400 m2, mm 70 70. nd mm 210 210 n2 mm 160 160 b mm 50) 50) st mm Miz M12 ha mm 132) 132 A mm 584 554 K mm 9 a SNS mm 225 225 18 mm 280 327 sn cIDATA P mm 200 200 Ww mm a7 195 NETWT.(APX) Tal a7 48 GROSS WT. (APX) (kel 50) BL L mm] 460 500) SMB .cl DATA Ww mm 264 287 NETWT.(APX) Tel a2 a2 GROSS WT. (APX) eg) 45 a5 NOTE: For require of SNB/SMB SS gad, please contact to shakt PERFORMANCE CURVE menos ‘SNB/SMB 40-160 (2 POLE) wy eo e Na SMB 40-160 8 2-Pole, 50 Hz 180 9806-2012 rade 38 NPSH [m] Recommended suction x delivery pipe size [kW / HP] 3.0/4, 80x65 mm [kW / HP] 4.0/5.5 80x 65 mm (ew / HP] 5.5/7.5 65x50 mm. (lew / HP] 7.5/10.0 65x50 mm. 30 PERFORMANCE TABLE ‘SNB/SMB 40-160 (2 POLE) Pump type 40-160 Motor ype High Eff. Motor SmG100_| sw@100 | smeis2 | swG132 P2 (kW /HP] 3/4 ass | 55/78 | 75/10 PN, bar] 26 i6 26 6 DNS Imm) 65, 65 5, cy Na [mm 40, 40) 40) 40) a Imm 80, ED 80 80) h2 Imm 160 160 160) 160 ht Imm 132 132 132) 132 Ss x19 x19 x19 axi9 Sd x19 x19 x19) Axio coMMON ‘AD imml 370 170 132) 132 bata Gt Imm) 16 116 FET 116 SNB/SMB Cl ez Imm] 134) 134) 134) 134 md Imm) 100) 100 100) 100 m2 Imm) 70 70 70 70. ne Imm 240) 240 240) 240) na Imm 190 190) 190) 190 b [mm] 50, 50. 50, 50. si Imm Maz Maz M12 M2 hg Imm 112 112 160) 160 A Imm] 189 189 195) 195 K Imm a2 Maz Maz Miz 5 Imm) 140 140 420 120 SNE [mm 254) 254 293) 293 8 [mm 330) 330 413 413 ‘SNBCIDATA c Imm) 60. 60. 136) 136 P Imm 250) 250 300) 300 NETWT.(APX) kel 74 74 92 93, GROSS WI.(APX) | (ke) 34, a, 102 103 im] 498) 498 572 572, sme ciDara c Imm 447 147, 214 218 NETWT.(APX) ke) 60. 60) 5, 6 GROSS WT. (APK) | Tkl 70. 70 75, 75 NOTE: For requite of SNB/SMB SS gad, please contact to shakt 3 PERFORMANCE CURVE ‘SNB/SMB 40-200 (2 POLE) 7 Deraly fr ‘00 ‘SNB/ SMB 40-200 2-Pole, 60 Hz 180 9906:2012 Grade 38 Recommended suction x delivery pipe size (kW / HP] 5.5/7.5 65x50 mm. Uw / HP] 75/10.0 65x50 mm (kW / HP] 12.0/15.0 : 65x50 mm [kW/ HP] 15.0/20.0 : 65x50mm 32 PERFORMANCE TABLE menos ‘SNB/SMB 40-200 (2 POLE) Pump ype 40-200 Motor type High Eff. Motor ‘SMG 132 ‘SMG 132 ‘SMMG 160, 'SMMG 160 Ps www) [55/75 75/10 14/15 15/20 PN (bar 16 76 76 16 DNs: am 65 35 35 65 DNa nm 40 40) 40 40 a mm 00 00) 100) 00 he mm 180 180 180 180 Wi mm 160 160 160) 160) Se ants a9 axa9 axi9 Sd axis axi9 4x19 axi9 comMoN AD mm 132 132 233 233 ATA Gt nm 143 143; 143; 143; sNB/sMs cl @ mm 157, 157 157 357 om mm 100 700) 100 100 ma mm 70 70 70 70 mL mm 265 265 265 265 m2 mm 212 212 212. 212 > mm 50 50 50 50 Fn nm uaa waz waz maz ng mm 160 160) 160) 160 A mm 195) 195) 254 254 K mm a2 waz wiz Mi 3 mm 320 120 210 210 TSNE im ai2 312 3a 3a 16. mm 413. 413 561 561 sve CIDA c nm 136 136) 108 108; P mm 300 300 350 350 NET WT. (APR) | [a 2 97 162 169) GROSS WT. (AEX) | Tee 102 107, 472 180 L mm 592 592 685 smeci para c mm 215 215 138.5 NETWT. (APR) [th 66 58 129 GROSS WT. (APX) | Tae 76 76 139 NOTE: For require of SNB/SMB SS gad, please contact to shakt! 