DCX Web Page Interface
Instruction Manual
This product incorporates lwIP TCP IP Stack software under the following Copyright and License:
Redistribution and use in source and binary forms, with or without modification, are permitted provided that
the following conditions are met:
1. Redistributions of source code must retain the above copyright notice, this list of conditions and the fol-
lowing disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other materials provided with the distribution.
3. The name of the author may not be used to endorse or promote products derived from this software with-
out specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR IMPLIED
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO
EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPE-
CIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR
BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTH-
ERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF
THE POSSIBILITY OF SUCH DAMAGE.
April 2013
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Excel, Windows 7, Windows Vista, and Windows XP are registered trademarks of Microsoft Corporation
Other trademarks and service marks mentioned herein are held by their respective owners.
ii 100-412-187 Rev. 3
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Power Supply
Web Page Interface
Instruction Manual
Foreword
Congratulations on your choice of a Branson Ultrasonics Corporation system!
The Branson DCX Series systems are process equipment for the joining of plastic parts using ultrasonic
energy. They are the newest generation of products using this sophisticated technology for a variety of cus-
tomer applications. This Instruction Manual is part of the documentation set for these systems, and should
be kept with your equipment.
Thank you for choosing Branson!
Introduction
This manual is arranged into several structured chapters which will help you find the information you may
need to know to use the DCX Web Page Interface. Please refer to the Table of Contents and/or the Index of
this manual to find the information you may be looking for. In the event you require additional information,
please refer to your power supply manual. For additional assistance, contact our Product Support depart-
ment (see Section 1.3, "How to Contact Branson" on page 1-4 for information on how to contact them) or
your local Branson representative.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
iv 100-412-187 Rev. 3
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface
Instruction Manual
Table of Contents
100-412-187 Rev. 3 v
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Appendix A: Information on Ultrasonic Welding
A.1 Resonance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A-1
A.2 The Principle and the Components of Ultrasonic
Welding - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A-2
A.2.1 The Principle - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A-2
A.2.2 The Components - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A-2
A.3 Resonance Analysis - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A-5
A.3.1 Getting a Horn Scan Data - - - - - - - - - - - - - - - - - - - - - - - - - - - A-5
A.3.2 Scan Horn Error Analysis - - - - - - - - - - - - - - - - - - - - - - - - - - - - A-7
A.4 Graphics of a Weld - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A-9
A.4.1 Weld Graph Error Analysis - - - - - - - - - - - - - - - - - - - - - - - - - - -A-11
A.5 DCX Alarms Table- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -A-14
Index
vi 100-412-187 Rev. 3
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface
Instruction Manual
List of Figures
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
viii 100-412-187 Rev. 3
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface
Instruction Manual
List of Tables
100-412-187 Rev. 3 ix
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
x 100-412-187 Rev. 3
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 1: Safety and Support
Instruction Manual
This chapter contains an explanation of the different safety notice symbols and icons found in this manual
and provides additional safety information for ultrasonic welding. This chapter also describes how to con-
tact Branson for assistance.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 1: Safety and Support
Safety Requirements and Warnings
! W A R N IN G
WARNING indicates a hazardous situation or practice which, if not avoided, can result in seri-
ous injury or death.
! C A U T IO N
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or mod-
erate injury.
i N OT I CE
NOTICE is used to address practices not related to personal injury. It contains important infor-
mation. It might also alert the user to unsafe practices or conditions that can damage equip-
ment if not corrected.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 1: Safety and Support
Instruction Manual General Precautions
! C A U T IO N
Sound level and frequency of the noise emitted during the ultrasonic assembly process may
depend upon a. type of application, b. size, shape and composition of the material being
assembled, c. shape and material of the holding fixture, d. welder setup parameters and e.
tool design. Some parts vibrate at an audible frequency during the process. Some or all of
these factors may result in an uncomfortable noise being emitted during the process. In such
cases operators may need to be provided with personal protective equipment. See 29 CFR
(Code of Federal Regulations) 1910.95 Occupational Noise Exposure.
