Professional Documents
Culture Documents
PIF - QB - 138 - 20 R00 (Option-01)
PIF - QB - 138 - 20 R00 (Option-01)
General Information
Quotation No. QB_138_20 Entry Date: 08.11.20 Delivery Req On: 10.11.20
Client Name BRB Cable Industries Ltd. Location Kushtia.
Revision R00 Building No. 1 (Option-01)
Building Description: As per attached drawing
Building Type Width (m) Width Module (m)
MS 19.16 c/c of Steel Col. As per drawing
Length (m) Bay Spacing (m) Clear Height (m) Eave Height (m) Roof Type Slope
115.188 c/c of Steel 2@ 5.744 + 17@ 6.10 As per design Flat None
As per design
Column
Type of End Frames Interior Colm Base Exterior Colm Base End Colm Spacing (m) LEW & REW
As per design As per design As per design as per drawing
Open Wall Condition Type of Bracing Type of Eave (NSW, FSW: Eave Gutter, Down spouts)
As per drawing As per design N/A
Roof Sheet Wall Sheet Capping, Trims etc. Insulation
N/A N/A N/A N/A
Mezzanine
Width (m) Length (m) Floor Height (m) Mezz. LL (Kg/ft²) Roof LL (KN/m²) Type of Brick Wall
19.16 c/c 115.188 c/c 2.740 +2740 40 As per design As per drawing
Crane System
Crane Height (m) Crane Spane (m) Running Length (m) Crane Capacity (MT)
Accessories
Location Projection (m) Length (m) Soffit Panel Insulation
Roof Extension
Quantity (Nos.)
Location
Fascia Height (m)
Length (m)
Projection (m)
Quantity (Nos.)
Ridge Ventilator Length (m)
Throat (m)
Quantity (Nos.)
Roof Monitor Length (m)
Throat (m)
Quantity (Nos.) 4
Flight Type Double
Width (m) 1.200
✘ Steel Stair Handrails Yes
Top Landing No
Mid Landing Yes
Tread Type Checkered Plate
Width (m)
Door Height (m)
Type
Quantity (Nos.)
Louver Length (m)
Width (m)
Type Quantity (Nos.) Length (m) Width (m) Capacity
Power Ventilator
Sky Light
Ventilation Wall Light
Exhaust Fan
Natural Ventilator
Special Note: Please consider the MS chequered plate on every floor.
(Thickness: As per design)
Design Load
Wind Speed (km/h) Live Load on frame Live Load on Purlin Collateral Load (KN/m²) Mezz. DL Mezz. LL (Kg/ft²)
(KN/m²) (KN/m²) (KN/m²)
215 (Expo-A) 0.58 0.96 N/A As per design 40.0
Seismic Zone Maximum Rainfall Intensity (mm/hr)
Zone- 1 150
Design Code
BNBC 2006
Attachment
Proposal Drawing
Feedback Required
Particulars Requirment (Y/N) Out put Name of Design Engineer
Total Building Weight Yes
Rafter Depth No
Main Beam Depth Yes
Section Details No
Design Consideration Yes
Base Condition Yes
Foundation Drawing No
Design Calculation No
Column Reactions No
Staad File No
BUILDING DETAIL
BuildingType Building Usage:
Width (m) Total Building Area
Width Module (m) Intermediate Column: Y/N
Length (m) Height of RCCBeam
Bay Spacing (m) Height of Brick wall:
Clear Height (m) Existing Building Ht (For RT):
Eave Height (m) Type of Floor Slab (Flash/BP):
Type of Roof Ratio of Roof Slope
Type of End Frames Rof Extention Length:
End Column Spacing LEW & REW:
Exterior column Base Pinned
Condition
Bracing Type
Type of Eave NSW & FSW: Eave Gutter & Downspouts, RCC Gutter
Block Wall
ADDITIONAL INFORMATION
Insulation Roof only / Wall only / Both and Type & Thickness:
Sheeting Roof only / Wall only / Gable only /All & Color:
Door Type: Height: Size: Location: Qty:
Window Type: Height: Size: Location: Qty:
Canopy Type: Height: Size: Location: Qty:
Ventilation Type: Size: Location: Qty:
Sky Light Type: Size: Location: Qty:
Framed Opening Louver:
Mezzanine Width (m): Length(m): Steel Stair:
Clear Height(m): Eave Height: Type of B/W: Flush type By Pass
Crane Systems Crane Capacity (MT): Crane Height(m): Crane Type:
Crane Span(m): Crane Running Length(m):
Fascia
REMARKS