33 PERFORMANCE CURVE ‘SNB/SMB 40-250 (2 POLE) ‘SNB/ SMB 40-250 2-Pole, 50 Hz 180 9906:2012 Grade 38 Recommended suction x delivery pipe size [kW /H.P] 15.0/20.0 : 65x50mm [kW/ HP] 185/250 : 65x50mm [kW / HP] 22.0/30.0 : 65x65mm 34 PERFORMANCE TABLE ‘SNB/SMB 40-250 (2 POLE) Pump type 40-250 Motortype High EF Motor ‘sMwiG160 | SWMG160 | SMMG180 Pa URW 7H} 15/20 185/25 22/30 PN (bar) rd 36 16 DNs) {mm 65 65 65 DNd {rom 40 40 40 a (mm) 00 100 400 ha mm 225 225 225 hd {mm 180 180 180 Ss a9 4x19 ax Sa ax ax19 ax AD inn 233 233 236 Gi {rom 162 162 162 G2 [mm 182 182 182 ma mm 125 125) 125 SNB.CIDATA m2 {mmm 30 ‘80 90 nt {mm 320) 320 320 n2 mm 250 250 250 b {mmm 65 5 65 st mm) wa Maz Maz nS [mm 160 160 180 8 mm 210 254 241 A {rom 254 254 279 K (mm) Maz M12 a2 TSNB mm 342 342 342 iB {mmm 561 561 545 ¢ [mm 108 108 424 P mm 350 350 350 NETWTAAPK) | [ke] 476 247 240 GROSS WT. (APX) | [ke] 188 229 252 NOTE; For requite of SNB/SMB SS gad, please contact to shakt 35 PERFORMANCE CURVE ‘SNB/SMB 50-125 (2 POLE) bell to} ‘SNB/ SMB 50-125 3204 5. 2-Pole, 50 He Se 80 99082012 Grade 36| 240 Recommended suction x delivery pipe size (kW / HP] 3.0/4.0 80x65 mm [kW / HP] 4.0/5.5, 80x 65 mm (ew / HP] 5.5/7.5 80x 65 mm (lew / HP] 7.5/10.0 80x65 mm PERFORMANCE TABLE ‘SNB/SMB 50-125 (2 POLE) Pump ype 50-125 Motortwpe | High Ef Motor ‘SMG100__| SwG100 | sMG132__[_swG1s2 Pe URW HP] 3/4 4/55 55/15 75/10 PN Tard 16 16 16 16 DNs Imml 65 65 65 65 Nd Imm 50 50 50 50 a {mm} 100 200 100 100 he Imm) 160 160 460 160 ht Imm 132 132 132 132 Ss 4x19 4x19 x19 x19 Sa ax 4x9 4x9 4x19 COMMON AD. [mm 270 270 132 132 DATA Gi [ml a7 117 447 a7 ShB/SMB C1 @2 Imm 133 133 133 133 ma Imml 100 100 100 100 m2 Imml 70 70 70 70 nm Imm) 240 240 240 240 n2 {mm} 190 190 190 190 > Imm 50 50 50 50 st Imm Miz Maz M2 Miz ns Imml 12 112 160 160 A Imm) 189 189 195 195 K {mm} Miz Maz Maz Maz B Imm 140 140 120 120 USNS Imm 272 272 312 312 1B Imml 330) 330 413 43 NB CIDATA c [mm] 60 60 136 136 P {mm} 250 250 300 300 NET WT. (APX) kg] 77 77 92 93 GROSS WT.(APX) | [kel 7 87 401 102 L Tmml 518 51s 590 590 sM3 CI DATA c [mm a7 a7 214 214 NET WT.APK) he) 58 59 64 64 GROSS WT.(APX) | [kel 67 8 7 7 NOTE: For raquite of SNB/SMB SS gad, please contact to shakt 37 PERFORMANCE CURVE ‘SNB/SMB 50-160 (2 POLE) SNB/ SMB 50-160, ‘2Pole, 60H 1S0 9806:2012 Grade 35 Recommended suction x delivery pipe size (kW / HP] 5.5/7.5 80x65 mm Uw / HP] 75/10.0 80x 65 mm (kW / HP] 12.0/15.0 : 80x65mm [kW/ HP] 15.0/20.0 : 80x65mm 38 PERFORMANCE TABLE ‘SNB/SMB 50-160 (2 POLE) Pump type 50-160 Motor ype High Eff, Motor smeis2_[ swais2 | swwgi6o_| swwGi160 Ps wn) [55/75 75/10 1/15 15/20 PN [bar] 26 26 16 16 DNS, Imm 5, 5 65 65 Na [ml 50) 50) 50) 50 a 100 100 100 100 ha 180 180 180) 180) ha 160 160 160 160 Ss xd axi9 4x19 4x19 Sd axi9 axi9 a9 4x19) common AD. Imm 132 132 233) 233) ATA Gt [mm 150 150 150 150 ‘SNB/SMB Cl o [nm 125 125 125 225 mt [mm 100 100 100 100 m2, [ml 70 70 70 70 nd, [mm 265) 265) 265, 265, m2 [mm 212, 212 212 212 b Imm) 50, 50) 50) 50 st [mm] Miz Maz Maz Maa i Imm 160 160 160) 160 A [mm 195 195 254 254 K [mm Miz Maz Maz. Miz 5 [mm 120 120) 210 210 SNE [ml 312, 312, 342 342) LB Imm 413 413 561 561 SNBCIDATA c lnm 136 136 108 108 P. Imm 200) 300) 350) 350) NETWT.