1.2.2 Emissions
When being processed, certain plastic materials can emit toxic fumes, gases or other emissions that can be
hazardous to the operator’s health. Where such materials are processed, proper ventilation of the worksta-
tion is required. Check your materials suppliers for recommended protection when processing their materi-
als.
! C A U T IO N
Processing of many materials, such as PVC, can be hazardous to an operator’s health and
could cause corrosion/damage to the equipment. Use proper ventilation and take protective
measures.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 1: Safety and Support
How to Contact Branson
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 1: Safety and Support
Instruction Manual How to Contact Branson
At this Phone
What you need help with or information about . . . Whom to Call
Number...
Your local Branson Rep or 203-796-0400
Information about new welding systems or components
Branson Customer Service Ext 384
Application and Setup questions on the 203-796-0400
Welding Applications Lab
welding system Ext 368
Application assistance on the Horns and 203-796-0400
ATG Lab
Tooling Ext 495
203-796-0400
Technical questions about the welding system Welding Product Support
Ext 355, 551
203-796-0400
Technical questions about Horns and Tooling ATG Lab
Ext 495
Ordering new parts Parts Store 877-330-0406
RGA’s, Request for Repair, Status of a Repair Welding Repair Department 877-330-0405
203-796-0400
System Automation/Hookup Information Product Support
Ext 355, 551
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 1: Safety and Support
How to Contact Branson
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 2: The Web Page Interface
Instruction Manual
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 2: The Web Page Interface
Introduction
2.1 Introduction
The DCX Power Supply Web Page Interface provides access, via Ethernet connection, to web pages con-
taining power supply information, diagnostics tools, and configuration options. Communication can be
established point-to-point or through a local area network. On the web page interface you can access:
• Power supply information:
— Power level
— Frequency
— Serial number
— Software Version
— Alarm Log
• Diagnostics tools
— Ultrasonic Test
— Horn Signature
— I/O Diagnostics
• Configuration options
— Weld Preset
— Frequency Seek
— Power On Seek/Scan
— IP Setup
— I/O Configuration
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 3: Connecting to the Web Page Interface
Instruction Manual
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 3: Connecting to the Web Page Interface
Locating the Ethernet Port
Ethernet Port
Ethernet Port
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 3: Connecting to the Web Page Interface
Instruction Manual System Requirements
i N OT I CE
The DCX Power Supply is not compatible with network scanning software. If your local net-
work uses these types of programs, the DCX Power Supply IP address must be placed in an
exclusion list.
i N OT I CE
A shielded Ethernet cable should be used to connect to the DCX Power Supply Web Page
Interface to prevent possible EMI (Electromagnetic Interference) issues.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 3: Connecting to the Web Page Interface
Point to Point Connection (Windows Vista and Windows 7)
7. Right click on Local Area Connection and select Properties to bring up the Networking tab.
8. Highlight Internet Protocol Version 4 (TCP/IPv4) from the list and click on Properties.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 3: Connecting to the Web Page Interface
Instruction Manual Point to Point Connection (Windows Vista and Windows 7)
IP Setup Weld Preset I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
LOGIN
User ID#
Log In
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 3: Connecting to the Web Page Interface
Point to Point Connection (Windows XP)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 3: Connecting to the Web Page Interface
Instruction Manual Point to Point Connection (Windows XP)
7. Highlight Internet Protocol (TCP/IP) from the list and click on Properties.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 3: Connecting to the Web Page Interface
Point to Point Connection (Windows XP)
10. Open the Internet Explorer web browser (version 7 and up).
11. In the address bar type the following address: http://192.168.10.100. Press Enter.
12. This will bring up the DCX Web Page Interface.
13. Enter a user ID number (any number up to 9 digits long).
IP Setup Weld Preset I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
LOGIN
User ID#
Log In
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
Webpage Interface Overview
IP SETUP
Static IP
B Subnet Mask
Gateway
255. 255. 255. 0
. . .