(APX) Tk 93, 96 170 185 GROSS WT (APX) | [kel 02 105 180) 197 L Tmml 592, 592 685 z sme ci DATA c [mm 215) 215) 139 7 NET WT. (APX) Thal 66 66 135 : GROSS WT (APX] | [eg) 76 76 145 z NOTE: For requite of SNB/SMB SS gad, please contact to shalt 39, PERFORMANCE CURVE menos SNB 50-200 (2 POLE) ta [ea] | for] . SNBY SMB 50-200 2-Pole, 50 Hz 2004 180 9906:2012 Grade 38 zany = — NPSH — te] 4 = 200 osu > Recommended suction x delivery pipe size [kW /H.P] 22.0/30.0 : 80x65 mm. 40 PERFORMANCE TABLE menos SNB 50-200 (2 POLE) Pump ype 50-200 Motor ype High EW Motor SMG 180 Bs KWH 22/30) PN (earl 16 DNs tom) 3 DNA tow 50 2 tram 100 na tr 200) rm (rom) 160 Se axi9 Sd axi9 AD inn 236 a (rom) 150 2 trv) 470 ma tmnt 700) svecioaa m2 ton) 70 mH mm 270) na ten) 212 D tram 50 = tram waa 7 trom 180 A mm) 279 K (mm) Ma2 8 mm 241 TSN mm 363 8 tom) 545; c (rom) 124 P ton 350 NETWT.TAPX) ta 322. GROSS WT. (APX) tha 332, 41 PERFORMANCE CURVE SNB 50-250 (2 POLE) Leal tw ‘SNB/ SMB 50-250 2-Pole, 50 Hz 1S0 9906:2012 Grade 3B NPSH [m] Recommended suction x delivery pipe size [kW /H.P] 30.0/40.0 : 80x80mm [kW / HP] 370/500 : 100x65mm a2 PERFORMANCE TABLE SNB 50-250 (2 POLE) Pump type Motor 'SNB C1 DATA, High Eff Motor Pa PN DNs. NG h2 hi ‘Ss Sa AD. G1 G2 ma m2, nd n2 a1 hs A K 5 1B c - NET WT (APX) “GROSS WT. (APX) KW/HP] bar] [mm Tam mm [mm mm [mm [mm [mm [mm rT r 80-250 ‘SMIMG 200 30/40 16 65. 50. 100 234 750 ant ax9) 276 170 188 125 95, 320 250 65. mia 200 318 M16 305 354) 650 133 “4001 366 376 'SWIMG 200, 37/80 i 65, 50. 100 234 780 axi9 4x19 276 170. 188 125 95 320 250) 65, a3 PERFORMANCE CURVE ‘SNB/SMB 65-125 (2 POLE) ‘SNB/ SMB 65-125 2-Pole, 50 Hz 30 9908:2012 Grade 38 2a-few 240-4] 24 [25k 5.5 Recommended suction x delivery pipe size [kW / HP] 4.0/5.5 [kW / HP] 55/75 (kW / HP] 7.5/10.0 ew / HP] 1.0/1.0 100 x 80 mm 100 x 80 mm 100 x80 mm 100 x80 mm PERFORMANCE TABLE ‘SNB/SMB 65-125 (2 POLE) Pump type 65-125 Motortype | _High Ef. Motor SMGi00 | swais2 | sw@i32 | SMMG160 Pe wwwHe) | 4/55 55/75 | 75/10 11s PN. [bar] 16 16 16 16 DNs: Imm) 95) 95, 95. 95 Na Imm) 5 65 65 6 a [mm 100 100 100 100 r2 [mm 180 180 180 180 RL, [mm 160 160 160 160 ‘Ss Bxi9 Bxi9 exo Bx19 Sd 4x19 4x19 4x19 4x19) coMMON AD Imm 170 132 132 233 DATA Gi Imm) 11s 115 115 5 SNB/SMB.CI a2 [mm] 14s 145 145 145 mi [mm 125 125 125 125 ma [mm 95 95 35 Eg nL Imm 280) 280 280 280 2 [ml 212, 212, 212, 212) b Imm) 65 65 65. 65 st [mm] Miz Maz Maz Maa ha [mm] 112 160 160 160 A [mm] 189 195 195 254 K [mm] Miz Maz Maz Maz 5 [mm 140 120 120 210 TSNB: [mm 276 315) 315) 345 18 [onl 330) 413 413) 561 SNB.cIDATA c Imm) 60. 136 136 108 P [mm 250) [300 [300 350 NETWT(APK)_[_ [kel 80, 95 96 163 GROSS WT. (APX) [kal 90) 05 106 173 L [nm] 520 596 596 689. sme .cl DATA c Imm 149 219) 219) 143 NET WT (AP) _[_ [kel 60. 68. 69. 130) GROSS WT. (APX) | _ kal 70 78 73. 140 NOTE: For requite of SNB/SMB SS gad, please contact to shakt PERFORMANCE CURVE ‘SNB/SMB 65-160 (2 POLE) wage O10 20 30 a) 50 60 70 80 9 10126 130 140 150 16 180.190 Of mYh] Recommended suction x delivery pipe size [kW / H.P] 75/10.0 100 x 80 mm [kW /HP]11.0/15.0 : 100x80mm (kW / HP] 15.0/20.0 : 100x80mm [kW/ HP] 185/250 : 100x80mm 46 PERFORMANCE TABLE menos SNB/SMB 65-160 (2 POLE) amp ype 65-160 ‘Motoripe [High ER Motor SMGi22_[ Swe 160 [ swe i160 [sume i60 Pe wary | rs0 | ais | 15/20 | 185/26 PR ba 16 16 DNs: tent 35 95 Nal tenn 5 65 a em 100 100 100 i trom) 200) 200) 200 im tenn 360 160 160 Ss axis eas | axao 3a axig_| 4g | 4x9 common AD im 132 233) 233 DATA GL mm] 128, 128 128, SN /SMB 2 rm) 766 766) 766) a ma tm) 125. 125 325; ma enm) 5 9 5 nL rn) 280) 280 280 m2 tm) 212 242 2 ten) 65 5 st mm) [wa waa Miz ng tommy 160 160 160 A tenml 95) 254) 254 K trmmj [a2 waa maiz 3 trom 220) 210 210 TSNB mam ait 341 341 1B ten) 413 561 61 sNeci c tenn FE 108 108; DATA 2 (eam) 300) 250 350 NETWT APR) tea 4 165 178) GROSS WT.APK) [| __thal oa 5, 150 L mm] 592, 685 = = sme ci c tr) 215 139) ~ 7 DATA NET WT. (APR) tal 74 135; ~ 7 GROSS WI.APK) [tn 3 15 zi zi NOTE: For requite of SNB/SMB SS gad, please contact to shakt a7 PERFORMANCE CURVE menos SNB/SMB 65-200 (2 POLE) . 4 toe) 4 th ‘Se a0 : Fea soe 10 92082012 Grade 2 NPSH Recommended suction x delivery pipe size [kW /H.P] 18.5/25.0 : 100x100 mm [kW / HP] 22.0/30.0 : 400% 100mm [kW / HP] 30.0/40.0 : 100% 100mm PERFORMANCE TABLE menos SNB/SMB 65-200 (2 POLE) Pump ype 65-200 Motor type High Eff, Motor ‘SMmG 160 | SMMG180_| sMMG200 Po {kW/HP] 18.5/25 22/30 30/40 PN [bar] 16 16 16 DNs. [mm] 90 90 20 DNd mm) 65 65. 65 a [mm] 100 100) 100 ne [mm 225 225 225 hd [mm 180 180 180 Ss 8x19 Bx19 8x19 Sd 4x19 4x19 4x19 AD. [mm] 233 236 276 Gt [mm] 150) 150 150 2 im] 187 187 187 mi Imm] 125 125 125 m2, imm| 95 95 95. SNB CI DATA nt. Imm] 320 220 320 n2 Imm 250 250 250) b im} 65 6 65 si [mm] M12 Miz M12 ha [mm] 160 180 200 A im} 254, 279) 318 K mm Mi2 Maa Mi6 8 im} 254 242 305) LSNB [mm] 342 342, 342, LB Imm] 561 545, 650) c Imm] 108 121 133 P (mm 350 350 400 NET WT. (APX kg 220 246 305) GROSS WT. (APX.) | _[ke] 230 255 318 NOTE: For require of SNB/SMB SS gad, please contact to shakt 49 PERFORMANCE CURVE SNB 80-160 (2 POLE) ‘SNB SMB 80-160, 2Pole, 50 Hz 180 9906:2012 Grade 38 Recommended suction x delivery pipe size (kW / HP] 11.0/15.0 ew / H.P] 15.0/20.0 (kW / HP] 18.5/25.0 (lew HP] 22.0/30.0 125 x 100 mm 125 x 100 mm 125 x 100 mm 125 x 100 mm PERFORMANCE TABLE ‘SNB/SMB 80-160 (2 POLE) Pump type 80-160 Motor type High Eff Motor ‘SWIMG 460 | SMMG 160 | SMMG 460 [SMMG 180 Py wp) | aayas_ [15/20 | 185/25 [22/30 PN. [bar] 16 16, i6 16 DNS! mm! 400 00 00 100 Nd Imm ‘30. 0) ‘50. 50. a [mm 125 125 125) 125 na Imm 225 225 225 225 hi {mm 180 180 780) 180 Ss exia x19 ext x19) Sd x19 x19 8x19 8x19 AD. [nm 233, 233, 233) 236 Gi {mm 1a 144 74 Ta 2 {mm 187, 187, 187 187 m7 fmm 125 125 15 125 ‘SNB C1 DATA m2, [mm 95, Es 95. 95, nt [mm 320, 320, 320 320 2 [mm 250) 250) 250) 250) b [mm 5, 5, Es 65. si {mm Mid Miz Maz, Miz hg Imm 160 160 160 180 B [mm 210 210) 254) 2a A [mm 254) 254, 254 279 K {mm Miz Miz Mia Mia TSNB: [mm 368, 368, 368, 368 18 [mm 561 564 561 545 c [mm 108, 108 108 21 P [mm 350) 350) 350) EEG NET Wr PX) kg] 174 182 205, 282 (GROSS WT. (APX) ke) 195 203 226, 263) 51. PERFORMANCE CURVE SNB 32-160.1 (4 POLE) SNB/ SMB 32-160.1 4-Pole, 50 Hz ISO 9906:2012 Grade 38 NPsH [mJ +0 05 0.0 O12 8 # 6 6 7 B 8 1 2 18 Me 18 Olmn] Recommended suction x delivery pipe size [kW / H.P] 0.37/05 50x40 mm: 52 PERFORMANCE TABLE SNB 32-160.1 (4 POLE) Pump type Motor type SNB Cl DATA High Eff.Motor Po PN. DNs DNd a h2 hd Ss Sa Gt G2 mL n2 b st LB P AD NET WT. (AX) GROSS WT. (APX) [KW/HP) [bar] mm] mm [mm] [mm] mm] [mm] mm] mm [mm] [mm] mm] mm [mm] [mm] mm] mm] [mm] [ke] K 32-460.4 ‘SMG 71 0.37/05 16 50, 32 EG 160 132 Axio) axi9) 120) 123 100) 70 240) 190 50, M12 204 210) 160) 107 32, 38, 53 PERFORMANCE CURVE ‘SNB 32-160 (4 POLE) we toh ‘SNB/ SMB 32-160 4-Pole, 50 Hz ISO 9906:2012 Grade 38 NesH Im] oud 18 Ofna] a7 ali/s] Recommended suction x delivery pipe size [kW /H.P]0.55/0.75 : 50x50mm PERFORMANCE TABLE SNB 32-160 (4 POLE) Pump type 32-460 Motor type High Eff.Motor ‘SMG 80 Py KW/HP) 0.55/0.75 PN [bar] 16 DNs [mm] 50 