DHCP Client
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual Login
4.2 Login
When connection is established with the DCX Web Page Interface, the Login page will display. Enter a
unique user ID number. The user ID is numeric only and up to 9 digits long. This number allows for keeping
track of user access.
IP Setup Weld Preset I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
LOGIN
User ID#
Log In
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
IP Setup
4.3 IP Setup
Use this menu to setup the DCX Power Supply’s network settings. The DCX Power Supply’s default IP set-
ting is Static IP with the address shown in the figure below.
IP Setup Weld Preset I/O Diagn ostics Test & Horn System I/O Alarm Log
Weld Graphs Signatu re Information Configuration
IP SETUP
Static IP
Gateway . . .
DHCP Client
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual IP Setup
Select this option to have the DCX Power Supply automatically request an IP
DHCP Client
address from a DCHP Server. The IP address will be grayed out.
i N OT I CE
All changes on this menu take effect on the next power-up.
At any time you may determine the DCX Power Supply’s IP address by going through the associated reg-
isters using the front panel LCD (for DCX S units). A Cold Start can also be performed to take your power
supply back to it’s factory default IP address. For details on navigating the DCX registers or performing a
Cold Start, consult your power supply manual.
i N OT I CE
Beware that other settings will also be reset to their defaults when a Cold Start is executed.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
Weld Preset
IP Setup Weld Preset I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
Frequency Offset
Frequency (Hz) 0 Seek
Seek Time (ms) 500
External
LatchingAlarms
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual Weld Preset
Select the External check box to control the frequency offset using an analog
input from the user I/O connector (J3). (See Section 4.9, "I/O Configuration.")
The time it takes for the amplitude to ramp up to 100% when the External Start
Start Ramp (ms) signal is applied. If amplitude setting is lower than 100%, ramp time will be
adjusted accordingly. Valid range is 1 to 999.
Select this check box to have the DCX Power Supply update the horn operat-
End of Weld Store
ing frequency at the end of each weld.
Select this check box to have the DCX Power Supply wait for a reset after an
alarm condition. The Reset signal can be applied via the user I/O digital input
Latching Alarms or using front panel Reset key (DCX S units only).
Clear this option to have the DCX Power Supply wait for only a toggle of the
Start signal.
SEEK*
The time it will take the power supply to ramp-up when performing a seek.
Seek Ramp (ms)
Valid range is 1 to 999.
Seek Time (ms) The duration of a seek. Valid range is 1 to 999.
Select this check box to have the power supply perform a seek every 60 sec-
Timed Seek
onds. Seeks will be timed from the moment sonics was last activated.
POWER ON
Off Select this option to disable power-on actions.
Seek Select this option to have the power supply perform a seek on power-up.
Scan Select this option to have the power supply perform a horn scan* on power-up.
* For a definition of Seek and Horn Scan, consult the DCX Instruction Manual.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
I/O Diagnostics
i N OT I CE
The assigned power supply functions will not be performed by the power supply, only the sig-
nals levels can be controlled and monitored while in this menu.
i N OT I CE
Pin designation will reflect the current user I/O assignment.
IP Setup Weld Preset I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual I/O Diagnostics
** If the input signals are not within their valid range, or if left unconnected, the power supply will use 50% amplitude and
zero frequency offset, respectively.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
Test & Weld Graphs
IP Setup Weld Preset I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
PS TEST
Overload - Cleared
40500 96 96 96 96 54
PWM AMPLITUDE (%)
40300 84 84 84 84 36
FREQUENCY (Hz)
AMPLITUDE (%)
40100 72 72 72 72 18
CURRENT (%)
PAHSE (Deg)
POWER (%)
39900 60 60 60 60 0
39700 48 48 48 48 -18
39500 36 36 36 36 -36
39300 24 24 24 24 -54
39100 12 12 12 12 -72
38900 0 0 0 0 -90
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
TIME (ms)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual Test & Weld Graphs
i N OT I CE
Always clean your internet browsing history before getting a Weld Graph data.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
Horn Signature
IP Setup Weld Preset I/O Test & Horn System I/O Alarm Log
Diagnostics Weld Graphs Signature Information Configuration
HORN SIGNATURE
Status
Failed
Aborted
50 50 90
45 45 72
40 40 54
35 35 36
AMPLITUDE (%)
30 30 18
CURRENT (%)
PAHSE (Deg)
25 25 0
20 20 -18
15 15 -36
10 10 -54
5 5 -72
0 0 -90
38901 39101 39301 39501 39701 39901 40101 40301 40501 40701 40901
FREQUENCY (Hz)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual Horn Signature
Series Resonant Points Displays the series resonant frequencies of the ultrasonic horn.