DNd [mm 32 a [mm 80 he [mm] 160 ha [mm 132 Ss 4x19 Sd 4x19 Gi [mm] 115 G2 [mm 125 SNB Cl DATA mi {mm} 100 m2 [mm] 70 nd [mm] 240 n2 mm 190 b [mm 50 si [mm] M12, USNB [mm] 212 1B [mm 242 P [mm] 200 AD tml 125 NET WT. (APK) Tel 32 ‘GROSS WT. (APX) kg] 38 55 PERFORMANCE CURVE ‘SNB 32-200 (4 POLE) ‘SNB/ SMB 32-200 4-Pole, 50 Hz ISO 9906:2012 Grade 38 Recommended suction x delivery pipe size (kW / H.P] 0.75/1.0 50x50 mm: Tews HP] 14/15 50x50 mm. PERFORMANCE TABLE amen SNB 32-200 (4 POLE) Pump type 32.200 Motor type. High Eff.Motor SMG 80 SMG 90S Po [kW/HP] 0.75/1.0 1.1/1.5 PN [bar] 16 16 DNs (mm) 50 50 DNd [mm] 32 32 a (mm) 80 80 h2 [mm 180 180 nL {mm 160 160 Ss 4x19 4x19 Sd 4x19 4x19 Gt [mm] 134 134 G2 {mm] 145, 145, ‘SNB Cl DATA mt {mm] 100. 100 m2 {mm] 70 70 nL (mm 240) 240 n2 [mm] 190 190 b {mm] 50 50, st [mm Mad M12 LSNB {mm 229 242 LB [mm] 242 269 P {mm] 200 200 AD, (mm) 125 133 NET WT. (APX.) (ke) 40 45 GROSS WT. (APX.) {kg} 36 51 87 PERFORMANCE CURVE SNB 40-125 (4 POLE) ‘SNB/ SMB 40-125 ° 4-Pole, 50 Hz eo ISO 9906:2012 Grade 38 Recommended suction x delivery pipe size (kW /H.P] 0.25/0.30 : 65x65mm [kW/HP]0.37/0.50 : 65x65mm (kW / HP] 0.58/0.75 : 65x65mm PERFORMANCE TABLE “ SNB 40-125 (4 POLE) Pump type 40-125 Motor type | High Eff. Motor SMG 74 SMG 74 ‘SMG 80 Pp pewynP] | 0.25/03 | 0.37/05 | 055/075 PN [bar] 16 16 16 DNs [mm 65 65 65 DNa mm 40) 40 40 a [mm] 80 80 80 ha. [mm] 140 140 140 ha. [mm] 142 142 112 Ss x19 Ax19 x19 Sd 4x19 x19 x19 Gt [mm] 115 115 115 G2. [mm] 118 118 118 SNB Cl DATA mL [mm] 100 100 100 m2 [mm 70 70. 70 na [mm] 210 210 210 n2. [mm] 160 160 160 b [mm] 50 EA 50 st [mm] M12 M12, M12 TSN [mm] 201 201 242 LB [mm] 210 210 242) P [mm 160 160 200 AD, [mm 107) 107) 125 NET WT (APX) kg] 31 34 35 GROSS WT. (APX) 1g) a7 40 a1 59 PERFORMANCE CURVE ‘SNB 40-160 (4 POLE) ‘SNB/ SMB 40-160 4-Pole, 50 Hz 1S0 9906:2012 Grade 38 Recommended suction x delivery pipe size (kW / HP] 0.75/.0 65x50 mm. 60 PERFORMANCE TABLE SNB 40-160 (4 POLE) Pump type 40-160 Motor type High Eff. Motor ‘SMG 80 Pe [kW/HP) 0.75/10 PN [bar] 16 DNs [mm] 65 DNd [mm] 40 a [mm] 80 h2. [mm] 160 ht [mm 132 Ss 4x19 Sd 4x19 Gt [mm 116 G2 [mm 134 SNB Cl DATA mi. [mm 100 m2 [mm] 70 nd [mm] 240 n2. [mm] 190 b [mm] 50 st [mm M12. LSNB [mm 212 LB. [mm] 242 Pp [mm 200 AD [mm 125 NET WT. (APX.) [kel 36 GROSS WT. (APX.) ke] 42 ea PERFORMANCE CURVE SNB 40-200 (4 POLE) ur ‘SNB/ SMB 40-200 8 4-Pole, 50 Hz 604] sos ISO 9906:2012 Grade 3B Recommended suction x delivery pipe size (kw / HP] 1.4/1.5 65x65 mm. ew / HP) 15/20 65x65 mm @ PERFORMANCE TABLE “ SNB 40-200 (4 POLE) Pump type 40-200 Motor type High Eff.Motor ‘SMG 90S SMG 90L Pa [kW/HP] 14/15 1.5/2.0 PN [bar 16 16 DNs [mm 65 65 ONG [mmr 40 40 a [mm 100 100 2 [mm 180 180 nd [mm 160 160 Ss 4x19 4x19 Sd 4x19 4x19 Gi [mm] 143 143 G2 [mm 157 157 ‘SNB Cl DATA mi [mm| 100 400 m2 [mm 70 70 nd [mm 265 265 n2 {mm} 212 212 b [mm] 50 50 st [mm M12, m2 LSNB [mm 244 244 LB [mm 269 325 P [mm 200 200 AD [mm 133 133 NET WT. (APX [ke] 45 46 GROSS WT.(APX) | [ke] St 52 3 PERFORMANCE CURVE SNB 40-250 (4 POLE) 1H ted 2 SNBY SMB 40-250 aa 4-Pole, 50 Hz 10 9906:2012 Grade 38 Recommended suction x delivery pipe size [kW / HP] 2.2/3.0, 65x50 mm. lew / HP 3.0/4.0, 65x50 mm PERFORMANCE TABLE amen SNB 40-250 (4 POLE) Pump type 40-250 Motor type High Eff.Motor SMG 100 SMG 100 Py [kW/HP] 2.2/3.0 3.0/4.0 PN [bar] 16 16 DNs [mm] 65 65 DNd [mm] 40. 40 a {mm} 100 100 h2, [mm] 225, 225 nL im] 180) 180 Ss 4x19) 4x19) Sd 4x19 4x19 G1 [mm] 162 162 @ [mm] 182 182 ‘SNB Cl DATA mi {mm} 125, 125 m2. Imm] 90 90 nl (mm) 320 320 n2 {mm} 250 250 & [mm) 65 65 st [mm] M12 M12 LSNB [mm] 273 273 LB [mm] 314 324 P [mm] 250 250 AD {mm} 153 153 NET WT. (APX) [ke 62 63 GROSS WT. (APX.) tke} 70 71 co PERFORMANCE CURVE SNB 50-125 (4 POLE) tet ‘SNB/ SMB 50-125 8 4-Pole, 50 Hz wos ISO 9906:2012 Grade 38 Recommended suction x delivery pipe size [kW /H.P] 0.55/0.75 : 80x80mm lew / HP] 0.75/1.0 80x65 mm 66 PERFORMANCE TABLE SNB 50-125 (4 POLE) Pump type 50-125 Motor type High Eff:Motor ‘SMG 80 ‘SMG 80 Po [KW/HP] 0.55/0.75 0.75/1.0 PN {bar} 16 16 DNs [mm] 65 6 DNd Imm] 50 50 a [mm] 100 100 ha [mm] 160 160 AL [mm] 132 132 Ss 4x19 4x19 Sa ax19 ax19 G1 [mm] 117 117 G2 [mm] 133 133 SNB CI DATA ma [mm] 100 100 m2 Imm] 70 70 at [mm] 240) 240) n2 [mm] 190) 190 b Imm] 50 50 st [mm] M12 M12 LSNB Imm] 233 233 LB [mm] 242 242 P [mm] 200 200 AD [mm] 125 125 NET WT. (APX.) (kg) 35 36 GROSS WT. (APX) | _[kel a1 72 7 PERFORMANCE CURVE SNB 50-160 (4 POLE) beat th ‘SNB/ SMB 50-160 4-Pole, 50 Hz 1S 9906:2012 Grade 38 Recommended suction x delivery pipe size (kw / HP] 1.4/1.5 80x65 mm [kw /HP] 15/20 80x 65 mm (kW / HP] 2.2/3.0, 80x 80 mm PERFORMANCE TABLE amen SNB 50-160 (4 POLE) Pump ype 50-160, Motor type | High EffiMotor Swo0s | SMG90L_| SwG100 Pe Tw] | 14/45 1.5/2.0 2.2/3.0 PN [bar] 16 16 16 DNs [mm] 65 65 65 DNa mm} 50 50 50 a [mm] 100 100 100 n2 mm} 180) 180) 180 ht [mm] 160 160 160 Ss. x19 4x19 4x19 Sd x9 4x19 x9 Gi [mm] 150 150 150 a2 im) 125 125. 125 'SNB CI DATA mi {mm} 100 100) 100 m2 [mm 70 70 70 aL Imm] 265 265, 265 n2 Imm] 212 212 212 b Imm] 50 50 50 st (mm) maa Mia Maz LSNB [mm] 245 245 273 LB Imm] 269 325, 314 P (mm) 200 200 250 AD Imm] 133 133, 153 NETWT.(APK) tke) 44 42 60 GROSS WT. (APX.) [kg] 46 47 68 cy PERFORMANCE CURVE menus SNB 50-200 (4 POLE) ‘SNB/ SMB 50-200 4-Pole, 50 Hz 1S 9906:2012 Grade 38 Recommended suction x delivery pipe size [kW / HP] 2.2/3.0, 65x65 mm. lew / HP 3.0/4.0, 65x65 mm 70 PERFORMANCE TABLE amen SNB 50-200 (4 POLE) Pump type 50.200 Motor ype High Ef Motor ‘SMG 100 SMG-400 Pa W/L 2.2/3.0 3.0/4.0 PN ibari 16 16 DNs tem) oS 6s DNa (mm) 50, 50, a tent 100 100 ha. mm) 200 200 a trom 160 760 ss ado ado 3a ado 4x9 Gt trom 150 250 G2 [mm] 170 170 SNB.CI DATA mt Imm) 100 100 m2 (mam) 70 70 na trom) 270. 270 na tenml 212 212 > trom] 50 50 ot trom) Mia uaa sna (oom) 272 272 i tem a4 324 P tem) 250 250 AD trom) 158 158 NET WT (APR) tal 38 39 GROSS WT. (APX) thal 6 6 7 PERFORMANCE CURVE menus SNB 50-250 (4 POLE) ped col a e ‘SNB/ SMB 50-250 m viola 50 ie an] a 180 900812042 Grade 88 Recommended suction x delivery pipe size [kW / HP] 4.0/5.5 65x65 mm. 72 PERFORMANCE TABLE amen SNB 50-250 (4 POLE) Pump type 50-250 Motor type High Eff.Motor SMG 112 Py [kW/HP} 40/55 PN {bar} 16 DNs. [mm] 65 DNd [mm] 50 a {mm} 100 n2 mm) 234) ht [mm] 180 Ss 4x19 Sd 4x19) G1 {mm} 170 G2 [mm] 188 ‘SNB Cl DATA ma mm) 125 m2 (mm) 95 nt [mm] 320 n2 [mm] 250 b (mm) 65 si [mm] M12 LSNB [mm] 273 1B [mm] 373, P (mm) 250 AD. [mm] 168 NET WT. (APX) tke 78 GROSS WT. (APX.) kel 86 73 PERFORMANCE CURVE SNB 65-125 (4 POLE) SNB/ SMB 65-125 4-Pole, 50 Hz 1S 9906:2012 Grade 38 wn] Recommended suction x delivery pipe size (kW / H.P] 0.75/1.0 100 x 80 mm [ew /HP] A415 80x80 mm 74 PERFORMANCE TABLE amen SNB 65-125 (4 POLE) Pump type 65-125. Motor type High Eff Motor ‘SMG 80 ‘SMG 90S Py [kW/HP] 0.75/1.0 1.1/1.5 PN [bar] 16 16 DNs [mm] 95 95, DNd [mm] 65. 