Update Graph Click to draw the graph of last Horn Scan.
Export Graph Data Click to export the scan graph data with scan settings to CSV file.
Redraw Graph Click to redraw the same graph.
Draw from.......to....... Select the "from" and "to" time values to zoom into the desired graph region.
Select a parameter and enter a particular X time value to obtain the corre-
Graph Selection
sponding Y value at that particular time.
Update Value Click to update the Y value.
Click to return the sample rate, start time, end time and graph selection to
Set Default
default settings.
User Comment Box Enter comments to be added at the top of exported data in CSV file.
i N OT I CE
Always clean your internet browsing history before getting a Scan Graph data.
Refer to Section A.3, "Resonance Analysis," and Section A.3.2, "Scan Horn Error Analysis" for Horn Scan
Analysis.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
System Information
IP Setup Weld Preset I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual I/O Configuration
! W A R N IN G
When using 0 V to activate ultrasonics (External Start signal), it is recommended to assign
one input as Cable Detect to prevent sonics from activating if 24 V is lost by accident.
IP Setup Weld Preset I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
J3 - 1 J3 - 7
J3 - 2 J3 - 8
J3 - 3 J3 - 9
J3 - 4 J3 - 10
J3 - 17 J3 - 24
J3 - 18 J3 - 25
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
I/O Configuration
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual I/O Configuration
ANALOG OUTPUTS
Select/clear check boxes to enable/disable analog outputs.
The following output signals are available:
• Amplitude Out: Provides a 0 to 10 V output signal proportional to amplitude
(0 to 100%).
• Power Out: Provides a 0 to 10 V output signal proportional to ultrasonic
power output (0 to 100%).
• Frequency Out: Provides a 0 to 10 V output signal that indicates relative fre-
J3 - 24 and J3 - 25 quency in memory. The signal range is between 0 and 10 V (5 V is zero offset).
Actual frequency depends on the power supply operating frequency:
* If the signal is not within this range or if left unconnected the frequency offset will default to zero.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
Alarm Log
i N OT I CE
Only the last 100 alarms are stored in memory.
IP Setup Weld Preset I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Chapter 4: Using the Web Page Interface
Instruction Manual Alarm Log
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Chapter 4: Using the Web Page Interface
Alarm Log
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Appendix A: Information on Ultrasonic Welding
Instruction Manual Resonance
This section provides details on ultrasonic welding. Among other, these details are important in order to be
able to understand the graphics. In section Section A.3.2, "Scan Horn Error Analysis" you will also find
information on error analysis.
A.1 Resonance
Every solid body has its natural resonance. This is determined by the material it is made of and its total mass.
If, for example, a spanner falls on the ground, the typical metallic sound is generated. If we would measure
the tone pitch, we would have determined the natural resonance of the spanner. Another classic example is
the tuning fork. It is designed in a manner that it exactly vibrates at 440 Hz (philharmonic pitch A).
These are examples for resonance in the audible range (approx. 40 Hz to 16 kHz). Starting from a frequency
of 20 kHz this is referred to as ultrasonics. Also, any combination of converter, booster, and has its natural
resonance.