65 a [mm] 100 100 h2 Imm] 180 180 ha Imm] 160 160 Ss 8x19 8x19 Sd 4x19 4x19 G1 [mm] 115 115 G2 imm] 145 145) ‘SNB CI DATA mi [mm] 125 125 m2 [mm] 95 95 na [mm] 280 280 n2 [mm] 212 212 b [mm] 65. 65. st Imm] M12 M12 LSNB [mm] 236 248 LB [mm] 242 269 Pp [mm] 200 200 AD. [mm] 125 133 NET WT. (APX.) [kg] 41 46 ‘GROSS WT. (APX.) kg] a7 52 5 PERFORMANCE CURVE SNB 65-160 (4 POLE) ety tol} v0 SNB/ SMB 65-160 4-Pole, 50 Hz 1S 9906:2012 Grade 38 Recommended suction x delivery pipe size (kw / HP] 1.4/1.5 80x80 mm [kw /HP] 15/20 1100 x 80 mm (kW / HP] 2.2/3.0, 100 x80 mm 76 PERFORMANCE TABLE SNB 65-160 (4 POLE) Pump type 65-160 Motor type High Eft Motor ‘SMG 90S, ‘SMG 90L ‘SMG 100 Pe tew/ne) [2.4/2.5 15/20 2.2/3.0 PN. [bar] 16 16 16 DNS [mm] 95 95 Eg Na [mm 65 65 cS a [mm 100 100 100 ho. [mm] 200 200 200 ha [mm 160 160) 160) Ss x19 x19 x19 Sd 4x19 4x19 4x19 GL [mm] 128 128 128 G2 [mm 166 166 166 SNB Cl DATA mt [mm 125) 125) 125) m2 [mm] 95. 95 95 na [mm] 280 280 280 n2. [mm] 212 212 212 b [mm] 65 65 6 sl [mm Maz Maz Miz LSNB [mm 245) 245) 272, 1B [mm] 269 325 314) P [mm 200 200 250 AD, [mm] 133) 133) 153) NET WT. (APX.) [kel 44 45 54 GROSS WT. (AP) (el 50. 51. 62 77 PERFORMANCE CURVE SNB 65-200 (4 POLE) eat oth 220-| 20 ‘SNB/ SMB 65-200 * 4-Pole, 50 Hz 180. ISO 9906:2012 Grade 38 (r] 0 6 12 18 2 30 se 42 4B SH 60 88 72 78 BF 90 Ofni/n] 60 66 72 78 84 90 Olmi/n] Recommended suction x delivery pipe size (kW / HP] 3.0/4.0 100 x 80 mm [kW / HP] 4.0/5.5 1100 x 80 mm 78 © SHA PERFORMANCE TABLE SNB 65-200 (4 POLE) Pump type 65-200 Motor type] High Eff Motor SMG 505, ‘SMG 400 ‘SMG 100 swe 232 Pa (ew/HPy[ 1.5/2.0 2.2/3.0 3.0/4.0 40/58 PN. ba 76 16 16 76 DNs Imm 30) 90) ‘90, 90, DNa [mm 5 5. 65 65, a [mm 700 7007 00 00 h2 [mm 225 225, 225) 225 RL [mm 180 180 180 180 Ss Bi ext) Bxi9 Bi Sa 4x19) x19) axi9 4x19) Gr Tam 50 350 750 750 snscl a2. [mm 182 182 182 182 DATA mi [mm 125 125 125 125 m2, mm 90. 90) 90) 90. AL [mm 320) 320, 320) 320) 2 [mm 250 250 250) 250 b [mm 65, 65, 65 65. si mm Miz Miz Miz Miz TSNE, mm 245 272 272 272 ts [mm 355) Bia aia EET P. [nm 200 250) 250) 250 AD, im a0 iss. 153 168 NETWTIAPK) Ike) 55, 62 65 67 GROSS WTAAPK) | (Ke) 60, 7, 70 7 79 PERFORMANCE CURVE ‘PUMPING LIFE SNB 65-250 (4 POLE) wwesy toh 30 ‘SNB/ SMB 65-250 4-Pole, 50 Hz 1S 9906:2012 Grade 38 Recommended suction x delivery pipe size (kW / HP] 5.5/7.5 100 x 80 mm 30 SHAKTI PERFORMANCE TABLE Moore SNB 65-250 (4 POLE) Pump type 5250 Motor type | High Eff Motor ‘SMG 432 Po [kW/HP] 5.5/7.5 PN {bar] 16 DNs im] 80 DN [mm] 65. a (ram) 100 2 [mm] 250 hd [mm] 200 Ss 8x19 Sd 4x19 Gt imi 183 SNB Cl G2 {mm} 200 DATA mi [mm] 160 m2 [mm] 120 nd [mm] 360 n2 (ron) 280) b [mm] 80, st [mm] a6 LSNB [mm] 343 LB [mm] 428 P [mm] 300, AD [mm] 209 NET WT. (APX.) (kg) 124 [GROSS WT. (APX)] Ike} 132 cr PERFORMANCE CURVE ‘SNB 80-160 (4 POLE) ‘SNB/ SMB 80-160 4-Pole, 50 Hz 1S 9906:2012 Grade 38 Recommended suction x delivery pipe size [kW / HP] 1.5/2.0 125 x 125 mm [kw / HP] 2.2/3.0, 125 x 100 mm Dew / HP] 4.0/5.5, 425 x 100 mm 32 PERFORMANCE TABLE © SHA ry SNB 80-160 (4 POLE) Pump type 80-160 Motor type | High Eff. Motor ‘SMG 905 ‘SMG 100 SMG 112 Py (KW/HP}| 1.5/2.0 2.2/8.0 4.0/5.5 PN {bar] 16 16 16 Dns Imm] 100) 100) 100 DNa [mm] 80 80 80 a [mm 125) 125 125) na [mm 225 225 225 nL [mm 180 180 180 Ss 8x19 x19 exi9 Sd 8x19 8x19 8x19 Ga (mim) 141 441 aa G2 (mm 187 187 187 SNB Cl ma. [mm] 125) 125) 125) DATA m2, [mm 95 95 95 nd [mm] 320 320 320 n2 [mm] 250 250 250 b [mm] 5 65 5 st [mm Maa M12 Maz USNS [mm] 271 299 299 iB (mimi) 280 314 373 P mm 200) 250 250 AD [mm 133) 153 168) NET WT(APX) Kel 56 67 68 GROSS WTIAPX) Kel 63 72 76 33 PERFORMANCE CURVE SNB 80-200 (4 POLE) ‘SNB/ SMB 80-200 4-Pole, 50 Hz 1S 9906:2012 Grade 38 Recommended suction x delivery pipe size (kW / HP] 5.5/7.5 125 x 100 mm PERFORMANCE TABLE pene NB 80-200 (4 POLE) Pump type 80-200 Motor type High Eff. Motor ‘SMG 132 Pp [KW/HP] 5.5/7.5 PN [bar] 16 DNs [mm] 100 DNd [mm] 80 a Imm] 125 h2 [mm 260 ha [mm] 180 Ss 8x19 Sa x19 G1 [mm] 160 G2 [mm] 194 SNB Cl DATA mi [mm] 125 m2, [mm] 95 nt [mm] 345 n2, [mm] 280 b Imm] 65 st (mm) maa. LSNB [mm] 368 LB (mm) 428 P [mm] 300 ‘AD [mm] 209 NET WT, (APX.) ke] 109 GROSS WT. (APX.) (kg) 118 85 SHAKTI ACCESSORIES ‘SNB/SMB Cl Support Blocks ‘Stoel support blocks are used to compensate for dimensional differences between pump housing and motor frame sizes. The support blocks can be fitted under the motor or pump housing feet during instalation thus enabling horizontal alignment of the pump. The product numbers in the tables below refer to a set of two suppor blacks with the dimensions specified. Hexagon head bolts, washers and nuts are supplies together with support blocks, ‘SNB/SMB Cl, 60H, 2-pole Dimensions [Support|] Product initial Weteniovmi| blocks | number exayee 2: sveysm 32-160, sox17sx20] + | so00007s82 sess 4060 se/sie 0-25 Sxeyewe 32.200, qaseasesxi7s] + | 100000760 Says 40 SNB/SM6 0% s0xi00x28| ++ | 1000007608 se/sis so-25 SXSETEEPSIO) SNB/SMB 32-250 vB 32.260) [sne/sW5 40-200, NB 40.200 vB 40.250 sveysme 50360 | 11 SNE 50-160) 35] esxa04x20] + | 2000007600 sveysMeosa95 | a4 [sneys5 65-260 [an SVB 65-160) 15 vB 65-260 ies vB 80.260 au SNE 80-160) 35 SAB. iss [sneyswe 32200 [a sviyse 40.200 | 11 SauSnneniey [ar] £9%100x20 | ++ | so0onsss fxesnseo [a5 ex s0200 | 22 xm oS225-[ at sveysme6sa60_| a1 Sb 65.160, 15 sve 65-260 385] osx225x20] ++ | 100000760 s\B 50.250) 30 [exe 50-250 a7 + Support blocks to be fitted under motor fect. ‘Support blocks to be fitted under ump housing feat 86 SHA ACCESSORIES Counter flanges Counter flange kits consist of one steel flange, one gasket of asbestos-‘ree material, and the requisite number of screws. otra Flanges Desepion —Ratedpresre REN, Threaded —16bar,EN 10922 RPA N32 Forwelding 16 bar,EN10922 32mm Threaded «26 bar,EN 1092.2 RPA nao Forwelding 18 ba, EN10922 40mm N50 Threaded 16 bar, EN 1092.2 Rp2 Threaded 16 bar, EN 10922 RR 2% ones Forwelding 16 bar,EN10922 65mm Threaded 16 bar, EN 1092.2 Rp DN a0 Forwelding 18 bar,EN10922 80mm Threaded 16 bar, EN 1092.2 Roa DN 100 Forwelding 16 bar,EN 10922 100mm 87 Bl ow. BO] O= gg cco MSE Ne, 2800203 S56 Othe Counties 1 23:7282 120500 SHAKTI PUMPS (INDIA) LTD. Sector -3, Pithampur - 454774, Dist, - Dhar, (M.P.)- INDIA. Fax: +91-7292 410645, E-mall: info@shaktipumps.com, sales@shaktipumps.com, Visit us at : wwwshaktipumps.com

You might also like