The aim is to utilise this resonance in order to achieve a maximum effect at lowest possible energy consump-
tion. This is the case if - to ease the explanation - the vibrating frequency feed in corresponds to the resonant
frequency of the acoustic stack. In this respect, it is important that an acoustic stack has two resonance
points: a serial and a parallel one. The parallel resonance point is the decisive one.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Appendix A: Information on Ultrasonic Welding
The Principle and the Components of Ultrasonic Welding
I 20kHz
S
K1
K2
40µm/20kHz
Item Description
1 US Power Supply
2 Converter
3 Booster
4 Horn
5 Acoustic stack
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Appendix A: Information on Ultrasonic Welding
Instruction Manual The Principle and the Components of Ultrasonic Welding
The power supply (1) transforms the energy supplied at 50/60 Hz from the mains to an ultrasonic frequency
of 20 kHz.
The high-frequency electrical oscillations of the power supply are transformed by the converter (2) via a
piezoelectric oscillator into mechanical vibrations of the same frequency, i. e. into mechanical vibrations at
20 kHz.
The mechanical vibrations must be transferred to the plastic part to be welded via an acoustic tool combi-
nation of booster (3) and horn (4). The booster amplifies the amplitude of the mechanical vibration (ampli-
fication factor K1).
The Booster
Not for all applications, a booster is required. The amplitude is amplified according to the energy conserva-
tion law. To amplify the amplitude of the vibration the cross-sectional area of the booster is varied. As the
vibratory energy must remain constant over the whole length of the booster (energy conservation law) the
amplitude is amplified proportional to the area ratio. This process can be illustrated by an undamped
spring-mass system. When the spring-mass system is excited it will emerge that the short thick spring has a
shorter elongation compared to the thin long spring although both spring oscillate at the same frequency.
For the ratio the following formula applies:
Where:
• Ae = Input amplitude
Ae Ve Me
F= • Aa= Output amplitude
Aa Va Ma
= = • Ve= Input oscillating velocity
• Va= Output oscillating velocity
• Me= Input Mass
• Ma= Output Mass
Nodal Point
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Appendix A: Information on Ultrasonic Welding
The Principle and the Components of Ultrasonic Welding
The Horn
The horn (also: welding tool) transmits the mechanical vibrations transformed by the converter and ampli-
fied by the booster to the plastic part.
Not only the booster but also the horn can amplify the amplitude (amplification factor K2). For calculation
of the amplitude ratios almost the same approach applies as for boosters.
Item Description
1 Rectangular horn
2 Catanoidal horn
3 Exponential horn
4 Step horn
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Appendix A: Information on Ultrasonic Welding
Instruction Manual Resonance Analysis
IP Setu p Weld Prese t I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signatu re Information Configuration
HORN SIGNATURE
50 50 90
45 45 72
40 40 54
35 35 36
AMPLITUDE (%)
30 30 18
CURRENT (%)
PAHSE (Deg)
25 25 0
15 15 -36
10 10 -54
5 5 -72
0 0 -90
38901 39101 39301 39501 39701 39901 40101 40301 40501 40701 40901
FREQUENCY (Hz)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Appendix A: Information on Ultrasonic Welding
Resonance Analysis
A scan is an automatic frequency seek. The values determined are stored and graphically displayed. The
values inform about the resonance properties of the system. When you compare the curve with other curves
you can draw conclusions with respect to the functioning and the acoustic properties of the acoustic stack.
In the course of the scan, ultrasonics are applied to the acoustic stack (converter/booster/horn) without load.
The stack freely vibrates in the air, starting with a start frequency that is continually increased up to the
adjusted end frequency.
HORN SIGNATURE
Status
Aborted
S P
50 50 90
45 45 72
40 40 54
35 35 36
AMPLITUDE (%)
30 30 18
CURRENT (%)
PAHSE (Deg)
25 25 0
20 20 -18
15 15 -36
10 10 -54
5 5 -72
0 0 -90
38901 39101 39301 39501 39701 39901 40101 40301 40501 40701 40901
FREQUENCY (Hz)
At the point of resonance, the current falls, the amplitude is at the maximum value, and the phase changes
its sign.
i N OT I CE
If multiple parallel frequencies are found, they will all be listed under Parallel Resonant Points.
The frequency at which the acoustic stack is running will be shown in blue.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Appendix A: Information on Ultrasonic Welding
Instruction Manual Resonance Analysis
Compare your system's curves with these examples to identify some of the possible problems you may
encounter.
HORN SIGNATURE
Status
Failed
Aborted
50 50 90
45 45 72
40 40 54
35 35 36
AMPLITUDE (%)
30 30 18
CURRENT (%)
PAHSE (Deg)
25 25 0
20 20 -18
15 15 -36
10 10 -54
5 5 -72
0 0 -90
38901 39101 39301 39501 39701 39901 40101 40301 40501 40701 40901
FREQUENCY (Hz)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Appendix A: Information on Ultrasonic Welding
Resonance Analysis
HORN SIGNATURE
Status
Failed
Aborted
50 50 90
45 45 72
40 40 54
35 35 36
AMPLITUDE (%)
30 30 18
CURRENT (%)
PAHSE (Deg)
25 25 0
20 20 -18
15 15 -36
10 10 -54
5 5 -72
0 0 -90
38901 39101 39301 39501 39701 39901 40101 40301 40501 40701 40901
FREQUENCY (Hz)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Appendix A: Information on Ultrasonic Welding
Instruction Manual Graphics of a Weld
IP Setu p Weld Prese t I/O Diagnostics Test & Horn System I/O Alarm Log
Weld Graphs Signature Information Configuration
PS TEST
Frequency 40034
Memory 40048
Amplitude 100
Power 2
40500 96 96 96 96 54
PWM AMPLITUDE (%)
40300 84 84 84 84 36
FREQUENCY (Hz)
AMPLITUDE (%)
40100 72 72 72 72 18
CURRENT (%)
PAHSE (Deg)
POWER (%)
39900 60 60 60 60 0
39500 36 36 36 36 -36
39300 24 24 24 24 -54
39100 12 12 12 12 -72
38900 0 0 0 0 -90
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
TIME (ms)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Appendix A: Information on Ultrasonic Welding
Graphics of a Weld
PS TEST
Overload - Cleared
40500 96 96 96 96 54
PWM AMPLITUDE (%)
40300 84 84 84 84 36
FREQUENCY (Hz)
AMPLITUDE (%)
40100 72 72 72 72 18
CURRENT (%)
PAHSE (Deg)
POWER (%)
39900 60 60 60 60 0
39700 48 48 48 48 -18
39500 36 36 36 36 -36
39300 24 24 24 24 -54
39100 12 12 12 12 -72
38900 0 0 0 0 -90
0 310 620 930 1240 1550 1860 2170 2480 2790 3100
TIME (ms)
At the beginning of the process, the frequency is increased until resonance is reached.
At the point of parallel resonance the weld starts. The following happens:
• the amplitude is controlled to the maximum value, and it remains virtually constant
• the phase changes the polarity
• the current increases to the maximum value and then decreases down to a relatively low con-
stant value
• the power output increases and then quickly decreases down to a constant value
• the PWM (Pulse Width Modulation) increases and remains constant.
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Appendix A: Information on Ultrasonic Welding
Instruction Manual Graphics of a Weld
Compare your system's curves with these examples to identify some of the possible problems you may
encounter.
PS TEST
Overload - Cleared
40500 96 96 96 54
40300 84 84 84 36
FREQUENCY (Hz)
AMPLITUDE (%)
40100 72 72 72 18
CURRENT (%)
PAHSE (Deg)
POWER (%)
39900 60 60 60 0
39700 48 48 48 -18
39500 36 36 36 -36
39300 24 24 24 -54
39100 12 12 12 -72
38900 0 0 0 -90
0 8 16 24 32 40 48 56 64 72 80
TIME (ms)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Appendix A: Information on Ultrasonic Welding
Graphics of a Weld
PS TEST
Overload - Cleared
40500 96 96 96 54
40300 84 84 84 36
FREQUENCY (Hz)
AMPLITUDE (%)
40100 72 72 72 18
CURRENT (%)
PAHSE (Deg)
POWER (%)
39900 60 60 60 0
39700 48 48 48 -18
39500 36 36 36 -36
39300 24 24 24 -54
39100 12 12 12 -72
38900 0 0 0 -90
0 3 6 9 12 15 18 21 24 27 30
TIME (ms)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface Appendix A: Information on Ultrasonic Welding
Instruction Manual Graphics of a Weld
PS TEST
Overload - Cleared
40500 96 96 96 54
40300 84 84 84 36
FREQUENCY (Hz)
AMPLITUDE (%)
40100 72 72 72 18
CURRENT (%)
PAHSE (Deg)
POWER (%)
39900 60 60 60 0
39700 48 48 48 -18
39500 36 36 36 -36
39300 24 24 24 -54
39100 12 12 12 -72
38900 0 0 0 -90
0 27 54 81 106 135 162 189 216 243 270
TIME (ms)
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
Appendix A: Information on Ultrasonic Welding
DCX Alarms Table
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
DCX Web Page Interface
Instruction Manual
Index
A F
alarm frequency
DCX alarm table, A-14 end of weld store, 4-7
log, 4-18 output range, 4-17
time stamp, 4-19 frequency offset
alarms external, 4-7
configuring, 4-7 internal, 4-7
amplitude range
external, 4-6 external, 4-17
internal, 4-6 internal, 4-7
start ramp, 4-7
H
B horn
Branson scan
how to contact, 1-4 power-on, 4-7
test, 4-11, 4-13
how to contact Branson, 1-4
D
DHCP
client, 4-5 I
server, 4-5 inputs
analog
amplitude, 4-17
frequency offset, 4-17
E
analog, configuration, 4-17
Ethernet port location, 3-2
analog, diagnostics, 4-9
Excel, downloading the alarm log, 4-19
digital
cable detect, 4-16
display lock, 4-16
external horn scan, 4-16
external reset, 4-16
external seek, 4-16
external start, 4-16
external test, 4-16
100-412-187 Rev. 3 i
DOC EXPIRES 5/28/2013 4:59:51 PM. Article or Material must comply with the
requirements stipulated by RoHS in its current version
memory clear, 4-16
digital, configuration, 4-16 S
digital, diagnostics, 4-9 safety
IP setup, 4-4 cable detect, 4-15, 4-16
general precautions, 1-2
PVC materials, 1-3
M symbols, meaning, 1-2
manual set, 2-2 scan
power-on, 4-7
seek
power-on, 4-7
O ramp, 4-7
outputs time, 4-7
analog timed, 4-7
amplitude, 4-17 system requirements, 3-3
frequency, 4-17
power, 4-17
analog, configuration, 4-17
analog, diagnostics, 4-9 T
digital test
amplitude decay, 4-16 horn, 4-11, 4-13
general alarm, 4-16
overload alarm, 4-16
ready, 4-16 W
seek/scan out, 4-16 warranty, 1-4
sonics active, 4-16 web page interface, 2-2, 4-2
digital, configuration, 4-16 command buttons, 4-2
digital, diagnostics, 4-9 Ethernet port location, 3-2
IP setup, 4-4
login, 4-3
P menu tabs, 4-2
power supply point-to-point connection
default settings (cold start), 4-5 Windows Vista and Windows 7, 3-3
intended use, 1-3 Windows XP, 3-3
IP address, 4-4, 4-5 setting the weld preset, 4-6
manual set, 2-2 system requirements, 3-3
models, 2-2 version number, 4-14
system information, 4-14 weld preset, setting, 4-6
PVC materials, safety, 1-3
ii 100-412-187 Rev. 3